• Title/Summary/Keyword: Removal technique

Search Result 962, Processing Time 0.025 seconds

EFFECT OF TAPER AND SURFACE AREA OF INNER CROWN ON THE RETENTIVE FORCE OF ELECTROFORMED OUTER CROWN (전기성형술로 제작된 외관의 유지력에 내관의 축면경사도와 표면적이 미치는 영향)

  • Kang Wan-Keun;Lim Jang-Seop;Jeon Young-Chan;Jeong Chang-Mo;Jeong Hee-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.2
    • /
    • pp.165-173
    • /
    • 2006
  • Purpose: With gold electroforming system fir the double crown, the secondary crown is electroformed directly onto the primary crown. An even thick layer of high precision can be acquired. It is thought that the retention of electroformed outer crown is primarily acquired by the adhesive force (surface tension) through the saliva which is interposed between precisely fitted inner and outer crown. The purpose of this study was to investigate the effect of taper and surface area of inner crown on the retentive force of electroformed outer crown according to the presence of saliva. Materials and methods: 32 titanium inner crowns with cervical diameter of 8 mm and cone angles of 0, 2, 4, 6 degrees, which had same surface area by regulated height, were machined on a lathe. Another 32 titanium inner crowns with cone angles of 0, 2, 4, 6 degrees, which had doubled surface area by increased cervical diameter. were fabricated. Eight specimens of each group, for a total of 64 titanium inner crowns, were prepared. The electroformed outer crowns were fabricated directly on the inner crowns by using electroforming machine(GAMMAT free, Gramm Technik, Germany). The tertiary frameworks were waxed-up on the electroformed outer crown and cast using nonprecious alloy($Rexillium^(R)III,\;Jeneric^(R)/Pentronh^(R)$ Inc., USA). The cast metal frameworks were sandblasted with alubimium oxides and cemented using resin cement(Superbond C&B, Sun Medical Co., Japan) over the electroformed copings of each specimen. Then, artificial saliva($Taliva^(R)$, Halim Pharm. Co., Korea) was sprayed between the inner and outer crown, and they were connected under 5 kg force. The retentive force was measured by the universal testing machine(Tinius Olsen 1000, Tinius Olsen, USA) with a cross-head speed of 66.67 mm/sec. The direction of cross-head travel was exactly aligned with the path of removal of the respective specimens. This measurement procedures for retentive force of electroformed outer crown with artificial saliva were repeated in the same way without presence of artificial saliva. Results and Conclusion: The following conclusions were drawn: 1. The retentive force of electroformed outer crown was decreased according to increased taper of inner crown(P<.05). 2. The retentive force of electroformed outer crown showed no significant differences according to surface area and the presence of artificial saliva(P>.05).

TREATMENT OF IMPACTED MAXILLARY CENTRAL INCISORS USING ORTHODONTIC TRACTIONS (매복된 상악 중절치의 교정적 처치를 통한 치험례)

  • Kim, Nam-Hyuk;Kim, Seong-Oh;Song, Je-Seon;Son, Heung-Kyu;Choi, Byung-Jai;Lee, Jae-Ho;Choi, Hyung-Jun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.1
    • /
    • pp.109-116
    • /
    • 2010
  • Impaction is defined as a cessation of the eruption of a tooth caused by a clinically or radiographically detectable physical barrier in the eruption path or by an ectopic position of the tooth. The reasons for impaction of the maxillary central incisor are supernumerary tooth, odontoma, ectopic position of tooth germ, dilacerated tooth and so force. Impacted tooth cause space loss due to proximal movement of adjacent tooth, malocclusion, root resorption of adjacent tooth, cyst formation, so careful observation and early detection is important and exact treatment should be applied to prevent these results. The treatment options of impacted tooth include induction an eruption through extraction of deciduous tooth or surgical exposure, reposition of impacted tooth by surgical method or orthodontic treatment. Orthodontic traction is recommended when an eruption does not happen after removal of barrier or surgical exposure, when eruption path is too transpositioned to be corrected spontaneously so eruption does not expected. In these cases, traction of impacted maxillary central incisor was carried out using orthodontic method with closed eruption technique and it showed good clinical results so we report these cases.

Quantitative Evaluation of the Remaining Hepatic Function after Surgery in Patients with Hepatic Cancer using Deconvolution Technique of Tc-99m DISIDA SCAN (Tc-99m DISIDA SCAN에서 deconvolution 방법을 이용한 간암 환자의 수술 후 잔여 간 기능의 정량적 평가)

  • Kim, Deok-Won;Kim, Su-Chan;Yun, Seok-Jin;Lee, Jong-Du;Kim, Byeong-Ro
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.301-306
    • /
    • 1997
  • Surgical removal of hepatic cancerous tissues have been widely performed due to its early detection. However, a patient can not survive if excessive hepatic tissues were removed. Therefore, quantitative evaluation of remaining hepatic function after surgery is a really important factor for surgeon. the currently used ICG Rmax and Lidocaine clearance tests have disadvantages such as tedium, complexity, and inability to estimate remaining hepatic function after surgery. While HEF has advantages such as simplicity, quickness, nonivasiveness, and quantification, its reliability has been doubtful. Thus, the program for calculation of HEF has been developed from serial gamma camera image data. And we compared the reliability of HEF with ICG Rmax and Lidocaine clearance test using 6normal and 18 abnormal rabbits with damaged livers. The correlation coefficient of HEF to ICG Rmax and MEGX was 0.91, 0.94, respectively. I was also found that the HEFs of normal and abnormal hepatic tissues was higher than 100% and lower than 80%, respectively. Thus we confirmed that HEF can be a good indicator distinguishing between abnormal tissues and normal ones. Finally, we could conclude that patients would survive if both the pre-and the post-operative HEF were greater than 60%.

  • PDF

GNSS Software Receivers: Sampling and jitter considerations for multiple signals

  • Amin, Bilal;Dempster, Andrew G.
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.385-390
    • /
    • 2006
  • This paper examines the sampling and jitter specifications and considerations for Global Navigation Satellite Systems (GNSS) software receivers. Software radio (SWR) technologies are being used in the implementation of communication receivers in general and GNSS receivers in particular. With the advent of new GPS signals, and a range of new Galileo and GLONASS signals soon becoming available, GNSS is an application where SWR and software-defined radio (SDR) are likely to have an impact. The sampling process is critical for SWR receivers, where it occurs as close to the antenna as possible. One way to achieve this is by BandPass Sampling (BPS), which is an undersampling technique that exploits aliasing to perform downconversion. BPS enables removal of the IF stage in the radio receiver. The sampling frequency is a very important factor since it influences both receiver performance and implementation efficiency. However, the design of BPS can result in degradation of Signal-to-Noise Ratio (SNR) due to the out-of-band noise being aliased. Important to the specification of both the ADC and its clocking Phase- Locked Loop (PLL) is jitter. Contributing to the system jitter are the aperture jitter of the sample-and-hold switch at the input of ADC and the sampling-clock jitter. Aperture jitter effects have usually been modeled as additive noise, based on a sinusoidal input signal, and limits the achievable Signal-to-Noise Ratio (SNR). Jitter in the sampled signal has several sources: phase noise in the Voltage-Controlled Oscillator (VCO) within the sampling PLL, jitter introduced by variations in the period of the frequency divider used in the sampling PLL and cross-talk from the lock line running parallel to signal lines. Jitter in the sampling process directly acts to degrade the noise floor and selectivity of receiver. Choosing an appropriate VCO for a SWR system is not as simple as finding one with right oscillator frequency. Similarly, it is important to specify the right jitter performance for the ADC. In this paper, the allowable sampling frequencies are calculated and analyzed for the multiple frequency BPS software radio GNSS receivers. The SNR degradation due to jitter in a BPSK system is calculated and required jitter standard deviation allowable for each GNSS band of interest is evaluated. Furthermore, in this paper we have investigated the sources of jitter and a basic jitter budget is calculated that could assist in the design of multiple frequency SWR GNSS receivers. We examine different ADCs and PLLs available in the market and compare known performance with the calculated budget. The results obtained are therefore directly applicable to SWR GNSS receiver design.

  • PDF

EVALUATION OF ENTEROCOCCUS FAECALIS REMOVAL EFFICACY OF THE ENDOVAC® AND ENDOACTIVATOR® INTRACANAL IRRIGATION METHODS (EndoVac®과 EndoActivator®를 이용한 근관세척법의 Enterococcus faecalis 제거 효율 평가)

  • Song, Seung-Gon;Park, Se-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.5
    • /
    • pp.390-396
    • /
    • 2009
  • The aim of this study was to evaluate endodontic irrigation methods with $EndoVac^{(R)}$ and $EndoActivator^{(R)}$ in the elimination of Enterococcus faecalis from the root canals. Extracted 70 human single-rooted teeth were used. The canals were instrumented by a crown-down technique with .04 taper ProFile to ISO size 40. After the teeth were autoclaved, the canals were inoculated with E. faecalis and incubated for 48 h. The teeth were randomly divided into three experimental groups of 20 teeth each according to canal irrigation methods and two control groups as follows: group 1 - $EndoVac^{(R)}$; group 2 - $EndoActivator^{(R)}$; group 3-Conventional needle irrigation method. After canal irrigation using 2.5% NaOCl. first samples (S1) were taken using sterile paper point. And the canals were filled with sterile brain heart infusion (BHI) broth and incubated for 24 h, then second samples (S2) were taken. The samples were cultured on BHI agar plate to determine the numbers of colony forming units (CFU). In first sampling (S1), only one canal of conventional method among the all experimental groups was positive cultured. In second sampling (S2), $EndoVac^{(R)}$ group showed the least positive culture numbers of E. faecalis. There was statistically significant difference between the $EndoVac^{(R)}$ and conventional needle irrigation methods in the mean value of Log CFU. According to the results of this study, $EndoVac^{(R)}$ showed better efficacy than conventional needle irrigation method in the elimination of E. faecalis from the root canal.

Comparison of $LigaSure^{TM}$ and Bipolar Vessel Sealing System for Laparoscopic Ovariectomy in Cats (복강경을 이용한 고양이의 난소 절제술에서 지혈기구인 $LigaSure^{TM}$와 양극 전기 응고 장치(bipolar)의 비교)

  • Jin, So-Young;Lee, Seung-Yong;Park, Se-Jin;Kim, Young-Ki;Seok, Seong-Hoon;Hwang, Jae-Min;Yeon, Seong-Chan
    • Journal of Veterinary Clinics
    • /
    • v.31 no.6
    • /
    • pp.477-482
    • /
    • 2014
  • The aim of this study was to investigate and compare technique, surgical time, and complications of laparoscopic ovariectomy using $LigaSure^{TM}$ and bipolar vessel sealing system in cats. Laparoscopic ovariectomy was performed under general anesthesia on 10 healthy female cats admitted for elective ovariectomy. Surgery was performed through three midline portals. Each ovary was randomly-assigned to removal by use of either $LigaSure^{TM}$ or bipolar vessel sealing system. Duration of predetermined surgery intervals and complications were compared. Bipolar OVE ($2:16{\pm}1:14$ minutes) took significantly longer surgical time compared to the $LigaSure^{TM}$ OVE ($1:24{\pm}0:59$ minutes, P = 0.021). The ovarian pedicle fat and obesity did not influence surgery duration. Intraoperative hemorrhage occurred with bipolar OVE in three cats, but had no significant influence on surgical time. The results suggest that both $LigaSure^{TM}$ and bipolar devices appear to be effective, but $LigaSure^{TM}$ can be used as a stand-alone device that decreases surgical time and complication compared with bipolar vessel sealing system.

Efficient 3D Object Simplification Algorithm Using 2D Planar Sampling and Wavelet Transform (2D 평면 표본화와 웨이브릿 변환을 이용한 효율적인 3차원 객체 간소화 알고리즘)

  • 장명호;이행석;한규필;박양우
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.31 no.5_6
    • /
    • pp.297-304
    • /
    • 2004
  • In this paper, a mesh simplification algorithm based on wavelet transform and 2D planar sampling is proposed for efficient handling of 3D objects in computer applications. Since 3D vertices are directly transformed with wavelets in conventional mesh compression and simplification algorithms, it is difficult to solve tiling optimization problems which reconnect vertices into faces in the synthesis stage highly demanding vertex connectivities. However, a 3D mesh is sampled onto 2D planes and 2D polygons on the planes are independently simplified in the proposed algorithm. Accordingly, the transform of 2D polygons is very tractable and their connection information Is replaced with a sequence of vertices. The vertex sequence of the 2D polygons on each plane is analyzed with wavelets and the transformed data are simplified by removing small wavelet coefficients which are not dominant in the subjective quality of its shape. Therefore, the proposed algorithm is able to change the mesh level-of-detail simply by controlling the distance of 2D sampling planes and the selective removal of wavelet coefficients. Experimental results show that the proposed algorithm is a simple and efficient simplification technique with less external distortion.

SEM EVALUATION OF THE PREPARED ROOT CANALS BY HAND AND Ni-Ti ROTARY ROOT CANAL INSTRUMENTS (Hand & rotary root canal instrument의 근관내 삭제 형태에 관한 전자현미경적 비교)

  • Oh, Tae-Seok;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.477-486
    • /
    • 1998
  • Recently the development of rotary instrument makes it possible that in root canal treatment operator saves much more time, maintans original curved canal shape and easily prepares continuous tapered root canal. The purpose of this experiment was to examine the smoothness of the internal surface of prepared root canal and the effectiveness of debridement in prepared root canal by SEM for the comparison of hand and Ni-Ti rotary instrument. 25 extracted human teeth were access opened and # 10 K-type file was introduced into canal until it was appeared at the apical foramen. The working length was established by subtracting 0.5mm from this measurement. Group 1. The root canal preparation was done to # 30 with working length and then step-back until # 45 with K-Flexofile (Maillefer, Swiss). Group 2. Root canal preparation was done by Naviflex Ni-Ti file (Brasseler, USA) as the same technique with group 1. Group 3. Canal was prepared by Profile .04 (Maillefer, Swiss) taper until #30. Group 4. With use of Quantec (Tycom, USA) root canal was prepared from file number 1 to 8. In group 1 and 2, the root canal irrigant was NaOCl and the other groups, NaOCl and RC-prep (Premine Dental Products, USA) was used. The prepared teeth were notched with high-speed bur as bucco-lingual direction and fractured with chisel and mallet, then examined with SEM. Group 1 showed smooth internal surface. There were scratches mainly to the axial direction. Group 2 showed similar characteristics to those in group 1. Group 3 showed more smoother and linear cutting surface with bised scratches. Group 4 has the almost same characteristics group 3 and there was no difference in the file design. Ni-Ti rotary root canal instrument prepare the dentinal wall more smoother than hand instrument. The effectiveness of debridement was not fully affected by file design. The isthmus area and accessory canals of the root canal system were not prepared in any group. According to the result, hand and rotary type instrumentation techniques were effective in removal of major amount of tissue from root canal but it was not complete. In the direction of cutting movement there was difference between them.

  • PDF

Numerical Analysis on Effect of Stemming Condition in Mine Ventilation Shaft Blasting (광산 통기수갱발파에서 전색조건이 발파효율에 미치는 영향에 관한 수치해석적 연구)

  • Kim, Jun-ha;Kim, Jung-gyu;Jung, Seung-won;Ko, Young-hun;Baluch, Khaqan;Kim, Jong-gwan
    • Explosives and Blasting
    • /
    • v.39 no.3
    • /
    • pp.15-23
    • /
    • 2021
  • Ventilation shafts are pathways in mines and tunnels for the removal of dust or smoke during underground space construction and operation. In mines, blasting with long blast holes is preferred for the excavation of a ventilation shaft in the 10~20m long crown pillar section. In this case, the bottom part of the blast hole is completely drilled in order to determine the drilling error, and this causes a problem of lowering the explosive charge and blasting efficiency. It is possible to solve the problem of explosive loading and to increase the blast efficiency by covering the curb of the blasthole by using stemming material. In this study, simulations for the blasting of a ventilation shaft were performed with various stemming lengths and the blasthole diameters(45, 76mm) using AUTODYN 2D SPH(Smooth particle hydrodynamics) analysis technique. Also the optimal bottom stemming column was derived by checking the size of the boulder and burden line according to blasting. Analysis result, blasting efficiency is lessened in case of stemming length less than 30cm and the optimal length of the stemming material should be 30cm or higher to achieve high efficiency of blasting.

Selection of rs2rs2titi Soybean Genotype with Yellow Seed Coat (rs2rs2titi 유전자형을 가진 노란 콩 계통 선발)

  • Choi, Sang Woo;Park, Jun Hyun;Chung, Jong Il
    • Journal of Life Science
    • /
    • v.28 no.11
    • /
    • pp.1285-1289
    • /
    • 2018
  • Soybean [Glycine max (L.) Merr.] seed is an important dietary source of protein, oil, carbohydrates, isoflavones, and other nutrients for humans and animals. But, antinutritional factors in the raw mature soybean are exist. Kunitz trypsin inhibitor (KTI) protein and stachyose are main antinutritional factors in soybean seed. The genetic removal of the antinutritional factors will improve the nutritional value of soybean seed. The objective of this research was to breed a new yellow soybean strains (rs2rs2titi genotype) with the traits of lacking of KTI protein and low content of stachyose. Breeding population was developed from the cross of "Jinyangkong" and 15G1 parents. Presence or absence of KTI protein was detected based on Western Blot technique. Content of stachyose in mature seed was detected by HPLC. Total four new strains (603-1, 603-2, 625, and 694) with KTI protein free and low content of stachyose were selected. Four strains (603-1, 603-2, 625, and 694) have yellow seed coat and hilum. Plant height of 603-1 strain was 65 cm and 100-seed weight was 29.2 g. Plant height of 603-2 strain was 66 cm and 100-seed weight was 26.2 g. Plant height of 625 strain was 64 cm and 100-seed weight was 27.1 g. Content of stachyose for four new strains was 3.0~3.50 g/kg. Four strains selected in this research will be used to improve new yellow soybean cultivar with KTI protein free, and low content of stachyose.