• Title/Summary/Keyword: Remote-monitoring

Search Result 2,201, Processing Time 0.028 seconds

Development of Remote Monitoring System for groundwater purifier apparatus for community wells (마을 공동 우물용 지하수 정수 장치의 원격 모니터링 시스템 개발)

  • Kim, Dong-Jin;park, Sang-heup;Lee, Hong-Sup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.224-231
    • /
    • 2019
  • Recently, the pollution of groundwater has become serious. In particular, the contamination of groundwater near livestock farms is becoming increasingly severe and it is difficult to drink with drinking water. In this paper, a groundwater purifier apparatus that can be installed in a community well was designed. The designed groundwater purifier apparatus enables a RO membrane filter and UV sterilization to remove pollutants, such as heavy metals, bacteria, and organic compounds. In addition, electrical conductivity, pressure, and flow sensors were added for remote monitoring. Remote monitoring of the system can determine the level of fouling and contamination of RO membrane filters through pressure and flow sensor data, and can record changes in the contamination and condition of groundwater through the electrical conductivity of the feed water. The designed groundwater purifier apparatus was installed at a farmhouse and remote monitoring. The result after 15 days of operating a groundwater purifier apparatus and analyzing the monitoring data revealed an average permeate water flow rate of 2.67L/min and an average water pressure of 7.09kgf/㎠, indicating that the RO Membrane filtered without fouling and clogging. The average electrical conductivity was 796.6 S/㎠ of the feed water and 55.6 S/㎠ of permeate water, which is similar to that of general tap water. Through this, it was confirmed that no pollutant occurred in the surroundings. Therefore, the designed groundwater purifier apparatus can confirm the replacement time of the RO membrane filter in advance through remote monitoring, and check the pollution state of the groundwater.

Long term monitoring of a cable stayed bridge using DuraMote

  • Torbol, Marco;Kim, Sehwan;Shinozuka, Masanobu
    • Smart Structures and Systems
    • /
    • v.11 no.5
    • /
    • pp.453-476
    • /
    • 2013
  • DuraMote is a remote sensing system developed for the "NIST TIP project: next generation SCADA for prevention and mitigation of water system infrastructure disaster". It is designed for supervisory control and data acquisition (SCADA) of ruptures in water pipes. Micro-electro mechanical (MEMS) accelerometers, which record the vibration of the pipe wall, are used detect the ruptures. However, the performance of Duramote cannot be verified directly on a water distribution system because it lacks an acceptable recordable level of ambient vibration. Instead, a long-span cable-stayed bridge is an ideal test-bed to validate the accuracy, the reliability, and the robustness of DuraMote because the bridge has an acceptable level of ambient vibration. The acceleration data recorded on the bridge were used to identify the modal properties of the structure and to verify the performance of DuraMote. During the test period, the bridge was subjected to heavy rain, wind, and a typhoon but the system demonstrates its robustness and durability.

A Development of Web-based Remote monitoring and control system using Java (Java를 이용한 웹 기반 원격 감시제어시스템 개발)

  • Park, Jong-Jin
    • Journal of the Korea Computer Industry Society
    • /
    • v.8 no.1
    • /
    • pp.41-48
    • /
    • 2007
  • In this paper, a example of a development of web-based remote monitoring and control system using Java technology on TCP/IP is proposed. We implemented Client/Server socket programs using Java Socket class, and applied those to a greenhouse made from LEGO blocks and made web-based greenhouse remote monitoring and control system. Implemented System transferred states of greenhouse to client programs, and control signals from client program were transferred to Server. Greenhouse model was controlled well by the system.

  • PDF

Remote Patient Monitoring Service through World-Wide Web (Web을 통한 원격 환자 모니터링 서비스)

  • Lee, H.S.;Park, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.188-191
    • /
    • 1997
  • In this paper, we present a real-time remote patient monitoring service through world-wide web, which allows the medical doctor to monitor his patients in remote sites using popular web browsers. The real-time service consists of two services: Patient Locator Service (PLS) and Vital Sign Monitoring Service (VSMS). The PLS provides the information of patients currently being monitored. The VSMS allows the user to observe a stream of vital sign data of a specific patient. The vital sign data include ECG, respiration, temperature, $SPO_2$, invasive blood pressure and non-invasive blood pressure.

  • PDF

A case study of remote wireless monitoring system for stray current due to subway system (지하철 누설전류 무선 원격 감시시스템 적용 사례)

  • Bae, Jeong-Hyo;Ha, Yoon-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1817-1818
    • /
    • 2006
  • In present, most of metallic structures (gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway in Seoul and Pusan.In this case, subway system make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential, amplitude of stray current, point of source of stray current and so on. In this paper, results of development about Wireless Remote Monitoring and Control System on Underground Pipeline in Stray Current Conditions are presented. And also field test data should be reporting.

  • PDF

Design and Implementation of DCS Terminal Remote Monitoring Board using Wire and Wireless Communication (유무선 통신을 이용한 DCS 터미널 원격 감시 보드 설계 및 구현)

  • KPark, Hae-Dong;Kang, Jeon-Wook;Kim, Jae-Hwan;Lee, Se-Hoon
    • KSCI Review
    • /
    • v.14 no.2
    • /
    • pp.117-122
    • /
    • 2006
  • In this paper, we designed and implemented the DCS(Distributed Control System) terminal remote monitoring board for build total unified management system based wireless communication on automatic control system fields. Also, it tested and evaluated for check an usability and performance. The board monitored relay and fuse status at power management room real-time. Therefore, we expected economic effects extend relay life-time that pre-detected errors and prevented relay fault.

  • PDF

Design of a CDMA-Based Real-time Remote Monitoring System (CDMA 기반 실시간 원격 감시 시스템의 설계)

  • Woo Jong-Woon;Jung Chun-Suk;Lee Bong-Geol
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.1 s.307
    • /
    • pp.7-12
    • /
    • 2006
  • In this paper we proposed a real-time remote monitoring system for interoperability between local area and wide area for wireless data communication. In local area, we used a miniaturized low-power wireless module and in wide area used CDMA Cellular System's Packet Data Service. The measurement results can be spread via Internet access in real-time

A Study on Development of Internet Based Power Management System Using a Microprocessor (마이크로프로세서를 이용한 인터넷기반 전력관리시스템 개발에 관한 연구)

  • 천행춘
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.5
    • /
    • pp.746-753
    • /
    • 2004
  • In this paper, the Power Management System(PMS) which based on a decision making system according to power strategy is proposed and implemented. PMS is designed to have functions of power monitoring. controlling, synchronizing load sharing and monitoring of driving engine, etc. PMS consists of the internet communication system(ICS). Remote Management System(RMS) and Sensor Driver System (SDS) ICS transmits the monitoring and supervisory data via Internet to Remote Management System(RMS) in real-time SDS detects various power system data on local generator and utility via I/O interface system. I/O interface system receives various status data and outputs control signals. Implemented PMS is tested with dummy signal to verify proposed functions and shows good results. For future study implemented PMS will be tested under real load condition to merchandize.

Development of n Remote Monitoring System for TFT-LCD Panel Test Automation (TFT-LCD 채널검사 자동화를 위한 원격 모니터링 시스템 개발)

  • Park, Hyoung-Keun;Lee, Seung-Dae;Kim, Sun-Youb
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.3
    • /
    • pp.483-487
    • /
    • 2007
  • In this study, we develop a new remote monitoring system for TFT-LCD panel test automation. Having to realtime monitor of Ti-Con board, this system needs to discrimination whether breakdown or not that is able to transmit processing data for engineer at long distance place using TCP/IP. The result of the development, that can be fast opposition to the breakdown and the multiple processing

  • PDF