• Title/Summary/Keyword: Renewable energy plant

Search Result 468, Processing Time 0.028 seconds

A Study on Fault Characteristics of DFIG in Distribution Systems Based on the PSCAD/EMTDC (PSCAD/EMTDC를 이용한 풍력발전의 배전계통 사고특성에 관한 연구)

  • Son, Joon-Ho;Kim, Byung-Ki;Jeon, Jin-Taek;Rho, Dae-Seok
    • Journal of the Korea Convergence Society
    • /
    • v.2 no.2
    • /
    • pp.47-56
    • /
    • 2011
  • Korea Ministry of Knowledge Economy has estimated that wind power (WP) will be occupied 37% in 2020 and 42% in 2030 of the new energy sources, and also green energies such as photovoltaic (PV) and WP are expected to be interconnected with the distribution system because of Renewable Portfolio Standard (RPS) starting from 2012. However, when a large scale wind power plant (over 3[MW]) is connected to the traditional distribution system, protective devices (mainly OCR and OCGR of re-closer) will be occurred mal-function problems due to changed fault currents it be caused by Wye-grounded/Delta winding of interconnection transformer and %impedance of WP's turbine. Therefore, when Double-Fed Induction Generator (DFIG) of typical WP's Generator is connected into distribution system, this paper deals with analysis three-phase short, line to line short and a single line ground faults current by using the symmetrical components of fault analysis and PSCAD/EMTDC modeling.

$CO_2$ Separation in IGCC plant using Principles of Gas hydrate Formation (가스 하이드레이트 형성 원리를 이용한 IGCC 공정에서의 $CO_2$ 분리 연구)

  • Lee, Hyun Ju;Kim, Soo Min;Lee, Eun Kyung;Lee, Ju Dong;Kim, Yang Do
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.215.2-215.2
    • /
    • 2010
  • 지구온난화의 주범으로 알려진 $CO_2$의 대기 중 농도는 산업혁명 이전 280ppm에서 산업 혁명 이후 375ppm으로 증가하였다. 정부 간 기후변화패널(IPCC)의 기후변화 시나리오에 의하면, 지금부터 다양한 감축노력을 한다 할지라도 $CO_2$ 증가추세는 계속되어 2100년경에는 대기 중 $CO_2$농도가 600~950ppm에 이를 것으로 예측하고 있다. 현재까지 화력발전부분은 온실가스($CO_2$)의 최대 배출 원으로 알려져 있으며 이 분야의 $CO_2$ 회수기술은 연소 후 포집(Post-combustion), 순산소 연소(Oxy-fuel combustion), 연소 전 탈탄소화(Pre-combustion) 3가지로 크게 구분된다. 이중 석탄가스화복합발전(IGCC)기술과 연계하여 $CO_2$를 회수할 수 있는 방법이 연소 전 탈탄소화 기술이다. 핵심기술은 $CO_2$ 분리공정으로 적용 될 수 있는 기술로서는 흡착 흡수법, 막분리법 그리고 가스 하이드레이트가 있으나 아직까지 우리나라의 가스 하이드레이트 기술은 전무한 형편이다. 본 연구에서는 가스 하이드레이트 형성원리를 이용하여 정온 정압 조건에서 $CO_2/H_2$ 하이드레이트를 제조하였으며 특히, 하이드레이트 형성 촉진제인 TBAB(Tetra-n-butyl ammonium bromide)를 첨가하여 TBAB 농도에 따른 상평형 및 속도론 실험을 수행 하였다. 또한 라만 분석을 통하여 $CO_2$ 회수 분리에 대한 연구도 병행하였다.

  • PDF

A Study on the Safety Performance Evaluation Method of Blowers for 1kW Class Stationary Fuel Cell System (1kW급 건물용 연료전지시스템 블로워의 안전성능 평가방법에 관한 연구)

  • Lee, Jungwoon;Seo, Wonseok;Kim, Younggyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.127.2-127.2
    • /
    • 2010
  • 우리나라는 기후변화 대응을 준비하기위해 2008년도에 수립한'국가에너지기본계획(2008-2030)'에 따라 2030년까지 신재생에너지 비중을 2.4%에서 11%까지 달성을 목표로 정하고 신재생에너지 분야를 성장시키기 위해 국가기술개발 및 산업화 전략을 수립해 추진하고 있다. 이에 발맞추어 건물용 연료전지시스템의 경우, 2006년도부터 1kW급 가정용 연료전지시스템 모니터링 사업의 일환으로 3년간 210대가 도시가스사 및 지자체 등을 중심으로 설치되어 운전되어지고 있다. 특히, 2010년부터 시범보급사업이 추진되어 올해 200대를 시작으로 2011년에 300대, 2012년에 500대가 일반가정에 보급되어질 예정이다. 하지만 현재 6천만원인 연료전지시스템 가격을 실제 보급가능한 가격인 5백만원 이하로 저감시키는 것이 현 시점에서 가장 시급한 문제로 대두되어지고 있는 실정이다. 본 연구에서는 그린홈 보급확대를 위한 건물용 연료전지의 보조기기인 블로워의 가격저감을 위한 연구의 일환으로 블로워의 안전성능 평가방법을 개발하여 보조기기의 가격저감 및 안전성을 확보하고자 한다. 1kW급 건물용 연료전지시스템의 여러 블로워 중 도시가스용 연료승압 블로워, 선택산화 공기 블로워, 버너 공기 블로워 및 캐소드 공기 블로워의 안전성능 평가방법을 제시함으로서, 국내 블로워 제조사의 설계방향을 제시하고 연료전지시스템의 안전성을 확인하고자 한다. 특히, 내구성, 기밀, 가혹조건시험 및 소음, 진동, 습도, 온도와 같은 내주위환경시험 등의 평가결과를 제조사에 feedback하여 안전성능 개선에 이바지하고자 한다.

  • PDF

Test of Fault Detection to Solar-Light Module Using UAV Based Thermal Infrared Camera (UAV 기반 열적외선 카메라를 이용한 태양광 모듈 고장진단 실험)

  • LEE, Geun-Sang;LEE, Jong-Jo
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.19 no.4
    • /
    • pp.106-117
    • /
    • 2016
  • Recently, solar power plants have spread widely as part of the transition to greater environmental protection and renewable energy. Therefore, regular solar plant inspection is necessary to efficiently manage solar-light modules. This study implemented a test that can detect solar-light module faults using an UAV based thermal infrared camera and GIS spatial analysis. First, images were taken using fixed UAV and an RGB camera, then orthomosaic images were created using Pix4D SW. We constructed solar-light module layers from the orthomosaic images and inputted the module layer code. Rubber covers were installed in the solar-light module to detect solar-light module faults. The mean temperature of each solar-light module can be calculated using the Zonalmean function based on temperature information from the UAV thermal camera and solar-light module layer. Finally, locations of solar-light modules of more than $37^{\circ}C$ and those with rubber covers can be extracted automatically using GIS spatial analysis and analyzed specifically using the solar-light module's identifying code.

Design of Green Community Rediscovery Center with Community Gardens and Social Integration Functions (공동체정원과 사회통합기능이 있는 Green Community Rediscovery Center의 설계)

  • Lee, Eung-Jik;Lee, Hyung-Sook;Yoon, Eun-Ju;Ekpeghere, Kalu I.;Koh, Sung-Cheol
    • KIEAE Journal
    • /
    • v.11 no.4
    • /
    • pp.29-36
    • /
    • 2011
  • The aim of this study was to study the functions and roles of Green Community Rediscovery Center (GCRC) in terms of community integration, to design GCRC with various types of green roofs, and to investigate the possibility of applying a renewable energy system (e.g., PV) to the building greenery systems. The four major functional modules for GCRC were suggested: implementation of ecopark and community gardens with environmental education programs, implementation of green housing model with education programs, Discover Science Center, and implementation of green business model with education programs. Three major functions of the center are also presented in terms of design: 1) functions of community gardens; 2) establishment of a green business model, community composting system and an urban farming system; and 3) roles of community gardens in social interactions within GCRC. GCRC provides residents with the opportunities of community gardens, urban farming based on a successful recycling system, as well as a green business model and environmental education programs near their homes. The air temperature of the green roof (utilizing Sedum sarmentosum as a cover plant) was approximately $3^{\circ}C$ lower than that of the non-green roof, indicating a potential efficiency increase in PV systems for GCRC. It was concluded that the GCRC suggested would enhance the neighborhood satisfaction, improve the quality of life and contribute to social integration and community regeneration.

Optimal Voltage Control Algorithm of Small Hydro Generators for Voltage Stabilization in Distribution system with large scaled PV systems (대용량 태양광전원이 연계된 배전계통의 전압안정화를 위한 소수력발전기의 최적전압제어 알고리즘)

  • Choi, Hong-Yeol;Choi, Sung-Sik;Kang, Min-Kwan;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.7
    • /
    • pp.824-832
    • /
    • 2018
  • According to the government's policy to demonstrate and expand the renewable energy sources, distributed generators such as PV and WP are installed and operated in distribution systems. However, there are many issues related to power quality problems including over voltage and under voltage of customers. In order to overcome these problems, the electric power company have installed a step voltage regulator (SVR) in primary feeders interconnected with distributed generators, and also have established the technical guidelines for the distributed generators to stabilize the customer voltages in distribution systems. However, it is difficult to maintain the customer voltages within allowable limit. Therefore, this paper reviews the problems of voltage control by SVR in a distribution systems interconnected with a large amount of PV systems, and proposes characteristics of operating range and voltage control limit of the small hydropower generators. Also, with the estimation of the influence to the power system voltages from the voltage control mode of generators, this paper proposes the optimal voltage control algorithm of the small hydropower generators. By programming the proposed algorithm into control simulator of exciter, it is confirmed that the proposed algorithm can contribute the voltage stabilization in distribution systems interconnected with large scaled PV systems.

Development and Performance Test of SOFC Co-generation System for RPG (SOFC를 이용한 가정용 열병합 발전시스템 개발 및 성능시험)

  • Lee, Tae-hee;Choi, Jin-Hyeok;Park, Tae-Sung;Choi, Ho-Yun;Yoo, Young-Sung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.361-364
    • /
    • 2009
  • KEPRI has studied planar type SOFC stacks using anode-supported single cells and kW class co-generation systems for residential power generation. A 1kW class SOFC system consisted of a hot box part, a cold BOP part and a water reservoir. A hot box part contains a SOFC stack made up of 48 cells with $10{\times}10cm^2$ area and ferritic stainless steel interconnectors, a fuel reformer, a catalytic combustor and heat exchangers. Thermal management and insulation system were especially designed for self-sustainable operation. A cold BOP part was composed of blowers, pumps, a water trap and system control units. When a 1kW class SOFC system was operated at $750^{\circ}C$ with hydrogen, the stack power was 1.2kW at 30 A and 1.6kW at 50A. Turning off an electric furnace, the SOFC system was operated using hydrogen and city gas without any external heat source. Under self-sustainable operation conditions, the stack power was about 1.3kW with hydrogen and 1.2kW with city gas respectively. The system also recuperated heat of about 1.1kW by making hot water. Recently KEPRI developed stacks using $15{\times}15cm^2$ cells and tested them. KEPRI will develop a 5 kW class CHP system using $15{\times}15cm^2$ stacks by 2010.

  • PDF

Safety Performance Evaluation of Blowers for 1kW Class Stationary Fuel Cell System (1kW급 건물용 연료전지시스템 블로워의 안전성능 평가)

  • Lee, Jungwoon;Kim, Younggyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.90.2-90.2
    • /
    • 2011
  • 세계 각 국에서는 선진국을 중심으로 기후변화와 치솟는 유가에 대응하기 위하여 다양한 에너지원의 확보를 위해 부단히 노력하고 있다. 특히, 신재생에너지원 중 에너지 지속성이 가장 우수한 연료전지의 경우 1kW급 건물용 연료전지시스템이 도시가스 인프라가 가장 우수한 한국 및 일본을 중심으로 상용화에 가장 근접해 있는 실정이다. 일본의 경우 가정용 연료전지시스템 '에너팜'의 일부 제품이 올해부터 200만엔대로 가격을 내려 보급되어질 예정이고, 아직은 경제성이 떨어지지만 연료전지 조기 상용화를 위해 시스템 가격저감을 통한 기술개발이 한창이다. 또한 700W급 고체산화물형 연료전지시스템을 세계에서 처음 시판 계획을 가지고 있다. 국내의 경우 2009년도부터 시작된 '그린홈 보급확대를 위한 건물용 연료전지 보조기기 가격저감 기술개발'연구를 통해 블로워, 밸브, 유량계 및 펌프 등의 보조기기의 단가를 낮추고자 기술개발에 박차를 가하고 있다. 이에 따른 연료전지 부품 가격저감 기술이 국내 건물용 연료전지 시장보급의 활력소가 되기를 기대한다. 본 연구에서는 건물용 연료전지의 보조기기인 블로워의 가격저감을 위한 연구의 일환으로 블로워의 안전성능 평가를 통한 보조기기의 가격저감 및 안전성을 확보하고자 한다. 1kW급 건물용 연료전지시스템의 여러 블로워 중 도시가스용 연료승압 블로워, 선택산화 공기 블로워, 버너 공기 블로워 및 캐소드 공기 블로워의 안전성능 평가를 수행하였고, 평가결과의 공유를 통하여 국내 블로워 제조사의 설계방향을 제시하고 연료전지시스템의 안전성을 확인하고자 한다. 특히, 내구성, 기밀, 가혹조건시험 및 소음, 진동, 습도, 온도와 같은 내주위환경시험 등의 평가결과 비교를 통하여, 연료전지 부품 인증기준을 재정립하여 연료전지 부품산업의 조기 활성화를 도모하고자 한다.

  • PDF

Numerical Study on a Hydrogen Recirculation Ejector for Fuel Cell Vehicle (연료전지 수소재순환 이젝터 시스템에 관한 수치해석적 연구)

  • NamKoung, Hyuck-Joon;Moon, Jong-Hoon;Jang, Seock-Young;Hong, Chang-Oug;Lee, Kyoung-Hoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.156-160
    • /
    • 2007
  • Ejector system is a device to transport a low-pressure secondary flow by using a high-pressure primary flow. Ejector system is, in general, composed of a primary nozzle, a mixing section, a casing part for suction of secondary flow and a diffuser. It can induce the secondary flow or affect the secondary chamber pressure by both shear stress and pressure drop which are generated in the primary jet boundary. Ejector system is simple in construction and has no moving parts, so it can not only compress and transport a massive capacity of fluid without trouble, but also has little need for maintenance. Ejectors are widely used in a range of applications such as a turbine-based combined-cycle propulsion system and a high altitude test facility for rocket engine, pressure recovery system, desalination plant and ejector ramjet etc. The primary interest of this study is to set up an applicable model and operating conditions for an ejector in the condition of sonic and subsonic, which can be extended to the hydrogen fuel cell vehicle. Experimental and theoretical investigation on the sonic and subsonic ejectors with a converging-diverging diffuser was carried out. Optimization technique and numerical simulation was adopted for an optimal geometry design and satisfying the required performance at design point of ejector for hydrogen recirculation. Also, some sonic and subsonic ejectors with the function of changing nozzle position were manufactured precisely and tested for the comparison with the calculation results.

  • PDF

Economic Feasibility Study for Molten Carbonate Fuel Cells Fed with Biogas

  • Song, Shin-Ae;Han, Jong-Hee;Yoon, Sung-Pil;Nam, Suk-Woo;Oh, In-Hwan;Choi, Dae-Ki
    • Journal of Electrochemical Science and Technology
    • /
    • v.1 no.2
    • /
    • pp.102-111
    • /
    • 2010
  • Molten carbonate fuel cell (MCFC) power plants are one of most attractive electricity generation systems for the use of biogas to generate high-efficiency ultra-clean power. However, MCFCs are considerably more expensive than comparable conventional electricity generation systems. The commercialization of MCFCs has been delayed more than expected. After being effective in the Kyoto protocol and considerably increasing the fossil price, the attention focused on $CO_2$ regression and renewable energy sources has increased dramatically. In particular, the commercialization and application of MCFC systems fed with biogas have been revived because of the characteristics of $CO_2$ collection and fuel variety of MCFCs. Better economic results of MCFC systems fed with biogas are expected because biogas is a relatively inexpensive fuel compared to liquefied natural gas (LNG). However, the pretreatment cost is added when using anaerobic digester gas (ADG), one of the biogases, as a fuel of MCFC systems because it contains high $H_2S$ and other contaminants, which are harmful sources to the MCFC stack in ADG. Thus, an accurate economic analysis and comparison between MCFCs fed with biogas and LNG are very necessary before the installation of an MCFC system fed with biogas in a plant. In this paper, the economic analysis of an MCFC fed with ADG was carried out for various conditions of electricity and fuel price and compared with the case of an MCFC fed with LNG.