• 제목/요약/키워드: Removal technique

검색결과 962건 처리시간 0.031초

Use of elevator instruments when luxating and extracting teeth in dentistry: clinical techniques

  • Mamoun, John
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제43권3호
    • /
    • pp.204-211
    • /
    • 2017
  • In dentistry, elevator instruments are used to luxate teeth, and this technique imparts forces to tooth particles that sever the periodontal ligament around tooth roots inside the socket and expand alveolar bone around tooth particles. These effects can result in extraction of the tooth particles or facilitate systematic forceps extraction of the tooth particles. This article presents basic oral surgery techniques for applying elevators to luxate teeth. Determination of the optimal luxation technique requires understanding of the functions of the straight elevator and the Cryer elevator, the concept of purchase points, how the design elements of elevator working ends and tips influence the functionality of an elevator, application of forces to tooth particles, sectioning teeth at furcations, and bone removal to facilitate luxation. The effectiveness of tooth particle luxation is influenced by elevator tip shape and size, the magnitude and the vectors of forces applied to the tooth particle by the tip, and sectioning and bone removal within the operating field. Controlled extraction procedures are facilitated by a dental operating microscope or the magnification of binocular surgical loupes telescopes, combined with co-axial illumination.

Removal of Volatile Organic Compounds by Photo-Catalytic Oxidation

  • Lee, Byeong-Kyu;Jung, Kwang-Ryun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제16권E호
    • /
    • pp.39-46
    • /
    • 2000
  • Volatile Organic Compounds (VOCs) are considered as the precursors of atmospheric ozone and photochemical smog formation. In particular, chemical plants have produced a lot of VOCs and thus they have been forced to reduce or remove air emissions from the on-site chemical facilities. For the effective removal of VOCs produced in the chemical plants, the authors employed a titanium oxide(TiO$_2$) mediated photo-catalytic oxidation method. The initiation methods employed in this study to produce oxygen radicals for th photo-catalytic oxidation of the VOCs were Ultra-Violet(UV), Non-Thermal Plasma(NTS), and a combination of Uv and NTP. This study focused on a comparison of the removal efficiencies of VOCs as a function of the initiation method such as NTP and/or UV techniques. Removal efficiency change of VOCs as was investigated as a function of the wavelength of the UV lamp(254, 302, and 365 nm) and the degree of TiO$_2$ coating (10 and 30%). In this study, it was identified that removal efficiencies if the VOCs under the normal air environment were much better than those under the nitrogen gas environment containing small amount of oxygen. Removal efficiency by NTP technique was much better than the UV or the combination of UV and NTP techniques. In a comparison if UV wavelengths employed, it was found that shorter wavelength showed better removal efficiency, compared with longer ones. When the removal efficiencies of VOCs were compared in terms of the degree of TiO$_2$ coating, the higher TiO$_2$coating showed better removal efficiency that the lower TiO$_2$ coating

  • PDF

증기발생기 수실 노즐댐 설치 및 제거작업의 피폭선량 저감에 영향을 주는 관리요인에 관한 연구 (Managerial Factors Influencing Dose Reduction of the Nozzle Dam Installation and Removal Tasks Inside a Steam Generator Water Chamber)

  • 이동하
    • 대한인간공학회지
    • /
    • 제36권5호
    • /
    • pp.559-568
    • /
    • 2017
  • Objective: The aim of this study is to investigate the effective managerial factors influencing dose reduction of the nozzle dam installation and removal tasks ranking within top 3 in viewpoint of average collective dose of nuclear power plant maintenance job. Background: International Commission on Radiation Protection (ICRP) recommended to reduce unnecessary dose and to minimize the necessary dose on the participants of maintenance job in radiation fields. Method: Seven sessions of nozzle dam installation and removal task logs yielded a multiple regression model with collective dose as a dependent variable and work time, number of participants, space doses before and after shield as independent variables. From the sessions in which a significant reduction in collective dose occurred, the effective managerial factors were elicited. Results: Work time was the most important factor contributing to collective dose reduction of nozzle dam installation and removal task. Introduction of new technology in nozzle dam design or maintenance job is the most important factor for work time reduction. Conclusion: With extended task logs and big data processing technique, the more accurate prediction model illustrating the relationship between collective dose reduction and effective managerial factors would be developed. Application: The effective managerial factors will be useful to reduce collective dose of decommissioning tasks as well as regular preventive maintenance tasks for a nuclear power plant.

우엉발효추출물을 이용한 생활악취물질 제거효율 조사 (Removal Efficiency of odor substance Using Arctium Lappa Root extract)

  • 이동섭;박진식
    • 한국환경과학회지
    • /
    • 제23권11호
    • /
    • pp.1953-1961
    • /
    • 2014
  • Increasing public concerns over odors and air regulations necessitates the remediation of a wide range of odor substances for industrial and indoor purpose. Currently, the wet scrubbing technique by neutralization using oils is being used to treat odor substances such as Ammonia($NH_3$), Methyl Mercaptan($CH_3SH$), Hydrogen Sulfide($H_2S$), Methylamine($CH_3NH_2$), Acetaldehyde($CH_3CHO$). The chemical analysis is performed to analyze the composition of an Arctium Lappa Root extract by VOC analyzer(Phocheck 5000Ex, ION SCIENCE co.) The objectives of the this study are to clarify the possibility of the neutralization of odors sprayed in the fixed bed and determine the removal efficiencies for different input odor concentrations. It is found that Ammonia($NH_3$), Methyl Mercaptan($CH_3SH$), Hydrogen Sulfide($H_2S$), Methylamine($CH_3NH_2$), Acetaldehyde($CH_3CHO$) are significantly removed and their removal efficiencies are higher than 98%. The kitchen detergent with Arctium Lappa Root extract showed excellent removal efficiencies of odor substances and high possibility for the development of kitchen detergent with odor removal.

Ammonia Nitrogen Removal and Recovery from Swine Wastewater by Microwave Radiation

  • La, Joohee;Kim, Taeyoung;Jang, Jae Kyung;Chang, In Seop
    • Environmental Engineering Research
    • /
    • 제19권4호
    • /
    • pp.381-385
    • /
    • 2014
  • Microwave (MW) radiation was developed to remove and recover ammonia nitrogen in the real swine wastewater. The effect of operating parameters of MW radiation such as initial pH, power, radiation time, aeration, and stirring for removal ammonia nitrogen in swine wastewater was determined. The pH, radiation time, and power were significantly influenced on the removal of ammonia nitrogen, and aeration and stirring showed relatively minor effect on the removal of ammonia nitrogen. Optimum condition was achieved to retrieve the nitrogen efficiently at pH 11, 700 W for 5 min in MW radiation process. Through this process, 83.1% of ammonia nitrogen concentration was reduced in swine wastewater and also 82.6% of ammonia nitrogen was recovered as ammonium sulfate at the optimized condition. The high ammonia removal and recovery efficiency of the MW radiation method indicated that MW radiation was an effective technique to remove and recover ammonia nitrogen in the swine wastewater.

신장 아크 반응기를 이용한 CF4 처리특성 (CF4 Treatment Characteristics using an Elongated Arc Reactor)

  • 김관태;이대훈;이재옥;차민석;송영훈
    • 한국대기환경학회지
    • /
    • 제26권1호
    • /
    • pp.85-93
    • /
    • 2010
  • $CF_4$ removal characteristics were investigated using an elongated arc reactor. The advantage of the elongated arc reactor includes direct use of treated gas as plasma operating gas and the enhancement of the removal reaction by using a thermo-chemistry and a plasma induced chemistry at the same time. Geometrical configurations, such as the length of the reactor and the shape of a throat, were tested to get an optimized removal efficiency with low power consumption. As results, over 95% of $CF_4$ removal was obtained with 300 lpm of total flowrate for various $CF_4$ concentration (0.1~1%). Corresponding specific energy density (SED), which means required electrical energy to treat the unit volume of treated gas, is about 3.5 kJ/L, The present technique can be applied to real applications by satisfying three major concerns, those are the high flowrate of treated gas, high removal efficiency (> 95%), and low power consumption (< 10 kJ/L).

맵 기반의 부분시간 공통 중간주파수 제거방식을 이용한 GNSS 신호의 상관 기법 (A GNSS Signal Correlation Using Map-based Partial-time Common Intermediate Frequency Removal Method)

  • 임성혁;지규인
    • 제어로봇시스템학회논문지
    • /
    • 제14권7호
    • /
    • pp.695-701
    • /
    • 2008
  • In this paper, we propose the efficient Doppler removal method using map-based partial-time common intermediate frequency removal technique. In the proposed algorithm, the 2-stage carrier removal process was used. First, the component of common intermediate frequency is removed. Next the component of Doppler was removed with averaging and approximation. For the evaluation of the proposed algorithm, The real-time software GPS L1 C/A-code receiver was implemented. When the proposed algorithms are used, 12 tracking channels with 3 track arm(early, prompt, late) is operated real-time on PC using a Intel Pentium-III 1.0GHz CPU. Also, the requirement of memory was less than 2Mbytes. The real-time software GNSS receiver using the proposed algorithms provides the navigation solution with below 10 meter rms error. Especially, in spited of using the various approximations for implementing the algorithms, the high sensitivity capability (able to track the weak signal with -159dBm) was achieved.

Efficiency of Aluminum and Iron Electrodes for the Removal of Heavy Metals [(Ni (II), Pb (II), Cd (II)] by Electrocoagulation Method

  • Khosa, Muhammad Kaleem;Jamal, Muhammad Asghar;Hussain, Amira;Muneer, Majid;Zia, Khalid Mahmood;Hafeez, Samia
    • 대한화학회지
    • /
    • 제57권3호
    • /
    • pp.316-321
    • /
    • 2013
  • Electrocoagulation (EC) technique is applied for the treatment of wastewater containing heavy metals ions such as nickle (Ni), lead (Pb) and cadmium (Cd) by using sacrificial anodes corrode to release active coagulant flocs usually aluminium or iron cations into the solution. During electrolytic reactions hydrogen gas evolve at the cathode. All the experiments were carried out in Batch mode. The tank was filled with synthetic wastewater containing heavy metals and efficiency of electro-coagulation in combination with aluminum and iron electrodes were investigated for removal of such metals. Several parameters, such as contact time, pH, electro-coagulant concentration, and current density were optimized to achieve maximum removal efficiency (%). The concentrations of heavy metals were determined by using Atomic Absorption Spectroscopy (AAS). It is found that the electro-coagulation process has potential to be utilized for the cost-effective removal of heavy metals from wastewater specially using iron electrodes in terms of high removal efficiencies and operating cost.

Performance of GACC and GACP to treat institutional wastewater: A sustainable technique

  • Khaleel, Mohammed R.;Ahsan, Amimul;Imteaz, M.;El-Sergany, M.M.;Nik Daud, N.N.;Mohamed, T.A.;Ibrahim, Buthainah A.
    • Membrane and Water Treatment
    • /
    • 제6권4호
    • /
    • pp.339-349
    • /
    • 2015
  • Experiments were carried out using granular activated carbon (GAC) adsorption techniques to treat wastewater contaminated with organic compounds caused by diverse human activities. Two techniques were assessed: adsorbent GAC prepared from coconut shell (GACC) and adsorbent GAC from palm shell (GACP). A comparison of these two techniques was undertaken to identify ways to improve the efficiency of the treatment process. Analysis of the processed wastewater showed that with GACC the removal efficiency of biochemical oxygen demand (BOD), chemical oxygen demand (COD), turbidity, total suspended solids (TSS) and total dissolved solids (TDS) was 65, 60, 82, 82 and 8.7%, respectively, while in the case of GACP, the removal efficiency was 55, 60, 81, 91 and 22%, respectively. It can therefore be concluded that GACC is more effective than GACP for BOD removal, while GACP is better than GACC for TSS and TDS removal. It was also found that for COD and turbidity almost the same results were achieved by the two techniques. In addition, it was observed that both GACC and GACP reduced pH value to 7.9 after 24 hrs. Moreover, the optimal time period for removal of BOD and TDS was 1 hr and 3 hrs, respectively, for both techniques.