• Title/Summary/Keyword: Repeated measurement data

Search Result 221, Processing Time 0.028 seconds

The Effects of Leg Muscles and Tendon Thickness on 7Hz Vibration Exercise Application in the Normal Adult (7Hz 진동자극 운동이 정상 성인의 다리 근육과 힘줄의 두께에 미치는 영향)

  • Park, Jae-Cheol;Yoo, Jin-Ho;Hwang, Tae-Yeon
    • PNF and Movement
    • /
    • v.18 no.3
    • /
    • pp.425-433
    • /
    • 2020
  • Purpose: The purpose of this study was to investigate the effect of 7Hz vibration on the thickness of the rectus femoris, medial femur, rectus femoris tendon, and Achilles tendon. Methods: The statistical methods before and after working around the average value of each of the legs included repeated measures ANOVA. The subjects were 26 males residing in the N area, and we measured the change in muscle thickness and tendon thickness before, four weeks, and eight weeks after the experiment in two groups of 13 subjects each. The analysis method was a two-way repeated measurement variance analysis (ANOVA) with a significance level of 0.05 Results: The rectus femoris, medial broad muscle, rectus femur, and Achilles tendon showed significant increases in the interaction between the periods as well as between the periods and groups (p < 0.05). Conclusion: As a result of this study, the 7Hz vibration had a positive effect on the thickness of the rectus femoris and the vastus medialis muscle as well as the thickness of the rectus femoris tendon and Achilles tendon. It is expected to be used as basic data for vibrational exercises in the future studies and is expected to be used as an exercise to strengthen the leg muscles and tendons.

A Portable Skin Elasticity Measuring Device Based on Indentation Method Using Piezoelectric Effect (압전효과를 이용한 압인방식의 휴대용 피부탄력 측정장치)

  • Park, Jun-Young;Kim, Myoung Nam
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.9
    • /
    • pp.1307-1315
    • /
    • 2022
  • In this paper, we proposed and developed a new portable skin elasticity measuring device based on the indentation method using piezoelectric effect. The proposed device is designed to minimize the uncertainty caused by the layer structure of the skin when measuring the elasticity of the skin. And, we developed a piezoelectric-based thin-film pressure sensor that can measure quantitatively and quickly during repeated measurement as a device sensor. To confirm the effectiveness of the proposed measuring device, it was compared with the experimental results of the conventional measuring devices under the same experimental conditions, and statistical correlation analysis was performed between the experimental data of the proposed measuring device and the experimental data of the conventional measuring devices. As a result of the correlation analysis, it was confirmed that the proposed measuring device had a high correlation with the conventional measuring devices. Therefore, it was confirmed that the proposed skin elasticity measuring device was effective.

Influence of Superficial Heat and Deep Heat for Lumbo-sacral Segment on H-Reflex (흉요추부의 표재열 및 심부열 적용이 H 반사의 변화에 미치는 영향)

  • Yoon, Se-Won;Lim, Young-Eun;Lee, Jeong-Woo
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.5 no.2
    • /
    • pp.1-9
    • /
    • 2007
  • Purpose: The purpose of this study was to investigate influence of superficial heat and deep heat for lumbo-sacral segment on H-reflex. Methods: Subjects of this research were 12 normal men and women (6 men and 6 women) and they were assigned to superficial heat group (6) and deep heat group (6). Heat treatment was applied between Th12-L2 by placing them at prone posture. superficial heat was applied for 20 min at 30 cm height with infrared lamp. Deep heat was applied for 20 mm at 5 cm height with 100 watt of microwave diathermy. H-reflex used diagnostic electromyography, active electrode was placed at muscle belly of medial gastrocnemius muscle at prone posture and electrical stimulation was given to posterior tibial nerve. Measurement was made before and after experiment and 10 min. and 20 min. after experiment. All data were analyzed with window 12.0 program, comparison of differences among measured items of groups according to repeated measurement was made with repeated measures ANOVA and significance level a was 0.05. Results: M latency at latency analysis showed little changes at two groups. H latency was reduced a little immediately after experiment and recovered to original state, there was significant difference. In analysis of amplitude, Mmax amplitude showed rise a little immediately after.

  • PDF

Inter-and Intra-rater Reliabilities of Myotonometric Measurement of the Erector Spinae Muscles in the Young and Old Age Groups (청년과 노인 연령군에 따른 척주세움근에 대한 마이오톤의 측정자 간, 측정자 내 신뢰도)

  • Han, Hyo-Gyeong;Choe, Ye-Ju;Jeong, Seong-Ho;Lee, Na-Kyung
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.9 no.1
    • /
    • pp.193-202
    • /
    • 2021
  • Purpose : The purpose of this study is to examine inter-and intra-rater reliabilities of myotonometric measurements of tone, elasticity and stiffness for the erector spinae muscles of the young and the elderly populations. Methods : A total of 102 (69 young adults from K university and 33 older adults from the D community center in Daejeon) were enrolled in this study. The two different raters measured each side of the erector spinae muscles at prone position. After each rater performed first measurement for a subject, 30 minutes of rest was given. The same rater then repeated the second myometric measurement on the subject. The collected data on the tone, elasticity, and stiffness of the erector spinae were analyzed using intraclass correlation coefficient (ICC) to determine inter- and intra- rater reliabilities. Results : The inter-and intra-rater reliabilities of the myotonometric measurement of the erector spinae for the total subjects were excellent (ICC > 0.9, p < 0.001). Within each of the elderly group and the young group, inter- and intra-rater reliabilities were also excellent (ICC > 0.8~0.9 / p < 0.001, ICC > 0.75~0.9 / p < 0.001, each). Conclusion : The measurement of muscle tone, elasticity, and stiffness for the erector spinae muscles using the myotonometer had excellent reliability. It was confirmed that a highly reliable myometric measurement on the erector spinae can be obtained regardless of whether it is from young or elderly people. This suggests that the myotonometer can be a useful tool to measure muscular properties of the erector spinae of the young and old as an evaluative instrument.

Accuracy of spring-style and friction-style mechanical implant torque wrench (스프링형과 마찰형 기계식 임플란트 토크 렌치의 정확도에 관한 연구)

  • Cha, Dong-Hee;Oh, Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.1
    • /
    • pp.8-13
    • /
    • 2016
  • Purpose: The aim of this study was to compare the accuracy of two different styles of mechanical implant torque wrenches before and after sterilization and repeated use. Materials and methods: Thirty new spring-style and friction-style mechanical implant torque wrenches from five different manufacturers were selected as subjects of study and assessed in terms of accuracy. Three manufacturers produced, spring-style (Dio, Neobiotech, Osstem) torque wrenches, and other three manufactures produced friction-style (Dentium, Osstem, Shinhung) torque wrenches. The procedure of target torque measurement was performed 10 times for each device and a digital torque gauge (MGT-12, Mark-10 Corp, USA) was used to record the measurements. All torque wrenches were used repeatedly for 20 times and then sterilized. This whole procedure was repeated 100 times and all torque wrenches were retested. The collected data was analyzed using a SPSS Statistics Analysis program to evaluate the accuracy of the torque wrenches and Mann-Whitney-U test was used for a comparative analysis. Results: After sterilization and repeated use procedure, results did not show any significant difference between error values in the spring-style torque wrench group. However, the results demonstrated an increase in error values within the friction-style torque wrench group (P<.05). Conclusion: There was no difference between the accuracy of new spring-style torque wrenches before and after 100 cycles of sterilization and repeated use (P>.05). There was significant difference between the accuracy of new friction-style torque wrenches before and after 100 cycles of sterilization and repeated use (P<.05). Within the limitation of this study, spring-style torque wrenches were more accurate than friction-style torque wrenches in delivering target torque values.

Robust ridge regression for nonlinear mixed effects models with applications to quantitative high throughput screening assay data (비선형 혼합효과모형에서의 로버스트 능형회귀 방법과 정량적 고속 대량 스크리닝 자료에의 응용)

  • Yoo, Jiseon;Lim, Changwon
    • The Korean Journal of Applied Statistics
    • /
    • v.31 no.1
    • /
    • pp.123-137
    • /
    • 2018
  • A nonlinear mixed effects model is mainly used to analyze repeated measurement data in various fields. A nonlinear mixed effects model consists of two stages: the first-stage individual-level model considers intra-individual variation and the second-stage population model considers inter-individual variation. The individual-level model, which is the first stage of the nonlinear mixed effects model, estimates the parameters of the nonlinear regression model. It is the same as the general nonlinear regression model, and usually estimates parameters using the least squares estimation method. However, the least squares estimation method may have a problem that the estimated value of the parameters and standard errors become extremely large if the assumed nonlinear function is not explicitly revealed by the data. In this paper, a new estimation method is proposed to solve this problem by introducing the ridge regression method recently proposed in the nonlinear regression model into the first-stage individual-level model of the nonlinear mixed effects model. The performance of the proposed estimator is compared with the performance with the standard estimator through a simulation study. The proposed methodology is also illustrated using quantitative high throughput screening data obtained from the US National Toxicology Program.

A Repeated-dose 28-Day Oral Toxicity Test of Aconitum jaluense Extract in Sprague-Dawley Rats (초오 추출물의 Sprague-Dawley 랫드를 이용한 28일 반복 경구투여독성시험)

  • Lee, Jong Suk;Lee, Ji Sun;Park, Yeong-Chul;Choi, Sun Mi;Lee, Sanghun
    • YAKHAK HOEJI
    • /
    • v.58 no.1
    • /
    • pp.62-70
    • /
    • 2014
  • A 28-day repeated-dose oral toxicity test was performed to determine the no-observed-effect level (NOEL) and establish an optimum dose of the highly toxic Aconiti Ciliare Tuber (ACT) used as a folk remedy. Repeated oral doses of 1,250, 2,500, and 5,000 mg/kg/day of the hot water extract of ACT were administered to five male and five female Sprague-Dawley rats in each group for 4 weeks. The indicators for toxicity included results of examination of common symptoms and changes in weight and feed intake, eye test, urinalysis, hematological and serum biochemical analyses, and post-mortem weight measurement of organs, and visual inspections. All animals survived at the end of the experiment; in addition, we observed no specific test substance-mediated symptoms. We observed no test substance-mediated changes in body weight and feed intake. We observed statistically significant changes in male OB and pH levels (p<0.05). Further, the biochemical test showed statistically significant changes in the IP value of male rats and $CL^-$valueoffemalerats (p<0.05). However, all changes were within historical data. The post-mortem examinations showed no test substance-mediated changes. Moreover, statistically significant changes under the test conditions were confirmed to have been caused by factors other than the test substance. Thus, the maximum NOEL of ACT extract in rats was estimated to be 5,000 mg/kg/day.

Reliability Study of Measuring Range of Motion Glenohumeral Joint Internal Rotation With Pressure Biofeedback Stabilization

  • Hwang, Ui-jae;Ha, Sung-min;Jeon, In-chul;Jung, Sung-hoon;Choi, Kyu-hwan;Kim, Su-jung;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.22 no.4
    • /
    • pp.62-70
    • /
    • 2015
  • The aims of the current study were to assess reliability of range of motion (ROM) measurement of glenohumeral internal rotation (GIR) with a pressure biofeedback stabilization (PBS) method and to compare the reliability between manual stabilization (MS) and the PBS method. In measurement of pure glenohumeral joint motion, scapular stabilization is necessary. The MS method in GIR ROM measurement was used to restrict scapular motion by pressing the palm of the tester's hand over the subject's clavicle, coracoid process, and humeral head. The PBS method was devised to maintain consistent pressure for scapular stabilization during GIR ROM measurement by using a pressure biofeedback unit. GIR ROM was measured by 2 different stabilization methods in 32 subjects with GIR deficit using a smartphone clinometer application. Repeated measurements were performed in two test sessions by two testers to confirm inter- and intra-rater reliability. After tester A performed measurements in test session 1, tester B's measurements were conducted one hour later on the same day to assess the inter-rater reliability and then tester A performed again measurements in test session 2 for confirming the intra-rater reliability. Intra-class correlation coefficient (ICC) (2,1) was applied to assess the inter-rater reliability and ICC (3,1) was applied to determine the intra-rater reliability of the two methods. In the PBS method, the intra-rater reliability was excellent (ICC=.91) and the inter-rater reliability was good (ICC=.84). The inter-rater and intra-rater reliability of the PBS method was higher than in the MS method. The PBS method could regulate manual scapular stabilization pressure in inter- and intra-rater measuring GIR ROM. Results of the current study recommend that the PBS method can provide reliable measurement data on GIR ROM.

A Review of Studies on Leadership in Nursing Organization (간호조직에서의 리더십에 관한 논문 고찰)

  • Park, Young-Joo;Seomun, Gyeong-Ae;Lim, Ji-Young;Kim, In-A
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.12 no.2
    • /
    • pp.311-322
    • /
    • 2006
  • Purpose: The objective of this literature review study was to identify patterns and trends of studies on leadership among nurse managers in nursing organization and suggest the direction of future researches. Methods: Research Studies on the leadership were selected from thesis and related journals, which had been conducted from 1975 to 2006.5. Search Terminologies were used "leadership". The Total number of the collected studies were 69. Results: The number of studies on leadership has been increased rapidly since 1990's. In research design, Quantitative studies were 68 except for a Qualitative study. Correlation research were 45(65.2%) among quantitative studies. Conceptual frameworks, research questions and hypotheses were involved 31.9%, 98.6%, 31.9%. In subject, General nurse is 46.4%, Head nurse and General nurse was 23.2% and Head nurse is 2.9%. All the studies used questionnaire in data collection method. Measurement tools were used 50% for Bass' MLQ(MLQ-5X). For the statistical analysis, Correlation, ANOVA, t-test were used for 20.3%, 17.4%, 10.5% respectively. The number of leadership related variables were work-related, organization-related, personal recognition or attitude, empowerment, personality. The sub-variables were used for 31 Job satisfaction. Further studies were suggested the develop of leadership program, measurement for the effect of leadership, repeated studies on leadership, the development of measurement about leadership. Conclusion: These results will be used to provide the basic data for developing leadership theory on nursing organization.

  • PDF

The Differences of Stride Length and Cadence between Normal and Obese Children (정상아와 비만아의 활보장과 분속수의 차이)

  • Kim, Jong-Jeong;Lee, Soon-Hyang;Ji, Seong-Chul;Doo, Jung-Hee
    • Physical Therapy Korea
    • /
    • v.3 no.2
    • /
    • pp.36-41
    • /
    • 1996
  • The purpose of this study was to determine whether the biomechanical variables of the walking patterns of the obese children compared with those of normal children would revealing significant differences. Normal(N=25) and obese(N=19) subjects were screened based on a health record which was examined to eliminate any subjects who had any pathological condition related to their gait. Data for a minimum of 5 repeated walking trials were collected using a stop watch and a tape measure. Basic kinematic analyses yielded data based on the following variables : stride length divided by leg length, and cadence divided by leg length. This measurement data was classified by the Obesity Index calculated from by height, weight data. Results showed no significant difference among normal, obese and subjects(p>.05). Difficulties in formulating the experimental condition and poor equipment quality are thought to be reason for the inconclusive results. Future studies might include medical complications such as tibia vara, genu valgum, other diseases caused by obesity.

  • PDF