• Title/Summary/Keyword: Remote control system

Search Result 1,961, Processing Time 0.025 seconds

Development of a LonRF Intelligent Device-based Ubiquitous Home Network Testbed (LonRF 지능형 디바이스 기반의 유비쿼터스 홈네트워크 테스트베드 개발)

  • 이병복;박애순;김대식;노광현
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.6
    • /
    • pp.566-573
    • /
    • 2004
  • This paper describes the ubiquitous home network (uHome-net) testbed and LonRF intelligent devices based on LonWorks technology. These devices consist of Neuron Chip, RF transceiver, sensor, and other peripheral components. Using LonRF devices, a home control network can be simplified and most devices can be operated on LonWorks control network. Also, Indoor Positioning System (IPS) that can serve various location based services was implemented in uHome-net. Smart Badge of IPS, that is a special LonRF device, can measure the 3D location of objects in the indoor environment. In the uHome-net testbed, remote control service, cooking help service, wireless remote metering service, baby monitoring service and security & fire prevention service were realized. This research shows the vision of the ubiquitous home network that will be emerged in the near future.

Seamless Transfer Method of BESS Connected by Engine Generator (엔진발전기와 연계된 BESS의 무순단 모드 전환 기법)

  • Shin, Eun-Suk;Kim, Hyun-Jun;Kim, Kyo-Min;Yu, Seung-Yeong;Han, Byung-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.12
    • /
    • pp.1709-1717
    • /
    • 2015
  • In remote islands PV (Photo Voltaic) panel with BESS (Battery Energy Storage System) supplies electric power to the customers in parallel operation with EG (Engine Generator) to save fuel consumption and to mitigate environmental load. BESS operates in voltage control mode when it supplies power to the load alone, while it operates in current control mode when it supplies power to the load in parallel with EG. This paper proposes a smooth mode change scheme from current control to voltage control of BESS by adding proper initial value to the integral part of voltage control, and a smooth mode change scheme from voltage control to current control by tracking the EG output voltage to the BESS output voltage using PLL (Phase-Locked Loop). The feasibility of proposed schemes was verified through computer simulations with PSCAD/EMTDC, and the feasibility of actual hardware system was verified by experiments with scaled prototype. It was confirmed that the proposed schemes offer a seamless operation in the stand-alone power system in remote islands.

A Study on the LED Button Guide to improve the IPTV's Usability (IPTV 사용성 향상을 위한 LED 버튼 가이드)

  • Kim, Sung-Hee;Kim, You-Min;Jung, Jae-Wook;Lee, Dong-Wook;Ryu, Won;Hahn, Min-Soo
    • 한국HCI학회:학술대회논문집
    • /
    • 2009.02a
    • /
    • pp.933-937
    • /
    • 2009
  • The IPTV which was commercialized and is being serviced to customers at present has a complicated GUI (Graphical User Interface) to provide two-way services and a remote control containing more than 40 buttons unlike the conventional TV. Accordingly, the remote control becomes one of the causes that make the usability of the IPTV worsen. In this paper, we suggest a LED button guide system as a solution to improve a usability of the IPTV, and analyze the effects of the interface obtained from the user evaluation on the user action.

  • PDF

Knowledge-Based Unmanned Automation and Control Systems for the Wastewater Treatment Processes (하.폐수 처리장의 원격 모니터링 및 지식 기반 무인 자동화 시스템)

  • Bae, Hyeon;Jung, Jae-Ryong;Seo, Hyun-Yong;Kim, Sung-Shin;Kim, Chang-Won
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.11 no.9
    • /
    • pp.844-848
    • /
    • 2001
  • This paper introduces unmaned fully automation systems, which are applied for the CSTR(Continuously Stirred Tank Reactor) and SBR (Sequencing Batch Reactor) wastewater treatment system. The pilot plant is constructed in the country side which is little far from a main city. So networks and wireless modules are employed for the data transmission. The SBR plant has a local control and the remote monitoring system which is contained communication parts which consist of ADSL (Asymmetric Digital Subscriber Line) network and CDMA (Code Division Multiple Access) Wireless module. Remote control and monitoring systems are constructed at laboratory in a metropolis.

  • PDF

A Study on the Tele-medicine Robot System with Face to Face Interaction

  • Shin, Dae Seob
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.293-301
    • /
    • 2020
  • Consultation with the patient and doctor is very important in the examination. However, if the consultation cannot be done directly, such as corona virus, it is difficult for the doctor to determine the patient's condition more accurately. Recently, an image counseling system has been developed based on the Internet, but in the case of heart disease, remote medical counseling cannot be performed because it is not possible to stethoscope the heart sounds remotely. In order to solve this problem, it is necessary to develop an interactive mobile robot capable of remote medical consultation, and a doctor and a patient should be able to set a planting sound during consultation and transmit it in real time. In this paper, we developed a robot that can remotely control a medical counseling robot to move to a hospital room where patients are hospitalized, and to consult a patient in the room remotely from a doctor's office. A remote medical imaging stethoscope system for real-time heart sound transmission is presented. The proposed system is a kind of P2P communication that transmits video information, audio information, and control signal independently through webRTC platform, so that there is no data loss. Consults and sees doctors in real time and finds it more effective than traditional methods for patient security. The system implemented in this paper will be able to perform remote medical care in the place where the spread of diseases between humans like the recent corona 19 as well as the remote medical care of heart disease patients in the future.

Vulnerability Analysis on a VPN for a Remote Monitoring System

  • Kim Jung Soo;Kim Jong Soo;Park Il Jin;Min Kyung Sik;Choi Young Myung
    • Nuclear Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.346-356
    • /
    • 2004
  • 14 Pressurized Water Reactors (PWR) in Korea use a remote monitoring system (RMS), which have been used in Korea since 1998. A Memorandum of Understanding on Remote Monitoring, based on Enhanced Cooperation on PWRs, was signed at the 10th Safeguards Review Meeting in October 2001 between the International Atomic Energy Agency (IAEA) and Ministry Of Science and Technology (MOST). Thereafter, all PWR power plants applied for remote monitoring systems. However, the existing method is high cost (involving expensive telephone costs). So, it was eventually applied to an Internet system for Remote Monitoring. According to the Internet-based Virtual Private Network (VPN) applied to Remote Monitoring, the Korea Atomic Energy Research Institute (KAERI) came to an agreement with the IAEA, using a Member State Support Program (MSSP). Phase I is a Lab test. Phase II is to apply it to a target power plant. Phase III is to apply it to all the power plants. This paper reports on the penetration testing of Phase I. Phase I involved both domestic testing and international testing. The target of the testing consisted of a Surveillance Digital Integrated System (SDIS) Server, IAEA Server and TCNC (Technology Center for Nuclear Control) Server. In each system, Virtual Private Network (VPN) system hardware was installed. The penetration of the three systems and the three VPNs was tested. The domestic test involved two hacking scenarios: hacking from the outside and hacking from the inside. The international test involved one scenario from the outside. The results of tests demonstrated that the VPN hardware provided a good defense against hacking. We verified that there was no invasion of the system (SDIS Server and VPN; TCNC Server and VPN; and IAEA Server and VPN) via penetration testing.

750kW-class DFIG Wind Turbine Monitoring System Development and Study on Scheme for Applying Standardized Communication (750kW급 DFIG 풍력 발전기 모니터링 시스템 개발 및 통신 표준화 적용 방안에 관한 연구)

  • Lee, Duck-Su;Lee, Jun-Chul;Choi, In-Sun;Choi, Young-Jun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.327-330
    • /
    • 2008
  • This paper presents monitoring system for 750kW-class DFIG wind turbine generator system and an architecture for applying standardized communication, IEC61400-25. Monitoring and control system is consists of wind turbine PLC, Local and Remote I/O Server, HMI. and Web-server. Proposed System has been demonstrated in Daegi-ri, Kangwon-do, which aims to test local and/or remote monitoring and control system and evaluate the performance of 750kW-class WTS. Finally we described the design of logical nodes and services based on IEC61400-25 and its application scheme.

  • PDF

A Design and Implementation of Remote Control Monitor Model based on Java Applet (자바 애플릿 기반 원격 제어 모니터 모델 설계 및 구현)

  • 이정배;이종희;윤석환
    • Journal of Korea Multimedia Society
    • /
    • v.2 no.4
    • /
    • pp.430-437
    • /
    • 1999
  • In this paper, client/server model for remote conveyor control and monitoring system Is designed and implemented to simulate the product line of vehicles. The client system located at the monitoring office is using a web applet based system, and sends some commands to the server system which guards and controls the conveyer system. The commands is delivered to the server system, the driver software existing in the server controls the conveyer system directly.

  • PDF

The Development of a Remote Control System Based on Power Line Modem and Telephone for Safe Operation of the Indoor Gas Range (전력선 모뎀 및 전화를 이용한 가정용 가스레인지의 원격 제어 시스템 개발)

  • 최승지;박종연
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.7C
    • /
    • pp.723-727
    • /
    • 2002
  • In this paper a new remote control system for operating indoor gas(LPG) range safely based on PLM(Power Line Modem) and telephone is developed because it would make disasters of properties and lives by user's carelessness or worker's bad installation, etc. The system includes the following elements: a telephone line interface system for user to call from the outdoors to the indoors, a communication system using the power line as a communication media, a system of cutting off gas and a alarm system.