• Title/Summary/Keyword: Release Guideline

Search Result 89, Processing Time 0.022 seconds

Derivation of preliminary derived concentration guideline level (DCGL) by reuse scenario for Kori Unit 1 using RESRAD-BUILD

  • Park, Sang June;Byon, Jihyang;Ban, Doo Hyun;Lee, Suhee;Sohn, Wook;Ahn, Seokyoung
    • Nuclear Engineering and Technology
    • /
    • v.52 no.6
    • /
    • pp.1231-1242
    • /
    • 2020
  • The Kori Unit 1 will be decommissioned after a permanent shutdown in June 2017. South Korea has a 0.1 mSv/yr exposure limit standard for limited or unlimited site release. This is South Korea's first commercial NPP; therefore, if the containment building is reused as a memorial hall, it will contribute to the improvement of public understanding and enhance the public's acceptance of NPPs. Also, existing Kori Unit 1 nuclear power plant manpower resources can be reused after decommissioning and resident staff and memorial hall visitors can activate nearby commercial areas. Therefore, such a reuse scenario may also prevent an economic recession. The exposure dose was calculated using the following scenarios: worker in the containment building, visitor in the containment building, and worker in buildings other than the containment building. The exposure dose in the buildings was calculated by the RESRAD-BUILD developed by the Argonne National Laboratory (ANL). The preliminary exposure dose and derived concentration guideline level (DCGL) were derived.

Energy Saving and Reduction of Atmospheric $CO_2$ Concentration by, and Planning Guideline for Urban Greenspace (도시녹지의 에너지절약 및 대기 $CO_2$ 농도저감과 계획지침)

  • 조현길;이기의
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.27 no.5
    • /
    • pp.38-47
    • /
    • 2000
  • Carbon dioxide is a major greenhouse gas causing climate change. This study quantified annual direct and indirect uptake of carbon by urban greenspace, and annual carbon release from vegetation maintenance and fossil fuel consumption. The study area was whole Chuncheon and Kangleung, and also two districts of Kangnam and Junglang in Seoul, cities located in middle Korea. Carbon uptake by urban greenspace played an important role through offsetting carbon release by 6-7% annually in Chuncheon and Kangleung. For Kangnam and Junglang, where the population density was relatively higher, urban greenspace annually offset carbon release by 1-2%. Future possible tree plantings could double annual carbon uptake by existing trees in urban lands (except natural and agricultural lands) of a study city. Based on study results, planning and management guidelines for urban greenspace were suggested to save energy and to reduce atmospheric $CO_2$ concentrations. They included selection of optimum tree species, proper planting location from buildings, design of multilayered planting, amendment of existing regulations for greenspace enlargement, avoidance f intensive vegetation maintenance, and conservation of natural vegetation.

  • PDF

Offsite Risk Assessment on Toxic Release (독성물질 저장설비의 사고시 사업장외에 미치는 영향평가)

  • Park, Kyoshik
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.3
    • /
    • pp.9-16
    • /
    • 2017
  • Toxic release is one of the most interested area in evaluating consequence to the vicinity of industry facilities handling hazardous materials. Chloric acid production facility is selected and toxic release is evaluated to assess the risk impacted to its off-site. Accident scenarios were listed using process safety information. The scenarios having effect to the off-site were selected and assessed further according to guideline provided by Korea government. Worst case and alternative scenarios including other interested scenarios were evaluated using ALOHA. Each evaluated scenario was assessed further considering countermeasures. The results showed that the facility handling chloric acid is safe enough and needed no further protections at the moment.

Offsite Risk Assessment on Chloric Acid Release (염산취급시설의 사고시 사업장외에 미치는 영향평가)

  • Park, Kyoshik
    • Korean Chemical Engineering Research
    • /
    • v.54 no.6
    • /
    • pp.781-785
    • /
    • 2016
  • Chloric acid is a toxic chemical and the risk of facility handling chloric acid was assessed from the list of accident scenario to provide countermeasure to keep the vicinity safe. Accident scenarios were listed by using MSDS and process safety information. The scenarios having effect to the off-site were selected and assessed further according to guideline provided by Korea government. Worst case and alternative scenarios including other interested scenarios were evaluated using ALOHA. Each evaluated scenario was assessed further considering countermeasures. The results showed that the facility handling chloric acid is safe enough and needed no further protections at the moment.

Adverse Effects on Crops and Soils Following an Accidental Release of Hydrogen Fluoride and Hydrofluoric Acid

  • Kang, Dae-Won;Kim, Hyuck-Soo;Kunhikrishnan, Anitha;Kim, Da-In;Lee, Seul;Park, Sang-Won;Yoo, Ji-Hyock;Kim, Won-Il
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.49 no.6
    • /
    • pp.651-654
    • /
    • 2016
  • A number of accidents relating to highly toxic hydrogen fluoride (HF) or hydrofluoric acid (HA) release have occurred over fast few decades in Korea. Thus, this study was conducted to investigate the fluoride (F) concentrations in paddy soil and brown rice from 2 different areas where the soils were exposed to HF and HA. In the first case, the HF leakage accident that occurred in 2012 affected the surrounding soils and crops and consequently, crops (rice) affected by HF were unavailable for forage even though F did not accumulate in the soil. For example, at the time of accident, F concentrations in brown rice samples were $33.0-1,395mg\;kg^{-1}$, while F concentrations in soil samples were $155-295mg\;kg^{-1}$ which were less than the Korean standard guideline values of $400mg\;kg^{-1}$. However, after a year, F concentrations in brown rice were observed below the detection limit ($1mg\;kg^{-1}$), although F concentrations in soils were similar with those in 2012. Also, large amounts of wastewater discharges containing HA occurred in 2013 and some agricultural soils exceeded the Korean standard guideline values for F ($400mg\;kg^{-1}$), but soil-plant F transfer was not observed. In conclusion, it was observed that soil to plant transfer of F is unlikely although HF and HA as gas or liquid form can cause direct damage to plants.

Consequence Modeling Methodology for Prediction of Hazard Distance for Two-phase Flow Release from the Pressurized Chlorine Saturated Liquid Storage Tank (가압 염소포화액체 저장탱크의 2상 흐름 누출에 대한 유해위험거리의 예측을 위한 결과영향 모델링 방법론)

  • Song D. M.;Park Y. S.;Park J. K.
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.4
    • /
    • pp.7-17
    • /
    • 1998
  • This study is to develop the consequence modeling methodology for quantitative prediction of the hazard distance(or toxic buffer distance) for two-phase flow continuous releases from the pressurized chlorine saturated liquid storage tank of the chemical plant facilities. The source term modeling was peformed by the refined analysis method based on USEPA's guideline and SuperChems model self-calculation, respectively. The hazard distance was predicted for STEL, IDLH and ERPGs(ERPG-2 and ERPG-3) concentrations being used as the toxic regultaion concentration in hazard estimation. To use as hazard estimation guideline for the establishment of the emergency response planning, the effects of source characteristics and meteorological vaiations on the hazard distance was especially considered for ERPG-2 concentration.

  • PDF

A Study on the Development of Installation and Management of Safety Shower (Safety shower 설치 및 관리기준 개선에 관한 연구)

  • Lee, Dong Hyeok;Yoo, Byung Tae
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.1-7
    • /
    • 2018
  • Currently chemical plant risk have been issued by occurring frequent accidents. Accidents can be generally composed of fire, explosion, release in chemical plant. In case of fire and explosion, accident victims are occurred immediately after accident but release accident, late emergency response cause damage to worker. Especially, there are many victims by late emergency response against chemical exposure to skin. In case of chemical exposure to skin, irreversible damage like death, blindness, burn can be prevented by washing immediately. Safety shower can provide the cleaning for chemical exposure to eye, skin. Most of chemical plants are built in 1980s so equipment become superannuated. In this reason, safety shower also cannot operate normally in emergency situation. Therefor safety shower should be managed by installation and management guideline. This study perform the establishment guideline for safety shower installation and inspection to increase the reliability.

Derivation of site-specific derived concentration guideline levels at Korea Research Reactor-1&2 sites

  • Kim, Geun-Ho;Do, Tae Gwan;Kwon, Jae;Ryu, Gangwoo;Kim, Kwang Pyo
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.493-500
    • /
    • 2022
  • The objective of this study was to derive derived concentration guideline levels (DCGLs) reflecting the site-specific characteristics of KRR-1&2. A total of 7 nuclides (H-3, C-14, Co-60, Sr-90, Cs-137, Eu-152, and Eu-154) were selected for DCGLs derivation. Radiation dose at the sites was evaluated with RESRAD-ONSITE program. The dose contribution due to direct external exposure was the highest during the entire evaluation period. Ingestion had the second effect. The DCGLs of Co-60 was derived to be 0.051 Bq/g, and DCGLs of Cs-137 was 0.193 Bq/g. The DCGLs of H-3 showed the highest value of 129 Bq/g. The ratio of DCGLs derived by applying site-specific values and default values ranged from 0.27 to 19.6. For six nuclides excluding H-3, KRR-1&2 sites and the overseas NPP sites showed similar DCGLs. H-3 showed large differences in DCGLs from this study and overseas NPPs. The large difference resulted from input parameter values applied to the sites. In conclusion, it is critical to apply site-specific parameter values reflecting the site characteristics to derive DCGLs for decommissioned site clearance. The result of this study can be used as a reference for nuclide selection and DCGLs derivation reflecting the site characteristics when decommissioning nuclear facilities, including nuclear power plants in Korea.

Comparing Customer Reactions Before and After of a Smart Watch Release through Opinion Mining (오피니언 마이닝을 통한 스마트 워치 출시 전후 소비자 반응 분석)

  • Lee, Jongho;Park, Heejun
    • The Journal of Bigdata
    • /
    • v.1 no.1
    • /
    • pp.1-7
    • /
    • 2016
  • Social media such as twitter has been popular by the diffusion of internet, and thanks to the radical improvement of computational ability of computers big data analysis became possible. This research is regarding about smart watch which is receiving attention as post-smartphone technology. Among various types of smart watch, this research focuses on the recently released Samsung Galaxy Gear S2. The main purpose of the research is to analyze customer's actual twitter data that was produced before and after the release of the smart watch to the market. Through the analysis, this research provides practical marketing strategy guideline, and also the analysis framework used in this research can be a research framework for other area and product researches.

  • PDF

The effect of sensitive and non-sensitive parameters on DCGL in probability analysis for decommissioning of nuclear facilities

  • Hyung-Woo Seo;Hyein Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3559-3570
    • /
    • 2023
  • In the decommissioning of nuclear facilities, Derived Concentration Guideline Level (DCGL) derivation is necessary for the release of the facility after the site remediation, which also needs to be implemented in the stage of establishing a decommissioning planning. In order to derive DCGL, the dose assessment for the receptors can be conducted from residual radioactivity by using RESRAD code. When performing sensitivity analysis on probabilistic parameters, secondary evaluation is performed by assigning a single value for parameters classified as sensitive. However, several options may arise in the handling of nonsensitive parameters. Therefore, we compared the results of the first execution of RESRAD applying probabilistic parameters for each scenario with the results of the second execution applying a single value to sensitive parameters among the probabilistic parameters. In addition, we analyzed the effect of setting options for non-sensitive parameters. As a result, the effect on DCGL were different depending on the application scenario, the target radionuclides, and the input parameter selections. In terms of the overall evaluation period, the DCGL graph of the default option was generally shown as the most conservative except for some radionuclides. However, it will not necessarily be given priority in the aspect of the need to reflect site characteristics. The reason for selecting a probabilistic parameter is the availability of the parameter and the uncertainty of applying a single value. Therefore, as an alternative, it can be consistently applied to distribution as an option for non-sensitive parameters after sensitivity analysis.