• Title/Summary/Keyword: Removal efficiency rate

Search Result 1,297, Processing Time 0.023 seconds

Studies on the Water Purification Using Water Parsley (미나리 (Oenanthe javanica(Blume) DC)를 이용한 수질정화에 관한 연구)

  • 권성환;나규환;류재근;김종택
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.3
    • /
    • pp.56-63
    • /
    • 1996
  • The results of the water purification studies using water parsley (Oenanthe javanica) were obtained as follows. The removal rate of nutrient salts increased with longer plant growth periods. The results of this study use the assumption, log(T+1) = $K(C_0-C)^A$, based on Prakish's Theory. The initial concentration was calculated from experimental data. A and K are closely related to the initial concentration. It is possible to model the concentration of residual salts, as time goes by, if concentration is constant. It was observed that water parsley neutralizes acid and alkali substances promptly. The maximum suitable neutralization period is 48 hours. But water parsley withered up in strong acid and alkali solutions within a week. The removal efficiency of Cd progresses in 2 steps, which are unrelated to the initial concentration of Cd. The first part of the curve shows the concentration rapid rate of Cd removal, followed by a levelling off. The removal rate of $NO_x-N$ in the sample water tank containing 0.5 ppm Cd was between 50~80% but the removal rate was less than 20% for the higher concentration. On the other hand, increased amounts of $PO_4-P$ in the sample water tank from the third day on suspected that $PO_4-P$ was desorbed from the water parsley. The accumulation efficiency of Cd in plant was increased in proportion to the initial concentration of Cd. The accumulation phenomenon was observed in the tanks more than 50~100 times.

  • PDF

Optimization of Gas Mixing-circulation Plasma Process using Design of Experiments (실험계획법을 이용한 가스 혼합-순환식 플라즈마 공정의 최적화)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.23 no.3
    • /
    • pp.359-368
    • /
    • 2014
  • The aim of our research was to apply experimental design methodology in the optimization of N, N-Dimethyl-4-nitrosoaniline (RNO, which is indictor of OH radical formation) degradation using gas mixing-circulation plasma process. The reaction was mathematically described as a function of four independent variables [voltage ($X_1$), gas flow rate ($X_2$), liquid flow rate ($X_3$) and time ($X_4$)] being modeled by the use of the central composite design (CCD). RNO removal efficiency was evaluated using a second-order polynomial multiple regression model. Analysis of variance (ANOVA) showed a high coefficient of determination ($R^2$) value of 0.9111, thus ensuring a satisfactory adjustment of the second-order polynomial multiple regression model with the experimental data. The application of response surface methodology (RSM) yielded the following regression equation, which is an empirical relationship between the RNO removal efficiency and independent variables in a coded unit: RNO removal efficiency (%) = $77.71+10.04X_1+10.72X_2+1.78X_3+17.66X_4+5.91X_1X_2+3.64X_2X_3-8.72X_2X_4-7.80X{_1}^2-6.49X{_2}^2-5.67X{_4}^2$. Maximum RNO removal efficiency was predicted and experimentally validated. The optimum voltage, air flow rate, liquid flow rate and time were obtained for the highest desirability at 117.99 V, 4.88 L/min, 6.27 L/min and 24.65 min, respectively. Under optimal value of process parameters, high removal(> 97 %) was obtained for RNO.

Evaluation of the Applicability of Livestock Wastewater Treatment using Boron-Doped Diamond (BDD) Electrodes (BDD 전극을 이용한 축산폐수 처리의 적용성 평가)

  • Hyun-Gu Kim;Dae-Hee Ahn
    • Journal of Environmental Science International
    • /
    • v.32 no.6
    • /
    • pp.465-475
    • /
    • 2023
  • In this study, we evaluated the treatment efficiency of livestock wastewater by altering the current density using boron-doped diamond (BDD) electrodes. As the current density was adjusted from 10 to 35 mA/cm2, the removal efficiency of organic matter increased from 22.2 to 71.5%. Similar to that of organic matter, the removal efficiency of color increased with increasing current density up to 85.7%, indicating a higher removal efficiency for color than that of organic matter. The removal efficiency of ammonia nitrogen increased from 14.6 to 53.3% as the current density increased, but it was lower than that of organic matter. In addition, the removal of organic matter, color, and ammonia nitrogen followed first-order reactions, according to the reaction rate analysis. The energy consumption ranged from 4.87 to 8.33 kWh/kg COD, and it was found that the organic matter removal efficiency was more efficient at high current densities. Based on various analyses, the optimal current density was 20 mA/cm2, and the corresponding energy consumption was 6.824 kWh/kg COD.

A Study on the Phenomena of Dust Removal by the Layout Changes in the Turbulent Type Clean Room (난류형 클린룸내의 Layout 변화에 따른 분진제거 특성에 관한 연구)

  • Kim, Yeon-Hee;Kim, Hong
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.5 s.77
    • /
    • pp.46-52
    • /
    • 2006
  • The purpose of this paper is to investigate the removal efficiency of fine dusts as the configuration condition of machinery and equipments in Clean Room and to analyze the flowing behaviors of fine dusts as the layout of Clean Room. The layout of the Clean Room was classified into side layout type, 2 center line type and center concentration type layout, and the flow rates used in this research were 0.22m/s, 0.44m/s and 0.80m/s. Dust removal efficiency as layout change was decreased 37% for side layout type, 31% for 2 center line type and 20% for center concentration type layout at the flow rate of 0.22m/s, compared with the state without machinery and equipments in Clean Room. The efficiency was decreased 42% for side layout type, 22% for 2 center line type and 8% for center concentration type layout at the flow rate of 0.44m/s, and decreased 20% for side layout type, 18% for 2 center line type and 10% for center concentration type layout at the flow rate of 0.80m/s. According to the result of dust removal behavior, $0.3{\mu}m,\;1{\mu}m\;and\;3{\mu}m$ dust except for $5{\mu}m$ showed the higher change of the behavior in side layout type than in center concentration type layout due to the change of air flow. It was confirmed that removal behavior depends on the layout of machinery and equipments as the dust size decreases.

Efficiency of Livestock Farming Wastewater Treatment by Trickling Filters (撒水濾床法에 依한 畜産廢水의 處理效果에 관한 연구)

  • Ahu, Soo Mi
    • Journal of Environmental Health Sciences
    • /
    • v.11 no.2
    • /
    • pp.17-27
    • /
    • 1985
  • The objectives of this study is to examine efficiency of swinery wastewater treatment by trickling filters' pilot plant. The results of this study are as follows: 1. The characteristics of sample. The BOD$_5$ was from 2,450 to 2,880mg/l, COD(KMnO$_4$ acid method) was from 910 to 1,064mg/l, and SS was from 920 to 990mg/l. The pH of influent was from 7.3 to 7.6, and the temperature of water was from 17.0$\circ$C to 22.5$\circ$C. 2. For experiment by recirculation, the BODs removal efficiency is 65.2% at recirculation ratio (r)=0, and 70.7% at r=1. The ramoval efficiency of this study is higher than NRC formula of U.S.A.. The recirculation is not significant effect on removal efficiency. 3. For experiment by hydraulic load, the BOD$_5$ removal rate decreased from 73.1% at $3.1m^3/m^2\cdot d$ to 65.3% at $9.2m^3/m^2\cdot d$. The design formula of this study which shows the removal rate of soluble BOD is $Le/Li =10^{-0.24} D/Q^{0.24}$ (Q: hydraulic load, D: depth of filter). 4. For experiment by organic load, the BOD$_5$ removal rate is increased from 70.2% at $0.77kg/m^3\cdot d$ to 75.4% at $4.28kg/m^3\cdot d$. We can obtain the straight line y=0.749 x (y: removed BOD, x :applied BOD) by the least squares method. 5. We can know that trickling filters is strong with the hydraulic load and the organic matter shock load. Here, we can judge that trickling filters is a good method for the treatment of swinery wastewater which containing high concentrated organic matter.

  • PDF

Estimation of the Reactor Volume Ratio for Nitrogen Removal in Step-Feed Activated Sludge Process (단계 주입 활성슬러지공법에서 질소제거를 위한 반응기 용적비 추정)

  • Lee, Byung-Dae
    • Journal of the Korean Applied Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.130-136
    • /
    • 2006
  • Theoretical total nitrogen removal efficiency and reactor volume ratio in oxic-anoxic-oxic system can be found by influent water quality in this study. The influent water quality items for calculation were ammonia, nitrite, nitrate, alkalinity, and COD which can affect nitrification and denitrification reaction. Total nitrogen removal efficiency depends on influent allocation ratio. The total nitrogen removal follows the equation of 1/(1+b). Optimal reactor volume ratio for maximum TN removal efficiency was expressed by those influent water quality and nitrification/denitrification rate constants. It was possible to expect optimal reactor volume ratio by the calculation with the standard deviation of ${\pm}14.2$.

Removal of NH(sub)3-N by Using Immobilized Nitrifier Consortium in PVA[Polyvinyl Alcohol]-I. Effect of Packing Fraction and Aeration Rate on Ammonia Nitrogen Removal (PVA에 고정화된 질화세균군에 의한 암모니아성 질소 제거 I. 충진율 및 공기 유입량이 암모니아성 질소제거에 미치는 영향)

  • 서근학;김병진;오창섭
    • KSBB Journal
    • /
    • v.16 no.3
    • /
    • pp.314-319
    • /
    • 2001
  • A nitrifier consortium immobilized in polyvinyl alcohol was used to remove ammonia nitrogen from synthetic wastewater in an airlift bioreactor. The minimum aeration rates were 0.4, 0.6, 0.8 and 1.0 vvm for 5, 10, 15 and 20% immobilized bead packing volume fraction, respectively. The efficient packing fraction and the aeration rate for ammonia nitrogen removal were 15% and 2.4 vvm, respectively. With a hydraulic retention time of 0.5hr, the removal rate and the efficiency of ammonia nitrogen removal were 1685 g/㎥$.$day and 48% at an influent ammonia nitrogen concentration of 75 g/㎥.

  • PDF

A Study on Electrodeionization for Purification of Primary Coolant of a Nuclear Power Plant (원자력 발전소의 일차 냉각수 정화를 위한 전기탈이온법의 기초연구)

  • Yeon, Kyeong-Ho;Moon, Seung-Hyeon;Jeong, Cheorl-Young;Seo, One-Sun;Chong, Sung-Tai
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.2
    • /
    • pp.73-86
    • /
    • 1999
  • The ion-exchange method for the purification of primary coolant has been used broadly in PWR(pressurized water reactor)-type nuclear power plants due to its high decontamination efficiency, simple system, and easy operation. However, its non-selective removal of metal and non-radionuclides shortens its life, resulting in the generation of a large amount of waste ion-exchange resin. In this study, the feasibility of electrodeionization (EDI) was investigated for the purification of primary cooling water using synthetic solutions under various experimental conditions as an alternative method for the ion exchange. The results shows that as the feed flow-rate increased, the removal efficiency increased and the power consumption decreased. The removal rate was observed as a 1000 decontamination factor(DF) at a nearly constant level. For the synthetic solution of 3 ppm TDS (Total Dissolved Solid), the power consumption was 40.3 mWh/L at 2.0 L/min of feed flow rate. The higher removal rate of metal species and lower power consumption were obtained with greater resin volume per diluting compartment. However, the flow rate of the EDI process decreased with the elapsed time because of the hydrodynamic resistivity of resin itself and resin fouling by suspended solids. Thus, the ion-exchange resin was replaced by an ion-conducting spacer in order to overcome the drawback. The system equipped with the ion-conducting spacer resolved the problem of the decreasing flow rate but showed a lower efficiency in terms of the power consumption, the removal rate of metal species and current efficiency. In the repeated batch operation, it was found that the removal efficiency of metal species was stably maintained at DF 1000.

  • PDF

Effect of Operating Condition of Stripping Process on Ammonia Removal for Pre-treatment of Swine Wastewater (축산폐수 전처리를 위한 암모니아 탈기공정의 운전조건이 암모니아 제거에 미치는 영향)

  • Whang, Gye-Dae;Cho, Young-Moo
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.1
    • /
    • pp.86-92
    • /
    • 2004
  • Lab-scale experiments have been carried out to investigate ammonia stripping with a modified spray tower for removing ammonia nitrogen from swine wastewater. The operating conditions such as initial pH, temperature, air flow, hole size of distributor determining the diameter of water drops, and influent solids concentration were closely examined focusing on removal efficiency of ammonia. As a result of the experiment, in order to achieve high rate of ammonia removal by the air stripping system, the air flow rate must be supplied at high rate with sufficiently high initial pH, temperature. The optimum operating condition to meet the residual ammonia concentration of 300 mg/L was the initial pH of 11.0 at $35^{\circ}C$ with the air flow rate of 20 L/min. It also showed that the smaller hole size is, the higher removal rate of ammonia is expected. However, when used a small sized distributor (2 mm), the flooding problem at the upper column occurred due to clogging of the hole. With regard to the influent solids concentration, it was showed that the lower concentration of solids, the higher removal rate of ammonia. The removal of particulate materials in influent led to improve the removal efficiency of ammonia, rather than to control the operating condition including initial pH, temperature, and air flow. The empirical correlation between KLa and operating parameters would be driven as, $K_{La}=(0.0003T-0.0047){\cdot}G^{0.3926}{\cdot}L^{-0.5169}{\cdot}C^{-0. 1849}$. The calculated $K_{La}$ from proposed formula can be used effectively to estimate the optimum reaction time and to calculate the volume of modified spray tower system.

TREATMENT OF HIGH-CONCENTRATION SWINE WASTEWATER BY ANAEROBIC DIGESTION AND AN AQUATIC PLANT SYSTEM

  • Kim, B.U.;Kwon, J.H.
    • Environmental Engineering Research
    • /
    • v.11 no.3
    • /
    • pp.134-142
    • /
    • 2006
  • The treatment of high-strength swine wastewater by anaerobic digestion combined with an aquatic plant system was investigated. Anaerobic digestion of swine wastewater gave volatile solids (VS) removal efficiencies of 43.3%, 52.1% and 54.5% for hydraulic retention times (HRTs) of 20, 30, 40 days, respectively. The removal efficiencies of VS, total chemical oxygen demand (TCOD) and soluble chemical oxygen demand (SCOD) decreased with increasing VS volumetric loading rate (VLR). Higher organic removal efficiency was observed at longer HRTs for the same VS volumetric loading rate. As VS volumetric loading rate increased, biogas production increased and the methane content of the biogas decreased. Experiments using duckweed (Lemna species) as an aquatic macrophyte gave the following results. In the case of nitrogen, removal efficiency was above 60% and effluent concentration was below 10.0 mg/L when the influent ammonia-N loading was about $1.0\;g/m^2/day$. In the case of phosphorus, removal efficiency was above 55% and effluent concentration was below 2.0 mg/L when the influent $PO_4$-P loading was about $0.15\;g/m^2/day$. In addition, crude protein and phosphorus content of duckweed biomass increased from 15.6% to 41.6% and from 0.8% to 1.6%, respectively, as the influent nutrient concentration increased. The treatment of high-strength swine wastewater by anaerobic digestion combined with an aquatic plant system offers good performance in terms of organics and nutrient removal for relatively low operation and maintenance costs. The results indicate that under appropriate operational conditions, the effluent quality is within the limits set by Korean discharge criteria.