• 제목/요약/키워드: Repair techniques

검색결과 369건 처리시간 0.034초

Laboratory Simulation of Corrosion Damage in Reinforced Concrete

  • Altoubat, S.;Maalej, M.;Shaikh, F.U.A.
    • International Journal of Concrete Structures and Materials
    • /
    • 제10권3호
    • /
    • pp.383-391
    • /
    • 2016
  • This paper reports the results of an experimental program involving several small-scale columns which were constructed to simulate corrosion damage in the field using two accelerated corrosion techniques namely, constant voltage and constant current. A total of six columns were cast for this experiment. For one pair of regular RC columns, corrosion was accelerated using constant voltage and for another pair, corrosion was accelerated using constant current. The remaining pair of regular RC columns was used as control. In the experiment, all the columns were subjected to cyclic wetting and drying using sodium chloride (NaCl) solution. The currents were monitored on an hourly interval and cracks were visually checked throughout the test program. After the specimens had suffered sufficient percentage steel loss, all the columns including the control were tested to failure in compression. The test results generated show that accelerated corrosion using impressed constant current produces more corrosion damage than that using constant voltage. The results suggest that the constant current approach can be better used to simulate corrosion damage of reinforced concrete structures and to assess the effectiveness of various materials, repair strategies and admixtures to resist corrosion damage.

아연 전기 도금 강의 환경친화적인 화성처리 기술 개발 (Development of chemical conversion coating technology by environment friendly method for Zn electroplated steel)

  • 김성종;김정일;장석기
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.271-272
    • /
    • 2006
  • Zinc confers high corrosion resistance by acting as a sacrificial anode, and a zinc coating improves the appearance of steel. Chromate conversion coating (CCC) films are still one of the most efficient surface treatments for steel. Although such films can self-repair via the dissolution of Cr(VI), dissolved Cr(VI) have adverse effects on humans, and the environment. Therefore, we examined the corrosion protection property and morphology of colloidal silica conversion films as an alternative to CCC films. The corrosion behavior was investigated in 3% NaCl solution using electrochemical techniques, including electrochemical impedance spectroscopy, open circuit potential, and the salt spray test(SST). Corrosion was implied by the appearance of red rust on the specimen surface. In corrosion resistance at 3% NaCl solution, red rust appeared at 15-20, 55-70, and 83-98 days on Zn-electroplated steel, colloidal silica conversion-coated specimens, and CCC-coated specimens, respectively. In the salt spray test, the colloidal silica film provided better corrosion protection than CCC films, i.e., red rust appeared at 96 hours on the Zn-electroplated steel sheet, at 432 hours with the CCC films, and at 888 hours with silica conversion coating.

  • PDF

보행자모델 시뮬레이션을 활용한 건강검진센터 행위자 효율성 평가에 관한 연구 (A Study on the Agent Efficiency Evaluation of Health Examination Centers Using Pedestrian Model Simulation)

  • 윤소희;권현주;김석태
    • 한국멀티미디어학회논문지
    • /
    • 제21권4호
    • /
    • pp.499-512
    • /
    • 2018
  • The application of analytical techniques for the rational determination of problems arising from management science and corporate management. In a way that is the opposite of the repair plan that can predict accurate results is increasing utilization of the complex-based analysis methodology. In this study, we examined the application of physical space and the methodological utilization of the pedestrian model analysis that applied the simulation to the Health Checkup Center. The conclusions are as follows. First, the spatial analysis and measurement for empirical research has confirmed that the efficiency assessment through the pedestrian model simulation can lead to an objective evaluation. Second, it seems to be able to reduce the queue through a change in the number of services of the low-pressure and the hearing laboratory, the recovery room with a high proportion of male disturbances and relatively long use time. The third, the spatial density analysis and the time required to reduce the density change in comparative analysis, and the spatial layout changes, the increase in the capacity of 80 people, approximately 16 minutes to shorten the process duration.

Treatment of a Traumatic Leptomeningeal Cyst in an Adult with Fibrinogen-Based Collagen

  • Kim, Hoon;Jo, Kwang Wook
    • Journal of Korean Neurosurgical Society
    • /
    • 제53권5호
    • /
    • pp.300-302
    • /
    • 2013
  • Reports of traumatic leptomeningeal cysts (TLMC) are rare in adults. The standard treatment approach is craniectomy with careful exposure of the intact dural edges, followed by duroplasty. However, occasionally, the location of the TLMC makes achieving watertight duroplasty impossible. Herein, we report the case of a 28-year-old male who presented with a soft growing mass on the vertex of his head 16 months after the head trauma. Upon enhanced CT examination, a bony defect involving both the inner and outer table of the cranium was observed close to the sagittal sinus, and a well-defined cystic mass, 5 cm in diameter, was nested within the defect. The risks associated with extension craniotomy were high because the lesion was located superficial to the sagittal sinus, we opted to use fibrinogen-based collagen fleece (TachoCombR$^{(R)}$) to repair the dural defect. Two months after surgery, the patient remained asymptomatic with a good cosmetic result. In cases like ours, when the defect is near the major sinuses and the risk of rupturing the sinus during watertight dural closure is high, fibrinogen-based collagen fleece (TachoCombR$^{(R)}$) is an effective alternative approach to standard dural suture techniques.

Optical Biopsy of Peripheral Nerve Using Confocal Laser Endomicroscopy: A New Tool for Nerve Surgeons?

  • Crowe, Christopher S;Liao, Joseph C;Curtin, Catherine M
    • Archives of Plastic Surgery
    • /
    • 제42권5호
    • /
    • pp.626-629
    • /
    • 2015
  • Peripheral nerve injuries remain a challenge for reconstructive surgeons with many patients obtaining suboptimal results. Understanding the level of injury is imperative for successful repair. Current methods for distinguishing healthy from damaged nerve are time consuming and possess limited efficacy. Confocal laser endomicroscopy (CLE) is an emerging optical biopsy technology that enables dynamic, high resolution, sub-surface imaging of live tissue. Porcine sciatic nerve was either left undamaged or briefly clamped to simulate injury. Diluted fluorescein was applied topically to the nerve. CLE imaging was performed by direct contact of the probe with nerve tissue. Images representative of both damaged and undamaged nerve fibers were collected and compared to routine H&E histology. Optical biopsy of undamaged nerve revealed bands of longitudinal nerve fibers, distinct from surrounding adipose and connective tissue. When damaged, these bands appear truncated and terminate in blebs of opacity. H&E staining revealed similar features in damaged nerve fibers. These results prompt development of a protocol for imaging peripheral nerves intraoperatively. To this end, improving surgeons' ability to understand the level of injury through real-time imaging will allow for faster and more informed operative decisions than the current standard permits.

견봉 쇄골 탈구와 쇄골 외측단 골절에서 일시적 오구 쇄골간 나사못 고정술 (Coracoclavicular Screw Fixation for AC Dislocation and Unstable Distal Clavicle Fracture)

  • 김진섭;전진호;정영기
    • Clinics in Shoulder and Elbow
    • /
    • 제2권2호
    • /
    • pp.133-137
    • /
    • 1999
  • Purpose: There are so many different methods with the their own advantages and disadvantages for acute AC dislocation and distal unstable clavicle fracture. We evaluated the usefulness of temporary Bosworth's coracoclavicular fixations using the cannulated screw and reviewed our clinical results. Materials and Methods: We evaluated 34 cases of temporary coracoclavicular fixations with cannulated screw and washer for acute AC dislocation(25cases in the Type V, Ⅲ) and distal unstable clavicle fracture(9cases in the Type ⅡB, Ⅱ+Ⅲ). All cases were fixed by the same techniques, guided cannulated screw under C-arm after the repair of the CC ligament within 1 week. Bases on the regular check, screws were removed at the 6-12 weeks under local anesthesia. The final clinical and radiological results(average 14 months follow-up) were rated with the UCLA scale. Results : All shoulders were gained nearly full ROM passively at the 3-4 weeks. The overall satisfactory resuIts(excellent or good) were achieved 88%(22/25) in the acute AC dislocation and all in the distal unstable clavicle fracture. There were no definite complications except three initial fixations loosening. Conclusion: Temporary Bosworth's coracoclavicular fixation using the cannulated screw with guided pin was simple precedure and provided enough initial stability for acute AC dislocation and distal unstable clavicle fracture.

  • PDF

Ultrasonics and electromagnetics for a wireless corrosion sensing system embedded in structural concrete

  • Hietpas, K.;Ervin, B.;Banasiak, J.;Pointer, D.;Kuchma, D.A.;Reis, H.;Bernhard, J.T.
    • Smart Structures and Systems
    • /
    • 제1권3호
    • /
    • pp.267-282
    • /
    • 2005
  • This work describes ongoing development of an embedded sensor system for the early detection and prevention of deterioration of reinforcing steel tendons within reinforced concrete. These devices will evaluate the condition of the steel tendon using ultrasonic techniques and then wirelessly transmit this data to the outside world without human intervention. The ultrasonic transducers and the interpretation of the sensed signals that allow detection and prognosis of tendon condition are detailed. Electrical characterization of concrete mixtures used in bridge construction is conducted and a wideband microstrip antenna is designed and fabricated to operate between 2.4 and 2.5 GHz when embedded in such a medium. Simulations and measurements of the embedded antenna element are presented. Transceiver selection and implementation are discussed as well as future work in operational protocols, sensor networking, and power sources. By implementing commercially available off-the-shelf components whenever possible, these devices have the potential to save millions of dollars a year in evaluation, repair and replacement of reinforced concrete.

기관피부누공에 대한 임상적 고찰 (Clinical Study of Tracheocutaneous Fistula)

  • 이형석;김현수;심봉택;태경;박철원
    • 대한기관식도과학회지
    • /
    • 제1권1호
    • /
    • pp.142-145
    • /
    • 1995
  • The tracheocutaneous fistula(TCF) may develop infrequently as a complication after tracheostomy. Prolonged tracheostomy tube dependence increases the risk of TCF developing, and in growth of stratified squamous epithelium lines the furrow connecting the tracheal mucosa and the skin, accounting for persistence of the fistulous tract. Such fistulas are a nuisance and create nursing and social problems including poor hygiene, aspiration, difficulty with speech, and depletion of pulmonary reserve. Surgical closure has generally been successful by primary closure, fistulectomy with primary closure, and closure by secondary intention following excision of the tracheocutaneous fistula. No large series compares the efficacy of these techniques and each has its own merits. Recent literature has purposed to minimizing complications. For ten years, from January 1985 to December 1994, the authors experienced 25 cases of TCF which were analyzed in respect to incidence and interval of cannulation, duration between decanulation and fistular closure, precedent disease, closure methods, and complications of TCF repair.

  • PDF

An IC Chip of a Cell-Network Type Circuit Constructed with 1-Dimensional Chaos Circuits

  • Eguchi, Kei;Ueno, Fumio;Zhu, Hongbing;Tobata, Toru;Ootani, Yuri
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -3
    • /
    • pp.2000-2003
    • /
    • 2002
  • In this paper, an IC chip of a cell- network type circuit constructed with 1-dimensional chaos circuits is reported. The circuit, is designed by sing switched-current (Sl) techniques. In the proposed circuit, by controlling connections of cells, an S- dimensional circuit (S = 1, 2, 3,…) and a synchronization system can be constructed easily. Furthermore, in spite of faults of a few cells, the circuit can reconstruct above-mentioned systems only to change connections of cells. This feature will open up new vista for engineering applications which are used in a distance place such as space, deep sea, etc. since it is difficult to repair faults of these application systems. To investigate the characteristics of the circuit, SPICE simulations are performed. The VLSI chip is fabricated from the layout design using a CAD tool, MAGIC. The proposed circuit is integrable by a standard 1.2 $\mu\textrm{m}$ CMOS technology.

  • PDF

Strengthening of reinforced concrete beams with epoxy-bonded perforated steel plates

  • Aykac, Sabahattin;Kalkan, Ilker;Uysal, Ali
    • Structural Engineering and Mechanics
    • /
    • 제44권6호
    • /
    • pp.735-751
    • /
    • 2012
  • Although being one of the most popular strengthening techniques in reinforced concrete beams, the use of steel plates bonded to the soffit raises problems of ductility. This study aims at investigating the influence of the use of perforated steel plates instead of solid steel plates on the ductility of reinforced concrete beams. A total of nine reinforced concrete beams were tested. In addition to an unplated beam, eight beams with perforated steel plates of two different thicknesses (3 mm and 6 mm) were subjected to monotonic loading. Effect of bonding the plates to the beams with anchor bolts and with additional side plates bonded to the sides of the beam with and without anchors is also investigated. The use of bolts in addition to epoxy was found to greatly contribute to the ductility and energy absorption capacity of the beams, particularly in specimens with thick plates (6 mm) and the use side plates in addition to the bottom plate was found to be ineffective in increasing the ductility of a concrete beam unless the side plates are attached to the beam with anchors bolts. The thickness of the plate was found to have little effect on the bending rigidity of the beam.