• Title/Summary/Keyword: Reliable transfer

Search Result 441, Processing Time 0.025 seconds

Reconstruction of the Soft Tissue Defect of the Finger Using Digital Island Flap with Supercharged Vein (손가락섬피판으로 손가락 연조직 재건시 과급정맥문합)

  • Choi, Hwan Jun;Kim, Nam Joong;Choi, Chang Yong
    • Archives of Plastic Surgery
    • /
    • v.36 no.2
    • /
    • pp.153-160
    • /
    • 2009
  • Purpose: The heterodigital or homodigital artery island flap is a popular method of reconstruction for finger defects. Sometimes, digital artery island flap has some disadvantages such as postoperative flap edema, congestion, and partial necrosis of the flap margin. However, we could decrease these disadvantages by means of venous superdrainage. The aim of this study is to report usefulness and postoperative results of venous supercharging digital artery island flaps for finger reconstruction. Methods: From March of 2005 to March of 2008, a total of eight patients with soft tissue defects of the finger underwent venous supercharging digital island flap transfer. Briefly, the flap is harvested along with dorsal vein that is then anastomosed to a recipient vein in an end - to - end fashion, after flap transfer and insetting. Using this technique, eight patients were operated on, ranging in age 23 to 52 years. Results: All the flaps survived with a success rate of 100 percent, thus fully satisfying the reconstructive requirements. No postoperative flap congestion was recognized, obviating the need to take any measures for venous engorgement, such as suture removal. Among 8 cases, it was possible to make an long - term and follow - up observation more than 6 months. In these cases, the fact that light touches and temperature sensations can be detected in all the flaps. Cold intolerance and hyperesthesia were not seen in our series. Conclusion: Providing good harmony with conventional methods and microsurgery, inclusion of a vein with the heterodigital and homodigital artery island flap allows a more reliable and safer reconstructive choice for finger defects. The venous supercharged island flap is a reliable flap with a consistent arterial structure, and with its augmented venous drainage, it is more reliable, providing single - stage reconstruction of adjacent finger defects, including the fingertip.

Design of a Reliable Data Diode System (신뢰성 있는 단방향 데이터 전송 시스템 설계)

  • Kim, Dongwook;Min, Byunggil
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.26 no.6
    • /
    • pp.1571-1582
    • /
    • 2016
  • One of the issues, which is dealed with in undirectional data transmission technology, is reducing the packet loss in TCP based data transfer. We can decrease the packet loss by using several well known error correction approaches. Although we utilize those previous approaches, the packet loss by both link errror and buffer overflow could be occurred. In this paper, we propose the RED(REliable Data diode). RED also uses the TCP proxy approach for supporting the TCP based data transfer which is similar with the existing unidirectional data transmission technologies. The RED transmission system could alleviate the packet loss caused by buffer overflow by exploiting the delaying transmission of TCP packets. Furthermore, in order to reduce the packett loss caused by link error in the unidirectional transmission link, the RED transmission system transmits one or more duplicated packets to the RED reception system by considering both the remaining resources and packet importance.

PUMP DESIGN AND COMPUTATIONAL FLUID DYNAMIC ANALYSIS FOR HIGH TEMPERATURE SULFURIC ACID TRANSFER SYSTEM

  • Choi, Jung-Sik;Shin, Young-Joon;Lee, Ki-Young;Yun, Yong-Sup;Choi, Jae-Hyuk
    • Nuclear Engineering and Technology
    • /
    • v.46 no.3
    • /
    • pp.363-372
    • /
    • 2014
  • In this study, we proposed a newly designed sulfuric acid transfer system for the sulfur-iodine (SI) thermochemical cycle. The proposed sulfuric acid transfer system was evaluated using a computational fluid dynamics (CFD) analysis for investigating thermodynamic/hydrodynamic characteristics and material properties. This analysis was conducted to obtain reliable continuous operation parameters; in particular, a thermal analysis was performed on the bellows box and bellows at amplitudes and various frequencies (0.1, 0.5, and 1.0 Hz). However, the high temperatures and strongly corrosive operating conditions of the current sulfuric acid system present challenges with respect to the structural materials of the transfer system. To resolve this issue, we designed a novel transfer system using polytetrafluoroethylene (PTFE, $Teflon^{(R)}$) as a bellows material for the transfer of sulfuric acid. We also carried out a CFD analysis of the design. The CFD results indicated that the maximum applicable temperature of PTFE is about 533 K ($260^{\circ}C$), even though its melting point is around 600 K. This result implies that the PTFE is a potential material for the sulfuric acid transfer system. The CFD simulations also confirmed that the sulfuric acid transfer system was designed properly for this particular investigation.

Number of Trials for the Reliable Golf Swing Ground Reaction Force Data Collection and Its Characteristics (골프 드라이버스윙 시 지면반력 반복측정 횟수와 지면반력 특성)

  • Park, Young-Hoon;Youm, Chang-Hong;Seo, Kuk-Woong;Seo, Kook-Eun
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.4
    • /
    • pp.115-125
    • /
    • 2007
  • Grould Reaction force(GRF) is important in human movements and GRF measurements are one of the most frequently used tool in biomechanical studies. In the studies of the golf swing motion, people refer to GRF as weight transfer. A successful golf swing motion requires many segments activation sequences which are controled by the nerve system. Due to the inter- and intra-individual variability of the human movement and the movement strategies, reliability of the measurements are important in human movement studies. Previous golf researches were based on group studies and certain events' values were analyzed. The purposes of this study were to determine the number of trials for the reliable golf swing GRF data collection, to reveal the variability level of the meaningful components of the golf swing GRF, and to classify the types of the golf swing GRF patterns. Twenty three male professional golfers($26.4{\pm}6.6$ years, $174.3{\pm}5.2\;cm$, $71.3{\pm}6.5\;kg$) signed an informed consent form prior to participation in this study. GRFs of driver swings were collected with Kistler 9285 force platform and 9865A amplifier, and calculated by the KwonGRF program(Visol, Korea). Sampling frequency was 1080 Hz. GRF data were trimmed from 1.5 s prior to the impact to 0.5 s after the impact. The number of trials for the reliable GRF collection was determined when the change in floating mean overs the 25 % of the standard deviation of that variable. Variabilities of the variables were determined by the coefficient of variation(CV) of 10 %. The types of GRF patterns were determined by visual inspection of the peak GRF shapes. The minimum number of trials for the reliable golf swing GRF data collection was five. Ten-trial seems more conservative. The value of the peak GRF was more reliable than the value of the impact GRF. The CV of the peak GRF and impact GRF were 7.4 %, 15.2 %, respectively. Because of the +/- sigh of the peak GRF appearance time, it was impossible to calculate CV of the peak GRF appearance time. Golf swing GRF patterns were classified as sing peak type, double peak type, and plateau peak type. This classification suggests the presence of the different golf swing weight transfer strategies.

Comparison of Achievable Efficiency for Different Resonator Structures in a Magnetic Resonance-based Wireless Power Transfer System (자기 공진 기반의 무선전력전송 시스템에서 송수신 공진기의 구조 차이에 따른 달성 가능한 효율 비교)

  • Lee, Kisong;Yang, Haekwon;Ra, In-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.5
    • /
    • pp.1035-1041
    • /
    • 2017
  • In magnetic resonance-based wireless power transfer (WPT) systems, frequency splitting phenomenon, in which power transfer efficiency (PTE) decreases seriously as resonators are close to each other, is the problem that we should address for reliable power transfer in short distance. In this paper, we present WPT systems using an equivalent circuit model and analyze PTE and marginal coupling coefficient ($k_{split}$) where the frequency splitting occurs. In addition, we perform circuit-level simulations using Advanced Design System, and show that the achievable PTE is different for the structures of resonators when k>$k_{split}$. We confirm that higher PTE can be ensured as k increases in the case of identical resonators, while PTE is degraded as k increases in the case of non-identical resonators. Therefore, in short distance, in which k>$k_{split}$, it is more efficient for achieving reliable PTE to use identical resonators rather than non-identical resonators.

Evaporation Heat Transfer Characteristics of $CO_2$ in a Horizontal Tube

  • Lee Dong-Geon;Son Chang-Hyo;Oh Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.3
    • /
    • pp.297-305
    • /
    • 2005
  • The evaporation heat transfer coefficient of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver. a variable-speed pump. a mass flow meter. a pre-heater and evaporator (test section). The test section consists of a smooth. horizontal stainless steel tube of 7.75 mm inner diameter. The experiments were conducted at mass flux of 200 to $500\;kg/m^{2}s$. saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$. and heat flux of 10 to $40\;kW/m^2$. The test results showed the evaporation heat transfer of $CO_2$ has greatly effect on more nucleate boiling than convective boiling. The evaporation heat transfer coefficients of $CO_2$ are highly dependent on the vapor quality. heat flux and saturation temperature. The evaporation heat transfer coefficient of $CO_2$ is very larger than that of R-22 and R-134a. In making a comparison between test results and existing correlations. the present experimental data are the best fit for the correlation of Jung et al. But it was failed to predict the evaporation heat transfer coefficient of $CO_2$ using by the existing correlation. Therefore. it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in a horizontal tube.

Evaporation Heat Transfer Characteristics of $CO_2$ in a Horizontal Tube

  • Son Chang-Hyo;Kim Dae-Hui;Choi Sun-Muk;Kim Young-Ryul;Oh Hoo-Kyu
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.4
    • /
    • pp.167-174
    • /
    • 2005
  • The evaporation heat transfer coefficient of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator (test section). The test section consists of a smooth horizontal stainless steel tube of 7.75 mm inner diameter. The experiments were conducted at mass flux of 200 to $500kg/m^2s$, saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$, and heat flux of 10 to $40kW/m^2$. The test results showed the evaporation heat transfer of $CO_2$ has greater effect on nucleate boiling than convective boiling. The evaporation heat transfer coefficient of $CO_2$ is highly dependent on the vapor quality, heat flux and saturation temperature. The evaporation heat transfer coefficient of $CO_2$ is very larger than that of R-22 and R-134a. In comparison with test results and existing correlations, the best fit of the present experimental data is obtained with the correlation of Jung et al. But the existing correlations failed to predict the evaporation heat transfer coefficient of $CO_2$. Therefore, it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in a horizontal tube.

Shape Optimization of Cooling Channel with V-shaped Ribs (V-형 리브가 부착된 냉각유로의 형상 최적설계)

  • Lee, Young-Mo;Kim, Kwang-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.2 s.41
    • /
    • pp.7-15
    • /
    • 2007
  • A numerical procedure for optimizing the shape of three-dimensional channel with V-shaped ribs extruded on both walls has been carried out to enhance the turbulent heat transfer. The response surface based optimization is used as an optimization technique with Reynolds-averaged Wavier-stoked analysis. Shear stress transport (SST) turbulence model is used as a turbulence closure. Computational results for average heat transfer rate show good agreements with experimental data. The objective function is defined as a linear combination of heat transfer and friction loss-related terms with a weighting factor. Three dimensionless variables such as, rib pitch-to-rib height ratio, rib height-to-channel height ratio, and the attack angle of the rib are chosen as design variables. Nineteen training points obtained by D-optimal designs for three design variables construct a reliable response surface. In the sensitivity analysis, it is found that the objective function is most sensitive to the ratio of rib height-to-channel height ratio. And, optimal values of design variables have been obtained in a range of the weighting factor.

The Industrial Security along with the International Transfer of Technology (국제기술이전계약에서의 산업보안에 관한 연구)

  • SEO, Jung-Doo
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.76
    • /
    • pp.1-20
    • /
    • 2017
  • The industrial technology (including trade secrets), which is commonly understood as systematic and applied technical knowledge, can be transferred to third parties by contracting for the transfer of technology or by granting of a licence. The activity of industrial espionage, due to the gradual increase of the economic interests of intellectual property, is displaying intensively in order to gain advanced technology information. With our outstanding high technology, but compared to the level of the advanced countries, the technical protection systems, the legal protection measures and the systematic management thereof may still be insufficient. Our industrial technology outflow abroad, due to the vulnerability to the security control system in our country, has been increasing since the 2000. Computer software and SNS, such as smart devices, appear as a rapid change in the technical information environment. In order to minimize the dead zone of a new industrial security, the country's organic activity is being conducted. In 2006, Industrial Technology Outflow Prevention and Protection Law was enacted, which emphasized the responsibilities of the country. In this paper for the economic entity's efforts to prevent technology leakage oversea, I have looked to how the industrial technology can be protected in terms of national security and economic benefits of our enterprises. To solve the above-mentioned problems hereof, Korean government should willingly establish a reliable legal system for supporting to enterprise's operations, and Korean companies should autonomously introduce a synthetic technology protection system and incorporate the confidentiality clauses in an international transfer of technology agreement with third parties.

  • PDF

Development of OHS System Driven by Linear Motor for Automatic Transfer of LCD Panels (선형전동기를 적용한 LCD 패널 자동반송용 순환궤도차량 시스템 개발)

  • Kim, Won-Gon;Yun, Jong-Bo;Park, Gun-Woo;Hwang, Gye-Ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.7 no.3
    • /
    • pp.11-16
    • /
    • 2008
  • The authors investigated an overhead shuttle (OHS) system for automatic transferring the liquid crystal display (LCD) panels. The constructed tracks of OHS system include the linear and curve regions and have been installed on the ceiling to transfer the cassette of LCD glass along the closed-loop and open-loop tracks. In this study, the OHS system was implemented by a proposed linear motor to solve encoder installation and the system cost problems of the long distance transfer system. In addition, we utilized a new algorithm of the position detection and a new control algorithm for driving linear motor. The newly developed control algorithm was demonstrated from both a computer simulation and an experimentation, indicating that the highly reliable and speedy transfer system can enhance the LCD panel productivity of commercial OHS system.

  • PDF