• Title/Summary/Keyword: Renewable Energy Policy

Search Result 422, Processing Time 0.025 seconds

Study on Performance Evaluation and Efficiency Comparison for Solar Collector with Thermosyphon Tube-type (태양열집열기의 성능평가 및 열사이폰관형 집열기의 효율 비교 연구)

  • Sim, Han-Sub;Yang, Young-Joon
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.175-182
    • /
    • 2014
  • The use of solar energy among renewable energy tends to increase because of infinity and cleanness of resources. Even though the consumption rate of solar energy in our country is still low, however, in recent years, the research for solar energy have been widely conducted due to policy support of government. This study was performed to make the system of performance test for solar collector and to investigate thermal efficiency for solar collector with thermosyphon tube-type. As a result, in case of indoors measurement using halogen lamp, thermal efficiency for solar collector with thermosyphon tube-type was increased about 15~22% after 120 minutes compared with that of solar collector with double evacuated tube-type. In addition, in case of outdoors measurement, thermal efficiency of thermosyphon tube-type was showed maximum about 46% higher than double evacuated tube-type.

A Study on the Review Method of Zero Energy Independence Rate in Building Applied with BIM-based BIPV (BIM기반 BIPV 적용 건축물의 제로에너지 자립률 검토 방법에 관한 연구)

  • Choi, Kyu-Hyeok;Jeon, Hyun-Woo;Park, Kyung-Do
    • Journal of Digital Convergence
    • /
    • v.20 no.2
    • /
    • pp.277-287
    • /
    • 2022
  • ZEB is a building that increases the energy independence of the building itself, and new and renewable elements that can produce energy are essential, and BIPV is the most notable technology. In ZEB's design, BIPV should be planned early in the design, but BIPV plans are insufficient in the early stages. Therefore, this study derived elements for theoretical consideration of BIM and ZEB and analysis of ZEB independence rate based on BIM, a convergence design technology, and analyzed BIPV energy production and building energy consumption. Finally, by calculating the energy independence rate and reviewing the rating criteria in the project model, a basic research method for calculating the energy independence rate of ZEB at the beginning of the design was presented. Through this, it is expected that design productivity can be improved by supporting the decision of ZEB subjects.

Economic feasibility of 1kw household PEMFC System in Korea and Japan (한국과 일본에서의 가정용 PEMFC 시스템 경제성 분석)

  • Oh, Si-Doek;Kim, Ki-Young;Seo, Seok-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.105-108
    • /
    • 2007
  • Fuel cell with high electric efficiency has many probabilities of commercial use. Especially, proton exchange membrane fuel cell (PEMFC) which is a low temperature fuel cell and has less influence on $CO_2$ concentration is considered the power generation system of small building and household. We calculated the optimal operational plans of 1 kW household PEMFC power system based on the daily electricity and heat demand patterns of Japan and Korea. Calculated results show that the economic feasibility of PEMFC power system is very sensitive to the cost policy of electricity and natural gas.

  • PDF

The Evaluation of Solar Power Promotion Policy: From the Perspective of FIT(Feed-in Tariff) (국내 태양광보급사업의 평가: 발전차액 지원제도를 기준으로)

  • Eo, Sung-Yun;Um, Shin-Young;Lee, Jin-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.401-404
    • /
    • 2009
  • 정부는 신재생에너지 보급지원을 위해 2002년도부터 발전차액지원제도를 시행해 오고 있다. 본 연구에서는 발전차액지원제도와 관련된 에너지관리공단의 내부 자료를 이용하여 119개의 태양광발전사업의 실증평가를 시행하였다. 실증분석을 위해 단위투자비당 발전량을 지수화하고 투자비 대비 효율을 산출하였다. 또한 이 분석을 위해 일사량, 설비용량, 모듈 인버터 투자비 등을 고려하였다. 분석결과 투자대비 효율 산정결과에 일사량과 단위 설비용량당 모 듈 인버터 투자비의 영향이 크게 나타난 것으로 확인되었다. 단위 투자비당 발전량을 분석한 결과 전라도의 태양광발전소의 효율은 분석 대상인 24개 지역의 평균보다는 높으나 발전소별 편차가 높게 나타난다는 점은 향후 보급사업을 평가하는 경우 추가적으로 고려되어야 할 문제라고 판단된다. 기타 자료분석 결과에 따라 효율관리를 위한 대안을 제시하였다.

  • PDF

Germany Goes Green - Innovations towards a Sustainable Regional Development

  • Gruehn, Dietwald
    • World Technopolis Review
    • /
    • v.1 no.4
    • /
    • pp.230-239
    • /
    • 2013
  • The paper deals with recent paradigm shift in German environmental policy, fundamentally modifying the German society towards a sustainable future development. Key elements of this development are forceful climate protection measures to contribute to global climate protection strategy and to fulfil international conventions, supplemented by a comprehensive strategy to promote the adaptation to climate change, the nuclear power phase out in the medium term, and innovative landscape and regional planning projects to strengthen regional identity and economic power. All this components are,complemented by a financial support program including incentives, tax reductions, and research funding.

Analyzing local perceptions toward the new nuclear research reactor in Thailand

  • Tantitaechochart, Sarasinee;Paoprasert, Naraphorn;Silva, Kampanart
    • Nuclear Engineering and Technology
    • /
    • v.52 no.12
    • /
    • pp.2958-2968
    • /
    • 2020
  • Understanding public perception on nuclear research reactor is necessary for the policy maker to adopt such technology in Thailand, especially the locals who live in the proposed location. The study compared perceptions between the locals living near the proposed nuclear research reactor location (within 5 km) and those living in the outer region (5-15 km). Structural equation modeling technique was adopted by assuming casual relationships between latent variables including social status, information perception, trust, benefit perception and risk perception on the local acceptance of research reactor. The results showed that the strongest relationships for both the inner and the outer perimeters were from information perception toward technology acceptance via trust and benefit perception. While both zones showed similar results, the outer perimeter seemed to show slightly stronger effects than those in the inner perimeter.

Study on Surface Temperature Change of PV Module Installed on Green Roof System and Non-green Roof System (옥상녹화와 비 옥상녹화 평지붕에 설치 된 PV모듈의 표면온도 변화 고찰)

  • Yoo, Dong-Chul;Lee, Eung-Jik;Lee, Doo-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.214-219
    • /
    • 2011
  • Today, various activities to save energy are being conducted around the world. Even in our country, carbon reduction policy is being conducted for low carbon green growth and with this movement, effort to replace energy sources by recognizing the problems on environment pollution and resource exhaustion due to the indiscrete usage of fossil fuel is being made. Therefore, active study on renewable energy is in progress as part of effort to replace the energy supply through fossil fuel and solar ray industry has rapidly developed receiving big strength of renewable energy policies. The conclusion of this study measuring the surface temperature change of single crystal and polycrystalline PV module in green roof system and non-green roof system aspect are as follows. There was approximately $4^{\circ}C$ difference in PV module temperature in green roof system and non-green roof system aspect and this has the characteristic to decrease 0.5% when the temperature rises by $1^{\circ}C$ when the front side of the module is $20^{\circ}C$ higher than the surrounding air temperature following the characteristic of solar cells. It can be concluded that PV efficiency will be come better when it is $4^{\circ}C$ lower. Also, in result of temperature measurement of the module back side, there was $5^{\circ}C$ difference of PV module installed on the PV module back side and green roof system side on the 5th, $3^{\circ}C$ on the 4th, $2^{\circ}C$ on the 5th to show decreasing temperature difference as the air temperature dropped, but is judged that there will be higher temperature difference due to the evapotranspiration latent heat effect of green roof system floor side as the temperature rises. Based on this data, it is intended to be used as basic reference to maximize efficiency by applying green roof system and PV system when building non-green roof system flat roof.

  • PDF

Public Preferences for Replacing Hydro-Electricity Generation with Coal-Fired Power Generation (석탄화력 발전 대비 수력 발전에 대한 국민 선호도 분석)

  • Choi, Hyo-Yeon;Ryu, Mun-Hyun;Yoo, Seung-Hoon
    • Journal of Energy Engineering
    • /
    • v.24 no.1
    • /
    • pp.164-171
    • /
    • 2015
  • Although coal-fired power generation has played a role as base load unit, it has incurred various social costs in the process of generating and providing electricity. It is necessary to extend the proportion of low-carbon power generations, and reduce the ratio of coal-fired power generation to cope with global climate changes. This study, therefore, attempts to estimate the public's willingness-to-pay (WTP) for substitution of supplied electricity from hydro-electricity generation, a representative renewable energy, for coal-fired power generation. To this end, we apply the contingent valuation (CV) method, widely used technique when valuing non-market goods, to elicit the public's WTP. In addition, a spike model is employed to consider zero WTPs. After the empirical analysis with 1,000 households CV survey data, the results show that mean household's WTP for replacing supplied electricity from hydro-electricity generation with coal-fired power generation is estimated to be about 54 KRW per kWh. The results of this study are expected to contribute to determining energy-mix and provide benefit information of hydro-electricity generation.

Study on Noise and Low Frequency Noise generated by Wind Power plant(Wind Farm) (풍력발전시설에서 발생하는 환경소음 및 저주파음에 관한 연구)

  • Park, Young-Min;Choung, Tae-Ryang;Son, Jin Hee
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.4
    • /
    • pp.425-434
    • /
    • 2011
  • The energy produced by wind power generation is a clean energy product because it is acquired by using renewable resource. Wind power plants("wind farms), in Korea, have been built and operated as 345.6MW facilities from 2001 until now 2009. Nevertheless, environmental issues regarding construction of wind power plants have arisen. accordingly it is time to consider the environmental and social issues of wind power in accordance with the government's policy objectives of increased wind power production. In this study, we investigated the influence that noise and low frequency noise caused by Wind power plants have on neighborhood and residents. We also sought solutions to these issues. In order to analyze the issues of wind power facilities, we compared and examined precedents and the solutions for noise and low frequency noise in Europe, the United states and Japan. We intended to examine the influences of wind power facilities and propose alternative in dealing with these issues.

A Study on Consumer Protections for the Introduction of Smart Grid (스마트그리드 도입에 따른 소비자 보호 연구)

  • Kim, Hyun-Jae;Jo, Sung-Han
    • Journal of Digital Convergence
    • /
    • v.9 no.5
    • /
    • pp.1-9
    • /
    • 2011
  • The smart grid can create benefits such as the expansion of consumer choice and flexibility enhancement, adaption to future electric power industry change and the increasing use of renewable energy sources. Consumers can make a contribution to improve the overall effectiveness of system through active receptive response. They can enhance the energy consumption efficiency based on more information from service providers. The Smart Grid Promotion Act, which was enacted in April 2011, contains consumer protection provisions such as information collecting, sharing, and protection measures. On this reason, it is needed to expand promotion and education regarding the smart grid to improve the consumer awareness, and the schemes to enhance smart grid consumer acceptance should be established.