• Title/Summary/Keyword: Remote Diagnosis

Search Result 247, Processing Time 0.03 seconds

A Study on the Web-based Remote Pulse Diagnosis System (Web 기반 원격 맥진 시스템 구축에 관한 연구)

  • Lee, J.Y.;Lee, S.J.;Kim, J.H.;Lee, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2821-2822
    • /
    • 2001
  • This study has conducted researches in the web-based diagnosis data management system of pulse waveform as well as the method of transmitting the data of pulse waveform. In order to set the standard for the documents of the pulse waveform of patients, the web-based clinical database management system has been developed.

  • PDF

Development of Underwater ROV for Crack Inspection of River Facilities (하천 시설물 균열 검사를 위한 수중 ROV 개발)

  • Seong, Ho-Hwan;Lee, Jang-Myung
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.16 no.4
    • /
    • pp.129-136
    • /
    • 2021
  • River facilities and port structures require a regular inspection and diagnosis due to obsolescence. Currently, most river facilities are undergoing indirect inspection and diagnosis by divers. The underwater inspections are not feasible due to safety issues of divers and restrictions on working hours and environment. To overcome these issues, it is intended to conduct inspections of river facilities using underwater drones. In this research, an underwater ROV (Remote Operated Vehicle) has been developed, which is a kind of drone with propellers. As a key device of this research, an injection device has been attached to the underwater drone to conduct an operation test, a stable operation test of an underwater drone, and a test of attached sensors. The river facility inspection can be carried out optimally using the hovering control of the drone and injection systems. With the developed ROV system, hovering test and injection test have been performed to verify the feasibility of this development.

Review of Non-Contact Concrete Damage Depth Estimation Technique Based on High-Power Pulsed Laser (고출력펄스 레이저 기반 비접촉 콘크리트 열화깊이 추정 기법 검토)

  • Choe, Gyeong-Cheol;Kim, Hong-Seop;Jeon, Jun-Seo;Kim, Eun-Young;Lee, Mun-Hwan
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.267-268
    • /
    • 2023
  • Out of an estimated 7 million buildings nationwide, approximately 38% of them have been standing for over 30 years, and this number is expected to continue to increase. Additionally, due to the Building Act, safety inspections will be mandatory for approximately 70,000 buildings annually, leading to an increase in demand for building safety inspections. However, the current building safety diagnosis heavily relies on manpower, making it difficult to diagnose locations that are hard to access, and requiring lengthy investigation periods. Therefore, this paper presents the basic research results of a non-contact concrete damage depth estimation technique using laser technology aimed at remote building safety diagnosis and shortening investigation periods.

  • PDF

Development of the Integrated Monitoring System for Panel boards (분전반 통합 감시 시스템 개발)

  • Kim, Il-Kwon;Cho, Hyun-Kyung;Lee, Dong-Zoon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.347_348
    • /
    • 2009
  • In this paper, we described the integrated monitoring system for low-voltage panel boards. This system consists of three parts, a panel board controller, an integrated monitoring unit and a remote PC. The panel board controller which was made of CT/PT unit, control unit and power supply is able to transmit variable parameter for monitoring and diagnosis of low voltage branch circuits. Also, the integrated monitoring unit was collected monitoring data from panel boards and displayed on the touch panel.

  • PDF

Java-based LonTaIk/IP Network for Predictive Maintenance (PM)

  • Park, Gi-Heung
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2001.11a
    • /
    • pp.31-35
    • /
    • 2001
  • Recent trends require that access to the device/equipment information be provided from several locations or anywhere in the enterprise. One example is virtual machine/manufacturing system (VMS) where predictive maintenance is performed both on factory floor and in remote site through internet [1]. Internet access is increasingly available and affordable, and along with the "internet" is the backbone of modern enterprise data networks. Typical functions of such a system includes monitoring and control for diagnosis and remedy action in realizing preventive maintenance.(omitted)

  • PDF

Development of Remote Diagnosis System to Accumulate Abnormal Signal Data of Transformer (변압기의 이상 신호 데이터를 축적하기 위한 원거리 진단 시스템 개발)

  • Kwak, Seung Soo;Kim, Yong Sin
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2019.07a
    • /
    • pp.161-162
    • /
    • 2019
  • 본 논문에서는 변압기의 이상 신호 데이터를 원거리에서 축적하기 위한 이상 신호 진단 시스템을 제안한다. 이 시스템은 원격으로 변압기의 이상 신호를 수집하여 변압기의 이상을 알아낼 수 있다. 이 시스템은 상용된 통신 모듈의 느린 통신 속도를 고려하여 이상 신호를 RMS-DC 값으로 변환하는 작업을 추가하였다.

  • PDF

Cloud monitoring system for assembled beam bridge based on index of dynamic strain correlation coefficient

  • Zhao, Yiming;Dan, Danhui;Yan, Xingfei;Zhang, Kailong
    • Smart Structures and Systems
    • /
    • v.26 no.1
    • /
    • pp.11-21
    • /
    • 2020
  • The hinge joint is the key to the overall cooperative working performance of the assembled beam bridge, and it is also the weakest part during the service period. This paper proposes a method for monitoring and evaluating the lateral cooperative working performance of fabricated beam bridges based on dynamic strain correlation coefficient indicator. This method is suitable for monitoring and evaluation of hinge joints status between prefabricated girders and overall cooperative working performance of bridge, without interruption of traffic and easy implementation. The remote cloud monitoring and diagnosis system was designed and implemented on a real assembled beam bridge. The algorithms of data preprocessing, online indicator extraction and status diagnosis were given, and the corresponding software platform and scientific computing environment for cloud operation were developed. Through the analysis of real bridge monitoring data, the effectiveness and accuracy of the method are proved and it can be used in the health monitoring system of such bridges.

Development of diagnosis system of motor for a ship. (선박용 전동기 진단장치 개발에 관한 연구)

  • 강대규;김종윤;이성근;김윤식
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.474-478
    • /
    • 2001
  • This paper proposes integrated diagnosis system of motor for a ship. It carried out the safety diagnosis for insulation-resistor and current. The motor exposed to sea breeze and oil all the time is able to have problems as a over-current, reduction of the insulation-resistor and so on. These problems impact on the safety navigation, and occur a heavy casualties and loss of property. The proposed system is designed to verify continuous values of the insulation-resistor and current, and transfer them to a remote control room. The validity of the proposed system is verified through experiments on the 3-phase induction motor.

  • PDF

Development of an On-Line Insulation Diagnosis System when operating a High-Voltage Motor Using a Ceramic Coupler (세라믹 커플러를 이용한 고압 전동기 운전 중 절연 진단 시스템 개발)

  • Se, Il-Soo;Shin, Byoung-Chol;Lee, Sang-Min;Oh, Bong-Keun;Kim, Hyeon-Il
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1440-1442
    • /
    • 2007
  • A high-voltage motor has had many problems due to its frequent startup, standstills and occasions of long period operation. As for a solution to the problem, many advanced countries have developed an on-line insulation diagnosis sensor and a same type of system and put them in use. Recently, even in the domestic market, a ceramic coupler has been developed and attempted to be applied in the field. This paper proposes an on-line insulation diagnosis system when operating a high-voltage motor along with the use of a domestic ceramic coupler. The proposed system is composed with a ceramic sensor, a PDMS-HM, and a Remote Monitoring System. As the result of comparing this system with a PDAS, which is an expensive full A/D method, the reliability of the system has been verified, and furthermore, it is in the process of being commercialized.

  • PDF

Implementation of PC based Motor Fault Diagnosis System (PC 기반 전동기 고장 진단 시스템의 구현)

  • Doo, Seung-Ho;Park, Jin-Bae;Kwak, Ki-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2195-2196
    • /
    • 2006
  • This study is for implementation of PC based Motor fault diagnosis system. By using harmonics and current signals of the motor, this system diagnoses the motor condition by accumulated harmonic contribution rate. In this proposed system that was composed of 5 parts. A sensor, connection box, evaluation board, device server, and main computer are those. There were two types of sensor, one was harmonic sensor the other was current sensors. The signal was acquired by sensor, and transferred to evaluation board. Second one is connection box. Because the output type of sensor and input type of evaluation board is different, connection box was necessary. Third one was evaluation board. The signal from the sensor was converted to digital signal in evaluation board. And this signal was transferred to device server. Fourth one was device server. Device server transferred the data from evaluation board to main computer. And the last one was other parts controlled by main computer. In main computer, there were communication and diagnosis algorithms. The result was derived by main computer. In the result, there were 12 categories and 5 levels of motor conditions. The proposed system had some advantages comparing with stand alone type commercial motor fault diagnosis system. The first, by using remote access it was easier to get the conditions of motor. The second, there was no need to handle the sensors when users measured the motor signals. By this property, no one was necessary at motor location site. The third, this system was less restricted by times and places than commercial stand alone type diagnosis system. Therefore users can operate this system only using the main computer. Once the sensors are installed at the motor, users doesn't need to move to check up the condition of motors. Moreover, if there is ethernet hub, many motors can be not only diagnosed at once but also decreased its cost.

  • PDF