• Title/Summary/Keyword: Remote management

Search Result 1,617, Processing Time 0.028 seconds

Remote Sensing and Geo-spatial Information Utilization for Managing Disaster in Korean Peninsula (한반도 재난 관리를 위한 원격탐사와 공간정보 활용기술)

  • Kim, Seongsam;Nho, Hyunju;Lee, Junwoo;Kim, Jinyoung;Kim, Jinsoo
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.5_4
    • /
    • pp.1139-1151
    • /
    • 2020
  • The National Disaster Management Research Institute(NDMI) has been developed technologies for disaster management applicability as well as disaster monitoring and damage analysis based on various earth observation platforms such as satellites, drones, and disaster field investigation vehicles. In this special issue, recent research results related to the disaster site investigation, satellite-based disaster management technology, and disaster information analysis using GIS conducted by NDMI are described in detail. Based on such achievements in the research of earth observation, we will continue to make efforts to improve the integrated national disaster investigation, analysis, and monitoring technology by connecting with the existing geo-spatial information service technology and various information collected at the disaster site.

A study on the street security light management system using Zigbee network (지그비 통신망을 이용한 보안등 관제 시스템에 관한 연구)

  • Jeon, Joong Sung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.430-436
    • /
    • 2014
  • This paper relates to the study about the street security light management system. The purpose of the wireless remote management system is to manage street security lights efficiently. The system is composed of three components like light controller, CDMA gateway and web based remote management server. The zigbee solution is adopted to make local wireless network between street security lights. The CDMA network is used for the wireless communication between street security light controller and the remote control center. The gateway to interconnect zigbee network and CDMA was designed with low power 32 bits Cortex M3 micro-controller. For the data communication between the management server and the gateway, SMS and socket based TCP streaming is used. The management server sends SMS to the gateway to deliver light control and management requests, and the gateway replies with the light controllers report via TCP streaming. By using both SMS and TCP streaming communication, it was verified that simple cost effective management is possible for street security lights. We tried real test for 95 street security lights in real environment during two months and analyzed the practical possibility for mass supply.

Implementation and application of remote control system using LACC(Local Area Control Center) (LACC를 이용한 원격제어 시스템 구현 및 적용)

  • Park Tae-Jin;Jang Myung-Kee;Chung Seung-Ryul
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.43 no.4 s.310
    • /
    • pp.15-22
    • /
    • 2006
  • Nowadays, there is called energy saving, that it is accomplished with a lot study and application development as according to demand of all around world. It is using to network device of wire or wireless such as internet, lan, plc, and zigbee and that we should be accomplished to study about method that spending a little cost to fatal error in control system that be expected of frequent occurrence on network, and that have method to do construction a little bit tried out. Also, in that such a embedded system with network function case, there is important thing that it is remote management to network node and control methods to trust because firmware upgrade have the advantage of more than the other device. In this paper, we have verified through a result of experiment for efficient remote management and control method as previously stated in this paper, that it is area of the PLC for sensor node and doing management to relay, and implementation of the LACC which is core part of the ESS, and in order to get a result to trust from doing analysis of capacity and test.

Subsurface Antenna for Remote Management of Underground Facility (지하 매설물 원격 관리를 위한 지표면 매입형 안테나)

  • Park, Dong-Kook;Cho, Ik-Hyun;Seo, Hong-Eun;Yun, Na-Ra;Hong, Che-Sup
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.10
    • /
    • pp.1150-1156
    • /
    • 2007
  • In this paper, two novel subsurface antennas for remote management of underground facilities using PCS and cellular wireless network are proposed. The proposed subsurface antenna is a dual band circular patch which is inserted and molded for the protection of the antenna into a metal such as a manhole cover. The antenna is designed considering the resonant frequency shift of the antenna due to the insertion and molding. The measured return loss and receiving power of the fabricated antenna comparison with a dipole shows that two proposed subsurface antenna can be used for remote management of underground facilities using PCS and cellular systems.

Challenges in Application of Remote Sensing Techniques for Estimating Forest Carbon Stock (원격탐사 기술의 산림탄소 축적량 추정적용에 있어서의 도전)

  • Park, Joowon
    • Current Research on Agriculture and Life Sciences
    • /
    • v.31 no.2
    • /
    • pp.113-123
    • /
    • 2013
  • The carbon-offset mechanism based on forest management has been recognized as a meaningful tool to sequestrate carbons already existing in the atmosphere. Thus, with an emphasis on the forest-originated carbon-offset mechanism, the accurate measurement of the carbon stock in forests has become important, as carbon credits should be issued proportionally with forest carbon stocks. Various remote sensing techniques have already been developed for measuring forest carbon stocks. Yet, despite the efficiency of remote sensing techniques, the final accuracy of their carbon stock estimations is disputable. Therefore, minimizing the uncertainty embedded in the application of remote sensing techniques is important to prevent questions over the carbon stock evaluation for issuing carbon credits. Accordingly, this study reviews the overall procedures of carbon stock evaluation-related remote sensing techniques and identifies the problematic technical issues when measuring the carbon stock. The procedures are sub-divided into four stages: the characteristics of the remote sensing sensor, data preparation, data analysis, and evaluation. Depending on the choice of technique, there are many disputable issues in each stage, resulting in quite different results for the final carbon stock evaluation. Thus, the establishment of detailed standards for each stageis urgently needed. From a policy-making perspective, the top priority should be given to establishinga standard sampling technique and enhancing the statistical analysis tools.

  • PDF

Understanding and Development of Software-based Open Architecture Controller (소프트웨어 기반의 개방형 제어기에 대한 이해와 개발)

  • Yun Won-Soo;Kim Chan-Bong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.4
    • /
    • pp.136-143
    • /
    • 2005
  • Open architecture controller (OAC) is well known technology in factory automation. To better understand the requirements of OAC, authors have discussed the OAC related topics with a number of control experts who represents different segments of the machining industry. There is no common concept that is accepted or used, however, the common ideas for OAC is the control system that is hardware independent, interchangeable, and easily scalable. This paper presents summary of the understaning and requirements of OAC. Based on the requirements of OAC, authors developed the software based PC-CNC. The main focus of the PC-CNC was on the user customization capability and open interface between control networks in manufacturing system. This paper introduces the developed PC-CNC briefly. In addition to introduction of the PC-CNC, to fill the gap between end users and vendors of OAC, this paper presents two applications using OAC. One is a remote monitoring system. The OPC (Ole for Process Control) standard interface was used to monitor the status of open architecture CNC across network. The other is the remote production management module for machine tools using standard database interface.

Design of a Remote Meter Reading module considering battery life time (배터리 수명을 고려한 원격검침 모듈 설계)

  • Jeong, Won-Chang;Gu, Myeong-Mo;Jang, Sung-Joo;Kim, Sang-Bok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.4
    • /
    • pp.45-50
    • /
    • 2008
  • Meter reading modules, which read the meter and transmit the data to water management offices, can't use the electric wires for their power supply. Therefore, batteries have to be used for meter reading modules and that cause maintenance problems like periodic batteries replacement. To save the maintenance cost, a wireless transmitting solution with less power consumption is required. In This paper, we designed a remote meter reading module, which reads meter automatically with less power consumption of battery by effective management of power source and transmits the reading data using RF.

  • PDF

Assessment of Earth Remote Sensing Microsatellite Power Subsystem Capability during Detumbling and Nominal Modes

  • Zahran M.;Okasha M.;Ivanova Galina A.
    • Journal of Power Electronics
    • /
    • v.6 no.1
    • /
    • pp.18-28
    • /
    • 2006
  • The Electric Power Subsystem (EPS) is one of the most critical systems on any satellite because nearly every subsystem requires power. This makes the choice of power systems the most important task facing satellite designers. The main purpose of the Satellite EPS is to provide continuous, regulated and conditioned power to all the satellite subsystems. It has to withstand radiation, thermal cycling and vacuums in hostile space environments, as well as subsystem degradation over time. The EPS power characteristics are determined by both the parameters of the system itself and by the satellite orbit. After satellite separation from the launch vehicle (LV) to its orbit, in almost all situations, the satellite subsystems (attitude determination and control, communication and onboard computer and data handling (OBC&DH)), take their needed power from a storage battery (SB) and solar arrays (SA) besides the consumed power in the EPS management device. At this point (separation point, detumbling mode), the satellite's angular motion is high and the orientation of the solar arrays, with respect to the Sun, will change in a non-uniform way, so the amount of power generated by the solar arrays will be affected. The objective of this research is to select satellite EPS component types, to estimate solar array illumination parameters and to determine the efficiency of solar arrays during both detumbling and normal operation modes.

Design and Implementation of Optimal Control Algorithms for Building Energy Management (빌딩 에너지 관리 최적화 알고리즘 설계 및 구현)

  • Jin Jung-Hwa;Chung Sun-Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.10
    • /
    • pp.969-976
    • /
    • 2004
  • Building energy saving is one of the most important issues in these days. Energy saving control strategies should be developed properly to achieve the saving. One of such area we could apply is the HVAC (Heating, Ventilation and Air-Conditioning) system. Through the optimal control algorithm for building energy management system (EMS), you can not only save the cost of building energy, but also protect HVAC system components against the unexpected condition. In order to verify the effectiveness of building energy saving, field test was accomplished for several months at 'A' building. And to get the measured data, remote control was used. If the remote control is used in BAS (Building Automation System), control and monitoring can be done for all of the building systems, such as HVAC, power, lighting, security and fire-alarm etc. anywhere any time. Using the remote control, Control and monitoring is possible for the testing system without going there. As the results of field test, we could reduce $5{\sim}10\%$ of the building energy cost.

Security Analysis of Remote Healthcare System in Cloud-based IoT Environment (클라우드 기반 IoT 환경의 원격 헬스케어 시스템에 대한 보안성 분석)

  • Kwon Jaemin;Hong Sewoong;Choi Younsung
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.19 no.1
    • /
    • pp.31-42
    • /
    • 2023
  • As computer performance is leveled upward, the use of IoT systems is gradually expanding. Although IoT systems are used in many fields, it is true that it is difficult to build a safe system due to performance limitations. To overcome these limitations, many researchers have proposed numerous protocols to improve security issues. Among them, Azrour et al. except. We proposed a new efficient and secure authentication protocol for remote healthcare systems in a cloud-based IoT environment, and claimed that the new protocol could solve the security vulnerabilities of the existing protocols and was more efficient. However, in this paper, through the security analysis of the remote healthcare system in the cloud-based IoT environment proposed by Azrour et al., the protocol of this system was found to be vulnerable to Masquerade attack, Lack of Perfect Forward Secrecy, Off-line password guessing attack, and Replay attack.