• Title/Summary/Keyword: Release Process

Search Result 1,008, Processing Time 0.041 seconds

Microbial Inhibition Test of Sustained-Release Chlorine Dioxide Gas Freshness Retaining Agent

  • Choe, Yoowha
    • International Journal of Advanced Culture Technology
    • /
    • v.8 no.3
    • /
    • pp.211-215
    • /
    • 2020
  • Currently, most of the chlorine dioxide gas is processed at the beginning of storage or distribution. It has the disadvantage of not being able to continuously process gas since there is no system that can continuously process it during the distribution process. Therefore, in order to minimize changes in freshness and quality during the distribution process of agrifood, there is a need for a sustained-release chlorine dioxide gas treatment technology that can be continuously released. Therefore, in this study, the film to be used was examined so that the chlorine dioxide gas can be continuously released for a certain period of time, the concentration of the reactant and the viscosity at the time of the reaction were determined, and a chlorine dioxide gas gel pack was manufactured using this optimal condition. In addition, the gel pack was used to measure the amount of chlorine dioxide gas released and the sterilization effect of food poisoning bacteria.

A free standing metal structures for MEMS switches (MEMS switch 응용을 위한 free standing 금속 구조물에 관한 연구)

  • Hwang, Hyun-Suk;Kim, Eung-Kwon;Kang, Hyun-Il;Lee, Kyu-Il;Lee, Tae-Yong;Song, Joon-Tae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.187-188
    • /
    • 2005
  • In this paper, big free standing metal structures for electrostatic MEMS switches are easily fabricated using photoresist sacrificial layer. The entire process sequence, through the removal of the sacrificial layer, is kept below 150 $^{\circ}C$ to avoid curing problem of photoresist sacrificial layer. Metal structure is fabricated by thermal evaporator and a self test electrode is fabricated underlying metal suspended structure for testing by electrostatic force. The new wet release process is considered using methanol rinse, general wet release process cause stiction problem by capillary force during drying, and the yield is dramatically improved than previous wet release process using DI water rinse. The fabrication becomes much simpler and cheaper with use of a photoresist sacrificial layer.

  • PDF

The Comparative Study of Software Optimal Release Time Based on Intensity Function property (강도함수 특성에 근거한 소프트웨어 최적 방출시기에 관한 비교 연구)

  • Kim, Hee-Cheul;Park, Hyoung-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.4
    • /
    • pp.1239-1247
    • /
    • 2010
  • In this paper, we were researched decision problem called an optimal release policies after testing a software system in development phase and transferring it to the user. The applied model of release time exploited infinite failure non-homogeneous Poisson process This infinite failure non-homogeneous Poisson process is a model which reflects the possibility of introducing new faults when correcting or modifying the software. The intensity function used Gompertz, Preto and Log-logstic pattern which has the efficient various property. Thus, optimal software release policies which minimize a total average software cost of development and maintenance under the constraint of satisfying a software reliability requirement becomes an optimal release policies. In a numerical example, after trend test applied and estimated the parameters using maximum likelihood estimation of inter-failure time data, estimated software optimal release time.

Comparison of Biological Phosphorus Removal Characteristics between A/O and A2/O Process (A/O 및 A2/O공정의 생물학적 인제거 특성비교)

  • Kim, Kwang-Soo;Seo, Gyu-Tae;Lee, Kyung-Ho;Kim, Nag-Ju
    • Journal of Korean Society on Water Environment
    • /
    • v.18 no.2
    • /
    • pp.123-130
    • /
    • 2002
  • Bench scale experiments were carried out with two biological nutrient removal(BNR) units, A/O and $A^2O$ processes, to investigate the behavior of phosphorus in the system and to compare the characteristics of phosphorus removal in two BNR processes. To achieve this goal, COD/T-P and COD/TKN ratios of the influent was varied in the range of 23~64 and 5~24, respectively. In A/O process, influent COD/T-P ratio should be kept higher than 44mg/L to meet the final effluent T-P concentration lower than 1mg/L and in $A^2/O$ process, influent COD/T-P and COD/TKN ratios higher than 56 and 10, respectively, were required for good phosphorus release and uptake with no influence of nitrate nitrogen in return sludge. At this conditions, the rate of phosphorus release in the anaerobic basin should be kept higher than 0.1 kg S-P/kg MLVSS d In A/O process, the phosphorus content of anaerobic and aerobic sludges was increased as SRT of total system was becoming longer resulting in decreasing the difference of phosphorus content between two sludges while phosphorus release in anaerobic basin and phosphorus uptake in aerobic basin was not incident. In $A^2/O$ process, the phosphorus content of anaerobic and aerobic sludges were not increased with higher SRT of total system due to the relatively high nitrate concentration in return sludge. However, the difference of phosphorus content between anaerobic and aerobic sludges was incident when phosphorus release and uptake was observed.

Heterogeneity of the SR-dependent Inward $Na^+-Ca^{2+}$ Exchange Current in the Heavily $Ca^{2+}-buffered$ Rat Ventricular Myocytes

  • Yoon, Kyung-Bong;Ahn, Sung-Wan;Ko, Chang-Mann
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.8 no.2
    • /
    • pp.101-110
    • /
    • 2004
  • Voltage-sensitive release mechanism was pharmacologically dissected from the $Ca^{2+}-induced\;Ca^{2+}\;release$ in the SR $Ca^{2+}$ release in the rat ventricular myocytes patch-clamped in a whole-cell mode. SR $Ca^{2+}$ release process was monitored by using forward-mode $Na^+-Ca^{2+}$ exchange after restriction of the interactions between $Ca^{2+}$ from SR and $Na^+-Ca^{2+}$ exchange within micro-domains with heavy cytosolic $Ca^{2+}$ buffering with 10 mM BAPTA. During stimulation every 10 s with a pulse roughly mimicking action potential, the initial outward current gradually turned into a huge inward current of $-12.9{\pm}0.5\;pA/pF$. From the inward current, two different inward $I_{NCX}s$ were identified. One was $10\;{\mu}M$ ryanodine-sensitive, constituting $14.2{\pm}2.3%$. It was completely blocked by $CdCl_2$ (0.1 mM and 0.5 mM) and by $Na^+-depletion$. The other was identified by 5 mM $NiCl_2$ after suppression of $I_{CaL}$ and ryanodine receptor, constituting $14.8{\pm}1.6%$. This latter was blocked by either 10 mM caffeine-induced SR $Ca^{2+}-depletion$ or 1 mM tetracaine. IV-relationships illustrated that the latter was activated until the peak in $30{\sim}35\;mV$ lower voltages than the former. Overall, it was concluded that the SR $Ca^{2+}$ release process in the rat ventricular myocytes is mediated by the voltage-sensitive release mechanism in addition to the $Ca^{2+}-induced-Ca^{2+}\;release$.

Effect of Curing and Compression Process on the Drug Release of Coated Ion-Exchange Resin Complexes

  • Jeong, Seong-Hoon;Wang, Hun-Sik;Koo, Ja-Seong;Choi, Eun-Joo;Park, Ki-Nam
    • Journal of Pharmaceutical Investigation
    • /
    • v.41 no.2
    • /
    • pp.67-73
    • /
    • 2011
  • Ion exchange resins can be one of the good carriers for sustained drug release. However, the sustained release may not be enough only with themselves and hence film coating with rate controlling polymers can be applied to have a further effect on the drug release. Due to the environmental and economic issues of organic solvent for the polymer coating, aqueous polymeric systems were selected to develop dosage forms. Among the many aqueous polymeric dispersions for the film coating, EC (ethylcellulose) based polymers such as Aquacoat$^{(R)}$ ECD and Surelease$^{(R)}$ were evaluated.A fluid-bed coating was applied as a processing method. The drug release rate was quite dependent on the coating level so the release rate could be modified easily by changing different levels of the coating. The drug release rate in the Aquacoat$^{(R)}$ coated resin particles was strongly dependent on curing, which is a thermal treatment to make homogeneous films and circumvent drug release changes during storage. After dissolution test using the compressed tablets in which the coated resin particles are contained, inhomogeneous coating and even pores could be observed showing that the mechanical properties of EC were not resistant to granulation and compaction process. However, when tablets were prepared in different batches, the release profiles were almost identical showing the feasibility of the coated resin particle as incorporated into the tablet formulation.

Effects of Several Cardioactive Agents on the Regenerative $Ca^{++}$ Release in the Mechanically Disrupted Cardiac cells (심근에 작용하는 수종 약물이 쥐의 심근의 'Regenerative $Ca^{++}$ Release'에 미치는 영향)

  • Kang, Doo-Hee;Lee, Joong-Woo
    • The Korean Journal of Physiology
    • /
    • v.11 no.2
    • /
    • pp.9-16
    • /
    • 1977
  • The present experiment was conducted to see whether or not several cardioactive agents influence the 'regenerative $Ca^{++}$ release' in the mechanically disrupted cardiac cells. The mechanically disrupted cardiac cells were prepared by the method of Kerrick and Best from the ventricle of rat. The tension development of the disrupted cardiac cells was measured with a mechanoelectric transducer (RCA 5734). The results were summarized as follows 1) 2 mM caffeine enhanced the regenerative $Ca^{++}$ release, whereas 2 mM Procaine inhibited the $Ca^{++}$ release as reported by other investigators. 2) Epinephrine at concentrations of $10^{-7},\;10^{-6}\;and\;10^{-5}M$ increased the regenerative $Ca^{++}$ release significantly but showed a poor dose response on the $Ca^{++}$ release. 3) Propranolol showed no effect on the regenerative $Ca^{++}$ release when studied alone. Furthermore, it showed no antagonistic effect on an increased regenerative $Ca^{++}$ release induced by epinephrine. 4) Other cardioactive agents such as acetylcholine, ouabain, isoproterenol and c-AMP at concentrations of $10^{-6}M$ showed no effect on the regenerative $Ca^{++}$ release. From the above results, it may be concluded that the cardioactive actions of these agents are not related directly to the process of regenerative $Ca^{++}$ release.

  • PDF

A Study on the Nylon Wire Holding and Release Mechanism for Cube Satellites by Applying Constant Holding

  • Koo, KeonWoo
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.4
    • /
    • pp.1-6
    • /
    • 2021
  • The non-explosive holding and release mechanism is used to prevent damage to the mission component caused by explosives when the deployment structure for Cube Satellites is separated. However, among the several types available, the non-explosive holding and release mechanism system using nylon wires depend on the nylon wire knot method and tightening power of the worker. Therefore, in this study, we conducted experiments with the operation of a new holding and release mechanism system by conceptualizing the Boa System Dial, which can provide a constant tightening force regardless of worker proficiency and deploying a imitational solar panel. In this study, the process of binding and unbinding with constant tension was recorded while applying the novel non-explosive holding and release mechanism using the Boa System Dial proposed. In addition, required advances are indicated for the application of the proposed system to actual Cube Satellites.

Dynamic Fracture Properties of Modified S-FPZ Model for Concrete

  • Yon, Jung-Heum;Seo, Min-Kuk
    • International Journal of Concrete Structures and Materials
    • /
    • v.19 no.1E
    • /
    • pp.25-32
    • /
    • 2007
  • The fracture energy evaluated from the previous experimental results can be simulated by using the modified singular fracture process zone (S-FPZ) model. The fracture model has two fracture properties of strain energy release rate for crack extension and crack close stress versus crack width relationship $f_{ccs}(w)$ for fracture process zone (FPZ) development. The $f_{ccs}(w)$ relationship is not sensitive to specimen geometry and crack velocity. The fracture energy rate in the FPZ increases linearly with crack extension until the FPZ is fully developed. The fracture criterion of the strain energy release rate depends on specimen geometry and crack velocity as a function of crack extension. The behaviors of micro-cracking, micro-crack localization and full development of the FPZ in concrete can be explained theoretically with the variation of strain energy release rate with crack extension.