Abstract
The FSA(Force Sensitive Application) system measures hand force by using force resistance sensors. Compared to conventional hand force measurement systems such as Lafayette hand dynamometer and Jamar hydraulic hand dynamometer, the FSA system can be applied to analyze use of hand forces while the hand is manipulating objects for a task, However, the measurement performance of the FSA system has not been objectively evaluated. The present study tested the FSA system in terms of stability, repeatability, accuracy, and linearity. It is shown that the FSA system has good stability (CV$\leq$0.02) and linearity($R^2$=0.82), but has low repeatability(CV=$0.11{\sim}0.19$) and accuracy(22% of underevaluation on average). This performance result indicates that measurements from the FSA system should be used for relative comparison rather than for absolute comparison.
Keywords
FSA system; Hand force measurement; Performance evaluation; Musculoskeletal disorders;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Putz-Anderson, V., Cumulative Trauma Disorders: A Manual for Musculoskeletal Diseases of the Upper Limbs. Taylor & Francis: New York, 1988
2 Quam, D., Williams, G., Agnew, J. and Browne, P., An experimental determination of human hand accuracy with a dataglove. In Proceedings of the Human Factors Society 33rd Annual Meeting. Human Factors Society, Santa Monica, Calif., 315-319, 1989
3 Wise, S., Gardner, W., Sabelman, E., Valainis, E., Wong, Y., Glass, K., Drace, J. and Rosen, J., Evaluation of a fiber optic glove for semi-automated goniometric measurements. J. Rehab. Res. Devel., 27(4), 411-424, 1990   DOI   ScienceOn
4 Yun, M. H., A Hand Posture Measurement System for the Analysis of Manual Tool Handling Tasks. Unpublished doctoral dissertation, Pennsylvania State University, Pennsylvania, 1994
5 Ayoub, M. A., Ergonomic deficiencies: I. Pain at work. Journal of Occupational Medicine, 32(1), 52-57, 1990   DOI
6 AboutTime, Introduction about AboutTime. Retrived April 1, 2004 from http://www.arachnoid.com/abouttime/, 2004
7 Kessler, G. D., Hodges, L. F. and Walker, N., Evaluation of the cyberglove as a whole-hand input device. ACM Transactions on Computer-Human Interface, 2(4), 263-283, 1995   DOI   ScienceOn
8 NK BioTechnical Corporation, NK Dynamometer User's Manual, 2003
9 National Institute for Occupational Safety and Health (NIOSH), Musculoskeletal Disorders (MSDs) and Workplace Factors: A Critical Review of Epidemiologic Evidence for Work-Related Musculoskeletal Disorders of the Neck, Upper Extremity, and Low Back (2nd printing). Cincinnati, OH: U.S. Department of Health and Human Services (DHHS), 1997
10 NexGen, FSA glove pressure mapping system. Retrieved April 1, 2004 from http://www.nexgenergo.com/ergonomics/fsaglove.html, 2004