• 제목/요약/키워드: Reliability of Measurement

검색결과 2,408건 처리시간 0.03초

예비수학교사의 교직 적성·인성 검사에서 분할점수 변화에 따른 다양한 신뢰도 탐색 (Investigation of Various Reliability Indices of Pre-service Mathematics Teachers' Teaching Aptitude and Personality Test based on Setting Cut Scores)

  • 김성연
    • 한국수학교육학회지시리즈A:수학교육
    • /
    • 제57권1호
    • /
    • pp.55-74
    • /
    • 2018
  • The purpose of this study is first to examine the relative influence of each error source and to investigate the optimal measurement conditions to ensure satisfactory multiple reliability coefficients based on the teaching aptitude and personality test for pre-service teachers. Participants were 33 students enrolled in mathematics education in a graduate school of education located in the Seoul metropolitan area from 2013 to 2017. The main results were as follows. First, the estimated variance due to residual was highest, followed by nesting of items within domains, graduate students, interactions of graduate students with domains, and domains. Second, total 96 items, with 12 domains containing 8 items in each domain, with cut score of 598, and original 210 items, with 14 domains containing 15 items in each domain, with cut scores of 615 or 716 were optimal measurement conditions to reach acceptable reliability levels based on the joint consideration of dependability coefficients, cut score dependability coefficients, adjusted dependability coefficients, and standard errors of measurement. Third, larger deviations between the arithmetic mean and the cut score indicated higher reliability coefficients of the test results. Finally, this study suggests ways for practitioners to consider how to apply generalizability theory for criterion-referenced tests and how to develop future research based on limitations.

문화재 보존환경 간이 측정을 위한 온도지시카드 신뢰성 평가 (Reliability Assessment of Temperature Indicator for Simplified Measurement on Conservation Environment of Cultural Heritage)

  • 임보아;신은정;이선명
    • 보존과학연구
    • /
    • 통권31호
    • /
    • pp.59-68
    • /
    • 2010
  • Cultural heritages are damaged by surrounding several environmental factors. Main factors are temperature, humidity, light, atmosphere and indoor pollutant, organism, etc. Therefore, to prevent damage of cultural heritage from such environmental factor, conservation environment monitoring becomes more important. Indicator is one of the simple method for environment monitoring. It can be used without expensive and complex equipments. However, it should be performed scientific examination for application to cultural heritage. In this study, some Temperature Indicators were chosen and reliability assessment was carried out for application to cultural heritage. Brightness($L^*$) is selected for reliability assessment factor. As a result of lab test, Temperature Indicators were not influenced greatly in humidity change. When they were exposed to setting temperature, the color was changed in setting temperature area and ${\pm}2^{\circ}C$ part of setting temperature. Especially brightness value was high in setting temperature area. Also, Temperature Indicators were stabilized after about 16 minutes when were exposed to temperature difference of $10^{\circ}C$ and when temperature difference with exposure environment is smaller, stabilization time shortened. Therefore, it is a possible to confirm that selected Temperature Indicator is reliable product through measurement of color difference value and naked eye observation.

  • PDF

한국형 골관절염영향측정도구 개발 - 자료수집에서 1차 문항개발까지 - (Development of Korean Osteoarthritis Impact Measurement Scale(KAIMS) : from data collection to item development in the first study)

  • 이승주;김연주
    • 대한물리치료과학회지
    • /
    • 제19권1호
    • /
    • pp.17-25
    • /
    • 2012
  • Purpose : The aim of this study was from data collection to item development in the first study before developing a valid and reliable instrument reflecting Korean's own language expression and culture. Methods : The fist survey was 140 osteoarthritis(OA) patients in 2 Cites was studied from November to December 2009. Open-ended questionnaire was decided 39 items from the first open survey. Questionnaire on the Korean Osteoarthritis Impact Measurement Scale(KAIMS) was recruited 2 professors and 5 physical therapists. Second survey was applied to 133 OA patients. Results : OA patients's average age${\pm}$standard deviation was $66.08{\pm}11.10$ years. The internal consistency reliability of 3 items. As estimated by Cronbach's alpha coefficient(${\alpha}$), was high(range, 0.86~0.96). 0.43~0.91 ${\alpha}$ coefficient for the internal consistency reliability of item-each scale was also high. However, item-discriminant validity on 3 items was low(${\alpha}$, 0.92~0.97). The construct validity by factor analysis was a little low. Conclusion : This study revealed that we confirmed a generation for 39 items on KAIMS reflecting Korean's own language expression and culture. Also, those of reliability were a little high. And, we will have to study the last instrument development (3rd study) by more subjects in the future.

  • PDF

관성측정장치를 이용한 경추 가동범위 측정에 대한 고찰 (A review on measuring cervical range of motion using an inertial measurement unit)

  • 임주혁;김현호;박영재;박영배
    • 대한한의학회지
    • /
    • 제38권1호
    • /
    • pp.56-71
    • /
    • 2017
  • Objectives: The purpose of this study was to review the article using an IMU(Inertial Measurement Unit) for measuring the cervical range of motion and to evaluate the feasibility of using an IMU for measuring the cervical range of motion. Method: Scopus was used to search for the articles relating to the inclusion criteria. Which is measuring the cervical range of motion using an IMU. A total of 15 articles were selected through discussion. Degree and the reliability of the cervical range of motion and the validity of the data within the articles were extracted. Results: The measurement of the cervical range of motion using an IMU were $92.25^{\circ}$ to $138.2^{\circ}$, $122.4^{\circ}$ to $154.9^{\circ}$, $73.75^{\circ}$ to $93.1^{\circ}$ on the sagittal plane, transverse plane, and coronal plane respectively. 38 of the 43 values showed good reliability. They were larger than 0.75. 5 of the 43 values showed reliability less than 0.75. They were measured by smart phone. 16 of the 21 values showed good validity. The remaining 5 were measured by smart phone. The lower reliability and validity of smart phone were related to the protocol. The IMU can measure the coupling motion and may be used in various situations. Conclusion: The IMU may become a gold standard for measuring the cervical range of motion. The IMU measured not only the cervical range of motion but also the coupling motion. Furthermore, IMU may be used in various situations. Therefore, IMU must be considered a valuable measurement device.

3차원 바디 스캐너를 이용한 남성 상반신 인체측정 -직접측정과의 비교- (Upper Body Measurement of Men using 3D Body Scanner -Compared to Anthropometry-)

  • 백경자;이정란
    • 한국의류학회지
    • /
    • 제32권1호
    • /
    • pp.24-34
    • /
    • 2008
  • Three dimensional body scan technology is being targeted for utilization in the apparel industry. The purpose of this study was to test reliability of the body scan data targeting from 20 to 24 year old men by comparing 3DM, 3D body-scanning semi-auto measurement extraction method, Scanworx, 3D body-scanning auto measurement extraction method, and traditional anthropometric method. We found significant differences in 9 out of 25 items in upper body measurements using 3DM and 16 out of 25 items using Scanworx. In the range of difference value of scan measures, it showed 1 item in the absolute value of more than 40mm between two measuring methods, 3 items in 20 up to 40mm, and less than 20mm in other items. Overall, in height items, the numerical value of traditional measure was higher and in girth, width, depth items, 3D scan measure was higher. We found out that reliability of 3D measurements taken from whole body scans was different according to scanners, scanning softwares, programs, and subjects.

터빈유량계를 이용한 유량 측정 시스템의 최적 설계 (Optimal Design of Flow Measurement System Using Turbine Flowmeter)

  • 김홍탁;김부일
    • 한국전자통신학회논문지
    • /
    • 제13권1호
    • /
    • pp.77-84
    • /
    • 2018
  • 터빈유량계(Turbine flowmeter)는 유량 측정시 높은 정확도와 반복성을 위해 선택되지만 교정시의 표준 환경 조건과 현장에서의 환경 조건 차이로 다양한 측정 불확도 요인을 발생시킨다. 또한 교정된 측정값 외의 구간에서의 사용을 위해 신뢰성 높은 보간 기법(Interpolation method)이 필요하다. 따라서 본 논문에서는 유량 측정(Flow measurement) 신뢰성 향상을 위해 터빈유량계의 출력 신호의 정확한 측정과 교정된 결과값의 보간, 온도변화를 실시간 보정(correction)하는 장비를 설계 및 제작하고 성능 검증을 수행함으로 현장에서의 측정 신뢰도를 확보하였다.

한국 고등학생의 자살 보호요인 측정도구 개발 (Development of a Measurement of Suicidal Protection (MSP) for High School Students in Korea)

  • 박찬선;양숙자
    • 지역사회간호학회지
    • /
    • 제30권2호
    • /
    • pp.161-173
    • /
    • 2019
  • Purpose: This study was conducted to develop and test a measurement of the suicidal protection(MSP) for high school students in Korea. Methods: Thirty-four preliminary items were initially developed based on literature review and focus group interviews. Those items were evaluated by experts for content validity with 31 items yielded. For testing validity and reliability of the measurement, data were collected from 330 high school students in Korea. Results: The item analysis selected 26 items. One item was deleted additionally through the primary exploratory factor analysis. The final exploratory factor analysis yielded 26 items in six factors such as fear of suicide, self-esteem, emotion regulation, support from others, support from family, and school life, explaining 66.6% of the total variance of the suicidal protection for high school students in Korea. Convergent validity and discriminant validity were supported by construct reliability, average variance extracted estimate, and standardized regression weight. MSP scores were positively associated with economic status, academic record and suicidal ideation. Also, criterion validity was supported through a significant correlation with the Reason for Living Inventory for Adolescent. The Cronbach's ${\alpha}$ reliability coefficient was .93 for the overall measurement and .72~.86 for the six factors. Conclusion: The results show that MSP may be valid and reliable for assessing suicidal protection of high school students.

무선 센서를 활용한 요추 가동 범위의 실시간 3차원 측정 (Real-time 3-Dimensional Measurement of Lumbar Spine Range of Motion using a Wireless Sensor)

  • 정우혁;지혜미;박재현
    • 제어로봇시스템학회논문지
    • /
    • 제18권8호
    • /
    • pp.713-718
    • /
    • 2012
  • Lumber spine range of motion has been used to measure of physical and functional impairment by various tools from a ruler to 3D kinematic devices. However, pre-existing tools have problems in either movement or accuracy and reliability limitations. Accurate devices are limited by fixed space whereas simple devices are limited in measuring complex movements with less accuracy. In order to solve the location, movement and accuracy limitations at once, we have developed a novice measurement device equipped with accelerometer sensor and gyroscope sensor for getting three-dimensional information of motion. Furthermore, Kalman filter was applied to the algorithm to improve accuracy. In addition, RF wireless communication was added for the user to conveniently check measured data in real time. Finally, the measurement method was improved by considering the movement by a reference point. An experiment was conducted to test the accuracy and reliability of the device by conducting a test-retest reliability test. Further modification will be conducted to used the device in various joints range of motion in clinical settings in the future.

농업용트랙터 ROPS 시험의 신뢰성 향상을 위한 측정불확도 추정 (Measurement Uncertainty calculation for improving test reliability of Agricultural tractor ROPS Test)

  • 임류갑;강영선;김택진
    • 드라이브 ㆍ 컨트롤
    • /
    • 제20권1호
    • /
    • pp.34-40
    • /
    • 2023
  • The agricultural tractor ROPS test method according to OECD code 4 is a test to assess whether the driver's safety area can be secured when a tractor overturns, and reliability should be ensured. In this study, a model formula and procedure for calculating measurement uncertainty expressing reliability in the field of agricultural machinery testing were established according to the ISO/IEC Guide 98-3:2008. The characteristics of the ROPS test device were assessed and repeated tests were performed, and the were used as factors to calculate the measurement uncertainty. As a result of repeated tests, the accuracy was higher than 1.9 % in all load directions; thus, they were, applied to calculate the type A standard uncertainty. The final expanded uncertainty was calculated within the range of less than ± 7.76 kN of force and ± 6.96 mm of deformation in all load directions.

저추력 액체로켓엔진의 추력 측정 장치에 대한 연구 (The Study on the Thrust Measurement System of Low Thrust Liquid Rocket Engine)

  • 이동형;이양석;고영성;김유;김선진
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년도 제31회 추계학술대회논문집
    • /
    • pp.55-59
    • /
    • 2008
  • 액체로켓엔진의 성능 검증에 있어서 가장 큰 비중을 차지하는 것 중 하나는 정확한 추력 측정이다. 본 연구에서는 기존의 추력 측정 장치를 보완한 저추력 액체로켓엔진의 추력 측정 장치를 개발하여 작은 추력을 발생하는 로켓엔진의 보다 정확한 추력 측정을 가능하도록 하였다. 또한, 추력 측정 장치의 추력 측정 평가 시 고려되는 주요 인자들에 대한 연구를 수행하여 추력 측정 장치의 신뢰도 평가에 관한 기법 및 절차 수립의 기반을 마련하였다.

  • PDF