• 제목/요약/키워드: Repeatability

검색결과 888건 처리시간 0.039초

관성측정장치를 이용한 요추 가동범위 측정방법의 반복성 및 검사자 내 검사-재검사 신뢰도 연구 (Test-retest Reliability and Intratest Repeatability of Measuring Lumbar Range of Motion Using Inertial Measurement Unit)

  • 안지훈;김현호;윤우석;이순호;신유빈;김상민;박영재;박영배
    • Journal of Acupuncture Research
    • /
    • 제31권1호
    • /
    • pp.61-73
    • /
    • 2014
  • Objectives : The purpose of this study is to estimate the test-retest reliability and the intratest repeatability in measuring the lumbar range of motion of healthy volunteers with wireless microelectromechanical system inertial measurement unit(MEMS-IMU) system and to discuss the feasibility of this system in the clinical setting to evaluate the lumbar spine movement. Methods : 19 healthy male volunteers were participated, who got under 21 points at oswestry disability index(ODI) were adopted. Their lumbar motion were measured with IMU twice in consecutive an hour for the test-retest reliability study. Intratest repeatability was calculated in the two tests separately. The calculated intraclass correlation coefficients(ICC) were discussed and compared with the those of the previous studies. Results : Lumbar range of motion of flexion $41.45^{\circ}$, extension $16.34^{\circ}$, right lateral bending $16.41^{\circ}$ left lateral bending $13.63^{\circ}$ right rotation $-2.47^{\circ}$, left rotation $-0.61^{\circ}$. ICCs were 0.96~1.00(intratest repeatability) and 0.61~0.92(test-retest reliability). Conclusion : This study shows that MEMS-IMU system demonstrates a high test-retest reliability and intratest repeatability by calculated intraclass correlation coefficients. The results of this study represents that wireless inertial sensor measurement system has portable and economical efficiency. By MEMS-IMU system, we can measures lumbar range of motion and analyze lumbar motion effectively.

관성측정장치를 이용한 경추관절 가동범위 측정의 검사 내 반복성 및 검사-재검사 신뢰도 연구 (Test-retest Reliability and Intratest Repeatability of Measuring Cervical Range of Motion Using Inertial Measurement Unit)

  • 김현호;김경욱;박지민;김은석;이민준;강중원;이상훈;박영배
    • Journal of Acupuncture Research
    • /
    • 제30권4호
    • /
    • pp.25-33
    • /
    • 2013
  • Objectives : To assess the test-retest reliability and the intratest repeatability in measuring the cervical range of motion of healthy subjects with wireless microelectromechanical system inertial measurement unit(MEMS-IMU) system and to discuss the feasibility of this system in the clinical setting to evaluate the cervical spine musculoskeletal. Methods : 12 healthy people who were evaluated as no- or mild-disability with neck disability index were participated. Their cervical motion were measured with IMU twice in consecutive two days for the test-retest reliability study. Intratest repeatability was calculated in the two tests separately. The calculated intraclass correlation coefficients(ICC) were discussed and compared with the those of the previous studies. Results : Cervical range of motion data were acquired and statistically processed: left rotation($61.64^{\circ}$), right rotation($65.12^{\circ}$), extension($61.98^{\circ}$), flexion($52.81^{\circ}$), left bending($39.31^{\circ}$), right bending($41.08^{\circ}$). ICCs were 0.77~0.98(intratest repeatability) and 0.74~0.93 (test-retest reliability) in the primary motion. In the coupling motion, intratest repeatability ICCs were 0.93~ 0.99(transverse primary plane), 0.88~0.97(saggital primay plane), and 0.77~0.93(coronal primary plane). Test-retest reliability of coupling motion were 0.90~0.97(transverse primary plane), 0.00~0.72(saggital primary plane), and 0.04~0.76(coronal primary plane). Conclusions : Several types of range-of-motion devices are now on use in many fields including medicine, but the practicality of the devices in clinical use is questionable for the convenient and economical aspects. In this study, we presented the reliability of cervical range of motion test with the developed wireless MEMS-IMU system and discussed its potential utility in clinical use.

심박변이도(心搏變移度)의 측정시간(測定時間) 표준화(標準化) 연구(硏究) (A Study on Standardization of Measuring Time for Heart Rate Variability)

  • 김규태;박영재;박영배;오환섭
    • 대한한의진단학회지
    • /
    • 제10권2호
    • /
    • pp.88-103
    • /
    • 2006
  • Objectives : We performed this study to search the best time for HRV measuring and which index has the validity in a short term measuring. Methods : At first, three examiner measured electrocardiogram(ECG) of 5 people(4 male + 1 female) for 20 minutes in two times. and we devided ten regions (0-5, 5-10, 10-15, 15-20, 0-10, 0-15, 0-20, 5-15, 10-20, 5-20 minutes). After that we finded the HRV index for each regions. To evaluate the validity, we used Gage Repeatability and Reproducibility Study by MINITAB(ver. 13.20). If the '%Study Var' is under 30 and 'Number of Distinct Categories' is over 4, we could tell it has validity(repeatability and reproducibility). Results : 1) The region and HRV index has repeatability and reproducibility, was HF index in 10-15 minutes. The HF index in 15-20 minutes gained 27.41(%Study Var) and 5(Number of Distinct Categories). 2) The HF index in 10-15 minutes has the better reproducibility than repeatability. The value of measurement is under the control. There is consistency among the examiner. The distribution of measurement is not large. There is no interaction between examiner and each people. 3) The HF index in 10-15, 0-10, 0-15, 0-20, 10-20 minutes was not enough to gain the repeatability and reproducibility. But it had some meanings ; %Study Var, Number of Distinct Categories is 32.68, 4 for 10-15 minutes, 34.43, 4 for 0-10 minutes, 34.44, 4 for 0-15 minutes, 33.56, 4 for 0-20 minutes, 32.07, 4 for 10-20 minutes. Conclusions : This study shows the best index of measuring HRV is the HF index in 15-20 minutes. So, from now on we should measure the HRV for 20 minutes and extract the HF index in 15-20 minutes. It must be the standard for HRV measuring.

  • PDF

맥솔(脈率) 측정방법(測定方法)의 신뢰도(信賴度) 분석(分析) (The Analysis on the Reliability of Measuring Pulse-Respiration Ratio)

  • 김동훈;양동훈;허웅;박영재;박영배
    • 대한한의진단학회지
    • /
    • 제9권2호
    • /
    • pp.123-144
    • /
    • 2005
  • Objectives: Pulse-Respiration Ratio has been used for estimating subject's Han-Yeol [寒熱] status since it mentioned in suwen [素問]. In practicing Pulse-Respiration Ratio over 5 means the status of Yeol [熱], Pulse-Respiration Ratio below 3 means the status of Han [寒]. We performed this study to examine the Optimum Standard for Measuring Pulse-Respiration Ratio on the Basis of Repeatability and Reproducibility. Methods: After subject's 5 minutes rest we measured subject's ECG, respiration pattern, EEG, EMG simultaneously. In this research examiner's number is two, subject's number is four, and the number of repeat is two. We calculated Pulse-Respiration Ratio through dividing Respiration cycle average by Pulse cycle average according to each standard including time section, $EEG(relative-{\alpha}$ density, $relative-{\beta}$ density, ${\alpha}/{\beta}$ and EMG. We analyzed these data through Gage R&R study using MINITAB 13.20 program and considered the results of below 30 %R&R and over 4 Number of Distinct Categories to have a significance. Results: 1. In the applying of time standard, Pulse-Respiration Ratio from section 3, 4, 6, 8 had a significant meaning in the aspect of Repeatability and Reproducibility. 2. In the applying of $EEG({\alpha}$ I , ${\beta}$ I , ${\alpha}/{\beta})$, EMG(E I) standard, there was no significant results. 3. In the applying of time standard(section 5, 6, 7), $EEG({\alpha}$ I , ${\beta}$ I , ${\alpha}/{\beta})$ and EMG(E I) standard simultaneously, Pulse-Respiration Ratio from ${\alpha}/{\beta}$ in section 6, ${\beta}$ I in section 8 had a significant meaning in the aspect of Repeatability and Reproducibility. Conclusions: We can suggest the Optimum Standard for Measuring Pulse-Respiration Ratio on the basis of Repeatability and Reproducibility as followings; 1. Pulse-Respiration Ratio Measuring time should be at least 15 minutes. 2. Applying of time(section 6, 8) and $EEG({\beta}$ I, ${\alpha}/{\beta})$ standard simultaneously is recommended considering reliability and validity but more study is needed. 3. EMG(E I) may be helpful to detect the segment of physical rest and exclude artifacts but more study is needed.

  • PDF

Thickness of the Macula, Retinal Nerve Fiber Layer, and Ganglion Cell-inner Plexiform Layer in the Macular Hole: The Repeatability Study of Spectral-domain Optical Coherence Tomography

  • Lee, Woo Hyuk;Jo, Young Joon;Kim, Jung Yeul
    • Korean Journal of Ophthalmology
    • /
    • 제32권6호
    • /
    • pp.506-516
    • /
    • 2018
  • Purpose: We measured the thicknesses of the ganglion cell and inner plexiform layer (GCIPL), the macula, and the retinal nerve fiber layer (RNFL) using spectral-domain optical coherence tomography in patients with idiopathic macula holes to analyze the repeatability of these measurements and compare them with those of the fellow eye. Methods: We evaluated 85 patients who visited our retinal clinic. The patients were divided into two groups according to their macular hole size: group A had a size of $<400{\mu}m$, while group B had a size of ${\geq}400{\mu}m$. Repeatability was determined by comparing the thicknesses of the GCIPL, macula, and RNFL with those of the normal fellow eye. Results: The average central macular thickness in patients with macular holes was significantly thicker than that in the normal fellow eye ($343.8{\pm}78.6$ vs. $252.6{\pm}62.3{\mu}m$, p < 0.001). The average thickness of the GCIPL in patients with macular holes was significantly thinner than that in the normal fellow eye ($56.1{\pm}23.4$ vs. $77.1{\pm}12.8{\mu}m$, p < 0.001). There was no significant difference in the average RNFL thickness between eyes with macular holes and fellow eyes ($92.4{\pm}10.0$ vs. $95.5{\pm}10.7{\mu}m$, p = 0.070). There were also no significant differences in the thicknesses of the GCIPL and RNFL among the two groups (p = 0.786 and p = 0.516). The intraclass correlation coefficients for the macula and RNFL were 0.994 and 0.974, respectively, in patients with macular holes, while that for the GCIPL was 0.700. Conclusions: Macular contour change with macular hole results in low repeatability and a tendency of thinner measurement regarding GCIPL thickness determined via spectral-domain optical coherence tomography. The impact of changes in the macular shape caused by macular holes should be taken into consideration when measuring the GCIPL thickness in patients with various eye diseases such as glaucoma and in those with neuro-ophthalmic disorders.

암석시험편 유효공극률 측정의 반복성과 재현성 (Repeatability and Reproducibility in Effective Porosity Measurements of Rock Samples)

  • 이태종;이상규
    • 지구물리와물리탐사
    • /
    • 제15권4호
    • /
    • pp.209-218
    • /
    • 2012
  • 다양한 직경과 길이, 암종, 그리고 유효공극률을 가지는 8종의 암석시험편에 대하여 반복적으로 고체밀도와 유효공극률을 산출하고 그에 따른 반복성 및 재현성을 검토하였다. 또한 대기의 기온변화가 유효공극률의 산출에 미치는 영향에 대해 고찰하였다. 8종의 암석시험편에 대하여, 진공압력은 사용한 시스템의 최대진공인 1 torr로, 진공시간은 ISRM 표준시험법의 규약을 만족하는 80분으로 하여 유효공극률을 7번씩 산출하였다. 즉, 참조를 위해 각각의 시험편에 대해 1회, 반복성 검토를 위하여 모든 실험 조건을 같이한 상태에서 각 3회씩, 그리고 재현성의 검토를 위하여 동시에 수침진공하는 시험편의 숫자를 2, 4, 8개로 달리하여 3회 등 총 7번씩의 유효공극률을 산출하고 비교 검토하였다. 고체밀도의 경우 8개 암석시험편의 평균편차가 0.00 $g/cm^3$으로 나타나서 완벽한 반복성과 재현성을 보였다. 유효공극률의 경우는 모든 실험 조건을 동일하게 한 반복성 실험에서는 평균편차가 0.07% 이하, 실험 조건 중에 수침진공 하는 시험편의 숫자를 달리한 재현성 실험에서는 0.05% 이하로 모두 양호한 값을 나타내었다. 재현성 실험에 의해 측정된 유효공극률이 대부분 반복성 실험에서 측정되는 편차범위 내에서 측정되어 양호한 재현성을 보였다. 따라서, 암석시험편의 개수를 2, 4, 8개로 달리하며 수침진공 한 재현성 실험에서는 표준시험법에 따라서 1 torr 정도의 고진공을 사용하는 경우에는 여러 개의 시료를 동시에 수침진공하여도 산출되는 유효공극률에는 영향을 미치지는 않는다. 온도, 습도, 현지기압 등 기상자료와 시험편의 물속무게를 비교하고 대기 온도가 물의 온도, 밀도 및 부력에 영향을 주어 결국 시험편의 물속무게를 잘못 평가할 수 있음을 보였다. 따라서 시험편의 유효공극률을 정교하게 산출하기 위해서는 시험편의 물속무게를 측정할 때 물의 온도를 실험조건에 포함시키거나 다른 물리량과 함께 측정하여 물의 밀도 변화에 따른 물속무게 변화를 보정하여야 더 정밀한 유효공극률을 산출이 가능할 것이다.

THE EFFECT OF THE REPEATABILITY FILE IN THE NIRS EATTY ACIDS ANALYSIS OF ANIMAL EATS

  • Perez Marin, M.D.;De Pedro, E.;Garcia Olmo, J.;Garrido Varo, A.
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.4107-4107
    • /
    • 2001
  • Previous works have shown the viability of NIRS technology for the prediction of fatty acids in Iberian pig fat, but although the resulting equations showed high precision, in the predictions of new samples important fluctuations were detected, greater with the time passed from calibration development to NIRS analysis. This fact makes the use of NIRS calibrations in routine analysis difficult. Moreover, this problem only appears in products like fat, that show spectrums with very defined absorption peaks at some wavelengths. This circumstance causes a high sensibility to small changes of the instrument, which are not perceived with the normal checks. To avoid these inconveniences, the software WinISI 1.04 has a mathematic algorithm that consist of create a “Repeatability File”. This file is used during calibration development to minimize the variation sources that can affect the NIRS predictions. The objective of the current work is the evaluation of the use of a repeatability file in quantitative NIRS analysis of Iberian pig fat. A total of 188 samples of Iberian pig fat, produced by COVAP, were used. NIR data were recorded using a FOSS NIRSystems 6500 I spectrophotometer equipped with a spinning module. Samples were analysed by folded transmission, using two sample cells of 0.1mm pathlength and gold surface. High accuracy calibration equations were obtained, without and with repeatability file, to determine the content of six fatty acids: miristic (SECV$\sub$without/=0.07% r$^2$$\sub$without/=0.76 and SECV$\sub$with/=0.08% r$^2$$\sub$with/=0.65), Palmitic (SECV$\sub$without/=0.28 r$^2$$\sub$without/=0.97 and SECV$\sub$with/=0.24% r$^2$$\sub$with/=0.98), palmitoleic (SECV$\sub$without/=0.08 r$^2$$\sub$without/=0.94 and SECV$\sub$with/=0.09% r$^2$$\sub$with/=0.92), Stearic (SECV$\sub$without/=0.27 r$^2$$\sub$without/=0.97 and SECV$\sub$with/=0.29% r$^2$$\sub$with/=0.96), oleic (SECV$\sub$without/=0.20 r$^2$$\sub$without/=0.99 and SECV$\sub$with/=0.20% r$^2$$\sub$with/=0.99) and linoleic (SECV$\sub$without/=0.16 r$^2$$\sub$without/=0.98 and SECV$\sub$with/=0.16% r$^2$$\sub$with/=0.98). The use of a repeatability file like a tool to reduce the variation sources that can disturbed the prediction accuracy was very effective. Although in calibration results the differences are negligible, the effect caused by the repeatability file is appreciated mainly when are predicted new samples that are not in the calibration set and whose spectrum were recorded a long time after the equation development. In this case, bias values corresponding to fatty acids predictions were lower when the repeatability file was used: miristic (bias$\sub$without/=-0.05 and bias$\sub$with/=-0.04), Palmitic (bias$\sub$without/=-0.42 and bias$\sub$with/=-0.11), Palmitoleic (bias$\sub$without/=-0.03 and bias$\sub$with/=0.03), Stearic (bias$\sub$without/=0.47 and bias$\sub$with/=0.28), oleic (bias$\sub$without/=0.14 and bias$\sub$with/=-0.04) and linoleic (bias$\sub$without/=0.25 and bias$\sub$with/=-0.20).

  • PDF

볼나사 구동 리니어 스테이지의 마그네틱 센서 위치결정 실험 (The Position Decision Experiment of Magnetic Sensor in Ball-screw Driven Linear Stage)

  • 차영엽
    • 제어로봇시스템학회논문지
    • /
    • 제19권1호
    • /
    • pp.10-14
    • /
    • 2013
  • High precision machining technology has become one of the important parts in the development of a precision machine. Such a machine requires high precision positioning as well as high speed on a large workspace. For machining systems having a high precision positioning with a long stroke, it is necessary to examine the repeatability of reference position decision. Though ball-screw driven linear stages equipped linear scale have high precision feed drivers and a long stroke, they have some limitations for reference position decision if they have not equipped the accurate home sensor. This study is performed to experimentally examine the repeatability for home position decision of a magnetic sensor as a home switch of ball-screw driven linear stage by using capacitance probe.

손 힘 사용 측정 FSA 시스템의 성능 평가 (Evaluation of the FSA Hand Force Measurement System)

  • 정기효;유희천;권오채
    • 대한인간공학회지
    • /
    • 제24권2호
    • /
    • pp.45-49
    • /
    • 2005
  • The FSA(Force Sensitive Application) system measures hand force by using force resistance sensors. Compared to conventional hand force measurement systems such as Lafayette hand dynamometer and Jamar hydraulic hand dynamometer, the FSA system can be applied to analyze use of hand forces while the hand is manipulating objects for a task, However, the measurement performance of the FSA system has not been objectively evaluated. The present study tested the FSA system in terms of stability, repeatability, accuracy, and linearity. It is shown that the FSA system has good stability (CV$\leq$0.02) and linearity($R^2$=0.82), but has low repeatability(CV=$0.11{\sim}0.19$) and accuracy(22% of underevaluation on average). This performance result indicates that measurements from the FSA system should be used for relative comparison rather than for absolute comparison.

홀 센서와 포토 센서를 이용하는 선형 스테이지에서 위치결정 비교 실험 (The Position Decision Comparison Experiment of Hall and Photo Sensors in the Linear Stage)

  • 차영엽
    • 제어로봇시스템학회논문지
    • /
    • 제21권2호
    • /
    • pp.157-161
    • /
    • 2015
  • For machining systems having a high precision positioning with a long stroke, it is necessary to examine the repeatability of reference position decisions. Though ball-screw driven linear stages equipped with encoders have high precision feed drivers and a long stroke, they have some limitations for reference position decisions if they have not been equipped accurate home sensors. High precision machining technology has become one of the most important aspects of the development of a precision machine. Such a machine requires high precision positioning as well as high speed on a large workspace. This study is performed to experimentally compare the repeatability for home position decisions in the case of photo sensors and hall sensors as a home switch of the ball-screw driven linear stage.