• Title/Summary/Keyword: Relux

Search Result 30, Processing Time 0.035 seconds

Lighting Simulation using Relux (Relux를 이용한 조명 시뮬레이션)

  • Hong, Sung-De
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.11 no.1
    • /
    • pp.83-90
    • /
    • 2011
  • Lighting simulation is becoming increasingly more important as a method for design and evaluation. There is a wide range of packages that provide the accuracy and the usability in lighting simulation. Relux developed by Relux Informatik AG, Switzerland, Relux offers users innovative and high-performance light planning software with open interfaces and simultaneous access to the latest product data from luminaire and lamp manufacturers. The goals of this report is to explore some of the lighting simulation issues relating to Relux. It is hoped that it will provide some background information that will enable a designer and engineer to make some informed judgements on the potential of the current state-of-the-art in computer prediction of lighting in buildings and how this may be used to assist in building design.

The comparison between measurement and prediction values for the vertical illuminances by relux program in the survey region (상용 조명해석 프로그램(Relux)을 이용한 가로등 주택침입광 예측값과 실측값 비교)

  • Jung, Dae-Kwan;Park, Hyung-Kyu;Jung, Joon-Sig
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.98-104
    • /
    • 2018
  • The assessment of the light trespass in terms of light pollution is difficult due to the complexity of light environments. As a result, the light pollution research has examined the influences of light pollution using simulation program such as RELUX. However, there still exists a differences between the real measurement value and the simulation value for the light trespass. In this paper, we analyzed the light trespass using the RELUX simulation program, and compared results with real measurement values. In this study, the regions (Seoul, Incheon, etc.) were investigated regarding the light trespass for outdoor lighting. The survey of vertical illuminance was analyzed measuring point (more than 2 point) out the window that was expected to light trespass for the higher anticipated to illumination. The illuminational predicted values for the RELUX program were compared with maximum one. As a result of this study, the illuminational errors between the measurement values and predicted values for the simulation were examined from -0.97 lx to 0.65 lx except 2.08 lx and -7.70 lx. The light trespass was analyzed the higher by how much the located close to the height, length, width of the outdoor lighting for the window. For measuring predicted values using RELUX, it was not sufficiently considered in the simulation conditions because of environmental factors and investigator error etc. Limitations of this study include the limited number of measurements, and greater field data is required in future studies.

Backlight Simulation Using the Lamp Array According to Relux (Relux를 이용한 가로등 배열에 따른 배광 시뮬레이션)

  • Choi, Yong-Chun;Yun, A-Young;Eo, Ik-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.127-128
    • /
    • 2011
  • 본 논문은 RELUX를 이용해 도로조명 중에서 일반간선도로 및 고속화 도로설계에 주로 사용되는 마주보기와 지그재그 배열을 시뮬레이션 하는 실험 논문이다. 1차로 Starts an Artificial Light Calculation 시뮬레이션 분석을 하여 비교분석하였고 2차 General 시뮬레이션 분석 결과 값이 거의 일치 하게 나왔다. 배열이 달라도 차이가 없음을 확인하였다.

  • PDF

Research on the Characteristics of the Light Trespass using by RELUX Program According to the Spatial Position of the Road Lightings in Residential Area Near Road (조명시뮬레이션 프로그램(RELUX)을 이용한 도로조명의 공간적 배치에 따른 침입광 영향 특성 연구)

  • Gu, Jinhoi;Jung, Jong-Hwan;Lee, Kyumok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.11
    • /
    • pp.1-8
    • /
    • 2012
  • The road lightings have made our living environment safe and active, since it was first installed in 1900 in Korea. As the industry developed, various kind of road lightings have been installed in an outdoor area. But the spilt light from the road lightings have caused health problem like the sleeplessness, the depression, the failure to thrive and the nearsightedness to children. The light trespass caused by road lightings vary with the height of road lightings, the distance from road lightings to the window and the BUG rating of road lightings. In this paper, we analyze the effect on the light trespass by the spatial installation position of road lightings using by RELUX program. And we derive the characteristics of the light trespass according to the spatial installation position of the road lightings in residential area near road.

Lighting Design of Lecture Room by using Relux (Relux를 이용한 강의실 조명설계)

  • Shin, Yeon-Soo;Eo, Ik-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2241_2242
    • /
    • 2009
  • 본 논문은 강의실 조명설계로 2/40W FL${\times}$9와 2/25W LED FL${\times}$12를 Relux 2007를 이용하여 모델링을 통한 시뮬레이션을 측정 하였으며, 두 램프를 비교 분석하여 가장 이상적인 조명기구 및 조도 값을 알아본다. 이 시뮬레이션 결과 2/40W FL${\times}$9의 경우가 2/25W LED FL${\times}$12를 사용했을 때 보다 조도와 균제도가 높게 측정되었고, 소비전력은 2/25W LED FL${\times}$12 매입했을 때가 낮게 나왔다. 금후 LED 형광등 조명설계에 있어서 도움을 줄 수 있을 것으로 기대된다.

  • PDF

A Fundamental Study for Proper Application of Lighting Simulation Software (조명시뮬레이션 소프트웨어의 적합한 사용을 위한 기초적 연구)

  • Kim, Yu-Sin;Won, Seul-Ki;Park, Byoung-Chul;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.8
    • /
    • pp.10-19
    • /
    • 2007
  • Use of various lighting simulation software has been increased Lighting simulation software can be categorized into two types. One is for optical design while the other is for estimation and analysis of lighting design. Photopia 2.0 is typical software for optical design of a luminare and Lumen-micro 2000, Relux 2006, Lightscape 3.2 and AGI 32 are software for lighting design. Through using various lighting simulation software some different results can be found under the same conditions. Therefore, the purpose of this paper is to compare measured and simulated photometric data of different types of luminaires and to compare simulated values from Lumen-micro 2000, Relux 2006, Lightscape 3.2 and AGI 32 under the same conditions. In addition, the reasons for such differences are analyzed.

The Illumination Simulation in the Greenhouse using Daylight and Artificial Light for Energy Saving. (에너지 절감을 위한 자연광과 인공광원을 활용한 유리온실 조도 시뮬레이션)

  • Lee, Boong-Joo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.9
    • /
    • pp.1359-1363
    • /
    • 2017
  • In this study, the Relux program was simulated for optimum conditions of daylight and artificial light sources(LED) in the glass greenhouse. From the results of daylight simulation, the optimum design conditions for the glass greenhouse were established which were 90[o] installation angle and higher transmittance. In this case of growing lettuce in the glass greenhouse, the control method of the only artificial light source was compared that of daylight and LED. The result of illumination simulation produced a power consumption effect of 37.2[%] in the summer and 51.9[%] in the winter, respectively. From this results, we propose to suggest that we grow the lettuce in the energy saving glass greenhouse.

A Study on the Comparison of the Illuminance Values from Daylight Simulation and Mock-up Experiment for Suitable Application of Lighting Simulation (적합한 조명시뮬레이션 사용을 위한 주광 시뮬레이션과 Mock-up 실험 비교에 관한 연구)

  • Kim, Yu-Sin;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.35-44
    • /
    • 2010
  • Available daylight in inside offers comfortable view environment, and psychological and physical advantages to people in a room. Architectural design has a need for daylight prediction. But it is difficult to predict the illuminance values in daylight system. Using various Daylight simulation software is easy and simple, but we can find different results under the same conditions. This study compares with illuminance values from simulation (Lightscape 3.2, Relux 2007, Radiance 3.9) and Mock-up experiment with a same space and parameter of daylight (location of space and window, date, time and sky condition).

150 W LED Streetlight Optimal Design Using 21 W LED Engine (21 W LED 엔진을 이용한 150 W급 가로등의 최적설계)

  • Shin, Wang-Soo;Lee, Seung-Min;Kim, Beom-Su;Park, Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.1
    • /
    • pp.62-67
    • /
    • 2016
  • In this paper, the IES file was measured by applying a secondary optical lens to a 21 W LED engine, and the lighting calculation software RELUX was used to perform simulations with the data file of this measurement. For two-lane (two way) concrete paved roads, six LED engine are applied to each streetlight and simulation results show that Uo (uniformity) 0.56, UI (longitudinal uniformity) 0.86 and TI (threshold iIncrement) 9% which satisfies the required standards. RELUX was also used to LED streetlights by designing them in three dimensions, that is ${\pm}25%$ of the arm length of 2.8 m standardized by the road lighting standards of the Korea Expressway Corporation. Comparative analysis was carried out on adjustments were made in increments of 0.1 m that Uo, UI, and TI values in the range of arm lengths from 2.1 m~3.5 m. For the arm length range of 2.1 m~2.4 m, Uo was high, whereas UI was low. Therefore, we present the optimal light distribution values designed for an arm length of 2.5 m.

A study on selecting of Light Cutoff Panel depending on the installation condition using the lighting simulation (조명 시뮬레이션을 이용한 설치 환경별 차광판 선정에 관한 연구)

  • Park, Hyung-Kyu;Gu, Jin-Hoi;Lee, Kyu-Mok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.246-251
    • /
    • 2016
  • The use of security lighting that emits spill light is considered a cause of light trespass problems in the residential areas. Therefore, a cutoff panel was installed as an alternative way to reduce light trespass. On the other hand, it has another problem in that it is less effective and is not good enough for aesthetics and safety. In this study, a light cutoff panel was designed and manufactured to reduce the light trespass, and the structure of a proper light cutoff panel was studied. Using a goniophotometer, the light distribution file (IES file) was extracted and the characteristics of light distribution were analyzed using the RELUX program. The results showed that the reduction of spilt light in the backward direction was decreased significantly for all types of light cutoff panels except the coated globe. In the case of a black powder coated light cutoff panel, the forward light caused by light reflected from the surface of the light cutoff panel was also reduced, which means that the black powder coated light cutoff panel is effective in the performance of light cutoff in the forward and backward directions. In addition, the coated glove increased the spilt light in the forward and backward directions because it reflects the upward light to go down. A 90 % accuracy between the measurement value of light trespass and the expected value of the light trespass was obtained from a simulation.