Incorporating Station Related Aging Failures in Bulk System Reliability Analysis

  • Billinton Roy;Yang Hua
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.4
    • /
    • pp.322-330
    • /
    • 2005
  • This paper proposes methods to incorporate station related aging failures in composite system reliability assessment. Aging failures of station components, such as circuit breakers and bus bars, are a major concern in composite power system planning and operation as an increasing number of station components approach the wear-out phase. This paper presents probabilistic models for circuit breakers involving aging failures and relevant evaluation techniques to examine the effects of station related aging outages. The technique developed to incorporate station related aging failures are illustrated by application to a small composite test system. The paper illustrates the effects of circuit breaker aging outages on bulk system reliability evaluation and examines the relative effects of variations in component age. System sensitivity analysis is illustrated by varying selected component parameters. The results show the implications of including component aging failure considerations in the overall analysis of a composite system.

A Study on Implementation of LV circuit analysis simulator for Reliability Evaluation (신뢰성 평가를 위한 LV 회로 분석시뮬레이터 구현에 관한 연구)

  • 장영건;조경환;박계서;최권희
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.602-609
    • /
    • 2000
  • This study is concerned with analysis and reliability evaluation of LV circuit in Cab Cubicle system which controls train to keep safety in High Speed Train. LV circuit is operated with diagnosis system as safety system. In this paper, we suggest a design and an implementation method to analyze LV circuit or trace fault area in LV circuit. This simulator uses 28 package modules and examines input and output by equations. So, user can trace where is fault area. The implemented system can be expected to be useful for long term test and evaluation of circuit in high speed train systems. We expect reduction to diagnosis area or repair time by this simulator.

  • PDF

Identifying Sensitive Components and Analyzing Reliability Process to Output Characteristic for an EAFD Circuit System According to Changes of Internal Component Values (전자식 점화안전장치 회로 시스템 내부 소자 변화에 따른 민감 소자 확인 및 출력 특성에 대한 신뢰성 분석 프로세스)

  • Lim, Tae Heung;Byun, Gangil;Jang, Seung-gyo;Back, Seungjun;Son, Youngkap;Choo, Hosung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.697-703
    • /
    • 2018
  • In this paper, we analyzed the operation of the ignition circuit for electronic arm and fire device(EAFD), and investigated the sensitive elements of the circuit system. For reliability analysis, the EAFD ignition circuit was modeled using the PSpice simulation tool, and the output results of the circuit were examined by changing the tolerance of each circuit element. Monte Carlo simulation was used by maintaining the values of the observed sensitive elements at ${\pm}10%$ of the original values and adjusting the values of the other components according to a random distribution. The histogram results of the output peak currents and pulse widths were represented by Weibull and Burr type XII function fittings in three cases(element values are +10 %, 0 %, -10 % of original). For the output peak currents, mean values were 1.0028, 1.0034, and 1.0050, where the variance values were calculated as 0.0398, 0.0396, and 0.0290 using the Weibull function fitting, respectively. For pulse widths, the mean values of 0.9475, 0.9907, and 1.0293 with the variance values of 0.0260, 0.0251, and 0.0238 were obtained using the Burr Type XII function fittings.

Convergence analysis technology for ship loading arm (선박용 로딩암에 적용할 수 있는 융합해석기술에 관한 연구)

  • Lee, Dae-Hee;Noh, Dae-Kyung;Lee, Geun-Ho;Park, Sung-Su;Jang, Joo-Sup
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.3
    • /
    • pp.258-268
    • /
    • 2017
  • In this study, we aim to converge a technology for analyzing the hydraulic circuit of a loading arm with an- other one for analyzing multi-body dynamics by utilizing analysis software SimulationX. Further, this study intends to overcome the limitations of the existing technology for analyzing a hydraulic circuit with a variation at the rotation center of the moving mass and the difficulty of incorporating the behavior in a gravity field. First, the specifications of the hydraulic circuit components were reflected in an analysis model to secure reliability. Hydraulic circuit modeling was then performed using a single analysis model with a verified reliability. Subsequently, the multi-body system (MBS) model of the loading arm was formed. Finally, the analysis model of the hydraulic circuit and the MBS model were converged to check if the circuit analysis result was exactly reflected in the MBS model. The convergence analysis model has development cost-saving effect because it is capable of predicting the dynamic behavior of an object without the prototype.

Field Reliability Analysis of S-Bond of AF Track Circuit for Automatic Train Control System (자동열차제어장치 AF궤도회로 S-BOND의 사용신뢰도 분석)

  • Choi, Kyu-Hyoung;Rho, Young-Whan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.2
    • /
    • pp.308-313
    • /
    • 2009
  • This paper presents a reliability analysis of S-bonds for AF track circuits, which detect train movement and transmit a speed control signal to the train. Field survey shows that S-bonds are exposed to very large vibrations transferred from rail, and suffer from frequent failures when they were installed on ballasted track. We collected the time-to-failure data of S-bonds from the maintenance field of Seoul metro line 2, and made a parametric approach to estimate the statistical distribution that fits the time-to-failure data. The analysis shows that S-bonds have time-to-failure characteristics described by Weibull distribution. The estimated shape parameter of Weibull distribution is 1.1, which means the distribution has constant failure rate characteristics like exponential distribution. The reliability function, hazard function, percentiles and mean lifetime are derived for maintenance support.

Performance verification and improvement of the frequency analysis unit for GIS Preventive & Diagnostic Monitoring System (GIS 예방진단시스템 주파수 분석장치 성능개선 및 검증)

  • Kim, Won-Gyu;Kim, Min-Soo;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.3
    • /
    • pp.485-491
    • /
    • 2015
  • This paper shows the design improvement and test model of FAU (Frequency Analysis Unit) in PDD (Partial Discharge Diagnosis system) for 800kV GIS (Gas Insulated Switchgear). We found some problems during operation of previous FAU, such as the aging of fiber-optic converter that can cause communication error, the malfunction of signal analysis circuit etc. And then we solved those problems by design improvement and verified the performance through type test. To monitor partial discharge, the performance of UHF sensor is important but the performance of frequency analysis unit is also very important. So we solved communication error, the malfunction of signal analysis circuit and then increased the operation reliability of FAU by improving fiber-optic converter and signal analysis circuit. Accredited testing laboratory carried out the performance verification test according to performance test criteria and procedure of reliability test standards, IEC-60225, 61000 and 60068 etc. We confirmed the test results which correspond with the performance test criteria.

Interrupting Test of Molded Case Circuit Breaker with Strong Driving Magnetic Force (강자계 구동형 460V/225A/50kA 배선용 차단기 대전력 차단성능평가)

  • Choi, Y.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.36-38
    • /
    • 2002
  • Low voltage circuit breakers which interrupt rapidly and raise the reliability of power supply are widly used in power distribution systems. In the paper, it was investigated how much Interrupting capability was improved by correcting the shape of the contact system in molded case circuit breaker(below MCCB), Prior to the interrupting testing, it was necessary for the optimum design to analyze magnetic forces on the contact system, generated by current and flux density. This paper presents both our compuational analysis and test results contact system in MCCB.

  • PDF

Development of 460V/225A/50㎄ Contact System in Current Limiting Molded Case Circuit Breakers

  • Park, Young-Kil;Park, Chan-Kyo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.3B no.4
    • /
    • pp.165-172
    • /
    • 2003
  • Low voltage circuit breakers are widely used in power distribution systems to interrupt fault current rapidly and to assure the reliability of the power supply. This paper is focused on understanding the interrupting capability, more specifically of the contacts and the arc runner, based on the shape of the contact system in the current molded case circuit breaker (hereafter MCCB). Moreover, in order to improve the interrupting capability of the circuit breaker, the estimation and analysis of the interrupting capability, based on the 3-D magnetic flux analysis, were developed. Furthermore, this paper also presents results of the estimation and analysis of the interrupting capability when applied to different model breakers. In addition, this paper analyzes the efficiency of the interrupting tests by forming false current paths consisting of a three-division cascade arc runner in the contact system. With regards to the interrupting test, there is a need to assure that the optimum design required to analyze the electromagnetic forces of the contact system generated by the current and flux density be present. Based on the results of this study, this paper presents both computational analysis and test results for the newly developed MCCB 460V/225A/50㎄ contact system.

An applicable RCM method for Track circuit equipment of AREX's Signalling System (공항철도 궤도회로장치에 대한 RCM 적용 방안)

  • Song, Mi-Ok;Lim, Sung-Soo;Lee, Chang-Hwan;Park, Seung-Keun
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1126-1131
    • /
    • 2008
  • In this paper we introduce an applicable RCM(Reliability centered maintenance) method for Track circuit equipment of AREX's Signalling System. AREX computerize all the process of FRACAS(Failure Reporting, Analysis and Corrective Action System)) by the Facility Management System of Integrated Information System. These datum were analysed and reproduced as the RAMS index value which can be used by maintenance staff for optimizing the maintenance method of the System.

  • PDF

Reliability Analysis of the railway signalling system which applied to the KNR ERP(Enterprise Resource Planning) Classification System (철도경영혁신 ERP 분류체계에 따른 철도신호시스템의 신뢰성 분석)

  • Cho, Rae-Hyuck;Park, Chae-Young;Min, Young-Hee;Yun, Hak-Sun
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.993-999
    • /
    • 2007
  • With the introduction of the RAMS(Reliability, Availability, Maintainability, Safety), the interest of the system assurance has been increased. First of all, fast-growing electronic circuit requires analyzing the failure rates, by dividing the signalling system more specifically. Since 2005, the K.N.R (Korean National Railway) has incorporated ERP(Enterprise Resource Planning) in order to establish the complete status as the top international comprise, therefore while ordering the project, it has established the classification system and then has been applying to ERP system in 2007. Due to the complex of the classification system, the reliability analysis of the signalling system was assessed with the limit of IXL ATP with On-board and wayside equipment. This paper assumed MTBF(Mean Time Between Failure), MTTR((Mean Time Between Repair) of total signalling system, by using the classification of ERP program.