• 제목/요약/키워드: Removal of T-N and T-P

검색결과 443건 처리시간 0.036초

축산폐수의 후처리공정으로서 SBR 적용시 운전인자에 따른 질소와 인의 제거특성에 관한 연구 (A Study on the Removal of Nitrogen and Phosphorus by Operation Mode for Livestock Wastewater Treatment Post-process Using SBR)

  • 최건열;이영신
    • 한국환경보건학회지
    • /
    • 제35권3호
    • /
    • pp.214-219
    • /
    • 2009
  • This study examined the removal efficiency of the nitrogen and phosphorus in order to compensate for the combined process of ATAD(Autothermal Thermophilic Aaerobic Digestion) and EGSB(Expended Granular Sludge Bed), which are treatment methods for livestock wastewater, by introducing SBR(Sequencing Batch Reactor) as post-treatment process. The analysis on the treatment efficiency of each operation mode showed that, in the case of T-N, the treatment efficiency were 67.1% and 74.2% for Run-1 and Run-2, respectively, and in the case of T-P, the values were 71.2 and 74.1, respectively, which are indicating that the treatment efficacy is higher in the condition of Run-1, in which the time period of Anoxic and Aerobic segments were increased. In addition, the result of analyzing removal characteristics of nitrogen and phosphorus by Influx load showed that removal efficiency of nitrogen was better in the case of high influx load than in the case of low influx load. Regardless of Influx load, phosphorus showed constant influx concentration, so that removal efficiency of phosphorus was influenced littler by Influx load than that of nitrogen. This study also fed methanol as an external carbon source and performed experiment to induce denitrification under anoxic condition by using nitrate among nitrogen compounds of SBR reactor, and the results showed that intermittent feeding was more effective in Nitrogen Removal than composite feeding.

Phosphorus Removal from Sewage with the Corrosion of Aluminum and Silver to Pilot-Plant

  • Park, S-I;Park, H-I;Jung, O-J;Shin, D-Y;Cheong, K-H
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2003년도 Challenges and Achievements in Environmental Health
    • /
    • pp.98-101
    • /
    • 2003
  • The pilot scale experiment was performed to investigate phosphorus and nitrogen removal from sewage by intermittently activated sludge process combined with the electrochemical interaction (Localized Corrosion) of aluminum and silver. The average T-N removal rate for HRT of 24hr was 57.4%. It was possible to remove P in sewage to under 1 mg/L with a short HRT of 12 hr using Al and Ag plate but often required additional A1 plate supplement during the operation.

  • PDF

수자원 보전을 위한 유역통합관리 방안에 관한 연구(II) - 오십천 수계의 수질모델링 및 수질 예측 - (Study in the integrated watershade management for conservation of water resources (II) - Water quality modeling and simulation of Oship stream -)

  • 허인량;정의호;권재혁
    • 한국환경보건학회지
    • /
    • 제28권2호
    • /
    • pp.61-69
    • /
    • 2002
  • Oship stream is located nearby south eastern coasts. This study was performed to find out waters quality modeling and then to predict water quality of Oship stream. Based on survey data, BOD, T-N, T-P calibration and verification result were in good agreement with measured value within mean coefficient variance(MSE) value, which were 13.9%, 9.0%, 26.5% and 19.5%, 12.0%, 16.5%, respectively. Sectional water quality predictions of the main stream of Oship stream are executed on the basis of the following cases 1) with sewage treatment of Dogye-eup 2) reduction of mine wastewater treatment of 80% in th basin. As a result, BOD, T-P improvement rates at down stream of Oship stream, case 1) were appeared 12.2%, 22.2%, case 2) maximum sulfate ion and conductivity reduction removal rate of Oship stream were 58%, 68%. The main pollution sources of Oship-stream were almost domestic wastewater and mine wastewater discharged from Dogye-eup which located in uppers stream. The large effects will appear after the construction of Dogye sewage water treatment plant which remove the organic matter and nutrients in these sewage water. The waste water from mine can not easily to treat for characteristics of effluence and economic problems. However, to achieve the goal of water quality in Oship-stream water system, treatments of those are necessary.

기성품과 맞춤형 임플란트 지대주 나사의 풀림 토크 비교 (Comparison of removal torque between prefabricated and customized abutment screw)

  • ;김지환;김무성;박영범;심준성
    • 대한치과보철학회지
    • /
    • 제50권4호
    • /
    • pp.243-248
    • /
    • 2012
  • 연구 목적: 본 연구의 목적은 임플란트 지대주 연결에 사용되는 기성품 나사와 맞춤형 나사의 풀림 토크를 비교하는 것이다. 연구 재료 및 방법: 세가지 임플란트 시스템에(Osstem, Astra, Zimmer) 대해 고정체와 지대주의 연결에 기성품 나사군(대조군)과 맞춤형 나사군(실험군)으로 총 6군(n = 6)으로 나누었다. 조임 토크조절은 디지털 토크 측정기를 이용하였으며 각 임플란트 제조사가 추천한 조임 토크 값을 적용하였다. 체결 10분 후 동일한 조임 토크를 다시 적용하고 5분 후에 풀림 토크력을 측정하였다. 이 과정을 10회 반복 측정하였다. 반복 하중 실험에서는 6개 군(n = 3)에 대해 체결 10분 후 2차 조임 토크를 적용하고 $30^{\circ}$ 경사로 50 N 하중으로 총 1,000,000번 반복 하중을 가하였다. 반복 하중 적용 이후 풀림 토크값을 측정하였다. 통계 방법으로는 10회 반복 측정에서 풀림 토크값의 차이를 비교하기 위해 repeated measures of ANOVA test (${\alpha}$=.05)를 사용하였고, 반복 하중 후 풀림 토크값의 차이를 비교하기 위해서 각 시스템별 Independant t-test로 통계 처리하였다. 결과: 모든 군에서 반복 횟수가 증가할수록 풀림 토크값이 유의성 있게 감소하는 것으로 나타났다(P<.05). 10회 반복 측정 실험에서는 세 종류의 임플란트에서 대조군(기성품나사)과 실험군(맞춤형 나사) 간에 풀림 토크값은 유의차가 없었다(P>.05). 반복 하중 실험에서 세가지 시스템에서 대조군과 실험군 간의 풀림 토크력은 유의한 차이가 없었다(P>.05). 결론: 반복 측정된 풀림력 검사와 반복 하중을 적용 후 풀림력 검사에서 맞춤형 나사와 기성품 나사의 풀림력은 유의한 차이가 없었다.

고수부지활용 수질정화 자유수면 인공습지의 초기처리수준 (Treatment Efficiency of a Surface - Flow Wetland System Constructed on Floodplain)

  • 양홍모
    • 한국환경농학회지
    • /
    • 제20권4호
    • /
    • pp.277-283
    • /
    • 2001
  • This paper presents treatment efficiency and plant growth of a surface-flow constructed wetland system (30 meter in length and 10 meter in width) over one year after its establishment on a floodplain of a stream. Cattails (Typha angustiflora) grown on pots were transplanted on one half of its area from inlets and reeds (Phragmites australis) on another half from an outlet. Effluent discharged from a secondary-level treatment plant was funneled into the system. The stems of cattails and reeds emerging in April 2001 grew up to 165.9 cm and 95.3 cm, respectively until July 2001. The number of stems of cattails arid reeds in July 2001 increased by 65% and 100%, respectively, compared with that just after their planting. The growth of cattails was better than that of reeds during study period. The removal rates for SS, $BOD_5$, T-N and T-P was 33%, 43%, 31%, and 51%, respectively. The system was inundated seven times by storms over the monitoring period, which disturbed its environment and led to its lower treatment rates. The increase of SS concentration in effluent after inundation of the system was attributed to the falls of soil particles onto its water surface, which had been attached to the emergent plants by floods. Purification rates for T-N were relatively low for the period of late fall through winter until early spring due to lower water temperature which may have retarded microbial nitrification and denitrification mechanisms. Reduction in T-P concentration during fall and winter was relatively higher than that during summer and spring, which may have resulted from no system perturbations by floods and heavy storms during fall and winter.

  • PDF

SBR을 이용한 하수와 우사폐수로 구성된 혼합폐수의 영양소 제거 (The Nutrient Removal of Mixed Wastewater composed of Sewage and Stable Wastewater using SBR)

  • 김홍태
    • 한국환경과학회지
    • /
    • 제8권5호
    • /
    • pp.617-623
    • /
    • 1999
  • This study was carried out to obtain the optimal operating parameter on organic matters and nutrient removal of mixed wastewater which was composed of sewage and stable wastewater using SBR. A laboratory scale SBR was operated with An/Ae(Anaerobic/Aerobic) ratio of 3/3, 2/4 and 4/2(3.5/2.5) at organic loading rate of 0.14 to 0.27 kgBOD/$m^3$/d. TCOD/SCOD ratio of mixed wastewater was 3, so the important operating factor depended upon the resolving the particulate parts of wastewater. Conclusions of this study were as follows: 1) For mixed wastewater, BOD and COD removal efficiencies were 93-96% and 85-89%, respectively. It was not related to each organic loading rate, whereas depended on An/Ae ratio. During Anarobic period, the amount of SCOD consumption was very little, because ICOD in influent was converted to SCOD by hydrolysis of insoluble matter. 2) T-N removal efficiencies of mixed wastewater were 55-62% for Exp. 1, 66-76% for Exp. 2, and 67-81% for Exp. 3, respectively. It was found that nitrification rate was increased according to organic concentration in influent increased. Therefore, the nitrification rate seemed to be achieved by heterotrophs. During anoxic period, denitrification rate depended on SCOD concentration in aerobic period and thus, was not resulted by endogenous denitrification. However, the amount of denitrification during anaerobic period were 3.5-14.1 mg/cycle, and that of BOD consumed were 10-40 mg/cycle. 3) For P removal of mixed wastewater, EBPR appeared only Mode 3($3^*$). It was found that the time in which ICOD was converted to VFA should be sufficient. For mode 3 in each Exp., P removal efficiencies were 74, 87, and 81%, respectively. But for 45-48 of COD/TP ratio in influent, P concentration in effluent was over 1 mg/L. It was caused to a large amount of ICOD in influent. However, as P concnetration in influent was increased, the amounts of P release and uptake were increased linearly.

  • PDF

식물정화조를 이용한 공업용 폐수의 정화 및 재활용 사례 (The Case of Industrial Factory Wastewater Treatment and Reusing by Using of Constructed Wetland)

  • 김혜주;이옥하
    • 한국환경생태학회지
    • /
    • 제16권2호
    • /
    • pp.179-187
    • /
    • 2002
  • 유기물이 함유된 공업용 폐수(2차처리수)의 수질을 정화하기 위해 2000년 7~10월에 친환경적인 방법인 식물정화조를 조성하여 하천의 수질 및 지하수를 보전하고 공업단지내에서 생물서식공간과 휴게공간을 제공하고자 본 실험을 진행하였다 식물정화조의 크기는 10m$\times$6m(상부면)로 1일 처리용량은 2.5㎥였다. 폐수는 1일 4회, 6시간 간격으로 0.625㎥씩 나누어 처리하였다. 처리효율을 높이기 위해 수직흐름방식을 채택하였고, 배수층은 모래와 자갈을 2:1의 비율로 혼합하여 깊이 1.0m로 조성하였다. 식물정화조 내에는 갈대, 부들, 골풀, 노랑꽃창포 등의 다년생 정수식물을 20본/㎥ 식재하였다. 처리수 재활용 차원에서 생물종다양성을 증진시키는 자연형 연못을 조성하였으며, 이를 환경교육장으로 활용하기 위해 관찰데크, 안내해설판 등을 도입하였다. 실험결과 BOD$_{5}$, COD, T-N, T-P 등의 제거에 상당한 효과가 있는 것으로 나타났고, 생태계 모니터링 결과, 생물서식공간(비오톱)으로서의 기능이 점진적으로 향상되고 있는 것으로 나타났다.

새로운 타이타늄 구성요소를 사용한 내부연결 임플란트용 지르코니아 지대주의 동적하중 후 나사 제거력 (Removal torque of a two-piece zirconia abutment with a novel titanium component in an internal connection implant system after dynamic cyclic loading)

  • 이주희
    • 대한치과보철학회지
    • /
    • 제55권2호
    • /
    • pp.151-155
    • /
    • 2017
  • 목적: 이 연구의 목적은 새로운 타이타늄 구성요소를 가진 지르코니아 지대주의 나사 제거력의 변화에 대해 알아보는 것이다. 내부연결 임플란트를 위한 새로운 지르코니아 지대주의 동적하중 후 지대주 나사의 제거력을 기존의 타이타늄 지대주와 비교하여 분석하였다. 재료 및 방법: 내측연결 임플란트와 타이타늄 지대주, 타이타늄 구성요소를 가진 지르코니아 지대주를 준비하였다. 12개의 내부연결형 임플란트에 6개의 타이타늄 지대주를 연결하고(대조군), 6개의 타이타늄 구성요소를 가진 지르코니아 지대주(실험군)를 30 Ncm의 토크로 연결한 후 동적하중 전후의 나사 제거력을 측정하였다. 동적 만능재료시험기를 사용하여 연결체의 장축과 30도 각도를 이루도록 하고 300 N 하중크기로 100만번의 하중이 가해졌다. 동적하중 전후의 지대주 나사 제거력을 t검정을 통해 신뢰구간 95%로 통계적 유의성을 검증하였다. 결과: 두 그룹 모두에서 동적하중 후 나사 풀림을 보이지 않았다. 동적 하중 전후의 나사 제거력은 두 그룹 모두에서 통계적으로 유의한 차이가 있게 나타났다(P < .05). 동적 하중 전후의 나사 제거력 차이는 대조군에서 $-7.25{\pm}1.50Ncm$, 실험군에서 $-7.33{\pm}0.93Ncm$ 로 나타났다. 통계분석 결과 두 군간에 나사 제거력 차이에서는 유의한 차이를 보이지 않았다(P > .05). 결론: 이 실험의 결과에 한하여 타이타늄 구성요소를 사용한 지르코니아 지대주의 동적하중 후 지대주 나사 제거력의 변화는 타이타늄 지대주와 통계학적으로 유의한 차이를 보이지 않았다.

자연정화공법에 의한 인공습지 축산폐수처리 시스템의 최적 조합방법 및 부하량 (Optimum Configuration Method and Livestock Wastewater Loding for Treating Livestock Wastewater in Constructed Wetlands by Natural Purification Method)

  • 박종환;서동철;김아름;김성헌;이성태;정태욱;최정호;김현욱;조주식;허종수
    • 한국토양비료학회지
    • /
    • 제44권2호
    • /
    • pp.278-284
    • /
    • 2011
  • 축산농가에서 소규모로 발생하는 축산폐수를 인공습지에서 효율적으로 처리하기 위한 최적 조합방법 및 부하량을 조사하기 위해 호기성조, 혐기성조 및 무산소조를 구분하여 9개 시스템의 소형 축산폐수처리장치를 설계 및 제작한 다음 조합방법별 및 부하량별에 따른 수처리 효율을 조사하였다. 축산폐수처리장치의 조합방법에 따른 처리효율을 조사한 결과 COD 처리효율은 호기-호기 조합형과 호기-혐기 조합형이 다른 조합방법에 비해 높았으며, T-N 처리효율은 호기성조-혐기성조 조합형이 다른 조합방법에 비해 높은 처리효율을 보였다. 또한 조합방법에 따른 SS 및 T-P 처리효율은 큰 차이가 없었다. 소형 축산폐수 처리장치에서 부하량에 따른 처리효율을 조사한 결과 SS를 제외한 COD, T-N 및 T-P 처리효율은 축산폐수 부하량 $100L\;m^{-2}\;day^{-1}$까지 안정적이었으나, $100L\;m^{-2}\;day^{-1}$ 이상의 부하량에서는 처리효율이 약간 감소하였다. 소형 축산페수처리장치에서 SS처리의 경우 부하량 $200L\;m^{-2}\;day^{-1}$까지 안정적인 처리효율을 보였으며, 그 이상의 부하량도 처리가 가능할 것으로 판단된다. 이상의 결과 미루어 볼 때, 축산폐수를 처리하기 위한 소형 축산폐수처리장치의 최적조합방법은 호기-혐기 조합이었으며, 부하량은 $100L\;m^{-2}\;day^{-1}$이었다.

슬러리형 돈사폐수에서 자원회수와 질소제거를 위한 순차적 결합공정 제안 (A Proposal of Sequencing the Combined Processes for Resources Recovery and Nitrogen Removal from Piggery Waste)

  • 황인수;민경석;배진연
    • 대한환경공학회지
    • /
    • 제28권1호
    • /
    • pp.61-66
    • /
    • 2006
  • 슬러리 형태의 돈사폐수로부터 자원회수와 질소제거를 위하여 순차적으로 ADEPT(Anaerobic digestion elutriated phased treatment) 공정과 SHARON(Single reactor system High Ammonium Removal Over nitrite)-ANAMMOX(Anaerobic ammonium oxidation)공정을 결합하여 운전하였다. ADEPT 공정은 부하율 3.95 gSCOD/L-day에서 운전되었고, SCOD 생성율과 산생성율은 각각 5.3 gSCOD/L-day와 3.3 gVFAs/L-day(as COD)였다. 가수분해에 의한 VS감소와 SCOD생성율은 각각 13%와 0.19 $gSCOD_{prod}/gVS_{feeding}$였으며, 산생성율은 0.80 $gVFAs/gSCOD_{prod.}$였다. 메탄발효조에서 가스생성율과 메탄함량은 각각 2.8 L/day($0.3m^3CH_4/kgCOD_{removal}\;@STP$) 및 77%였다. 운전조건에서 $NH_4-N$ 94.1% (TKN으로서 86.5%) 및 T-P 87.3%가 제거되었다.