• 제목/요약/키워드: Repeatability

검색결과 888건 처리시간 0.034초

포터블 양도락의 반복성.재현성에 대한 임상 연구 (A Clinical Study on the Repeatability and Reproducibility of Portable Ryodoraku Device)

  • 이지인;고성철;송호섭
    • Journal of Acupuncture Research
    • /
    • 제30권3호
    • /
    • pp.135-140
    • /
    • 2013
  • Objectives : The purpose of this study is to investigate the repeatability and reproducibility of the Ryodoraku acupuncture device. For such device to be accepted as a good apparatus for clinical diagnosis, the score it provides should be stable no matter who measure it or when it is measured, assuming all other conditions equal. Materials and Methods : Three oriental medical doctors who were well trained and fully aware of the usage of the Ryodoraku acupuncture device examined ten randomly selected patients three times. Each doctor measured the Ryodoraku scores three times from each of the 10 selected patients. Three doctors were involved in this experiment to investigate the reproducibility and each of them measured the Ryodoraku scores three times from each patient to investigate the repeatability. Data was analyzed with Friedman test, Spearman correlation test, and intra-class correlation coefficient(ICC) in SPSS ver. 18. Results : 1. The Friedman test showed that there is no statistically significant difference between the 1st, 2nd and 3rd Ryodoraku scores measured by the same examiner. It indicates that the Ryodoraku acupuncture device provides the repeatability. 2. Spearman correlation test confirmed the results obtained by the Fiedman test by showing that there exists a strong positive correlation between the three Ryodoraku scores measured by the same examiner. 3. A very high ICC among the three examiner assured that the Ryodoraku acupuncture device achieves the reproducibility. Conclusions : The Ryodoraku acupuncture device achieves the repeatability and reproducibility. However, we still recommend that a doctor trained to a certain level use the Device to carry out the diagnosis. Also, to improve the device in terms of Reproducibility even more, it should be considered to provide a manual for the exact usage.

한국 성인을 대상으로 한 미국 및 유럽 폐활량 검사 재현성 기준의 유용성 (Applicability of American and European Spirometry Repeatability Criteria to Korean Adults)

  • 박병훈;박무석;정우영;변민광;박선철;신상윤;전한호;정경수;문지애;김세규;장준;김성규;안성복;오연목;이상도;김영삼
    • Tuberculosis and Respiratory Diseases
    • /
    • 제63권5호
    • /
    • pp.405-411
    • /
    • 2007
  • 연구배경: 본 연구를 통해 2005년도 ATS/ERS 폐활량검사 지침에서 제시한 재현성 기준을 한국 성인들에게 적용할 수 있는 지와, 한국 성인들의 폐활량 검사 시 재현성에 영향을 미치는 요인들을 알아보고자 하였다. 방 법: 국민건강영양조사, COPD 코호트, 지역사회 코호트로부터 얻은 성인 4,663명의 폐활량검사 결과를 이용하여 dFVC 및 $dFEV_1$를 계산하여 분포를 알아보고, 1994년도 ATS 지침 및 2005년도 ATS/ERS 지침을 만족하는 검사의 비율을 비교하였다. 다중회귀분석을 통해 개인적 특성 및 재현성 기준의 변화가 재현성에 영향을 미치는가를 알아보았다. 결 과: 폐활량검사를 시행한 사람들 중 95% 이상이 150ml 이내의 재현성 기준을 만족시켰다. 1994년도 ATS 지침에 따라 검사를 시행한 경우 재현성을 만족하지 않는 경우가 증가하였다. 다중회귀분석 결과 재현성에 영향을 주는 요인들은 신장, 연령, 체중, 폐쇄성폐질환 여부, 재현성 기준의 변화 등이었으나 재현성에 영향을 미치는 정도는 매우 작았다(0.5~3.0%). 결 론: 한국인에게도 2005년도 ATS/ERS에서 제시한 재현성 기준을 적용할 수 있을 것으로 생각하며, 이를 위해서는 변경된 재현성 기준에 대한 지속적인 홍보와 검사자 들에 대한 교육 및 정도 관리가 필요하다.

Characteristics of Repetitive Positioning Control of a Linear Pulse Servo Motor

  • Masayasu, Yamamoto;Kouki, Matsuse
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.91-96
    • /
    • 1998
  • This study aims to realize high precision repetitive positioning control of the linear servo motor. The authors have previously improved the repeatability positioning precision by employing a two-degree-of-freedom PID controller in the positioning control, rather than equal distance positioning, and investigates the repeatability positioning precision.

  • PDF

휴대용 폐기능 검사기의 재현성과 기대치에 관한 연구 (Repeatability and Appropriate Predicted Value of Portable Spirometry on Korean Adults)

  • 최준용;정희재;이건영;정승연;황준호;이형구;정승기
    • 대한한방내과학회지
    • /
    • 제26권3호
    • /
    • pp.587-595
    • /
    • 2005
  • Objectives : The object of this study was to evaluate repeatability of portable spirometry and to determine an appropriate equation for predicted value. Materials and Methods : The subjects were 76 men and 45 women recruited from among Kyunghee University oriental medical students. Portable spirometry was performed via the procedure recommended in ATS guidelines. Repeatability of spirometry was checked against ATS repeatability standards and NHLEP QC grade. Percentage of predicted value of non-smokers was calculated through a Caucasian population-based regression equation(by Morris et al.) and Korean population based regression equation(by Kim et al.). These were compared. Result : 91.7% of subjects matched repeatability standards of ATS and 95% of subjects got interpretable NHLEP QC grades of A, B, and C. Mean percentage of predicted value by Morris et al. were as follows: Mean of FVC% was 90.86, FEV1% was 96.66, FEV1/FVC% was 107.48. Mean percentage of predicted value by Kim et al. were as follows. Mean FVC% was 92.38, FEV1% was 89.77, FEV1/FVC% was 96.95. Conclusions : Results of this study show that more than 90% of subjects meet repeatability criteria. This supports a role for the portable spirometer as a primary oriental medical office tool. Further, results are a verify that they Korean population-based predicted value equation is a more appropriate standard than the Caucasian population-based one, but a still more accurate standard is needed for the Korean adult population.

  • PDF

광통신용 페룰 가공을 위한 초미세 고기능 동축가공 연삭시스템용 이송계의 특성 평가 (Performance Estimation of Feeding System for developing coaxial grinding system of light communicative ferrule)

  • 안건준;최병옥;이호준;황창기
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.10-14
    • /
    • 2005
  • This report deals with a feeding system of the Coaxal grinding machine, processing optical ferrule. This report also examines the applicability of using the feeding system for the Coaxial grinding machine, by mean of conducting performance estimation. The results are as follow; Repeatability of regulating wheel is $17{\mu}m$, R/W rotation accuracy is between $30\;\~\;40{\mu}m$. This means 'Rotation accuracy' is lower than the concentricity level. Backlash generation level at the feeding system of the grinding wheel is under $1{\mu}m$, thereby positioning accuracy is controlled within $2{\mu}m$ In terms of repeatability, you can find occasional error at the returning process from the starting point. This error is resulted from the measurement tolerance of the starting point sensor. We will get the repeatability level under control by $1{\mu}m$, through improving the soft-ware used and up-grading the sensor at the starting point.

  • PDF

체질진단에 활용되는 안면 특징 변수들의 반복성에 대한 예비 연구 (A Preliminary Study on the Repeatability of Facial Feature Variables Used in the Sasang Constitutional Diagnosis)

  • 노민영;김종열;도준형
    • 사상체질의학회지
    • /
    • 제29권1호
    • /
    • pp.29-39
    • /
    • 2017
  • Objectives Facial features can be utilized as an indicator of Korean medical diagnosis. They are often measured by using the diagnostic device for an objective diagnosis. Accordingly, it is necessary to verify the reliability of the features which are obtained from the device for the accurate diagnosis. In this study, we attempt to evaluate the repeatability of facial feature variables using the Sasang Constitutional Analysis Tool(SCAT) for the Sasang Constitutional face diagnosis. Methods Facial pictures of two subjects were taken 24 times respectively for two days according to a standard guideline. In order to evaluate the repeatability, the coefficient of variation was calculated for the facial features extracted from frontal and profile images. Results The coefficient of variation was less than 10% in most of the facial features except the upper lip, trichion, and chins related features. Conclusions It was confirmed that the coefficient of variation was small in most of the features which enables the objective and reliable analysis of face. However, some features showed the low reliability because the location of facial landmarks related to them is ambiguous. In order to solve the problem, a clear basis for the location discussion is required.

계측기 능력분석과 실험계획법 (Gauge Capability Analysis and Designed Experiments)

  • 백재욱;조진남
    • 품질경영학회지
    • /
    • 제24권3호
    • /
    • pp.145-159
    • /
    • 1996
  • In today's organization, measurement plays a crucial role in helping improve process or quality. In this paper, we review the measurement error study, classical gauge repeatability and reproducibility study, and designed experiment suited for the determination of the measurement capability. Measurement error study is very simple to use but is rather crude. Hence, it should be used as a preliminary study to determine whether further study is necessary. Classical gauge repeatability and reproducibility (GR&R) study is the most common technique for evaluation of gauge capability. It calculates a percentage that relates the repeatability, reproducibility, and overall R&R to the specification range for the parameter measured. Hence, the individual repeatability and reproducibility statistics will indicate the area on which to concentrate. However, GR&R study only gives a point estimate of each component, which leaves a room for improvement. It is always good to integrate the use of control charts to ascertain the statistical stability of the measurement process. The tools of statistical experimental design are available for a comprehensive design and analysis of the measurement process. Hence, in this paper, we present gauge capability analysis as an experimental design problem and compare it with the classical GR&R study.

  • PDF

바이오 응용을 위한 공압 디스펜싱 시스템의 반복 정밀도 연구 (Repeatability Study of a Pneumatic Dispensing System for Bio-Applications)

  • 이상민;최인호;김준원
    • 센서학회지
    • /
    • 제21권1호
    • /
    • pp.53-58
    • /
    • 2012
  • Biological and chemical assays(e.g., clinical tests for medical diagnosis) are needed to handle small liquid volume with high accuracy and high reliability. Many micro-dispensing systems using various actuation methods have been developed and applied. In this research, we confirm repeatability of the cartridge-type dispensing system with various measuring methods for guarantee of an acceptable reliability. We systematically examine the dispensed volume variation and dispense rate during 500,000 shots of sequential actuation. Using the same method, we confirm the repeatability of dispensed volume while varying operating conditions and design parameter(i.e., outlet size) of the dispensing system. Also, we examine the consistency of the dispensed volume of droplet while varying the operating pressures. Furthermore, we repeatedly measure differences between an actual dispensed volume and a target volume. According to our results, it is expected that the stable and reliable performance of our dispensing system can effectively be used in various applications containing bio-solutions.

최대 수의적 수축 동안 뒤넙다리근 근력 반복성의 남녀 차이 (Sex differences in repeatability of measurement for hamstring strength during maximal voluntary contractions)

  • 임우택
    • 대한물리치료과학회지
    • /
    • 제27권1호
    • /
    • pp.9-17
    • /
    • 2020
  • Background: This study aimed to examine the repeatability of hamstring strength during maximal voluntary contractions (MVCs) and to examine the sex difference. Design: Quasi-experiment design. Methods: The study recruited 23 healthy young individuals as participants. Hamstring flexibility was measured before and after MVCs by active knee extension test. Five trials of MVCs were performed, and hip extension forces were measured using a strain gauge during MVCs. Repeatability was confirmed by intraclass correlation coefficient (ICC) and coefficient of variation, and the difference between male and female participants was confirmed by independent samples t-test. Results: The forces measured during MVCs were significantly different between men and women over five trials. We observed the minimum and maximum force production at the first and fifth trial of MVCs in both men and women. Excellent to moderate reliability of the hamstring strength during MVCs was found in men (ICC range, 0.70-0.98) and women (ICC range, 0.66-0.90). There was no significant difference in hamstring flexibility between men and women. Conclusion: In clinical settings, we recommend excluding the first trial of MVCs in both men and women. Additionally, performing at least three trials of MVCs would be useful to improve the reliability of the baseline measures in women.