• 제목/요약/키워드: Removal Efficiency of pollutants

검색결과 336건 처리시간 0.032초

Electrochemical Removal Efficiency of Pollutants on ACF Electrodes

  • Oh, Won-Chun;Park, Joung-Sung;Lee, Ho-Jin;Yum, Min-Hyung
    • Carbon letters
    • /
    • 제5권4호
    • /
    • pp.191-196
    • /
    • 2004
  • The electrochemical removal (ECR) of water pollutants by activated carbon fiber (ACF) electrodes from wastewater was investigated over wide range of electrochemical reaction time. The ECR capacities of ACF electrodes were associated with their internal porosity and were related to physical properties and to reaction time. And, surface morphologies and elemental analysis for the ACFs after electrochemical reaction are investigated by SEM and EDX to explain the changes in adsorption properties. The FT-IR spectra of ACFs for the investigation of functional groups show that the electrochemical treatment is consequently associated with the homogeneous removal of pollutants with the increasing surface reactivity of the activated carbon fiber surfaces. The ACFs were electrochemically reacted to waste water to investigate the removal efficiency for the COD, T-N and T-P. From these removal results of pollutants using ACFs substrate, satisfactory removal performance was obtained. The outstanding removal effects of the ACFs substrate were determined by the properties of the material for adsorption and trapping of organics, and catalytic effects.

  • PDF

Evaluation of Green House Gases (GHGs) Reduction Plan in Combination with Air Pollutants Reduction in Busan Metropolitan City in Korea

  • Cheong, Jang-Pyo;Kim, Chul-Han;Chang, Jae-Soo
    • Asian Journal of Atmospheric Environment
    • /
    • 제5권4호
    • /
    • pp.228-236
    • /
    • 2011
  • Since most Green House Gases (GHGs) and air pollutants are generated from the same sources, it will be cost-effective to develop a GHGs reduction plan in combination with simultaneous removal of air pollutants. However, effects on air pollutants reduction according to implementing any GHG abatement plans have been rarely studied. Reflecting simultaneous removal of air pollutants along with the GHGs emission reduction, this study investigated relative cost effectiveness among GHGs reduction action plans in Busan Metropolitan City. We employed the Data Envelopment Analysis (DEA), a methodology that evaluates relative efficiency of decision-making units (DMUs) producing multiple outputs with multiple inputs, for the investigation. Assigning each GHGs reduction action plan to a DMU, implementation cost of each GHGs reduction action plan to an input, and reduction potential of GHGs and air pollutants by each GHGs reduction action plan to an output, we calculated efficiency scores for each GHGs reduction action plan. When the simultaneous removal of air pollutants with the GHGs reduction were considered, green house supply-insulation improvement and intelligent transportation system (ITS) projects had high efficiency scores for cost-positive action plans. For cost-negative action plans, green start network formation and running, and daily car use control program had high efficiency scores. When only the GHGs reduction was considered, project priority orders based on efficiency scores were somewhat different from those when both the removal of air pollutants and GHGs reduction were considered at the same time. The expected action plan priority difference is attributed to great difference of air pollutants reduction potential according to types of energy sources to be reduced.

TiO2를 이용한 저농도 유기오염물질 제거에 관한 연구 (A Study on Low Concentrations of Organic Pollutants Removal using TiO2)

  • 이용훈;강선홍
    • 상하수도학회지
    • /
    • 제27권1호
    • /
    • pp.83-89
    • /
    • 2013
  • Microbiological treatment, chlorination, and ozonation are usually used for water treatment. However, there is weakness that these methods can't decompose and eliminate recalcitrant organic pollutants perfectly. It is possible to eliminate recalcitrant organic pollutants when photocatalysis of $TiO_2$ is used. In this study, the removal efficiencies of organic pollutants by using photocatalyst of $TiO_2$ in the slightly polluted golf club water hazard and a river were investigated. The amount of $TiO_2$ was divided into three categories of 1 g/L, 2 g/L and 4 g/L in order to investigate the adequate amount of $TiO_2$ and the removal efficiency. UV light was used as a light source for the reaction of photocatalyst. As a conclusion in this study, the efficiency of turbidity removal was increased in proportion to the amount of $TiO_2$ until 4 hours. After then the turbidity was gradually decreased. Finally, the optimum concentration of $TiO_2$ was 4 g/L. The efficiency of COD removal was increased in proportion to the amount of $TiO_2$ regardless of time.

자연형 도로 비점오염저감시설의 저감효율 및 적용성 연구 (A Study on Removal Efficiency and Applicability of Natural Type Road Non-point Pollutant Reduction Facilities)

  • 이상혁;조혜진;김이형
    • 한국도로학회논문집
    • /
    • 제16권6호
    • /
    • pp.9-17
    • /
    • 2014
  • PURPOSES : The purpose of this study is to assess removal efficiency of non-point pollutants and applicability for non-point pollutant reduction facilities by conducting the demonstration project operation. METHODS : In order to analyze removal efficiency of non-point pollutants for facilities such as a grassed swale, a small constructed wetland, a free water surface wetland, a horizontal sub-surface flow wetland, and a sand filtration, the field data including specifications of facilities, rainfall, inflow and runoff rainfall effluent etc. was acquired after occurring rainfall events, and the acquired data was analyzed for removal efficiency rate to assess road non-point pollutants facilities using event mean concentration (EMC) and summation of load (SOL) methods. RESULTS : The results of analyzing rainfall effluent, non-point pollutant sources showed that total suspended solid (TSS), chemical oxygen demand (COD), biochemical oxygen demand (BOD), total nitrogen (TN), total phosphorus (TP), chrome (Cr), zinc (Zn), and lead (Pb) can be removed through non-point pollutant reduction facilities by 60.3% ~ 100%. Especially removal efficiency of TSS, COD and BOD is relatively higher than removal efficiency of other non-point pollutant sources in all kind of non-point pollutant facilities. CONCLUSIONS : Based on the result of this study, even though natural type of non-point pollutant reduction facilities for roads occupy small areas comparing with drainage basin areas, most of non-point pollutant sources would be removed through the facilities.

Electro-chemical Removal Properties of Water Pollutants by Ag-ACF from Piggery Waste

  • Oh, Won-Chun;Bae, Jang-Soon;Ko, Young-Shin
    • Carbon letters
    • /
    • 제7권2호
    • /
    • pp.105-113
    • /
    • 2006
  • The electro-chemical removal (ECR) of water pollutants by metal-ACF electrodes from wastewater was investigated over wide range of ECR time. The ECR capacities of metallic ACF electrodes were related to physical properties such as adsorption isotherm, surface area and pore size and to reaction time. Surface morphologies and elemental analysis for the metal supported ACFs after electro-catalytic reaction were investigated by scanning electron microscopy (SEM) and energy disperse X-ray (EDX) to explain the changes in adsorption properties. The IR spectra of metallic ACFs for the investigation of functional groups show that the electro-catalytic treatment is consequently associated with the removal of pollutants with the increasing surface reactivity of the activated carbon fibers. The metal-ACFs were electro-catalytically reacted to waste water to investigate the removal efficiency for the COD, T-N, $NH_4$-N, $NO_3$-N and $NO_2$-N. From these removal results of the piggery waste using metallic ACFs substrate, satisfactory removal performance was achieved. The removal efficiency of the metallic ACFs substrate was mainly determined by the properties of the material for adsorption and trapping of organics, and catalytic effects.

  • PDF

산성 및 유기성 가스의 동시제거를 위한 준건식 세정시스템의 적정 운전 조건 (Optimal Operation Condition of Spray Drying Sorber for Simultaneous Removal of Acidic and Organic Gaseous Pollutants)

  • 백경렬;구자공
    • 한국환경과학회지
    • /
    • 제10권1호
    • /
    • pp.59-64
    • /
    • 2001
  • The effect of major operating parameters in spray drying sorber(=SDS) for automatic control for the simultaneous removal of acidic and organic gaseous pollutants from solid waste incinerator was performed. The field experiment was carried out in pilot scale test for the quantification of major operating parameters of hydrophilic and the hydrophobic pollutants. The removal efficiencies of $SO_2$and HCI in the 5wt% slurry condition were being increased with the increase of the stoichiometric ration which is the molecular ratio of lime to the pollutant concentration, and with the decrease of inflow flue gas temperature in the pilot SDS reactor. The removal efficiency along the height of spray drying sorber was closely related to the temperature profile, and more than 90% of total removal efficiency was achieved in an absorption region. For the removal of acidic gas the optimum operating condition considering the economics and a stable operation is the 5wt% of slurry concentration, 1.2 of stoichiometric ratio and 25$0^{\circ}C$ of inflow flue gas temperature. For the organic gases of benzene and toluene the removal efficiencies were 20-60% which is much lower than that of acidic gas. The best removal efficiency was obtained at 1.5 of stoichiometric ratio and 25$0^{\circ}C$ of inflow flue gas temperature. The organic\`s removal efficiency along the height of spray drying sorber was quite different from that of acidic gas, that is, more than 60% of the total removal efficiency for benzene and 90% of the total removal for toluene were achieved in the dried adsorption region, which was formed at the lower or exit part of the reactor.

  • PDF

SPCP를 이용한 오염물질 ($SO_2$, NOx) 처리 특성 (The Characteristics of the Treatment of Pollutants ($SO_2$, NOx) Using Surface Discharge Induced Plasma Chemical Process)

  • 봉춘근;부문자
    • 한국대기환경학회지
    • /
    • 제14권4호
    • /
    • pp.333-342
    • /
    • 1998
  • Plasma process has great possibilities to remove SOx, NOx simultaneously with high treatment efficiency and is expected to be suitable for small or middle plants. It was accomplished to evaluate SO2, NOx control possibility and achieve basic data to control pollutants by use of Surface Discharge Induced Plasma Chemical Process (SPCP) in this study. O3 generation characteristics by discharge of a plate was proportional to O2 concentration and power consumption and inversely proportional to temperature and humidity, In case of dry air, NOx was highly generated by N2 and O2 in air during the plasma discharge process but it was decreased considerably as H2O was added. SO2 removal efficiency was very high, and removal rate was 170,350 mEA at 30,50 watt respectively in flue gas which is usually contain HIO. NOx removal efficiency was about 57% at 40 watt power consumption with 7.5% humidity. It is estimated that H2O has an important role in reaction mechanism with pollutants according to plasma discharge.

  • PDF

활성탄 사용에 따른 습식세정시설에서의 대기오염물질 제거효율 평가 (Removal Efficiencies Estimation of Air Pollutants at Wet Scrubber Using Activated Carbon)

  • 신찬기;권명희;전종주;신대윤
    • 환경위생공학
    • /
    • 제18권2호
    • /
    • pp.87-93
    • /
    • 2003
  • This study carried out to recommend adaptable technologies and countermeasures for performance improvement of Wet Scrubber(WS) in industrial waste incinerator. When not using the Activated Carbon(AC), the removal efficiency of dust and HCl is 73%, 92%. And particulate phase and gaseous phase dioxins removal efficiency was evaluated up to 31% and 12%. In this case, dioxins enrichment was not revealed in WS. When using the AC mixing with scrubbing water, the case of 1,000ppm, removal efficiency of particulate phase dioxins was about 51%, and gaseous phase dioxins was about 96%. The case of 2,000ppm, removal efficiency of particulate phase dioxins was about 55%, and gaseous phase dioxins was about 97%. And the case of 3,500ppm, the removal efficiency of particulate phase dioxins was about 35%, and gaseous phase dioxins was about 96% respectively. By this study, using the AC was more useful to remove the gaseous phase dioxins, and needed to use proper concentration of the AC, that in case of 3,500ppm, the particulate phase dioxins removal efficiency was more lower than other cases.

유해오염물질 처리를 위한 흡연부스의 설계 (Study of Smoking Booth Design for the Treatment of Hazardous Pollutants)

  • 권우택;권이승;이우식
    • 한국화재소방학회논문지
    • /
    • 제31권6호
    • /
    • pp.107-111
    • /
    • 2017
  • 본 연구는 흡연시 발생되는 각종 유해오염물질을 효과적으로 저감할 수 있는 친환경 흡연부스를 제작하고, 유해물질의 제거효율 및 효과를 평가하는 것이다. 유입구-HEPA필터-전기집진기(EP)-첨착활성탄-배출구 등의 탈취설비를 갖춘 친환경 자동 흡연부스를 설계 및 제작하여, 흡연연기에 의한 유해오염물질의 제거효율을 측정 및 평가하였다. 측정방법으로는 내부의 배경농도, 설비 가동 시 배출구 농도, 10분 후 흡연부스의 농도를 측정하고, 평가항목으로는 복합악취, 일산화탄소, 미세먼지($PM_1$, $PM_{2.5}$, $PM_{10}$), 총휘발성유기화합물(TVOCs)을 대상으로 하였다. 복합악취 제거효율은 흡연부스 내부에서는 95.37%, 방지설비통과 배출구에서는 97.38%로 우수하였다. 일산화탄소 제거효율은 내부에서는 94.25%, 배출구에서는 98.32%로 나타났다. 또 흡연부스 내부에서의 미세먼지 제거효율은 98.59%이며, 배출구에서는 98.85%로 나타나 미세먼지 제거효율은 매우 우수한 것으로 나타났다. TVOCs는 흡연부스 내부에서는 $26,000{\mu}g/m^3$에서 $5,203{\mu}g/m^3$로 감소하여 79.99%의 제거효율로 나타났고, 환풍기 가동 후 방지설비 배출구에서는 $5,019{\mu}g/m^3$로 측정되어 제거효율은 80.70%로 나타났다. 따라서 본 연구를 통하여 제작, 설계된 흡연부스는 향후 소규모 작업환경 내에서도 각종 유해오염물질들을 제거하는 용도로 적용할 수 있을 것으로 생각된다.

고도처리공정과 나노여과공정에서의 미량유해물질 제거 평가 (Assessment of Micro Organic Pollutants Removal Using Advanced Water Treatment Process and Nanofiltration Process)

  • 강준석;최양훈;권순범;유영범
    • 대한환경공학회지
    • /
    • 제36권8호
    • /
    • pp.579-587
    • /
    • 2014
  • 수계에서 검출되는 미량유해물질의 빈도와 종류가 다양해지고 있다. 따라서 정수처리시스템에서 고려되어야 할 부분으로 거론되고 있으며 제거공정과 처리효율에 대한 연구가 활발하게 진행되고 있다. 본 연구에서는 고도처리공정과 나노여과공정을 이용한 제거효율을 평가하였다. 나노여과공정의 경우 물질의 물리화학적 특성에 따라 제거율이 상이하게 나타났다. 물질의 분획분자량이 제거율이 가장 큰 영향을 미치는 것으로 확인되었다. 또한, 원수의 pH보다 높은 pKa 값을 갖거나 Log Kow 값이 2 이하인 물질의 제거효율이 감소되었다. 고도처리공정 중 산화공정에서는 대상물질의 분자량이 클수록 그리고 소수성을 띌수록 산화반응에 의한 제거효율이 감소되었다. 흡착공정에서는 산화되지 않은 대부분의 물질이 제거되었으며 $H_2O_2$에 의하여 산화가 더 잘 진행될수록 흡착반응이 향상되었다.