• Title/Summary/Keyword: Release force

Search Result 193, Processing Time 0.024 seconds

Effect of Balance before and after Impact on the Velocity and Angle of Golf Club during Driver Swing (골프 드라이버 스윙 시 임팩트 전·후 신체 균형성이 클럽헤드의 속도와 각도에 미치는 영향)

  • Ryu, Ji-Seon;Kim, Tae-Sam
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.4
    • /
    • pp.411-420
    • /
    • 2011
  • The purpose of this investigation was to determine whether correlations exist between balance and impact velocity, angular position, and maximum velocity of a club during drive swing. Twelve skilled golfers were recruited in this study. They were asked to perform ten swing trials and two trials were selected for analysis. Balance parameters were calculated via the force platform while kinematic variables were determined by using the Qualisys system. The results of the present study demonstrated that the average of COP velocity was faster in the medio-lateral direction rather than the anterio-posterior direction. Also, left foot's COP velocity and free torque were greater than the right foot's before impact. The range of the right foot's COP in the anterio-posterior direction before impact were correlated with the club velocity and angular position at impact. There was a negative correlation between the left foot's COP velocity before the impact and the velocity at impact. Additionally, the range and RMS of the left foot's free torque affected on the club angular position at impact and the maximum velocity at release, respectively. Finally, a negative correlation existed between the range of the right foot's free torque after the impact and club's maximum velocity at release.

An Experimental Study of Smoke Movement in Tunnel Fires (터널화재시 연기 거동에 관한 실험적 연구)

  • Lee, Sung-Ryong;Kim, Choong-Ik;Ryou, Hong-Sun
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.121-126
    • /
    • 2001
  • In this study, reduced-scale experiments were conducted to understand smoke movements in tunnel fires with the natural ventilation. The 1/20 scale experiments were conducted under the Froude scaling since the smoke movement in tunnels is governed by buoyancy force. Six cases of experiments(pool diameter is 6.5cm, 7.3cm, 8.3cm, 10cm, l2.5cm and l5.4cm), in which vertical vents positioned 1m from the fire source symmetrically, were conducted in order to evaluate the effect of the vent on smoke movement. In case of heat release rate under 2MW, smoke front reached to the tunnel exit about 20 see delayed with ventilation and the smoke velocity was proportional to the power of the heat release rate. Temperature after the vent was lower than without vent. In case of l5.4cm pool, the temperature difference was about $50^{\circ}C$. It was confirmed that the thickness of smoke layer was maintained uniformly under the 35% height of tunnel through the visualized smoke flow by a laser sheet and the digital camcoder.

  • PDF

A Study of Hair Damage by Magic Straight Perm

  • Lim, Sun-Nye
    • Applied Microscopy
    • /
    • v.42 no.3
    • /
    • pp.129-135
    • /
    • 2012
  • In this study, the changes in hair quality before and after Magic straight perm have been evaluated through a hair damage measurement method. For this, a healthy high school student's (age18 years) wavy hair was selected and permed on the left and right sides. Then, the changes caused by physical methods which were applied during the fl at iron-based Magic straight perm were evaluated based on the hair damage measurement method before and after the Magic straight perm. According to the protein release test after the Magic straight perm, 1.26% in average and 0.14% was observed in Cool Magic straight perm sample. In a field emission scanning electron microscopy (FE-SEM) test, saw teeth-shaped partial desquamation of cuticle cells and impurities were observed in the warm-treated hair sample. In atomic force microscope (AFM), line-profile is a method to represent roughness data on hair. According to analysis on 3-dimensional (3D) images, the hair with Cool Magic straight perm was lower than the hair with Warm Magic perm in terms of the color change of 3D images. In addition, vertical changes were observed in the hair with Cool Magic perm. As a result, irregular surface roughness was observed. This study proposed a method to minimize hair damage by cooling down the heat with the cool hair straightener as soon as the Warm Magic was finished.

The Development of Pyrotechnically Releasable Mechanical Linking Device Using Pressure Cartridge (압력카트리지를 이용한 파이로 분리장치 개발)

  • Kim, Dong-Jin;Lee, Yeung-Jo;Ko, Young-Kyun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.340-343
    • /
    • 2011
  • Explosive bolts are reliable and efficient mechanical fastening devices having the special feature of a built-in release. The disadvantage of explosive bolt lies in that it is based on the high explosive effect of a pyrotechnic charge. The aim of the present work is to propose a pyrotechnically releasable mechanical linking device for two mechanical elements that does not suffer from such drawbacks. The pyro-lock using the pressure cartridge has the release characteristic without fragmentation and minimum pyro-shock. The present work is focused on the design, the interpretation of structure, the separation mechanism, separation force, and the results of various tests.

  • PDF

Kinematic Analysis of Baseball Throw after 15 Weeks of Class (15주 야구 수업을 통한 던지기 동작의 운동학적 변인 변화 분석)

  • Chun, Young-Jin;Shin, In-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.1
    • /
    • pp.1-7
    • /
    • 2012
  • The purpose of this study was to investigate the pattern change of throwing in baseball after 15 weeks of participation in baseball class, by examining ball speed, trunk and upper body angles. The comparison was with 6 university students that haven't had any experience in baseball. 8 infra red cameras and 2 force platforms were used to collect the data. First, there was an increase in the speed of the ball after the class. Second, there was no significant difference in the allocated phases during the throw before and after class. Third, the release point was lower and more in front. Forth, there was an increase in the knee flexion at the left foot landing and release point. Finally, there was an increase in the maximum shoulder external rotation and pelvis angle. It is recommended that the coordination between the segments should be investigated to improve our understanding of the learning of throwing in future research.

Oral Mucosal Adhesive Tablets of Omeprazole (오메프라졸 구강점막 부착정제에 관한 연구)

  • Jung, Jae-Hee;Choi, Han-Gon;Park, Sun-Joo;Ryu, Jei-Man;Yoon, Sung-June
    • Journal of Pharmaceutical Investigation
    • /
    • v.27 no.2
    • /
    • pp.133-137
    • /
    • 1997
  • Buccal absorption test of omeprazole in human was performed to determine the permeability of the drug molecule through oral mucous membrane. Oral mucosal adhesive tablets of omeprazole were prepared by compressing the omeprazole with a mixture of sodium alginate and hydroxypropylmethyl cellulose (HPMC) as bioadhesive polymers, magnesium oxide (MgO) as a stabilizer and sodium carboxymethyl cellulose (Na CMC) or cros-carmellose sodium (Ac-Di-Sol) as disintegrants. The bioadhesive force, stability in saliva and release characteristics of the tablets were evaluated. Omeprazole was absorbed about 23% in 15 min through human buccal mucous membrane. Furthermore, omeprazole was stable in saliva for more than 8 hrs when MgO was added to the tablet as the amount of 2.5 fold of omeprazole. The release rate of omeprazole was increased with increasing the amount of sodium alginate in the tablet. From these results, it is suggested that tablets composed of [omeprazole/HPMC/sodium alginate/MgO/Ac-Di-Sol and/or Na CMC (20/6/24/50/10) (mg/tablet)] are potential candidate for buccal drug delivery system.

  • PDF

Assessment Corrosion and Bioactive Behavior of Bioglass Coating on Co-Cr-Mo Alloy By Electrophoretic Deposition For Biomedical Applications

  • Areege K. Abed;Ali. M. Mustafa;Ali M. Resen
    • Corrosion Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.179-194
    • /
    • 2024
  • A layer-by-layer coating was produced using electrophoretic deposition for a HA/Al2O3 coating layer and a bioglass coating layer on Co-Cr-Mo alloy with a roughness of 0.5 ㎛ (400 emery paper SiC). The corrosion behaviour was analyzed by assessing the coating layers' exceptional corrosion resistance, which outperformed the substrate. Cr ion release test using AAS was carried out, indicating that factional graded coating inhibited ion release from the uncoated substrate to coated sample. The porosity was expressed as a percentage, representing the extent of imperfections on the surface of all coatings. These imperfections fell within an acceptable range of 1% to 3%. The roughness of the coated surface was measured using atomic force microscopy, which revealed an excellent roughness value of 3.32 nm. Tape test technique for adhesion revealed that the removal area of the substrate coating layer varied by 11.92%. X-ray diffraction analysis confirmed the presence of all coating material peaks and verified phases of the deposited coating layers. These findings provided evidence that the coating composition remains unaffected by the electrophoretic deposition process. The bioactivity was assessed by immersion in a simulated bodily fluid, which revealed the formation of HCA during a period of 5 days.

Experiment and Analysis on Impact of Tapered Double Cantilever Beam with Aluminum Alloy (알루미늄 합금으로 된 경사진 이중외팔보의 충돌에 대한 실험 및 해석)

  • Gao, Teng;Cho, J.U.;Cheon, Seong S.
    • Composites Research
    • /
    • v.27 no.2
    • /
    • pp.72-76
    • /
    • 2014
  • This study is investigated by experiments and analyses at rates of 2.5m/s, 7.5m/s and 12.5m/s on the impact of tapered double cantilever beam specimens with aluminium alloy. It aims to examine the mechanical property of aluminum alloy by evaluating energy release rate and equivalent stress happened at the bonded part of specimen. Because bonding force remains after the separation of specimen, the energy release rate at the bonded part becomes highest. As crack propagates and the high stress happens at the end of the bonded part, the maximum equivalent stress becomes higher at the last stage, regardless of impact rate. These results of experiments and analyses are the data necessary to develop the safe design of composite material to prevent crack propagation due to impact.

In vitro and in vivo studies on theophylline mucoadhesive drug delivery system

  • Bandyopadhyay, AK;Perumal, P
    • Advances in Traditional Medicine
    • /
    • v.7 no.1
    • /
    • pp.51-64
    • /
    • 2007
  • Mucus is an aqueous gel complex with a constitution of about 95% water, high molecular weight glycoprotein (mucin), lipid, salts etc. Mucus appears to represent a significant barrier to the absorption of some compounds. Natural mucoadhesive agent was isolated and purified from the aqueous extract of the seeds of prosopis pallida (PP). Formulated tablet with the isolated material by wet granulation method. Some natural edible substances are in consideration for candidates as mucoadhesive agents to claim more effective controlled drug delivery as an alternative to the currently used synthetic mucoadhesive polymers. Subjected the materials obtained from natural source i.e. PP and standard synthetic substance, sodium carboxymethyl cellulose for evaluation of mucoadhesive property by various in vitro and in vivo methods. Through standard dissolution test and a model developed with rabbit, evaluated in vitro controlled release and bioadhesive property of theophylline formulation. Mucoadhesive agent obtained from PP showed good mucoadhesive potential in the demonstrated in vitro and in viνo models. The results suggest that the mucoadhesive agent showed controlled release properties by their application, substantially. In order to assess the gastrointestinal transit time in vivo, a radio opaque X-ray study performed in healthy rabbit testing the same controlled release formulation with and without bioadhesive polymer. Plasma levels of theophylline determined by the HPLC method and those allowed correlations to the in vitro mucoadhesive study results. Better correlation found between the results in different models. PP may acts as a better natural mucoadhesive agent in the extended drug delivery system.

Preparation of Poloxamer-based Hydrogels Using Electron Beam and Their Evaluation for Buccal Mucoadhesive Drug Delivery (전자빔을 이용한 폴록사머 하이드로젤의 제조 및 구강 점막부착성 약물전달을 위한 특성 분석)

  • Baek, Eun-Jung;Shin, Baek-Ki;Nho, Young-Chang;Lim, Youn-Mook;Park, Jong-Seok;Park, Jeong-Sook;Huh, Kang-Moo
    • Polymer(Korea)
    • /
    • v.36 no.2
    • /
    • pp.182-189
    • /
    • 2012
  • In this study, poloxamer hydrogels were prepared by electron beam irradiation and evaluated for potential application as a buccal mucoadhesive drug delivery system. Poloxamer, one of typical thermoresponsive polymers, was modified to have vinyl end groups for crosslinking reaction, and its hydrogels were fabricated by irradiation crosslinking reaction. Carbopol as a mucoadhesive polymeric additive was introduced to improve the mucoadhesive property of the hydrogels and its effect on the mucoadhesion and drug release properties was investigated. The results showed that the end group modification of poloxamer and the addition of carbopol improved mucoadhesive force and mechanical properties and led to a sustained drug release behavior.