• 제목/요약/키워드: Relining

검색결과 55건 처리시간 0.025초

Effect of repair methods and materials on the flexural strength of 3D-printed denture base resin

  • Viotto, Hamile Emanuella do Carmo;Silva, Marcela Dantas Dias;Nunes, Thais Soares Bezerra Santos;Coelho, Sabrina Romao Goncalves;Pero, Ana Carolina
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권5호
    • /
    • pp.305-314
    • /
    • 2022
  • PURPOSE. The aim of this study was to evaluate the flexural strength of a 3D-printed denture base resin (Cosmos Denture), after different immediate repair techniques with surface treatments and thermocycling. MATERIALS AND METHODS. Rectangular 3D-printed denture base resin (Cosmos Denture) specimens (N = 130) were thermocycled (5,000 cycles, 5℃ and 55℃) before and after the different repair techniques (n = 10 per group) using an autopolymerized acrylic resin (Jet, J) or a hard relining resin (Soft Confort, SC), and different surface treatments: Jet resin monomer for 180 s (MMA), blasting with aluminum oxide (JAT) or erbium: yttrium-aluminum-garnet laser (L). The control group were intact specimens. A three-point flexural strength test was performed, and data (MPa) were analyzed by ANOVA and Games-Howell post hoc test (α = 0.05). Each failure was observed and classified through stereomicroscope images and the surface treatments were viewed by scanning electron microscope (SEM). RESULTS. Control group showed the highest mean of flexural strength, statistically different from the other groups (P < .001), followed by MMA+J group. The groups with L treatment were statistically similar to the MMA groups (P > .05). The JAT+J group was better than the SC and JAT+SC groups (P < .05), but similar to the other groups (P > .05). Adhesive failures were most observed in JAT groups, especially when repaired with SC. The SEM images showed surface changes for all treatments, except JAT alone. CONCLUSION. Denture bases fabricated with 3D-printed resin should be preferably repaired with MMA+J. SC and JAT+SC showed the worst results. Blasting impaired the adhesion of the SC resin.

A STUDY ON THE ADHESION OF A SOFT LINER CONTAINING 4-META TO THE BASE METAL ALLOY AND ITS VISCOELASTIC PROPERTY

  • Park Hyun-Joo;Kim Chang-Whe;Kim Yung-Soo
    • 대한치과보철학회지
    • /
    • 제41권6호
    • /
    • pp.732-746
    • /
    • 2003
  • Statement of problem. Soft lining materials, also referred to as tissue conditioning materials, tissue heating materials, relining materials, soft liners or tissue conditioners, were first introduced to dentistry by a plastic manufacturer in 1959. Since the introduction of the materials to the dental field, their material properties have been continually improved through the effort of many researchers. Soft lining materials have become widely accepted, particularly by prosthodontists, because of their numerous clinical advantages and ease of manipulation. Unfortunately, few reports have been issued upon the topic of increasing the bond strength between the base metal alloy used in cast denture bases and PMMA soft liner modified with 4-META, nor upon the pattern of debonding and material change in wet environment like a intra oral situation. Purpose. The purposes of this study were comparing the bond strength between base metal alloy used for the cast denture bases and PMMA soft liner modified with 4-META, and describing the pattern of debonding and material property change in wet environment like the intraoral situation. Material and Methods. This study consisted of four experiments: 1. The in vitro measurement of shear bond strength of the adhesive soft liner. 2. The in vitro measurement of shear bond strength of the adhesive soft liner after 2 weeks of aging. 3. A comparison of debonding patterns. 4. An evaluation the Relation time of modified soft liner. The soft liner used in this study was commercially available as Coe-soft (GC America.IL.,USA), which is provided in forms of powder and liquid. This is a PMMA soft liner commonly used in dental clinics. The metal primer used in this study was 4-META containing primer packed in Meta fast denture base resin (Sun Medical Co., Osaka, Japan). The specimens were formed in a single lap joint desist which is useful for evaluating the apparent shear bond strength of adhesively bonded metal plate by tensile loading. Using the $20{\times}20mm$ transparent grid, percent area of adhesive soft liner remaining on the shear area was calculated to classify the debonding patterns. To evaluate the change of the initial flow of the modified adhesive soft liner, the gelation time was measured with an oscillating rheometer (Haake RS150W/ TC50, Haake Co., Germany). It was a stress control and parallel plate type with the diameter of 35mm. Conclusion. Within the conditions and limitations of this study, the following conclusions were drawn as follows. 1. There was significant increase of bond strength in the 5% 4-META, 10% 4-META containing groups and in the primer coated groups versus the control group(P<0.05). 2. After 2 weeks of aging, no significant increase in bond strength was found except for the group containing 10% 4-META (P<0.05). 3. The gelation times of the modified soft liner were 9.3 minutes for the 5% 4-META containing liner and 11.5 minutes for the 10% 4-META liner. 4. The debonding patterns of the 4-META containing group after 2 weeks of aging were similar to those of immediaely after preparation, but the debonding pattern of the primer group showed more adhesive failure after 2 weeks of aging.

Locator attachment를 이용한 하악 임플란트 유지형 피개의치의 임상적 평가 (Clinical evaluation of implant retained overdentures using two implant and Locator attachments in the fully edentulous mandibles)

  • 이주형;손동석
    • 대한치과보철학회지
    • /
    • 제49권4호
    • /
    • pp.283-290
    • /
    • 2011
  • 연구 목적: 현대의학의 발달로 평균 수명이 증가하고 고령의 환자가 늘어남에 따라 무치악 환자의 비율도 증가하고 있다. 특히 심하게 흡수된 하악골에선 기존의 총의치로는 환자가 사용하기에 유지, 지지의 부족으로 사용상에 어려움이 있다. 하악에 2개의 임플란트 식립하여 피개의치를 제작하면 환자에게 좀 더 사용하기가 편한 의치를 제작해 줄 수 있다. 간단한 보철과정과 추후 수리가 쉽다는 이유로 현재 Locator가 보편적인 유지장치로 사용되고 있다. Locator를 이용한 하악 임플란트 유지 피개의치에서 임플란트와 보철물의 장기적인 성공률을 알아보았다. 연구 재료 및 방법: 대구가톨릭대학병원 치과 구강외과에서 2004년부터 2010년까지 총 10명의 환자(남 4명, 여 6명)의 하악에 2개의 임플란트(총 20개)를식립후Locator를 이용한 조직-유지 피개의치를 하였다. 본 연구는 최근 7년간 시술된 10명의 환자들을 대상으로 진료 기록부를 조사하고 방사선 사진을 계측하여 후향적 임상연구를 하였으며, 임플란트의 생존률 및 보철적인 합병증에 대해 알아보았다. 결과:임플란트는 100%의 누적 성공률을 보였고, 1년후(평균 58주) 방사선 사진에서 임플란트는 평균 1.03 mm ${\pm}$ 0.20 mm의 골소실을 보였으며, 임플란트의 기능에는 이상을 보이지 않았다. 피개의치는 의치파절, 의치상 이장 또는 개상, 메일의 탈락 또는 유지력 감소로 인한 메일 교체 등 다양한 합병증을 보였다. 그러나 의치상 이장 및 개상, 메일 인써트의 간단한 교체로 인해 장기적으로 임플란트 및 임플란트 유지 피개의치가 환자에게 유지되고 있었다. 결론: 하악 전방부위에 임플란트 2개를 식립 후 Locator를 이용한 임플란트 유지 하악 피개의치는 최소침습적인 수술, 간단한 보철 과정 및 수리 과정의 장점으로 인해 장기적으로 안정적인 치료법으로 사료된다.

피개의치를 이용한 지적장애인의 완전구강회복 (Full Mouth Rehabilitation with a Overlay Denture)

  • 고경호;김대곤;박찬진;조리라
    • 구강회복응용과학지
    • /
    • 제28권4호
    • /
    • pp.385-395
    • /
    • 2012
  • 본 증례보고는 구순구개열과 부정교합을 가진 지적장애인에게 피개의치를 이용하여 수복한 증례이다. 환자는 교정치료와 악교정수술이 필요한 광범위한 부정교합을 가진 상태였으나 치료시간과 비용, 환자의 관리능력을 고려하여 피개의치를 대체적인 치료방법으로 선택하였다. 구강내검사, 구강외검사 및 방사선검사를 시행하였으며 보철수복을 위해 수직교합고경을 평가하였고 진단모형에서 써베잉을 시행하였다. 치아 및 조직부 언더컷을 고려하여 치아의 외형을 재형성하였다. 구강형성이 완료된 후 최종인상을 채득하였다. 납의치를 이용하여 수직고경과 교합을 평가한 후 의치를 온성하였다. 교합기 상에 치료실재부착을 하여 교합조정을 시행하였다. 환자는 의치의 심미성과 기능에 만족하였으며 피개의치는 안정적 교합상태를 보였다. 이 환자에게 시행한 피개의치 치료는 가역적이고 상대적으로 저렴한 치료법이지만 구강위생이 나쁘면 치아우식이나 치주염이 발생할 가능성이 있기 때문에 정기적이고 전문적인 관리가 필요할 것으로 사료된다.

엇갈린 교합을 가진 부분 무치악 환자에서 지르코니아 교합면을 가지는 Implant-Retained RPD 이용한 전악 수복 증례 (Full mouth rehabilitation of a partially edentulous patient with crossed occlusion using implant-retained RPD with zirconia occlusal table)

  • 권태민;서치원;김경아;안승근;서재민
    • 구강회복응용과학지
    • /
    • 제32권4호
    • /
    • pp.314-321
    • /
    • 2016
  • 기존의 후방 연장 국소의치는 재이장을 위한 잦은 내원의 필요성, 클래스프에 의한 지대치로의 과도한 응력, 클래스프의 노출에 의한 비심미성 등의 단점이 있다. 이에 임플란트를 이용하여 부가적인 지지나 유지를 얻는 Implant-assisted RPD(IARPD)는 국소의치의 안정성과 심미성, 그리고 저작 효율 증진에 도움을 줄 수 있다. 또한 의치의 교합면을 지르코니아로 교체한다면 인공치 마모로 인한 대합치의 정출 및 교합평면의 부조화를 예방할 수 있을 것이다. 본 증례는 엇갈린 교합을 가진 상하악 부분 무치악 환자에서 임플란트 고정성 보철물과 임플란트 유지 국소의치를 제작하여 전악 재건 시행한 증례로 주기적인 내원을 통해 기능적, 심미적으로 만족할만한 결과를 얻었기에 보고하고자 한다.