• Title/Summary/Keyword: Release force

Search Result 191, Processing Time 0.024 seconds

Effect of Frictional Resistance Force on a Liquid Pool Spreading Model with Continuous and Instantaneous Release (마찰저항이 연속누출과 순간누출을 가지는 액체 풀의 확산에 미치는 영향에 대한 해석적 연구)

  • Kim, Tae Hoon;Choi, Byung-Il;Kim, Myungbae;Do, Kyu Hyung;Han, Yong-Shik
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.24 no.6
    • /
    • pp.487-494
    • /
    • 2013
  • In this study, solutions for a liquid pool spreading model with continuous and instantaneous release are discussed based on the model used in the FERC's report. The effects of the release time on the liquid pool volume and radius are investigated for the continuous release. For the continuous release with the frictional resistance force in the liquid pool spreading model, the vaporization time decreases as the release time increases. On the other hand, for the continuous release without the frictional resistance force in the liquid pool spreading model, the vaporization time increases as the release time increases. These phenomena are deeply related to the pool radius. In addition, the effects of the initial pool radius for the instantaneous release in the liquid pool spreading model are discussed. For the case with the frictional resistance force in the liquid pool spreading model, as reducing release time in the model with the frictional resistance force for the continuous release, the solution for a continuous release approaches to that for an instantaneous release. On the contrary to this, the pool volume and radius for the instantaneous release without the frictional resistance force are totally different from those for the continuous release without the frictional resistance force.

Experimentally Evaluation of a Liquid Pool Spreading Model with Continuous Release (연속누출을 가지는 액체 풀 확산 모델의 실험적 평가)

  • KIM, TAEHOON;DO, KYU HYUNG;KIM, MYUNGBAE;HAN, YONG-SHIK;CHOI, BYUNG-IL
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.26 no.6
    • /
    • pp.659-665
    • /
    • 2015
  • In this study, an experimental investigation is performed for evaluation of a liquid pool spreading model with continuous release. The model considered in this study was developed based on a concept which means that the liquid pool spreading is governed by a balance between an inertia force from gravity and a frictional force from friction with the ground under the whole base of the liquid pool. For evaluation of the model, experimental study is performed. Experimental apparatus is setup for measuring release rate, spreading velocity, and evaporation rate from a liquid pool. The experimental results are compared with results from the model. By applying release and evaporation rates obtained from experiments to solving the model, liquid pool radius variation according to time can be obtained. For evaluation of an effect of friction force in the spreading model, results obtained from the models with and without the friction force are compared with those obtained from the experiments. As a result, it is shown that there exists a large deviation between the results obtained from the model without the friction force and the experimental results. On the other hand, the tendency of liquid pool radius variation according to time is similar between the results obtained from the model without the friction force and the experimental results.

Launch and On-orbit Environment Verification Test of Flight Model of Hinge Driving Type Holding and Release Mechanism based on the Burn Wire Release (열선분리방식을 이용한 힌지구동형 구속분리장치 비행모델의 발사 및 궤도환경 검증시험)

  • Lee, Myeong-Jae;Lee, Yong-Keun;Kang, Suk-Joo;Oh, Hyun-Ung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.3
    • /
    • pp.274-280
    • /
    • 2016
  • Hinge driving type holding and release mechanism based on the burn wire release for application of cubesat is main payload of STEP Cube Lab. (Cube Laboratory for Space Technology Experimental Project) to be launched at 2015. It has high constraint force, low shock level as well as surmounting drawbacks of conventional nichrome burn wire release method that has relatively low constraint force and system complexity for application of multi-deployable systems. In this paper, we have proposed a flight model of holding and release mechanism for the verification of the constraint force and deployment status signal acquisition. To validate the effectiveness of the flight model, launch and on-orbit environment verification test have been performed.

Development of Flight Model of Segmented Nut Type Holding and Release Mechanism Using Burn Wire Cutting Method for On-orbit Verification (열선절단형 분리너트식 구속분리장치의 궤도검증을 위한 비행모델 개발)

  • Lee, Myeong-Jae;Lee, Yong-Keun;Kang, Suk-Joo;Oh, Hyun-Ung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.911-915
    • /
    • 2014
  • Pyrotechnic devices are widely used for space appendages. However, a cube satellite requirements do not permit the use of explosive pyrotechnic device. A nichrome burn wire release has typically been used for holding and release of deployable appendages of the cube satellite due to its simplicity and low cost. However, relatively low mechanical constraint force and system complexity for application of multi-deployable systems are disadvantages of the conventional mechanism. To overcome these drawbacks, we have developed a segmented nut type holding and release mechanism based on the nichrome burn wire release. The great advantages of the mechanism are much lower shock level and larger constraint force than the conventional mechanism using pyro. Flight model for on-orbit verification was developed and verified through release function test, vibration test and thermal vacuum test.

  • PDF

The Study on Countermeasures of Electromagnetic Force by Three Phase Short-Circuit Test of Underground Transmission Cable (송전케이블 삼상단락 실증시험을 통한 전자력 대책방안 연구)

  • Kang, Ji-Won;Park, Hung-Sok;Yoon, Jong-Keon;Kim, Yang-Sang;Hong, Dong-Suk;Chang, Woo-Seog
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2342-2348
    • /
    • 2009
  • Even though underground transmission cable is an essential transmission method to supply stable power for downtown and population center, the interaction of electromagnetic force by fault current is very large comparing to overhead transmission line due to restricted installation space such as tunnel, and close consideration is required for it. This paper presents countermeasures to reduce and release the effect of electromagnetic force with rope binding and installation of spacer and describes its efficacy through three phase short-circuit test, which will be utilized as basic materials for improvement and development of cleat, hanger, etc. to reduce and release effect of electromagnetic force in the future.

Effect of Kinetic Degrees of Freedom of the Fingers on the Task Performance during Force Production and Release: Archery Shooting-like Action

  • Kim, Kitae;Xu, Dayuan;Park, Jaebum
    • Korean Journal of Applied Biomechanics
    • /
    • v.27 no.2
    • /
    • pp.117-124
    • /
    • 2017
  • Objective: The purpose of this study was to examine the effect of changes in degrees of freedom of the fingers (i.e., the number of the fingers involved in tasks) on the task performance during force production and releasing task. Method: Eight right-handed young men (age: $29.63{\pm}3.02yr$, height: $1.73{\pm}0.04m$, weight: $70.25{\pm}9.05kg$) participated in this study. The subjects were required to press the transducers with three combinations of fingers, including the index-middle (IM), index-middle-ring (IMR), and index-middle-ring-little (IMRL). During the trials, they were instructed to maintain a steady-state level of both normal and tangential forces within the first 5 sec. After the first 5 sec, the subjects were instructed to release the fingers on the transducers as quickly as possible at a self-selected manner within the next 5 sec, resulting in zero force at the end. Customized MATLAB codes (MathWorks Inc., Natick, MA, USA) were written for data analysis. The following variables were quantified: 1) finger force sharing pattern, 2) root mean square error (RMSE) of force to the target force in three axes at the aiming phase, 3) the time duration of the release phase (release time), and 4) the accuracy and precision indexes of the virtual firing position. Results: The RMSE was decreased with the number of fingers increased in both normal and tangential forces at the steady-state phase. The precision index was smaller (more precise) in the IMR condition than in the IM condition, while no significant difference in the accuracy index was observed between the conditions. In addition, no significant difference in release time was found between the conditions. Conclusion: The study provides evidence that the increased number of fingers resulted in better error compensation at the aiming phase and performed a more constant shooting (i.e., smaller precision index). However, the increased number of fingers did not affect the release time, which may influence the consistency of terminal performance. Thus, the number of fingers led to positive results for the current task.

Effects of Polymer-Drug Interactions on Drug Release from Sustained Release Tablets (서방정으로부터의 약물 용출에 대한 고분자-약물 상호작용의 영향)

  • Kim, Haeng-Ja;Lee, Seung-Jin
    • Journal of Pharmaceutical Investigation
    • /
    • v.26 no.2
    • /
    • pp.119-124
    • /
    • 1996
  • To develop oral controlled release dosage forms, ionic interactions between polymers and drugs were evaluated. Hydroxypropylmethyl cellulose and carboxymethylene were used as model nonionic and ionic polymers, respectively. 5-fluorouracil, propranolol-HCl and sodium salicylate were selected as model nonionic, cationic and anionic, respectively. Polymer-drug mixtures were compressed into tablets and drug release kinetics from these tablets were determined. Drug release from the tablets made of the nonionic polymer was not affected by the charge of drugs, rather, was regulated by the solubility of drugs in different pH releasing media. However, drug release kinetics were significantly affected when drug-polymer ionic interactions exist. Enhanced drug release was observed from anionic drug-anionic polymer tablets due to ionic repulsion, whereas drug release was retarded in cationic drug-anionic polymer tablets owing to ionic attractive force. Therefore, the results suggested that the polymer-drug interactions are important factors in designing controlled release dosage forms.

  • PDF

The Biomechanical Study on the Timings of Tkatchev Motion in Horizontal Bar (중고등학교 우수 선수의 철봉 Tkatchev 기술의 순간 동작 시점에 관한 운동역학적 연구)

  • Lim, Kyu-Chan
    • Korean Journal of Applied Biomechanics
    • /
    • v.29 no.2
    • /
    • pp.121-128
    • /
    • 2019
  • Objective: The aim of this study was to examine the relation between swing phase and airborne phase of Tkatchev motion which was successfully performed with following motion by excellent middle and high school athletes in horizontal bar. Method: The subjects for this study were 8 male middle and high school top athletes. After their Tkatchev motions were filmed by two digital highspeed camcorders setting in 90 frames/sec at the 44th National Gymnastics against Cities and Provinces, the % lapse time lapse time of each instant, inferred maximum force acting on horizontal bar, and other kinematical variables were calculated through DLT method. After the relations among the % lapse times of each instants of downswing-start, downswing-finish, whipswing-finish, release, peak-height, and lapse time of regrasp, the relation among maximum force acting on bar, % lapse time, peak height, and the relation between % lapse time and release height were examined, the biomechanical timing characteristics of Tkatchev motion were as follows. Results: Firstly, it was revealed that the whole lapse time was $1.62{\pm}.06s$ and the correlation between the % lapse time of downswing-start and % lapse time of release was .819. Secondly, it was revealed that the pattern of COG path was shifted forwardly and tilted 11 clockwise from origin. Thirdly, it was revealed that maximum force acting on bar was inferred in $2,283{\pm}425N$ ($4.7{\pm}.6BW$) and the correlation between maximum force and peak height was r = .893. Lastly, it was revealed that the horizontal and vertical component of body COG velocity was $-2.14{\pm}.29m/s$, $2.70{\pm}.43m/s$ respectively, release height was $.49{\pm}.12m$, and shoulder angle was $139{\pm}5deg$, and that the later the % lapse time of release, the higher the release height (r = .935). Conclusion: It is desired that the gymnastic athletes should delay the downswing-start near the horizontal plane on $2^{nd}$ quadrant because the later the % lapse time of downswing, the higher the release height. After all the higher release height could ensure the athletes to regrasp the bar safely, the athletes should exercise to make downswing-start delay.

Mucoadhesion, Swelling and Drug Release Characteristics of Hydroxypropylcellulose/Carbopol Solid Dispersions (히드록시프로필셀룰로오스/카르보폴 고체분산체의 점막부착성과 팽윤 및 약물방출특성)

  • Kim, Sang-Heon;Yang, Su-Geun;Shin, Dong-Sun;Lee, Min-Suk;Choi, Young-Wook
    • Journal of Pharmaceutical Investigation
    • /
    • v.24 no.3
    • /
    • pp.155-165
    • /
    • 1994
  • Some mucoadhesive polymers such as hydroxypropylcelluose (HPC) and carbopol-934 (CP) have been employed for the preparation of mucoadhesive polymeric systems, and their physical properties including mucoadhesion, swelling, and drug release were evaluated. A new simple experimental technique that can quantitatively measure the bioadhesive properties of various polymeric systems has been developed by the methods of detachment force test. As the polymeric systems, the discs of freeze-dried HPC/CP solid dispersions were prepared. The mucosa used in these tests were upper, middle, and lower parts of small intestine of male rats weighing $300{\sim}350\;g$. Detachment forces were increased as the mole fraction of CP increased in discs of HPC/CP solid dispersions. In the points of intestinal site dependence of mucoadhesion, the solid dispersions revealed non-specific mucoadhesion to the intestine. Swelling and drug release characteristics of mucoadhesive polymeric systems were studied extensively to find out the feasibility for the oral controlled delivery systems. Swelling ratio, expressed as the final height/initial height, has been determined in various pH buffer solutions. Hydrochlorothiazide (HCT) was employed as a model drug for release study. Apparent swelling and drug release rate constants, $K_s$ and $K_r$ respectively, were obtained from the square-root time plot of either swelling ratio or released amount of drug, particularly for the time periods before reaching the equilibrium. As a result, the swelling ratio of HPC/CP solid dispersions was increased as the weight percentage of CP increased. Similarly, the release of HCT from the solid dispersions was dependent on pH changes and CP contents, resulted in the slower release of HCT with the increases of pH and CP contents.

  • PDF