• 제목/요약/키워드: Reliability of Measurement

검색결과 2,422건 처리시간 0.036초

Reliability and Validity of Measurement Using Smart Phone-Based Goniometer on Pelvic Tilting Angle in Standing and Sitting Position

  • Ha, Sung-Min;Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • 제31권1호
    • /
    • pp.35-39
    • /
    • 2019
  • Purpose: The purpose of this study was to assess the intra-rater and inter-rater reliability and validity of pelvic tilting angle measurements using a smart phone-based inclinometer (Clino) compared to a palpation meter (PALM) in the standing and sitting position. This study used an interchangeable method with Clino to measure the pelvic tilting angle in the standing and sitting positions. Methods: Twenty healthy subjects were recruited. Measurements of the pelvic tilting angle in the standing and sitting positions were obtained by two examiners using the Clino and PALM. A resting session was conducted 10 minutes later to assess the intra and inter rater reliability. To assess validity of the measurement using Clino, a PALM was used as the gold standard. The intra-class correlation coefficient (ICC) was used to determine the intra and inter rater reliability of Clino and a PALM. To assess the validity, the Pearson correlation coefficients were used for two measurement techniques to measure the pelvic tilting angle in the standing and sitting positions. The statistical significance was set to ${\alpha}=0.05$. Results: Measurements of the pelvic tilt had high inter-rater reliability in the standing (ICC=0.82) and sitting (ICC=0.88) positions using Clino and intra-rater reliability in the standing (ICC=0.87) and sitting (ICC=0.91) positions using Clino. Measurements of the pelvic tilt had high validity by a comparison of PALM and Clino in the standing (r=0.83) and sitting (r=0.89) positions (p<0.05). Conclusion: The use of Clino can be recommended as a tool to replace the PALM and measure the pelvic tilt angle in the standing and sitting positions while maintaining the clinical reliability and validity.

색채동통척도의 신뢰도 연구 (Testing the Reliability of the Pain Color Circle Measurement Tool)

  • 김주희
    • 대한간호학회지
    • /
    • 제21권3호
    • /
    • pp.339-348
    • /
    • 1991
  • The study problem was to determine the reliability of the Stewart pain circle measurement tool with Korean subjects. The purpose was to assess the tool for potential use in research in Korea. The subjects were 95 primary school students and 103 university students in Seoul. The study was conducted from May to June 1990, using Stewart's pain color circle tool. To determine the difference in the rated intensity of the order of the pain color circles, statistical mean and standard deviation were employed. Item reliability and test - retest reliability were used to test for reliability. ANOVA and t-test were used to explore for differences in the rated intensity of the order of the pain color circles according to the subjects' general characteristics. The findings were as follows ; 1. Higher level pain intensity was assigned to color circle numbers 2, 4, and 6 (These contain large amounts of color). Lower level pain intensity was assigned to numbers 1, 3, and 5(These contain small amounts of color). Higher and lower levels of pain intensity selection patterns were the same as Stewart's but the highest rating of pain was different. The highest pain intensity rating was given to the color red in this study instead of black as in Stewart's test. 2. University students and primary school students' ratings were not very difteferent. 3. Pain color circle reliability was $\alpha$=0.3468, Test - retest reliability was supported (t=0.02~0.97, p=0.337~0.988) 4. Differences in the rating of the pain intensity order were related to the subjects' age and sex, but not to religion. It was concluded that the pain color circle measurement tool is worth for further study as a research instrument with both Korean adult and child clients for validity and reliability.

  • PDF

디지털경사계를 사용한 체간재위치오류 검사의 신뢰도 분석 (Analysis of Intrarater and Interrater Reliability of Trunk Repositioning Error Test using a Portable Digital Inclinometer)

  • 장우남;이경보;염준우;황병용
    • The Journal of Korean Physical Therapy
    • /
    • 제25권4호
    • /
    • pp.210-216
    • /
    • 2013
  • Purpose: A cost effective tool for the clinical measurement of trunk reposition sense is clearly needed. This study was to analyze intrarater and interrater Reliability of trunk repositioning error (TRE) test which assesses trunk position sense using a portable digital inclinometer. Methods: Twenty four normal healthy subjects were recruited. TRE was measured using a portable digital inclinometer. A digital inclinometer (Acumar-ACU360; Lafayetter Instrument) with precision to $1^{\circ}$ was placed on skin over the spinous process from first to second thoracic vertebra (T1-T2) and secured with double-sided tape. TRE test during sitting forward and lateral flexion movement was assessed. When they reached a point approximately 50% of full trunk flexion range, the examiner instructed the subjects to stop and told them. This was the target position that they should try to reproduce exactly. Each subject performed six trials. Results: ICC (2,1) for intrarater reliability (with-day and between-day) of TRE test in sagittal and frontal plane of movement was 0.75 and 0.78 (excellent reliability). Interrater reliability was 0.66 in sagittal and 0.64, frontal plane (fair to good reliability). However, there were poor correlations between an average of TRE test in sagittal and frontal plane. Conclusion: TRE test using a portable digital inclinometer demonstrated good to excellent reliability. The device may be a cost effective clinical measurement for trunk reposition sense measurement.

장거리 영상기반 변위계측 시스템 검증 (Verification of Long-distance Vision-based Displacement Measurement System)

  • 김홍진;허석재;신승훈
    • 대한건축학회연합논문집
    • /
    • 제20권6호
    • /
    • pp.47-54
    • /
    • 2018
  • The purpose of this study is to verify the long - range measurement performance for practical field application of VDMS. The reliability of the VDMS was verified by comparison with the existing monitoring sensor, GPS, Accelerometer and LDS. It showed the ability to accurately measure the dynamic displacement by tracking a motion of free vibration of target. And using the PSD function of measured data, the results in the frequency domain were also analyzed. We judged that VDMS is able to identify the higher system mode and has sufficient reliability. Based on the reliability verification, we conducted tests for long-distance applicability for actual application of VDMS. The distance from the stationary target model structure was increased by 50m interval, and the maximum distance was set to 400m. From the distance of 150m, the image obtained by the commercial camcorder has an error in the analysis, so the measured displacement comparison was performed between the LDS and the refractor telescope measurement results. In the measurement results of the displacement area of VDMS, the data validity was deteriorated due to the data shift by the external force and the quality degradation of the enlarged image. However, even under the condition that the effectiveness of the displacement measurement data of VDMS is low, the first mode characteristic included in the free vibration of the object is clearly measured. If the influence from the external environment is controlled and stable data is collected, It is judged that reliability of long-distance VDMS can be secured.

소프트웨어 신뢰도 측정에서 고장률 비교 (Comparison of Failure Rates in Measuring Software Reliability)

  • 정혜정
    • 융합정보논문지
    • /
    • 제12권5호
    • /
    • pp.15-20
    • /
    • 2022
  • 본 연구는 소프트웨어 품질 특성인 기능적합성, 신뢰성, 사용성, 이식성, 유지보수성, 성능효율성, 보안성, 호환성 중에서 신뢰성에 대한 평가 방안을 연구하였다. 소프트웨어 품질 측정에 있어 신뢰성의 정량적 평가 방안을 제시한다. 본 연구는 소프트웨어 품질 특성 중 하나인 신뢰성 평가 중 성숙성에 포함되는 고장률을 측정하는 방법에 대해서 소개하고 고장 데이터의 형태에 따라 고장률이 어떻게 변화하는지에 대해 실험데이터를 가지고 연구한 내용이다. 소프트웨어 테스팅을 중심으로 매일의 고장 수를 중심으로 소프트웨어 신뢰성 성장 모델에 적용하여 고장률을 측정하여 고장 데이터의 형태에 따라 비교 분석하였다. 6일간의 테스트를 통해서 발견된 고장 시간을 중심으로 고장률을 측정하고 측정결과를 이용해서 국제표준 ISO/IEC 25023에서 제시하고 있는 고장률과 비교 하였으며 데이터 형태에 따라 적용방안을 검토하였다.

水質汚染物質의 共同試料分析調査 (Statistical Study on the Measurement Assurance Program in Environmental Pollution Measurement Activities -The Round-Robin Test about Water Pollution-)

  • 李載昌;申漢豊;李樂榮
    • Journal of the Korean Statistical Society
    • /
    • 제9권2호
    • /
    • pp.194-212
    • /
    • 1980
  • This report describes a preliminary study necessary to implement Measurement Assurance Program (MAP). The purpose of the study is to improve the measurement reliability of the laboratories which take environmental pollution measurement. We carried out the interlaboratory test or "Round-Robin" test program in which seven laboratories participated in order to obtain more reliable data about water pollution.pollution.

  • PDF

R&D 사업의 경제적 파급효과 측정 - 산업측정 신뢰도 제고사업을 중심으로 - (Evaluating the economic impact of R&D investments - Improvement of measurement reliability -)

  • 최승일;김진호;조문재;황인극
    • 한국산학기술학회논문지
    • /
    • 제8권4호
    • /
    • pp.946-951
    • /
    • 2007
  • 산업 발전을 지원하는 연구개발 관련 기관들은 R&D 사업에 대한 경제적 근거를 요구받고 있다. 본 연구에서는 R&D 사업의 경제적 파급효과 측정을 위해 예측적 비용편익 분석 방법을 사용한다. 가상현실평가모형으로 비용과 편익을 추정하여 주요 계량적 측도를 계산하는데, 한국표준과학연구원 산업측정 신뢰도 제고사업의 세부과제 중 정량적 평가가 용이한 3개 과제에 대하여 예측적 비용-편익 분석 방법을 적용한다.

  • PDF

엉덩관절 수술 환자에서 스마트폰을 이용한 관절가동범위 측정의 신뢰도 및 타당도 연구 (The Reliability and Validity of Hip Range of Motion Measurement using a Smart phone Operative Patient)

  • 박선욱;김명수;배효선;차용호
    • 대한물리의학회지
    • /
    • 제10권2호
    • /
    • pp.1-7
    • /
    • 2015
  • PURPOSE: The aims of this study were to assess the intra-tester and inter-tester reliability and validity of hip range of motion using a smart phone in hip operative patients. METHODS: Twenty-five patients (eight total hip arthroplasty and seventeen femur neck fracture) participated in this study. The range of motions in active and passive hip flexion, abduction and external rotation were measured with a goniometer and smart phone over two times by two observers. The intra-tester and inter-tester reliability were evaluated using the intraclass correlation coefficient (ICC2,1). The validity was measured by Pearson's correlation coefficient RESULTS: The intra-observer reliability was good in all measured items (ICC>0.78). The inter-observer reliability was high with ICC (>0.90). All correlation coefficients of smart phone and goniometer was greater than 0.85 and showed a significant positive correlation (p<0.01). CONCLUSION: The range of motion measurement with a smart phone showed acceptable reliability. Therefore, it could be convenient and have economical benefits to measure the range of motion of the hip joint using a smart phone.

Reliability and Validity of a Force-Sensing Resistor for the Measurement of Static Hindlimb Weight Distribution in Beagle Dogs

  • Heo, Su-Young;Jeong, Heejun;Jeong, Jaemin;Jeong, Seong Mok;Lee, HaeBeom
    • 한국임상수의학회지
    • /
    • 제35권5호
    • /
    • pp.206-210
    • /
    • 2018
  • The purpose of this study was to evaluate the reliability and validity of the Force-Sensing Resistor (FSR) for measurement of static hindlimb weight distribution in beagle dogs and to compare these results to a Digital Weighing Scale (DWS). Nine healthy beagle dogs were recruited for this study. Static weight distribution was evaluated four times at intervals of 5 days with each device and two observers to calculate the intra- and interobserver reliability. The intraclass correlation coefficient (ICC) values of the FSR for intraobserver reliability were moderate to good (0.74). The results for the DWS showed poor to moderate (0.56) ICC values for intraobserver reliability. The ICC values for interobserver reliability were 0.53 and 0.61 for FSR and DWS, respectively, indicating poor to moderate agreement. Our findings suggest that the Force-Sensing Resistor can be used to measure static weight distribution in veterinary medicine. However, caution should be taken when comparing measured values of static weight distribution obtained utilizing both the FSR and DWS due to their low positive correlation (R = 0.41, p < 0.01).

스마트폰 경사계를 사용한 엉덩관절 가동범위의 측정 신뢰도 연구 (Reliability Study of Hip Range of Motion Measurement by Smartphone Inclinometer)

  • 양회송;정찬주;유영대;배세현
    • 대한통합의학회지
    • /
    • 제4권2호
    • /
    • pp.89-96
    • /
    • 2016
  • Purpose : The purpose of this study was to evaluate inter-tester reliability and Intra-tester reliability about range of motion(ROM) measurement of hip joint with smartphone inclinometer. Method : Six observers performed goniometric and smartphone inclinometer measurements of various hip movements, including both active ROM for flexion, extension, external rotation, internal rotation. Measurements were performed in the right hip of fifty normal subjects. All measures were performed three times for evaluating reliability of observer. Inter- and intra-observer reliabilities were evaluated using the intraclass correlation coefficient(ICC). Result : The results were as follows, inter-observer reliability ICC value showed .948-.974 in smartphone inclinometer. And showed .781-.827 in goniometer. Intra-observer reliability ICC value showed .653-.992 in smartphone inclinometer. And showed .613-.854 in goniometer. Conclusion : Smartphone inclinometer are portable and widely available tools that are mostly reliable and valid for assessing active hip range of motion, with potential use when a goniometer is not available.