• Title/Summary/Keyword: Removal Efficiencies

검색결과 1,116건 처리시간 0.023초

Phosphorus Removal in Pilot Plant Using Biofilm Filter Process from Farm Wastewater

  • Shin, Sung-Euy;Choi, Du-Bok;Lee, Choon-Boem;Cha, Wol-Suk
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제11권4호
    • /
    • pp.325-331
    • /
    • 2006
  • Various environmental conditions affecting total phosphorus removal from farm wastewater in a biofilm filter process were investigated using loess balls and Chromobacterium LEE-38 at a pilot plant. When Chromobacterium LEE-38 was used, the removal efficiency of total phosphorous was approximately 10- or 5-fold higher than that of Acinetobacter CHA-2-14 or Acinetobacter CHA-4-5, respectively. When a loess ball of $11{\sim}14mm$ manufactured at a $960^{\circ}C$ calcining temperature was used, the removal efficiency of total phosphorous was 90.0%. When 70% of the volume fraction was used, the maximum efficiency of total phosphorus removal was 93.1%. Notably, when the initial pH was in the range of 6.0 to 8.0, the maximum removal efficiency of total phosphorus was obtained after 30 days. When the operating temperature was in the range of 30 to $55^{\circ}C$, the maximum removal efficiencies of total phosphorus, 95.6 to 94.6%, were obtained. On the other hand, at operating temperatures below $20^{\circ}C$ or above $40^{\circ}C$, the removal efficiency of total phosphorous decreased. Among the various processes, biofilm filter process A gave the highest removal efficiency of 96.4%. Pilot tests of total phosphorus removal using farm wastewater from the biofilm filter process A were carried out for 60 days under optimal conditions. When Acinetobacter sp. Lee-11 was used, the average removal efficiency in the p-adsorption area was only 32.5%, and the removal efficiencies of chemical oxygen demand (COD) and biological oxygen demand (BOD) were 56.7 and 62.5%, respectively. On the other hand, when Chromobacterium LEE-38 was used, the average removal efficiency was 95.1%, and the removal efficiencies of COD and BOD were 91.3 and 93.2%, respectively.

해수를 이용한 펄프공장 폐액의 화학적 처리에 관한 연구 (The study of chemical treatment of pulp mill bleaching waste liquor using sea water)

  • 정병곤;이헌모;윤종호
    • 환경위생공학
    • /
    • 제12권1호
    • /
    • pp.39-48
    • /
    • 1997
  • The study was conducted to know the possibility that the removal efficiency of organic and suspended solids(SS) could be increased by suppling of sea water and the optimum amount of sea water to be supplied treat bleaching waste water by lime coagulation settlement at pulp mill process. When the lime dosage was increased, the removal efficiency of COD and SS in the waste water was increased based on the removal efficiency of COD and SS. The lime dosage and removal efficiency was increased proportionally with the lime concentration of 4,000 mg/l, but the increase of removal efficiency was presented slightly above the 4,000mg/l. It was evaluated that the removal efficiencies of COD and SS could be increased and the requirement of lime dosage could be decreased by the sea water supplement. The removal efficiency of SS was most increased when the sea water supplement was 10% or more in the waste water. The removal efficiencies of COD was the best at 4% sea water excepting the dilution efficiency by sea water supplement.

  • PDF

Washout Removal Efficiencies of Major Air Pollutants by Precipitation

  • Kim, Dong-Sool;Lim, Deuk-Yong;Heo, Jeong-Sook
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제18권E2호
    • /
    • pp.97-106
    • /
    • 2002
  • The purpose of this study was to quantitatively estimate the washout removal efficiencies of criteria air pollutants such as SO$_2$, TSP, PM10, CO, NO$_2$, and O$_3$corresponding to the amounts and durations of precipitation. The removal patters by washout were studied with air pollutants data and the corresponding precipitation data in Seoul, Korea during the periods of 1990 to 1999. In addition, washout patterns were classified into four seasons and four time Bones, i.e., night, morning, afternoon, and evening. In this study, natures of air pollutants by sequential precipitation were also intensively studied by examining the linear relationships between removal efficiencies and the amounts and durations of precipitation for each pollutant. The results of this study showed that SO$_2$, TSP, and O$_3$were rapidly removed by initial precipitation; however, NO$_2$was slowly removed 2-hour after precipitation. Both CO and PM10 were weakly removed by washout and their removal patters showed to be irregular.

저온 플라즈마와 광촉매에 의한 NO/SO2 제거 (Removal of NO/SO2 by the low temperature plasmas and photocatalysts)

  • 김동주;김교선
    • 산업기술연구
    • /
    • 제26권A호
    • /
    • pp.181-188
    • /
    • 2006
  • In this study, we analyzed the effects of several process variables on the removal efficiencies of NO and $SO_2$ by the dielectric barrier discharge process combined with photocatalysts. The $TiO_2$ photocatalysts were coated onto the spherical-shaped glass beads as dielectric materials by the dip-coating method to analyze the effects of photodegradation reaction on the NO and $SO_2$ removal. As the voltage applied to the plasma reactor increases, or as the pulse frequency of applied voltage increases, the NO and $SO_2$ removal efficiencies increase. Also as the residence time increases, or as the initial concentration of NO decreases, the NO and $SO_2$ removal efficiencies increase. The higher the amount of $TiO_2$ particles coated onto the glass bead is, the larger the surface area of $TiO_2$ particles for the photodegradation reaction is and the NO and $SO_2$ are removed more quickly by the faster photodegradation reactions.

  • PDF

생물반응기와 광촉매반응기 시스템을 이용한 염료의 색도 제거

  • 윤종태;신민석;임동준
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2003년도 생물공학의 동향(XIII)
    • /
    • pp.463-467
    • /
    • 2003
  • Fundamental experiments were carried out about color removal efficiency of dyeing wastewater using a $bioreactor-TiO_2/UV$ reactor system. Color removal efficiencies of the Reactive Black 5 in the system were found to bo more than 80% in changes of dilution rate 0.04 to $0.08hr^{-1}$. In this research, a new color removal system of dying wastewater will be proposed after more investigation of decolorization efficiencies about different dyes and condition.

  • PDF

질소원 및 pH 조절빈도에 따른 Chlorella vulgaris의 성장특성 및 하수고도처리능 평가 (Growth and N, P removal efficiency of Chlorella vulgaris according to the nitrogen sources and pH condition)

  • 한수현;김선진;김태형;조기주;이윤희;황선진
    • 상하수도학회지
    • /
    • 제26권6호
    • /
    • pp.833-840
    • /
    • 2012
  • This study aimed to investigate growth rate and nutrient removal efficiency of Chlorella vulgaris according to nitrogen sources and frequency of pH adjustment. Nitrogen and phosphorus removal efficiencies were evaluated in the three different conditions using $NO_3{^-}$, $NH_4{^+}$ as a sole nitrogen source and mixed condition. Initial nutrient concentrations in artificial wastewater were 30 mg-N/L and 3 mg-P/L similar to secondary wastewater effluent. When nitrogen source was $NO_3{^-}$, there was no inhibition on the growth of C. vulgaris with adjusting pH every 24 hr while growth inhibition occurred with $NH_4{^+}$ caused by pH drop. N, P removal efficiencies were no significant depending on the nitrogen sources. As pH was adjusted to 7 by pH-stat, growth rate and nutrient removal efficiencies were increased compared to adjusting pH every 24 hr, however, growth rate and nutrient removal efficiencies were no significant depending on the nitrogen sources.

식생이 적용된 비점오염 저감시설의 강우 특성에 따른 효율 분석 (Analysis of Non-point Pollution Source Removal Efficiencies according to Rainfall Characteristics in Low Impact Development Facilities with Vegetation)

  • 구수환;임지열;어성욱;길경익
    • 한국물환경학회지
    • /
    • 제33권3호
    • /
    • pp.247-255
    • /
    • 2017
  • This research was conducted to analyze removal efficiencies of non-point pollution source (NPS) in low impact development (LID) facilities with vegetation. In this research, removal efficiencies of NPS were calculated using rainfall monitoring data for 5 years in grassed swale (GS) and vegetative filter strip (VFS). TSS was greater than other pollutants, and it ranged 11.9 ~ 351.7 mg/L in GS and 12.8 ~ 350.7 mg/L in VFS. Outflow EMCs were reduced than inflow EMCs, overall removal efficiencies of NPS were 67 ~ 86% in GS and 63 ~ 91% in VFS. 50 % reduction efficiency of rainfall runoff was observed between inflow and outflow in each LID facility. TSS removal efficiency in GS and VFS was correlated with rainfall characteristics. The rainfall for TSS removal efficiency over 50% was determined about 31 mm, 34 mm and average rainfall intensity was 3.0 mm/hr, 3.9 mm/hr in GS and VFS. Therefore, GS and VFS were regarded effective LID facilities as removal of pollutants and rainfall runoff. Also, this research result can be used as an important data for management of NPS.

밤나무 재활용에 의한 구리 이온의 생물흡착 (Biosorption of Copper Ions by Recycling of Castanea crenata)

  • 최석순
    • 공업화학
    • /
    • 제25권3호
    • /
    • pp.307-311
    • /
    • 2014
  • 본 연구에서는 4종류의 목재 폐기물(밤나무, 소나무, 낙엽송, 아카시아) 중에서 구리 이온 제거 능력이 뛰어난 생물흡착제로서 밤나무를 도출하였으며, 또한, 이 밤나무를 이용하여 수중에 함유된 5, 10, 20, 40 mg/L 구리 이온의 제거 효율에 대하여 고찰하였다. 5 mg/L 구리 이온 제거를 위하여, $43{\sim}63{\mu}m$ 입자 크기의 밤나무 사용이 가장 효과적임을 알 수 있었다. 밤나무 주입 농도를 증가하였을 때, 구리 제거효율이 향상되었다. 또한, 0.8 g/100 mL 밤나무가 30 min 동안 사용되었을 때, 20, 40 mg/L 구리 이온 제거효율은 각각 99, 85% 제거효율을 나타내었다. 그리고 50 mg/L 구리 이온의 제거 능력을 향상시키기 위하여, 밤나무에 1 M 아세트산나트뮴의 화학적 처리가 필요함을 알 수 있었다. 한편, 개질된 밤나무를 재활용하기 위하여 최적의 탈착제로서 93% 구리 탈착 효율을 나타낸 1 M 염산을 선정하였다. 따라서 이러한 실험 결과들은 경제적이고 실용적인 공학 자료로서 구리 제거 공정 개발에 활용될 수 있을 것이다.

저온 플라즈마 공정에 의한 효율적인 탈황 및 탈질 (Efficient Desulfurization and Denitrification by Low Temperature Plasma Process)

  • 김성민;김동주;김교선
    • Korean Chemical Engineering Research
    • /
    • 제43권1호
    • /
    • pp.129-135
    • /
    • 2005
  • 본 연구에서는 펄스 코로나 방전 공정에 의해 $SO_2$$SO_2/NO$의 제거효율을 분석하였으며, 여러 공정변수가 제거효율에 끼치는 영향을 체계적으로 조사하였다. 공정변수로서 인가전압, 펄스 주파수, 체류시간, 반응물의 초기 농도(NO, $SO_2$, $NH_3$, $H_2O$, and $O_2$)의 영향을 분석하였다. 인가되는 전압, 펄스 주파수 또는 체류시간이 증가함에 따라 또는 $O_2$$H_2O$가 첨가됨에 따라 $SO_2$의 제거효율과 $SO_2/NO$의 동시 제거효율은 증가하였다. 또한, $NH_3$의 초기 농도가 증가할수록 $SO_2/NO$의 제거효율은 증가하였다. 이 실험적인 결과들은 $NO_x$$SO_x$를 제거하기 위한 펄스 코로나 방전 공정 장치 설계의 기초 자료로 사용될 수 있다.

우엉발효추출물을 이용한 생활악취물질 제거효율 조사 (Removal Efficiency of odor substance Using Arctium Lappa Root extract)

  • 이동섭;박진식
    • 한국환경과학회지
    • /
    • 제23권11호
    • /
    • pp.1953-1961
    • /
    • 2014
  • Increasing public concerns over odors and air regulations necessitates the remediation of a wide range of odor substances for industrial and indoor purpose. Currently, the wet scrubbing technique by neutralization using oils is being used to treat odor substances such as Ammonia($NH_3$), Methyl Mercaptan($CH_3SH$), Hydrogen Sulfide($H_2S$), Methylamine($CH_3NH_2$), Acetaldehyde($CH_3CHO$). The chemical analysis is performed to analyze the composition of an Arctium Lappa Root extract by VOC analyzer(Phocheck 5000Ex, ION SCIENCE co.) The objectives of the this study are to clarify the possibility of the neutralization of odors sprayed in the fixed bed and determine the removal efficiencies for different input odor concentrations. It is found that Ammonia($NH_3$), Methyl Mercaptan($CH_3SH$), Hydrogen Sulfide($H_2S$), Methylamine($CH_3NH_2$), Acetaldehyde($CH_3CHO$) are significantly removed and their removal efficiencies are higher than 98%. The kitchen detergent with Arctium Lappa Root extract showed excellent removal efficiencies of odor substances and high possibility for the development of kitchen detergent with odor removal.