• Title/Summary/Keyword: Removal of dissolved iron

Search Result 39, Processing Time 0.025 seconds

A Role of Dissolved Iron ion in Combined Fenton Reaction for Treatment of TNT Contaminated Soil (오염토양처리를 위한 혼합 Fenton 공정에서 용존 철이온이 오염산화처리에 미치는 역할에 관한 연구)

  • Seo, Seung-Won;Kong, Sung-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.6
    • /
    • pp.76-82
    • /
    • 2006
  • Fenton's reaction are difficult to apply in the field due to the low pH requirements for the reaction and the loss of reactivity caused by the precipitation of iron (II) at neutral pH. Moreover, Fenton-like reactions using iron mineral instead of injection of iron ion as a catalyst are operated to get high removal result at low pH. Because hydroxyl radical can generate at the surface of iron mineral, there are competition with a lot of hydroxide at around neutral pH. On the other side, to operate Fenton's reaction series at neutral pH, modified Fenton reaction is suggested. The complexes, composed by iron ions (ferrous ion or ferric ion)-chelating agent, could be acted as a catalyst and presented in the solution at neutral pH. However, modified Fenton reaction requires a lot of hydrogen peroxide. Accordingly, the purpose of this experiment was to effectively combine Fenton-like reaction and modified Fenton reaction for extending application of Fenton's reaction. i.e., injecting chelating agents in Fenton-like reaction at around neutral pH is increasing the concentration of dissolved iron ion and highly promoting the oxidation effect. 2,4,6-trinitrotoluene (TNT) was used as a probe compound for comparing reaction efficiencies in this study. If the concentration of dissolved iron ion in combined Fenton process were existed more than 0.1 mM, the total TNT removal were increased. Magnetite-NTA system showed the best TNT removal (76%) and Magnetite-EDTA system indicated about 56% of TNT removal. The results of these experiments proved more promoted 40-60% of TNT removal than Fenton-like reaction's.

Degradation of Chlorinated Phenols by Zero Valent Iron and Bimetals of Iron: A Review

  • Gunawardana, Buddhika;Singhal, Naresh;Swedlund, Peter
    • Environmental Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.187-203
    • /
    • 2011
  • Chlorophenols (CPs) are widely used industrial chemicals that have been identified as being toxic to both humans and the environment. Zero valent iron (ZVI) and iron based bimetallic systems have the potential to efficiently dechlorinate CPs. This paper reviews the research conducted in this area over the past decade, with emphasis on the processes and mechanisms for the removal of CPs, as well as the characterization and role of the iron oxides formed on the ZVI surface. The removal of dissolved CPs in iron-water systems occurs via dechlorination, sorption and co-precipitation. Although ZVI has been commonly used for the dechlorination of CPs, its long term reactivity is limited due to surface passivation over time. However, iron based bimetallic systems are an effective alternative for overcoming this limitation. Bimetallic systems prepared by physically mixing ZVI and the catalyst or through reductive deposition of a catalyst onto ZVI have been shown to display superior performance over unmodified ZVI. Nonetheless, the efficiency and rate of hydrodechlorination of CPs by bimetals depend on the type of metal combinations used, properties of the metals and characteristics of the target CP. The presence and formation of various iron oxides can affect the reactivities of ZVI and bimetals. Oxides, such as green rust and magnetite, facilitate the dechlorination of CPs by ZVI and bimetals, while oxide films, such as hematite, maghemite, lepidocrocite and goethite, passivate the iron surface and hinder the dechlorination reaction. Key environmental parameters, such as solution pH, presence of dissolved oxygen and dissolved co-contaminants, exert significant impacts on the rate and extent of CP dechlorination by ZVI and bimetals.

Removal Characteristics of Iron, Manganese and Organics in Ground Water Using Ozonation (오존을 이용한 지하수의 철.망간 및 유기물 제거특성)

  • 선창욱;우달식;남상호
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.2
    • /
    • pp.43-49
    • /
    • 1997
  • Iron and manganese problems in ground water affect far more water systems than almost any other water quality concern. The purpose of this study is to find the optimum condition of ozonation for the removal of dissolved iron, manganese and other organics in the polluted ground water. We proposed 4mg/l, 8mg/l as optimum ozone dose for the removal of $Fe^{2+},{\;}Mn^{2+}$, respectively. The removal efficiencies of $COD_{Mn}$ and $COD_{Cr}$ in ozone dose of 2mg/l - 6mg/l were about 40-50%. The removal efficiency of $NH_{3}-N$ was about 30-40% at pH8.5. In conclusion, it needs further systematic study and research concerned to treatability of $Fe^{2+},{\;}Mn^{2+}$ and biodegradability of organic compounds using Ozonation followed by biological filtration process in ground water treatment train.

  • PDF

Interaction between Selenium and Bacterium and Mineralogical Characteristics of Biotreated Selenium (셀레늄-미생물간의 반응 및 셀레늄 광물화 특성)

  • Lee, Seung-Yeop;Oh, Jong-Min;Baik, Min-Hoon
    • Journal of the Mineralogical Society of Korea
    • /
    • v.24 no.3
    • /
    • pp.217-224
    • /
    • 2011
  • Removal of dissolved selenium by D. michiganensis, a iron-reducing bacterium, and effects of dissolved metal elements such as iron, sulfate, and copper were investigated. Selenide that was reduced from selenite (2 mM) by D. michiganensis was gradually removed from the aqueous medium. As the reduced selenide was combined with aqueous iron, it was precipitated as a nanoparticulate iron-selenide. Sulfate and copper negatively affected the microbial selenite reduction, and the copper was especially toxic to the bacterium, inhibiting a microbial removal of dissolved selenite. These results show that it should be carefully biotreated for a selenium-contaminated site considering in situ sulfate or copper distribution and concentration. Consequently, the formation of iron-selenide by bacteria will be an important measure for preventing a long-distance migration of selenium in the subsurface environments.

Degraded Paddy Soils. I. Theoretical Analysis on the Sultide Formation and the Effect of Iron Hydroxide Upon Removal of Sulfide from Solution

  • Cho, Chai-Moo
    • Applied Biological Chemistry
    • /
    • v.2
    • /
    • pp.9-14
    • /
    • 1961
  • The formation of sulfide from sulfate has been discussed from the thermodynamic principles. No mechanism of the reaction has been presented. From the stoichiometric and Nernst equations for the conversion of sulfate into sulfide, it was concluded that the formation of sulfide from sulfate can take place more readily if pH of a medium is low. The difficulty of this conversion increases with increasing pH. As pH of a medium increases, the degree of dissociation of H₂S into S= increases and this, in turn, renders the chance of precipitation of sulfide as FeS easier. Higher the pH of a soil or medium, greater is the S= concentration. The concentration of ferrous ion required to remove dissolved sulfide in a medium by forming insoluble FeS decreases with increasing pH. From the theory it was pointed out that an application of lime and iron rich foreign substances to a soil may be effective in causing the removal of dissolved sulfide from solution.

  • PDF

Removal of Dissolved Iron in Groundwater by Injection-and-Pumping Technique: Application of Reactive Transport Modeling (주입-양수 기법을 활용한 지하수 내 용존 철 제거: 반응성용질이동모델링의 적용)

  • Choi, Byoung-Young;Yun, Seong-Taek;Kim, Kyoung-Ho;Koh, Yong-Kwon;Kim, Kang-Joo
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.6
    • /
    • pp.29-37
    • /
    • 2007
  • Shallow alluvial groundwaters in Korea of tell exceed the Korean Drinking Water Standard for dissolved iron (0.3 mg/L), which is one of the important water quality problems, especially in the use of bank infiltration technique. Using the reactive transport modeling, in this study we simulated the effectiveness of injection-and-pumping technique to remove dissolved iron in groundwater. The results of simulation showed that pumping of groundwater after injection of oxygenated water into aquifers is very effective to acquire the permissible water quality level. Groundwater withdrawal up to several times of irjected water in volume can be applicable to yield drinkable water. Potential problems such as clogging and permeability lowering due to in-situ precipitation of iron hydroxides may be insignificant. We also discuss on the mechanism and spatial extent of iron removal in aquifer.

A Study of Hexavalent Chromium Reduction by Iron Sulfide (황화철에 의한 6가 크롬의 환원에 관한 연구)

  • Jo, Se-I;Park, Jae-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.6
    • /
    • pp.657-662
    • /
    • 2005
  • Iron sulfide(FeS) is significantly produced through both abiotic and biotic processes in natural sediments and pore waters. In this study, chromium(VI) reaction with iron sulfide at various initial concentrations and at pH values of 4 and 8 was conducted to better understand the interactions between Cr(VI) and Fe(II) species dissolved from iron sulfide in both the aqueous and solid phases. Also, the removal efficiency of iron sulfide was compared with zero valent iron and other iron bearing oxides such as ${\alpha}-Fe_2O_3$, ${\alpha}-FeOOH$ and $Fe_3O_4$. The Cr(VI) removal rate by iron sulfide was higher at pH 4 than at pH 8 because more dissolved Fe(II) existed at pH 4 than at pH 8. Chromium and iron(oxyhydroxide) could be identified on the iron sulfide surface with transmission microscopy imaging and energy dispersive spectroscopy. The removal capacity of iron sulfide was much higher than zero valent iron and other iron oxide minerals due to the synergic effect of hydrogen sulfide and ferrous iron.

Effect of Sludge Concentration on Removal of Heavy Metals from Digested Sludge by Thiobacillus ferrooxidans (Thiobacillus ferrooxidans를 이용한 소화 슬러지의 중금속 제거에 미치는 슬러지 농도의 영향)

  • 류희욱;김윤정;조경숙;강근석;최형민
    • KSBB Journal
    • /
    • v.13 no.3
    • /
    • pp.279-283
    • /
    • 1998
  • To investigate the feasibility of the microbial process for removal of heavy metals from the high solid content sludge, the effect of sludge concentration on the solubilization of heavy metals by an iron oxidizing bacterium Thiolbacillus ferrooxidans was examined. With increasing the sludge concentration, the removal efficiency of heavy metals and the oxidation rate of iron were inhibited. Especially, when the sludge concentration is over 5% (w/v), the activity of T. ferrooxidans was remarkably inhibited. This inhibition is considered to occur due to the dissolved inhibitory materials such as organic compounds, heavy metals, and others which were extracted from the sludge during incubation period. In conclusion, the microbial process by T. ferrooxidans is only effectively used in ranges of 1.3 to 4.0% (w/v) sludge concentration.

  • PDF

Characteristics of manganese removal by ozonation: Effect of existing co-ion and optimum dosage (오존을 이용한 용존성 망간 제거 특성: 공존이온의 영향 및 최적주입량)

  • Kwak, Yeonwoo;Lee, Seulki;Lee, Yongsoo;Hong, Seongho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.2
    • /
    • pp.145-152
    • /
    • 2018
  • This study is focused on manganese (Mn(II)) removal by ozonation in surface water. Instant ozone demand for the water was 0.5 mg/L in the study. When 0.5 mg/L of Mn(II) is existed in water, the optimum ozone concentration was 1.25 mg/L with reaction time 10 minutes to meet the drinking water regulation. The ozone concentration to meet the drinking water regulation was much higher than the stoichiometric concentration. The reaction of soluble manganese removal was so fast that the reaction time does not affect the removal dramatically. When Mn(II) is existed with Fe, the removal of Mn(II) was not affected by Fe ion. However As(V) is existed as co-ion the removal of Mn(II) was decreased by 10%. Adding ozone to surface water has limited effect to remove dissolved organic matter. When ozone is used as oxidant to remove Mn(II) in the water, the existing co-ion should be evaluated to determine optimum concentration.

The Treatment of Acid Mine Drainage - The removal of Iron(Fe) component- (자력에 의한 산성 광산 배수의 처리 - 철(Fe) 성분의 제거-)

  • Song, Kun-Ho;Lee, Kwang-Rae
    • Journal of Industrial Technology
    • /
    • v.32 no.A
    • /
    • pp.21-27
    • /
    • 2012
  • The characteristics of floc formation of the iron(Fe) ions contained in the acid mine drainage was studied for developing the process treating the acid mine drainage. The iron(Fe) ions were formed into flocs by the acid-base reaction with the added $Ca(OH)_2$. The molal ratio of iron(Fe) vs $Ca(OH)_2$ was one of major control variables in treatment; pH change, iron(Fe) ions concentration in treated drainage, DO (dissolved oxygen content). In addition, the air gave much effect on the color of the $iron(Fe)-Ca(OH)_2$ flocs and the attachment to magnet. The attaching to the magnet of the flocs formed in the air was much less than the case without air.

  • PDF