• Title/Summary/Keyword: Renewable energy system

Search Result 2,432, Processing Time 0.036 seconds

A Study on Configuration of Small Wind Turbines for Maximum Capacity of Wind Power Systems Interconnected With a Building (빌딩 내 최대 풍력발전설비 연계를 위한 소형풍력발전원 구성에 관한 연구)

  • Lee, Yeo-Jin;Kim, Sung-Yul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.4
    • /
    • pp.605-612
    • /
    • 2017
  • One of the biggest environmental issues that our world has been facing is climate change. In order to cope with such environmental issues, the world is putting a great deal of effort into energy conservation. The building sector, in particular, consumes 36% of the energy consumed worldwide and emits considerable amount of greenhouse gases. Therefore, introduction of renewable energies in the building sector is highly recommended. Renewable energy sources that can be utilized in the building sector include sunlight, solar heat, geothermal heat, fuel cells and wind power. The wind power generation system which converts wind energy into electrical energy has advantages in that wind is an unlimited and pollution-free resource. It is suitable to be connected to existing buildings because many years of operational experience and the enhanced stability of the system have made it possible to downsize the electrical generator. In case of existing buildings, it is necessary to consider the live loads of the buildings to connect the wind power generation system. This paper, through the connection of the wind power generation with existing buildings, promotes reduction of greenhouse gas emissions and energy independence by reducing energy consumption in the building sector. In order to connect the wind power generation system with an exciting building, the live load of the building and the area of the rooftop should be considered. The installable model is selected by comparing the live load of the building and the load of the wind power generation system. The maximum number of the wind turbines that can be installed is obtained by considering the separation distance between the wind turbines within the area of the rooftop. Installations are divided into single installations and multiple installations of two different types of wind turbines. After determining the maximum installable number, the optimal model that can achieve the maximum annual power generation will be selected by comparing the respective total annual amount of the power generation of different models.

Energy Big Data Pre-processing System for Energy New Industries (에너지신산업을 위한 에너지 빅데이터 전처리 시스템)

  • Yang, Soo-Young;Kim, Yo-Han;Kim, Sang-Hyun;Kim, Won-Jung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.5
    • /
    • pp.851-858
    • /
    • 2021
  • Due to the increase in renewable energy and distributed resources, not only traditional data but also various energy-related data are being generated in the new energy industry. In other words, there are various renewable energy facilities and power generation data, system operation data, metering and rate-related data, as well as weather and energy efficiency data necessary for new services and analysis. Energy big data processing technology can systematically analyze and diagnose data generated in the first half of the power production and consumption infrastructure, including distributed resources, systems, and AMI. Through this, it will be a technology that supports the creation of new businesses in convergence between the ICT industry and the energy industry. To this end, research on the data analysis system, such as itemized characteristic analysis of the collected data, correlation sampling, categorization of each feature, and element definition, is needed. In addition, research on data purification technology for data loss and abnormal state processing should be conducted. In addition, it is necessary to develop and structure NIFI, Spark, and HDFS systems so that energy data can be stored and managed in real time. In this study, the overall energy data processing technology and system for various power transactions as described above were proposed.

Develolpment of Heat Exchanger for the Humidifier of 3MW MCFC (3MW급 MCFC용 가습기 개발)

  • Kim, Seonhwa;Oh, Yongmin;Kim, Jaesig;Lee, Jeajun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.88.1-88.1
    • /
    • 2010
  • In recent days, the study for the renewable energy is required to supplement traditional energy source. One of the renewable energy of Fuel Cell is classified according to the electrolytes. It is the MCFC (Molten Carbonate Fuel Cell) for this study. One of the equipments of the heat exchangers is important component for efficiency and cost. In MCFC system, several heat exchangers are used according to the application. It is named for the humidifier because it is to preheat the fuel and water so that a reactor will convert some of the incoming fuel to hydrogen. Then, hot side fluid service is used the exhausted gas from the fuel cell and cold side fluid service is the fuel and water. The operation temperature range is about 25~500 Celsius Degree. This heat exchanger has the problems of heat transfer considering to multiphase fluid and phase changing. So it is necessary to analyze the heat transfer characteristics and to propose the reasonable design methodology for the humidifier. In this study, the thermal characteristic for the humidifier is estimated by using commercial tool of heat exchanger design and rating. And this study provides the testing methodology and presents the results for test facility of fabrication and for testing.

  • PDF

Energy self-sufficient electrolysis apparatus for sterilization of portable toilet in small vessels (소형선박에 설치 가능한 해상기인 오염원 멸균용 에너지 자급형 전기분해 장치 개발)

  • Oh, Seung-Won;Hahn, Min-Soo;Choi, Hae-Wook
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.48 no.3
    • /
    • pp.269-276
    • /
    • 2012
  • Marine caused pollution occurs mostly near coastal area and its main cause was known to be human feces issued from small vessels. To sterilize liquid pollutants from portable toilets of small vessels, an electrolysis treatment is judged to be the most economic and stable method considering an environment of its use. In this paper, we presents an electrolysis apparatus which is the most appropriate for sterilizing pollutants from portable toilets of small vessels and derives the minimum operating time of the apparatus for sterilizing norovirus which is a main target of marine caused pollution sources. In order to utilize renewable energy, we designed an apparatus which generates a renewable energy from solar cells. As a result, we could confirm the applicability of the proposed system with the results from experiments in three cases of different weather conditions.

Utililty-Interfaced High-Frequency Flyback Transformer Linked Sinewave Pulse Modulated Inverter for a Small Scale Renewable Energy Conditioner

  • Chandhaket, Srawouth;Koninish, Yoshihiro;Nakaoka, Mutsou
    • Journal of Power Electronics
    • /
    • v.2 no.2
    • /
    • pp.112-123
    • /
    • 2002
  • This paper presents a novel prototype of the utility AC power interfaced soft-switching sinewave pulse modulated inverter using the high-frequency flyback for the small scale distributed renewable energy power conditioner. The proposed cricuit with a high-frequency isolation link has a funtion of electrical isolation, which is more cost-effective and reliable for the small-scale distributed renwal energy utilization system from a safety point of riew. The discontinuous conduction mode(DCM) operation of the high-frequency flyback transformer is adopted to establish a simple and low-cost circuit configuration and control scheme. For the simplicity, the circuit operating principle is described on the basis of the modified conventional full bridge inverter, whitch is the typical conventional high-frequency full-bridge inverter employing the high requency flyback transformer to eanble the effictive function of the electrical isolation. Than, the new circuit topology of the unility-interfaced soft-switching sinewave pulse modulated inverter using IGBTs is proposed. The proposed cricuit topology is additionally composed of the auxiliary power regenerating snubber cricuits, which are also mathematically analyzed for the parameter desigen settings. Finally, the performance of the propose inverter is evaluated on the basis of computer-aid simulation. It is noted that the sinewave pulse modulated output current of the inverter is synchronous to the AC main voltage.

The Study on the Method of Distribution of output according to Power Limit of Renewable Energy (재생에너지 출력제한에 따른 출력량 배분 방안 연구)

  • Myung, Ho-San;Kim, Se-Ho
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.173-180
    • /
    • 2019
  • There is a case where the output of renewable energy(RE) is curtailed due to an increase in the share of RE. Typically, wind power(WP) is curtailed due to oversupply and low load at midnight. However there is a case where the output of WP is limited during daytime due to the increase in share of photovoltaic(PV). In current electricity market, as the share of PV is increased, the curtailments of WP will be increased further, which will add to the difficulties of wind farm operators. In this paper, we propose a method to distribute the power limit of RE according to the criterion based on the priority constraint of the energy source which is difficult to operate the power system.

Critical Issues in Assessing Feed-In Tariffs of Electricity from New and Renewable Energies (신.재생에너지이용 발전전력 기준가격 산정에서의 쟁점)

  • Kim, Eun-Il;Kim, Keon-Hoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.87-90
    • /
    • 2008
  • Levelized generation cost(LGC) has been widely used in assessing feed-in tariffs(FiT) for electricity generating from new and renewable energies. Current FiTs for renewable electricity in Korea have been fixed and applied with realistic economic data by the efforts of KERI(Korea Electrotechnology Research Institute) since October 2006. Some critical issues on the estimation of LGC are, however, found in KERI's report. Major issues are the estimation of capital cost, the consideration of corporate tax, and the application of economic life cycle in the formulae for LGC. These critical issues are examined and interpreted in a correct way in this paper.

  • PDF

A Study on the Output Power Enhancement of GaAs/AlGaAs Solar Cell using Concentration Method (집광에 의한 GaAs/AlGaAs태양전지의 출력 증대 연구)

  • Lee, Dong-Ho;Kim, Young-Hwan;Song, Jin-Dong;Kim, Seong-Il
    • New & Renewable Energy
    • /
    • v.5 no.3
    • /
    • pp.26-31
    • /
    • 2009
  • Using MBE growth method, GaAs/AlGaAs solar cell structure was grown. Deposited electrodes are Au/Ni/Ge for n-type and Au/Pt/Ti for p-type electrodes were deposited by E-beam evaporator. Indoor light concentrators were devised and fabricated in order to concentrate artificial solar rays. Also mirror and prism and Fresnel lens concentration system with solar simulator were devised and fabricated. Results of solar cell characteristics were measured with shutting system which can control the amount of light. Maximum power density was 2.13 W/$cm^2$ and maximum concentration was 124 sun, when mirror with Fresnel lens was used at $7854\;mm^2$ of shutter hole.

  • PDF

Economic analysis on Sustainable Photovoltaic Systems (지속가능한 태양광발전시스템의 경제성 분석)

  • Park, Soo-Uk;Lee, Deok-Ki
    • New & Renewable Energy
    • /
    • v.1 no.3 s.3
    • /
    • pp.35-41
    • /
    • 2005
  • This paper analyses the economics of grid-connected photovoltaic systems. With the 2003 cost of photovoltaic systems, under prevailing capital market conditions, with a system lifetime of 30 years, and under the best climatic conditions, it appears that the cost of production of grid-connected electricity could be of 0.21 US $/kWh, and under medium climatic conditions, European locations, Switzerland, Japan and South Korean could be of 0.28$/kWh. If the lifetime if the system goes up, due to future technological improvements, to a very large value such as 50 years, these costs can be lowered by 10-20%. Competitiveness of grid-connected photovoltaic electricity, while it still cannot be taken for granted, is a possibility, especially if major technological advances further lowers the costs of photo cells and increases their lifetimes.

  • PDF

Development of the Wind Power Forecasting System, KIER Forecaster (풍력발전 예보시스템 KIER Forecaster의 개발)

  • Kim Hyun-Goo;Lee Yung-Seop;Jang Mun-Seok;Kyong Nam-Ho
    • New & Renewable Energy
    • /
    • v.2 no.2 s.6
    • /
    • pp.37-43
    • /
    • 2006
  • In this paper, the first forecasting system of wind power generation, KIER Forecaster is presented. KIER Forecaster has been constructed based on statistical models and was trained with wind speed data observed at Gosan Weather Station nearby Walryong Site. Due to short period of measurements at Walryong Site for training the model, Gosan wind data were substituted and transplanted to Walryong Site by using Measure-Correlate-Predict(MCP) technique. The results of One to Three-hour advanced forecasting models are consistent with the measurement at Walryong site. In particular, the multiple regression model by classification of wind speed pattern, which has been developed in this work, shows the best performance comparing with neural network and auto-regressive models.

  • PDF