• Title/Summary/Keyword: Removal Amount

Search Result 1,457, Processing Time 0.027 seconds

APPLICATIONS OF SERICITE IN WASTEWATER TREATMENT : REMOVAL OF Cu(II) AND Pb(II) FROM AQUEOUS SOLUTIONS

  • Tiwari, Diwakar;Kim, Hyoung-Uk;Lee, Seung-Mok
    • Environmental Engineering Research
    • /
    • v.11 no.6
    • /
    • pp.303-310
    • /
    • 2006
  • The aim of this study is to assess the applicability of sericite in wastewater treatment particularly the removal of two important heavy metal toxic ions viz., Cu(II) and Pb(II) from aqueous solutions. The batch type experiments showed that sericite is found to be one of useful natural sorbent for the removal of these two cations from aqueous solutions and it is also to be observed that with the increase in sorptive concentration amount of metal uptake increases and the concentration dependence data obtained are fitted well for the Langmuir adsorption isotherm rather than Freundlich adsorption model. Further, the Langmuir monolayer adsorption capacity is found to be $1.674\;mg\;g^{-1}$ for Cu(II) and $4.697\;mg\;g^{-1}$ for Pb(II). Kinetic studies enabled, an apparent equilibria can be achieved between soild/solution interface within ca 10 mins for Cu(II) and ca 90 mins for Pb(II). Moreover, the removal behavior of sericite for these two metal ions is greatly influenced by solution pH.

THE EFFECT OF GUTTA-PERCHA REMOVAL USING NICKEL-TITANIUM ROTARY INSTRUMENTS (엔진 구동형 니켈 티타늄 파일을 이용한 거터퍼쳐의 제거 효과)

  • Jeon, Jeong-Hun;Min, Jeong-Beom;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.3
    • /
    • pp.212-218
    • /
    • 2004
  • The purpose of this study was to quantify the amount of remaining gutta-percha/sealer on the walls of root canals when three types of nickel-titanium rotary instruments (Profile. ProTaper and $K^3$) and a hand instrument(Hedstrom file) used to remove these materials. The results of this study were as follows: 1. In the total time for gutta-percha removal. Profile group was the fastest and followed by $K^3$, Protaper, Hedstrom file group. 2. In case of the evaluation of the volume of remained gutta-percha from radiograph. $K^3$ group got the highest score and followed by Protaper. Hedstrom file. Profile group in the apical 1/3. 3. In case of the evaluation of the volume of gutta-percha remained from stereomicroscope, $K^3$ group got the highest score and followed by Protaper. Hedstrom file. Profile group in the apical 1/3. These results showed that instrumentation using nickel-titanium rotary instrument groups was faster than that using hand instrument group. The effect of gutta-percha removal using Profile group was better than that using Protaper and $K^3$ group in the nickel-titanium rotary instrument groups.

Effect of ammonium nitrogen in anaerobic biofilter using live-stock-wastewater (축산폐수의 혐기성 고정법에 있어서 암모니아성 질소의 영향)

  • Eom, Tae-Kyu;Lim, Jung-Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.4
    • /
    • pp.43-53
    • /
    • 1997
  • In this research, the synthetic livestock wastewater was prepared to study the characteristics of organic matter removal, the change of VFA production, and the amount of gas production with respect to the change of ammonium nitrogen concentration in the waste using anaerobic fixed bed process, which is an anaerobic biofilm process. The HRT and operation temperature were 1 day and $35{\pm}1^{\circ}C$, respectively. Also, the characteristics of organic matter removal and the inhibitory effect on microorganism in the anaerobic process were studied on the organic loading and ammonium nitrogen concentration. The results obtained were as follows: For COD loading of $10kg/m^3$-day and five levels of ammonium nitrogen concentration ranging from 1,000 to 5,000 mg/L, organic removal efficiencies were about 81, 74, 67, 58, and 51%, and gas productions were 3,860, 3,520, 3,240, 3,020, and 2,790 ml/l-day, respectively. Average methane contents in the gas produced on COD loading of $10kg/m^3$-day was about 76%. Throughout the whole period of experiment, remaining VFA (as COD base) in the effluent was over 90% of remaining COD. This result indicated the inhibitory effect of high concentration of ammonium nitrogen through the facts that accumulated VFA was almost COD and organic removal efficiency decreased also with the increase of ammonium nitrogen. Especially, that implys which high concentration of ammonium nitrogen not only inhibits methane forming bacteria, but also acid forming bacteria.

  • PDF

Soil Column Experiment to Evaluate Removal of Nutrients in Stormwater Runoff by Soil of Riparian Protection Zone (토양칼럼을 이용한 초기우수 중 염양염류의 수변녹지 토양에서의 제거도 평가)

  • Yoon, Seok-Pyo;Choi, Ji-Yong
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.3
    • /
    • pp.231-235
    • /
    • 2004
  • To investigate removal effects of nutrients in stormwater runoff by soil of riparian protection zone, soil column experiment was conducted for 20 months. Artificial stormwater runoff containing phosphate and nitrate was applied on the surface of soil column twice a week, and phosphate and nitrate concentrations were measured from the leached water. Soil of riparian protection zone reduced the released amount of infiltrated water to the surrounding water. After infiltration of 1m depth of soil column, average removal rates of phosphate and nitrate were 97.7 % and 74.7 %, respectively. As main mechanisms of phosphate are adsorption to soil particle and utilization by plants, periodical replacement of soil and harvesting of plant at the end of growing season are required. For the removal of nutrients in stormwater runoff by the soil layer, soil of riparian protection zone has higher hydraulic conductivity to infiltrate stormwater. Sandy soil having hydraulic conductivity of about $1{\times}10^{-2}cm/s$ range might be appropriate for this purpose.

A study on the fault detection efficiency of software (소프트웨어의 결함 검출 효과에 관한 연구)

  • Kim, Sun-Il;Che, Gyu-Shik;Jo, In-June
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.4
    • /
    • pp.737-743
    • /
    • 2008
  • I compare my parameter estimation methodoloay with existing method, considering both of testing effort and fault detecting rate simultaneously in software reliability modeling. Generally speaking, fault detection/removal mechanism depends on how apply previous fault detection/removal and testing effort of S/W. The fault removal efficiency makes large influence to the reliability growth, testing and removal cost in developing stage S/W. This is very useful measure during all the developing stages and much helpful for the developer to estimate debugging efficiency, and furthermore, to anticipate additional working amount.

Effects of Temperature on Removal Rate in Cu CMP (Cu CMP에서 온도가 재료 제거율에 미치는 영향)

  • Park, In-Ho;Lee, Da-Sol;Jeong, Seon-ho;Jeong, Hae-do
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.6
    • /
    • pp.91-97
    • /
    • 2018
  • Chemical mechanical polishing(CMP) realizes a surface planarity through combined mechanical and chemical means. In CMP process, Preston equation is known as one of the most general approximation of the removal rate. Effects of pressure and relative speed on the mechanical property of Cu CMP has been investigated. On the other hand, The amount of abrasion also increased with changes in pressure and speed, resulting in a proportional increase of temperature during CMP. Especially this temperature is an important factor to change chemical reaction in a Cu CMP. However, when the slurry temperature became higher than $70^{\circ}C$, the removal rate went lower due to abrasives aggregation and scratching occurred on the Cu film. Therefore, it was found that the slurry temperature should not exceed $70^{\circ}C$ during Cu CMP. Finally, authors could increase the pressure, speed and slurry temperature up to a ceratin level to improve the removal rate without surface defects.

The Study on Burr Removal Rate Along the Cutting Radial Distance in U-type Flow Channel (절삭 반경에 따른 U-type 유로 형상의 버 제거율에 관한 연구)

  • Son, Chul-Bae;Lee, Jung-Hee;Kwak, Jae-Seob
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.7
    • /
    • pp.8-13
    • /
    • 2019
  • As increasing demand for precise machining in advanced disciplines, especially in semi-conductor, aeronautical and automotive industries, the magnetic abrasive deburring(MAD) which is able to eliminate micro-sized burr on complex surface in less time has drawn the attention in the last decades. However, the performance of MAD is subject to shape and size of a tool. Therefore, this study aim to identify deburring behavior of MAD in U-type flow channel by measuring the length rate of burr removal in radial distance of the cylindrical tool under four process factors. In order to evaluate the deburring effect of MAD on the surface, finishing regions are divided based on center of the circular cutting tool. As a results, it was defined that the amount of burr removal in a downward direction moving toward flow channel from the top surface was higher than upward direction. This is because the magnetic abrasives were detached from magnetic lines of force due to geometrical shape.

Development of Copper and Copper Oxide Removal Technology Using Supercritical CO2 and Hexane for Silicon Solar Cell Recycling (실리콘 태양전지 재자원화를 위한 초임계 CO2 및 헥산을 이용한 구리 및 산화구리 제거기술 개발)

  • Lee, Hyo Seok;Cho, Jae Yu;Heo, Jaeyeong
    • Current Photovoltaic Research
    • /
    • v.7 no.1
    • /
    • pp.21-27
    • /
    • 2019
  • Lifetime of Si photovoltaics modules are about 25 years and a large amount of waste modules are expected to be discharged in the near future. Therefore, the extraction and collection of valuable metals out of discharged Si modules will be one of the important technologies. In this study, we demonstrated that supercritical $CO_2$ extraction method can be effectively used to remove Cu, one of the abundant elements in the module, as well as its oxide form, $Cu_2O$. Especially, we proved that the addition of hexane as co-solvent is effective for the removal of both materials. The optimal ratio of $CO_2$ and hexane was 4:1 at a fixed temperature and pressure of $250^{\circ}C$ and 250 bar, respectively. In addition, it was proven that the removal of $Cu_2O$ was preceded via reduction of $Cu_2O$ to Cu.

Evaluation of Ammonia Removal Mechanisms and Efficiencies Through Batch Experiments (배치 실험을 이용한 암모니아 제거 기작 및 효율 평가)

  • Jang, Jieun;Kang, Jiyoung;Kim, Hye Won;Shin, Kyu Jin;Jeen, Sung-Wook
    • Journal of Soil and Groundwater Environment
    • /
    • v.27 no.6
    • /
    • pp.37-46
    • /
    • 2022
  • As the amount of livestock wastewater increases, ammonia contamination in surface water and groundwater is also increasing, and its treatment is urgently needed. In this study, indigenous soil bacteria was utilized for ammonia removal in artificial wastewater and associated removal mechanisms and efficiencies were evaluated. Two batch reactors were configurated to contain natural soil and artificial wastewater at 1:10 mass ratio, and incubated for 84 and 168 hours, respectively. The results showed that ammonia was completely removed within 48 and 72 hours in the first and second reactors, respectively. There were no significant changes in ammonia concentrations in the control groups without soil. Nitrate was formed in the reactors, indicating that the main removal mechanism of ammonia was nitrification by nitrifying bacteria. Nitrate was further converted to nitrogen gas by denitrification in the anaerobic environment, which was caused by consumption of oxygen during the nitrification process.

Adsorptive Removal Properties of Heavy Metal Ions By Soils from the Upper Banbyun Stream (반변천 상류 주변 토양의 중금속 이온 흡착제거 특성)

  • Kim, Younjung;Hwang, Haeyeon;Kim, Yunhoi;Ryu, Sanghoon;Baek, Seungcheol;Seo, Eulwon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.2
    • /
    • pp.5-9
    • /
    • 2007
  • This study carried out to investigate the removal capacity of heavy metals such as Cu (II), Zn (II) and Cd (II) dissolved in aqueous solution in the soils collected from Hyeon-Dong (HD), San-seong (SS), Keum-chon (KC) and Keum-Hac (KH) located in the upper Banbyun stream. The pH of all the soils was weak alkali such as 8.8 9.2. According to the analysis of chemical composition of the soils, the amount of $SiO_2$, $AlO_2$ and CaO were similar in all tested soils. However, the amount of $K_2O$, $FeO_3$ and MgO were different from each soil. The XRD measurement with these soils showed that quartz and feldspar were presented in all tested soils, and the distribution of kaoline, illite, montmorillonite, vermiculite and calcite were different from each soil. The results of the removal capacity of heavy metals indicated that all the soils had more than 98% of the removal efficiency of Cu (II), Zn (II) and Cd (II), and among the heavy metals, Cu (II) was removed the most effectively. These results suggested that the soils collected from the upper Banbyun stream have the high removal capacity of heavy metals, and these soils could be used for the banking a river around the abandoned mine area, containing the higher concentrations of heavy metals than the usual stream.

  • PDF