• Title/Summary/Keyword: Repeated measurements

Search Result 439, Processing Time 0.026 seconds

A Methodology for Compaction Control of Crushed-Rock-Soil-Fills (암버럭-토사 성토 노반의 다짐 관리 방안)

  • Park, Chul-Soo;Hong, Young-Pyo;Joh, Sung-Ho;Mok, Young-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.607-616
    • /
    • 2006
  • More strict construction control of railway roadbeds is demanded in high speed railway system because of heavier repeated dynamic loading than conventional railways. The aim of this study is to propose a compaction control methodology of crushed-rock-soil-fills including as large particles as $200\sim300mm$ in diameter, which are easily encountered in high speed railway roadbed. Field tensity evaluation and in turn compaction control of such crushed-rock-soil-fills are almost impossible by conventional methods such as in-situ density measurements or plate loading tests. The proposed method consists of shear wave measurements of compaction specimens in laboratory and in-situ measurements of fills. In other words, compaction control can be carried out by comparing laboratory and field shear wave velocities using as a compaction control parameter. The proposed method was implemented at a soil site in the beginning and will be expanded to crushed-rock-soil-fills in future. One interesting result is that similar relationship of shear wave velocity and water content was obtained as that of density and water content with the maximum value at the optimum moisture content.

  • PDF

A Study on the Body Measurements of Early Adolescent Boys (청소년 전기 남학생의 인체 계측치에 관한 연구)

  • Kim, Kyung-A;Suh, Mi-A
    • The Research Journal of the Costume Culture
    • /
    • v.13 no.1
    • /
    • pp.60-74
    • /
    • 2005
  • The purpose of this study was to systematize accurate data about the body measurements of early adolescent boys, as there was a broad individual variance between their bodies, and it's additionally attempted to identify the unique physical characteristics of different age groups. The subjects in this study were boys who were at the ages of 10 to 14 in the capital area. Their bodies were measured by anthropometric and photographic method, and data on 549 boys were analyzed. The total of 100 items(47 anthropometric items, 10 indexed items and 43 photographic items) were selected to be measured. For data analysis were performed descriptive statistics, ANOVA and Duncan test using SPSS Ver. 10. The results of the study are as follows. According to the result of comparing the body measurements of early adolescent boys, a period of active growth and a period of slow growth were repeated alternately as they aged and the age of active growth tended to get younger.

  • PDF

Visibility Measurement in an Atmospheric Environment Simulation Chamber

  • Tai, Hongda;Zhuang, Zibo;Jiang, Lihui;Sun, Dongsong
    • Current Optics and Photonics
    • /
    • v.1 no.3
    • /
    • pp.186-195
    • /
    • 2017
  • Obtaining accurate visibility measurements is a common atmospheric optical problem, and of vital significance to civil aviation. To effectively evaluate and improve the accuracy of visibility measurements, an outdoor atmospheric simulation chamber with dimensions of $1.8{\times}1.6{\times}55.7m^3$ was constructed. The simulation chamber could provide a relatively homogeneous haze environment, in which the visibility varied from 10 km to 0.2 km over 5 hours. A baseline-changing visibility measurement system was constructed in the chamber. A mobile platform (receiver) was moved from 5 m to 45 m, stopping every 5 m, to measure and record the transmittance. The total least-squares method was used to fit the extinction coefficient. During the experiment conducted in the chamber, the unit weight variance was as low as $1.33{\times}10^{-4}$ under high-visibility conditions, and the coefficient of determination ($R^2$) was as high as 0.99 under low-visibility conditions, indicating high stability and accuracy of the system used to measure the extinction coefficients and strong consistency between repeated measurements. A Grimm portable aerosol spectrometer (PAS) was used to record the aerosol distribution, and then Mie theory was used to calculate the extinction coefficients. The theoretical results were found to be consistent with the measurements and exhibited a positive correlation, although they were higher than the measured values.

Linear accuracy of cone-beam computed tomography and a 3-dimensional facial scanning system: An anthropomorphic phantom study

  • Oh, Song Hee;Kang, Ju Hee;Seo, Yu-Kyeong;Lee, Sae Rom;Choi, Hwa-Young;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.48 no.2
    • /
    • pp.111-119
    • /
    • 2018
  • Purpose: This study was conducted to evaluate the accuracy of linear measurements of 3-dimensional (3D) images generated by cone-beam computed tomography (CBCT) and facial scanning systems, and to assess the effect of scanning parameters, such as CBCT exposure settings, on image quality. Materials and Methods: CBCT and facial scanning images of an anthropomorphic phantom showing 13 soft-tissue anatomical landmarks were used in the study. The distances between the anatomical landmarks on the phantom were measured to obtain a reference for evaluating the accuracy of the 3D facial soft-tissue images. The distances between the 3D image landmarks were measured using a 3D distance measurement tool. The effect of scanning parameters on CBCT image quality was evaluated by visually comparing images acquired under different exposure conditions, but at a constant threshold. Results: Comparison of the repeated direct phantom and image-based measurements revealed good reproducibility. There were no significant differences between the direct phantom and image-based measurements of the CBCT surface volume-rendered images. Five of the 15 measurements of the 3D facial scans were found to be significantly different from their corresponding direct phantom measurements(P<.05). The quality of the CBCT surface volume-rendered images acquired at a constant threshold varied across different exposure conditions. Conclusion: These results proved that existing 3D imaging techniques were satisfactorily accurate for clinical applications, and that optimizing the variables that affected image quality, such as the exposure parameters, was critical for image acquisition.

Computerized Measurement on Angular Parameters for Hallux Valgus: Comparison of 100% and 150% Magnified Digital Radiography (무지 외반증 각변형에 대한 디지털영상의 전산화 계측: 100%와 150% 확대영상에서의 계측비교)

  • Sung, Il-Hoon;Lee, Doo-Yeon;Sung, Chang-Ho;Seo, Woo-Young
    • Journal of Korean Foot and Ankle Society
    • /
    • v.16 no.1
    • /
    • pp.53-57
    • /
    • 2012
  • Purpose: To study computerized measurements of angular parameters on 100% and 150% resized digital radiography of hallux valgus deformity Materials and Methods: 30 digital radiography of standing foot anteroposterior view of hallux valgus patients were included. Two observers(A, B) independently measured hallux valgus angle (HVA), 1-2 intermetatarsal angle (IMA), and distal metatarsal articular angle (DMAA) in two times on both 100%-size and 150% magnified images respectively, using computerized measurement software tools. The results were interpreted with the statistical software program, Statistical Analysis System, version 9.2. Results: In repeated measurements of each observer, measurements on 150% magnified image showed no differences of all three parameters and with 100%-size image, there were differences of HVA (observer A) and 1-2 IMA (observer B) (p>0.05). When testing interobserver reliability, both observers showed differences in measurement of HVA and DMAA (p<0.05), but no differences in measurement of 1-2 IMA in both images. Within the 95% confidence interval, limits of error of measurements between two observers on HVA, IMA and DMAA were $2.7^{\circ}$ $1.4^{\circ}$ and $5.0^{\circ}$ respectively in 100%-size images, and $2.6^{\circ}$, $1.6^{\circ}$ and $4.7^{\circ}$ respectively in 150% magnified images. Conclusion: In computerized measurements for angular parameters of hallux valgus with digital radiography, 150% magnified images showed intraobserver reliability. Both 100% and 150% magnified images failed to show interobserver reliability. Measurement of 1-2 IMA in both 100% and 150% images showed less interobserver error.

Preliminary study on the effects of pergolide on left ventricular function in the horses with pituitary pars intermedia dysfunction

  • Gehlen, Heidrun;Fisch, Judith;Merle, Roswitha;Trachsel, Dagmar S.
    • Journal of Veterinary Science
    • /
    • v.22 no.5
    • /
    • pp.64.1-64.12
    • /
    • 2021
  • Background: Pituitary pars intermedia dysfunction (PPID), a neurodegenerative disease leading to reduced dopamine production, is a common disease in aged horses. The treatment is based on administration of the dopamine agonist pergolide. This drug has been related to valvular fibrosis in humans, but the cardiovascular effect of this drug has not yet been investigated in horses. Objectives: To determine whether pergolide induces valvular disease in horses or affects the cardiac function. Methods: Standard, tissue Doppler (TDE) and two-dimensional speckle tracking (STE) echocardiography were performed in horses with diagnosed PPID based on adrenocorticotropic hormone dosage. Measurements taken in horses treated with pergolide were compared with those from untreated horses with nonparametric t-tests. Furthermore, measurements from follow-up examinations performed at least three months after the initial exam were compared with a Wilcoxon signed rank test for repeated measurements in each group. Results: Twenty-three horses were included. None of the 12 horses under treatment developed valvular regurgitation. Furthermore, no differences in the measurements of the left ventricular systolic or diastolic function could be seen between the group of horses with treatment and those without treatment. Measurements taken in the follow-up exam did not differ compared to those taken in the initial exam in both groups. Conclusions: No changes of the left ventricular function assessed by TDE and STE could be shown in a small population of horses with confirmed PPID. Treatment with pergolide did not affect the ventricular function nor induce valvular disease.

Effect of a Mediterranean-style diet on the exercise performance and lactate elimination on adolescent athletes

  • Gizem Helvaci;Asli Ucar;Mehmet Mesut Celebi;Haydar Cetinkaya;Ayse Zulal Gunduz
    • Nutrition Research and Practice
    • /
    • v.17 no.4
    • /
    • pp.762-779
    • /
    • 2023
  • BACKGROUND/OBJECTIVES: Mediterranean diet is an environmentally friendly and healthy diet model. The diet offers many vegetables, fruits, nuts, and olive oil to consumers. In addition, it provides moderate amounts of fish and chicken, smaller quantities of dairy products, red meat, and processed meat. The Mediterranean diet has a high anti-inflammatory and antioxidant content, and it causes many physiological changes that can provide a physical performance advantage. This study examined the effects of a 15-day menu, which was planned using foods with a low acid load within the Mediterranean diet rules, on the exercise performance, lactate elimination, anthropometric measurements, and body composition. SUBJECTS/METHODS: Fifteen professional male athletes between the ages of 13 and 18, who were engaged in ski running, were included in the experimental study. Dietary intervention was applied for 15 days. The athlete performances were evaluated by applying the vertical jump test, hand grip strength, 20 meters shuttle run test, and Borg fatigue scale. After the shuttle run test (every 3 min for 30 min), blood was drawn from the finger, and the lactate elimination time was calculated. Performance and lactate measurements, body analysis, and anthropometric measurements were taken before and after dietary intervention. RESULTS: The vertical jump height and hand grip strength increased after the intervention (P < 0.05). The test duration, total distance, the number of shuttles, and maximum oxygen consumption parameters of the shuttle run test increased (P < 0.05). After the intervention, the athletes' perceived fatigue scores decreased in several stages of the shuttle run test (P < 0.05). The lactate elimination time and athlete's body composition were similar in repeated measurements (P > 0.05). In the last measurements, the upper middle arm circumference decreased while the height of the athletes increased (P < 0.05). CONCLUSIONS: These results show that the Mediterranean diet is a safe and feasible dietary approach for aerobic performance and strength increase.

RELIABILITY and VALIDITY of DUAL PROBE-FIXING FRAME for REHABILITATIVE ULTRASOUND IMAGING for EXERCISES with VISUAL FEEDBACK

  • Na-eun Byeon;Jang-hoon Shin;Wan-hee Lee
    • Physical Therapy Rehabilitation Science
    • /
    • v.12 no.3
    • /
    • pp.259-267
    • /
    • 2023
  • Objective: Rehabilitative ultrasound imaging is a safe and noninvasive technique for evaluating muscle thickness. A dual probe-fixing frame (DPF) can provide visual feedback during exercises targeting specific muscles. The purpose of this research was to verify the reliability and validity of the DPF for dual-probe ultrasound (DPU)-based visual feedback exercises, allowing users to use both hands freely. Design: This cross-sectional study used repeated measures to compare muscle thickness measurements obtained using the handheld device and DPF with DPU. Methods: Twenty healthy adults participated in the study. Measurements were taken over two sessions, with a two-day interval between the sessions. The thicknesses of the rectus abdominis (RA) and transverse abdominis (TrA) muscles were measured using DPU. The DPF with DPU developed by the research team, was used along with a laptop-based muscle viewer. Bland-Altman analysis and intraclass correlation coefficients (ICCs) calculations were used in statistical analyses to evaluate agreement and reliability, respectively. Results: The results of the Bland-Altman analysis showed small average differences between the handheld and DPF methods for both RA and TrA muscle thicknesses. Inter-rater reliability analysis showed high ICC values for DPF measurements of both RA (0.908-0.912) and TrA (0.892-741) muscle thicknesses. Intra-rater reliability analysis also showed good ICC values for measurements taken by a single examiner over two days. Conclusion: The findings of this study demonstrate that the DPF provides reliable and valid measurements of muscle thickness during visual feedback exercises using the DPU.

Quantification of Pancreas Surface Lobularity on CT: A Feasibility Study in the Normal Pancreas

  • Riccardo Sartoris;Alberto Calandra;Kyung Jin Lee;Tobias Gauss;Valerie Vilgrain;Maxime Ronot
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1300-1309
    • /
    • 2021
  • Objective: To assess the feasibility and reproducibility of pancreatic surface lobularity (PSL) quantification derived from abdominal computed tomography (CT) in a population of patients free from pancreatic disease. Materials and Methods: This retrospective study included 265 patients free from pancreatic disease who underwent contrast-enhanced abdominal CT between 2017 and 2019. A maximum of 11 individual PSL measurements were performed by two abdominal radiologists (head [5 measurements], body, and tail [3 measurements each]) using dedicated software. The influence of age, body mass index (BMI), and sex on PSL was assessed using the Pearson correlation and repeated measurements. Inter-reader agreement was assessed using the intraclass correlation coefficient (ICC) and Bland Altman (BA) plots. Results: CT images of 15 (6%) patients could not be analyzed. A total of 2750 measurements were performed in the remaining 250 patients (143 male [57%], mean age 45 years [range, 18-91]), and 2237 (81%) values were obtained in the head 951/1250 (76%), body 609/750 (81%), and tail 677/750 (90%). The mean ± standard deviation PSL was 6.53 ± 1.37. The mean PSL was significantly higher in male than in female (6.89 ± 1.30 vs. 6.06 ± 1.31, respectively, p < 0.001). PSL gradually increased with age (r = 0.32, p < 0.001) and BMI (r = 0.32, p < 0.001). Inter-reader agreement was excellent (ICC 0.82 [95% confidence interval 0.72-0.85], with a BA bias of 0.30 and 95% limits of agreement of -1.29 and 1.89). Conclusion: CT-based PSL quantification is feasible with a high success rate and inter-reader agreement in subjects free from pancreatic disease. Significant variations were observed according to sex, age, and BMI. This study provides a reference for future studies.

AN EVALUATION OF ROTATIONAL STABILITY IN ENDODONTIC ELECTRONIC MOTORS (근관치료용 전기모터의 회전 안정성 평가)

  • Park, Se-Hee;Seo, Hyun-Woo;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.4
    • /
    • pp.246-256
    • /
    • 2010
  • The purpose of this study was to evaluate a rotational stability of endodontic electronic motors by comparing the changes of rotational speed, depending on the number of usages and with/without static load. Twelve new endodontic electronic motors were used in this study. Non contact type digital tachometer was used for measuring the rotational speed of handpiece. True RMS Multimeter was used for measuring the voltages and the electric currents. All measurements were recorded every 10 seconds during 10 minutes and repeated 9 times. Five repetition was done per each electronic motor. To statistical analysis, student t-test, repeated measures and Scheffe's post-hoc tests were performed. In the same motor group, there was no significant difference in all measurements. In all groups, there was no significant difference in the amount of rotational speed changes depending on the number of usages and with/without static load. In the limitation of this study, the results showed that all kinds of endodontic electronic motors in this study had an established rotational stability. Therefore they could be safely used in root canal treatment with a reliable maintenance of rotational speed, regardless of the number of usages and with/without load.