• Title/Summary/Keyword: Removal ratio

Search Result 1,610, Processing Time 0.021 seconds

Effect of Rapid Mixing Intensity and Coagulant Dosages on Phosphorus Removal by Coagulation (응집을 이용한 인의 제거에 급속혼화강도 및 응집제 주입량이 미치는 영향)

  • Han, Hyun-Jin;Moon, Byung-Hyun
    • Clean Technology
    • /
    • v.18 no.4
    • /
    • pp.404-409
    • /
    • 2012
  • In this study, the effects of mixing intensity and coagulant dosages on the characteristics of floc growth for phosphorus removal were investigated. The experiments were conducted under Al/P molar ratio of 1.0, 1.5 and 2.0; rapid mixing intensity with G value of 100, 300, and 500 $s^{-1}$. The characteristics of floc growth were measured by flocculation index (FSI) and the removal efficiencies of phosphorus by using different size filters. The removal efficiencies of soluble phosphorus increased as Al/P molar ratio and rapid mixing intensity increased. However, the highest removal efficiencies of T-P were observed at G value of 300 $s^{-1}$. When Al/P molar ratio was lower than 1.0, the value of FSI at G value of 500 $s^{-1}$ was the largest. However, when Al/P ratio was larger than 1.0, the value of FSI at G value 300 $s^{-1}$ was the largest. Effects of mixing intensity and Al/P molar ratio on coagulation for phosphorus removal of synthetic and real wastewater effluent were observed to be similar.

Sharpness-aware Evaluation Methodology for Haze-removal Processing in Automotive Systems

  • Hwang, Seokha;Lee, Youngjoo
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.5 no.6
    • /
    • pp.390-394
    • /
    • 2016
  • This paper presents a new comparison method for haze-removal algorithms in next-generation automotive systems. Compared to previous peak signal-to-noise ratio-based comparisons, which measure similarity, the proposed modulation transfer function-based method checks sharpness to select a more suitable haze-removal algorithm for lane detection. Among the practical filtering schemes used for a haze-removal algorithm, experimental results show that Gaussian filtering effectively preserves the sharpness of road images, enhancing lane detection accuracy.

Removing High Concentration Organic Matters by Using Electrolysis (전기분해에 의한 고농도 유기물질 제거 특성)

  • Gil, Dae-Soo;Lee, Byung-Hun;Lee, Jea-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.2
    • /
    • pp.251-264
    • /
    • 2000
  • Organic removal from synthetic wastewater by electrochemical methods was investigated with various operating parameters, such as current density, retention time, electrode gap and $Cl^-/COD_{Cr}$ ratio. In electrolysis, dioxide iridium coated titanium ($IrO_2/Ti$) and stainless steel plate were used for anode and cathode respectively. The $COD_{Cr}$ removal efficiencies between plate type anode and net type anode were about same effect, but electrolytic power using net type anode is low than plate type anode. The $Cl^-/COD_{Cr}$ ratio was about $1.3kgCl^-/kgCOD_{Cr}$ when organic removal obtained 70 %, $Cl^-/COD_{Cr}$ ratio needs $2.2kgCl^-/kgCOD_{Cr}$ so as to organic completely remove. The removal efficiency of organics increased with current density, retention time and $Cl^-/COD_{Cr}$ ratio, but decreased with increasing electrode gap. The relationship of operating conditions and $COD_{Cr}$ removal efficiencies are as follows. $$COD_{Cr}(%)=80.0360(Current\;density)^{0.4451}{\times}(HRT)^{0.8102}{\times}(Gap)^{-0.4915}{\times}(Cl^-/COD_{Cr})^{0.5805}$$ There existed a competition between the removals for $COD_{Cr}$ and ammonium during electrolysis, the removal of ammonium was shown to be dominant and $COD_{Cr}$ removal was low. But $COD_{Cr}$ removal was raised as addition of alkalinity.

  • PDF

COD and BOD Removal of Artificial Municipal Wastewater by a Column filled with Zeolite (제올라이트 칼럼에 의한 인공생활하수의 COD 및 BOD 제거에 관한 연구)

  • Seo, Jeoung-Yoon
    • Journal of Wetlands Research
    • /
    • v.3 no.1
    • /
    • pp.75-89
    • /
    • 2001
  • Constructed wetlands were typically cost less to build and operate, and require less energy than standard mechanical treatment technology but they have similar performance to centralized wastewater treatment plants. Therefore, they were constructed especially many in rural areas, where are small villages but not industries. Accordingly, plantless column tests were performed to investigate the possibility on using zeolite as a filter medium of constructed wetland for the wastewater treatment. $COD_{cr}$ removal efficiency was 94.63% at hydraulic load $314L/m^2{\cdot}d$ and filtering hight 100cm filled with a zeolite mixture. This zeolite mixture consisted of 1 : 1 by volume of a zeolite in the diameter range of 0.5 to 1mm to a zeolite in the diameter range of 1 to 3mm. According, hydraulic load $314L/m^2{\cdot}d$ was considered as optimal. Three zeolite mixture were used to determine the optimal mixing ratio by volume of a zeolite(A) in the diameter range of 0.5 to 1mm to a zeolite(B) in the diameter range of 1 to 3mm diameter. 1 : 3, 1 : 1 and only B in A to B by volume were tested at hydraulic load $314L/m^2{\cdot}d$ and filtering hight 100cm. $COD_{cr}$ removal efficiency was more than 89% at mixing ratios of 1 : 3 and 1 : 1 in A to B. Removal efficiency was lower at the column filled with only B. Removal efficiency was better at filter medium filled with mixing ratio 1 : 1 in A to B than with the other mixing ratios. Thus, it was found that the mixture of mixing ratio 1 : 1 in A to B was appropriate for filter medium of constructed wetland. Removal efficiency was higher in down-flow than in up-flow, and $COD_{cr}$ and BOD were removed best in 20cm filter height near feeding area.

  • PDF

Piggery Waste Treatment using Partial Nitritation and Anaerobic Ammonium Oxidation (부분질산화와 혐기성 암모늄산화를 이용한 돈사폐수처리)

  • Hwang, In-Su;Min, Kyung-Sok;Lee, Young-Ok
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.4
    • /
    • pp.599-604
    • /
    • 2006
  • Nitrogen removal with the combined SHARON (Single reactor system for high ammonium removal over nitrite)ANAMMOX (Anaerobic ammonium oxidation) process using the effluent of ADEPT (Anaerobic digestion elutriated phased treatment) slurry reactor with very low C/N ratio for piggery waste treatment was investigated. For the preceding SHARON reactor, ammonium nitrogen loading and removal rate were $0.97kg\;NH_4-N/m^3_{reactor}/day$ and $0.68kg\;NH_4-N/m^3_{reactor}/day$ respectively. In steady state, bicarbonate alkalinity consumption for ammonium nitrogen converted to $NO_2-N$ or $NO_3-N$ was 8.4 gram per gram ammonium nitrogen. The successive ANAMMOX reactor was fed with the effluent from SHARON reactor. The loading and removal rate of the soluble nitrogen defined as the sum total of $NH_4-N$, $NO_2-N$ and $NO_3-N$ in ANAMMOX reactor were $1.36kg\;soluble\;N/m^3_{reactor}/day$ and $0.7kg\;soluble\;N/m^3_{reactor}/day$, respectively. The average $NO_2-N/NH_4-N$ removal ratio by ANAMMOX was 2.41. Fluorescence in situ hybridization (FISH) analysis verified that Candidatus Kuenenia stuttgartiensis were dominate, which means that they played an important role of nitrogen removal in ANAMMOX reactor.

Coagulation Treatment of Landfill Leachate Using Acid Mine Drainage(AMD) (산성폐광폐수를 이용한 매립지 침출수의 응집처리)

  • 최봉종;이승목;이상호
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.4
    • /
    • pp.129-133
    • /
    • 2000
  • The objective of this study was to invetigate the coagulation effects of landfill leachate by using Acid Mine Drainage(AND). The coagulation efficiency was investigated by mixing landfill leachate with F $e^{+3}$ solution earned by oxidation of pyrite(AMD). In the results of this experiment, it was found that the amount of removed COD and SS was approximately 30% respectively by mixing at the ratio of AMD three to leachate one. And it showed highest turbidity removal efficiency at all mixing ratio. Concentration of Fe was decreased with increasing mixing ratio, however it was increased inversely at mixing ratio 4. Optimal mixing ratio was 3 at the results obtained by leachate coagulation experiments. Also removal efficiency at mixing ratio 3 corresponded to 500mg/$\ell$ of FeC $l_3$ dosage. it was suggested that pretreatment by mixing of AMD and leachate remove both suspended organic material of leachate and metal of AMD.

  • PDF

Pretreatment by the Process of BAC Fluidized Bed to produce the Biologically Stable Drinking Water (생물활성탄 유동상법에 의한 상수원수의 생물학적 전처리공정)

  • 우달식;남상호
    • Journal of Environmental Health Sciences
    • /
    • v.24 no.1
    • /
    • pp.38-46
    • /
    • 1998
  • This study was to investigate the effects of carbon loadings, temperature and expansion ratio on the waterborne organic removal by the biologically active GAC fluidized bed on a laboratory scale. The raw water to be treated comes from midstream of Han river. BACFB(Biological Activated Carbon Fluidized Bed) process was very effective to remove the biodegradable fraction of dissolved organic matter. The more carbon weighed, the more DOC removed in a range from 16.7 to 133.3 g/l. DOC and UV$_{254}$ were removed more than 40% and 20% above 20$\circ$C respectively. Between 5$\circ$C and 10$\circ$C, DOC and UV$_{254}$ were eliminated about 30% and 15% respectively. In general, even if the temperature was higher, DOC removal was a little sensitive, probably influenced by GAC's residual adsorption capacity. UV$_{254}$ reduction was little fluctuated in accordance with water temperature. The gradual increase in expansion ratio from 10% to 75% didn't greatly affect on the removal of DOC and UV$_{254}$. The expansion ratio, therefore, is not a key factor over the critical expansion ratio.

  • PDF

Cholesterol Removal from Lard with Crosslinked ${\beta}$-Cyclodextrin

  • Kim, S.H.;Kim, H.Y.;Kwak, H.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.9
    • /
    • pp.1468-1472
    • /
    • 2007
  • The present study was carried out to determine the optimum conditions of different factors (ratio of lard to water, ${\beta}$-CD concentrations, mixing temperature, mixing time and mixing speed) on cholesterol reduction from lard by using crosslinked ${\beta}$-CD. Crosslinked ${\beta}$-CD was prepared with adipic acid. When the lard was treated under different conditions, the range of cholesterol removal was 91.2 to 93.0% with 5% crosslinked ${\beta}$-CD, which was not significantly different among treatments. In a recycling study, cholesterol removal with crosslinked ${\beta}$-CD in the first trial was 92.1%, which was similar to that with new crosslinked ${\beta}$-CD. In up to eight time trials, over 90% of cholesterol removal was found. The present study indicated that the optimum conditions for cholesterol removal using crosslinked ${\beta}$-CD were a 1:3 ratio of lard to water, 5% crosslinked ${\beta}$-CD concentration, $40^{\circ}C$ mixing temperature, 1 h mixing time and 150 rpm mixing speed. In addition, crosslinked ${\beta}$-CD made by adipic acid resulted in an effective recycling efficiency.

Flue Gas Sulfur Dioxide Removal Performance of a Bench-Scale Spray Absorption/Drying Reactor (실험실적 규모의 분무흡수건조반응기의 배출가스 중 아황산가스 처리성능 연구)

  • 동종인;구우회;임대현
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.4
    • /
    • pp.449-457
    • /
    • 1996
  • The main purpose of this study was to investigate sulfur dioxide removal performance of flue gas desulfurization system utilizing a Spray Absorption/Drying Reactor. In this system, the size of droplets was considered the most significant factor and tested using a PDA system. Lime slurry flow rate, operating temperature, calcium/sulfur (Ca/S) ratio and applied air pressure were selected as major operation variables and tested/analyzed in terms of system performance. The results are as follows. 1. The $SO_2$ removal efficiencies were 49%, 74%, 85% for Ca$(OH)_2$ slurry flow rate of 10, 20, 30 ml/min, which implies that the increase of slurry flow rate improves removal efficiency. The optimum slurry flow rate in this study was, however, considered 20 ml/min because of constraints of system troubles and absorbent utilization. 2. As Ca/S ratio increased, $SO_2$ removal efficiency was observed to increase. 3. As air pressure, at the atomizing nozzole, increased from 3 to 5 $kg/cm^2, SO_2$ removal efficiency increased from 74% to 80%, because of droplet size reduction due to pressure increase during atomizing process and the increase of surface area, helping mass transfer between gas and liquid phase.

  • PDF

Electrolyte Addition for Enhanced Wastewater Treatment by Electrolysis using Cu Electrode

  • Kim, Woo-Yeol;Yun, Chan-Young;Son, Dong-Jin;Chang, Duk;Kim, Dae-Gun;Hong, Ki-Ho
    • Journal of Electrochemical Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.35-42
    • /
    • 2017
  • In this study, the effect of electrolyte addition on the removal of organics and nutrients in electrochemical wastewater using a copper electrode, and the characteristics of the by-product of electrolysis were investigated. The removal of organics increased significantly as shorter reaction times upon the addition of chloride ion, and most of the electrolysis reaction was completed within 20 min. The reaction rate gradually increased in proportion to the $Cl^-$/COD ratio, whereas the highest removed mass of organic matter per mass of added electrolyte was observed at a $Cl^-$/COD ratio of 1. After the addition of electrolyte, significant removal of ammoniacal nitrogen was observed as a result of the enhanced generation of oxidizers such as hypochlorite. Excellent phosphorus removal was also achieved in a very short reaction time (within 2 min) by electro-coagulation. As the electrolysis progressed, the amount of by-product increased gradually, whereas a decrease of sludge volume index was observed after the addition of electrolyte. This indicated that the settling performance of the by-products was better, and their removal would be easily achieved.