• Title/Summary/Keyword: Relays

Search Result 560, Processing Time 0.027 seconds

Development of a Temperature Controller for a Semiconductor Test Handler (반도체 테스트 핸들러를 위한 온도 제어기 개발)

  • Cho, Su-Young;Kim, Jae-Yong;Kang, Tae-Sam;Lee, Ho-Joon;Koh, Kwang-Ill
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.4
    • /
    • pp.395-401
    • /
    • 1999
  • In this paper, a temperature controller for a semiconductor test handler is proposed. First, a handware system for identification and control is established using RTD sensors, an A/D converter, solid state relays, a heater, and a computer system. Second, using ARMAX model and least square method, a chamber model for the design of a controller is identified through experiments. The identified model is verified to describe the real plant very well in the sense that it shows very similar input-output responses to those of the real system. With the identified model an LQG controller is designed. Frequency response of the designed controller shows that it has 15 dB of gainmargin and (-50˚, +50˚) of phase margin. Experiment with a real test handler demonstrates a good performance in the sense that its overshoot and steady state error are smaller and response time is faster, compared with those of a conventional PID controller.

  • PDF

A Study on Development of Interlocking Inspector for Electronic Interlocking System (전자연동장치 연동검사시스템 개발)

  • Lee, Jae-Ho;Cho, Bong-Kwan;Kim, Hyun-Min;Park, Gwi-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.271-274
    • /
    • 2001
  • The purpose of interlocking system was to prevent the route for a train being set up and its protecting signal cleared if there was already another, conflicting route set up and the protecting signal for that route cleared. Recently, the computer based control systems instead of conventional relays circuitry are widely used to industrial systems, therefore, interlocking system are rapidly changing from relay interlocking system to Electronic Interlocking System(EIS) that control requirements of interlocking at junctions using electronic circuits. In this paper, by examine checking technique of EIS, we will to acquire interlocking inspection algorithm and method for EIS and to develope inspection system for EIS. By using inspection system we obtain every advantage. It has the functions for test data generation and automatic test execution, and it can operate on personal computer. Time and cost for test work can be reduced to more of those now required by using this developed inspection system.

  • PDF

An Improved Analytic Model for Power System Fault Diagnosis and its Optimal Solution Calculation

  • Wang, Shoupeng;Zhao, Dongmei
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.89-96
    • /
    • 2018
  • When a fault occurs in a power system, the existing analytic models for the power system fault diagnosis could generate multiple solutions under the condition of one or more protective relays (PRs) and/or circuit breakers (CBs) malfunctioning, and/or an alarm or alarms of these PRs and/or CBs failing. Therefore, this paper presents an improved analytic model addressing the above problem. It takes into account the interaction between the uncertainty involved with PR operation and CB tripping and the uncertainty of the alarm reception, which makes the analytic model more reasonable. In addition, the existing analytic models apply the penalty function method to deal with constraints, which is influenced by the artificial setting of the penalty factor. In order to avoid the penalty factor's effects, this paper transforms constraints into an objective function, and then puts forward an improved immune clonal multi-objective optimization algorithm to solve the optimal solution. Finally, the cases of the power system fault diagnosis are served for demonstrating the feasibility and efficiency of the proposed model and method.

Spectral Efficient SF Block Coded Relay Transmission System without Cyclic Prefix for a Shadow Area (음영 지역을 위한 주기적 프리픽스 없는 주파수 효율적인 주파수 공간 블록 부호화 중계기 전송 시스템)

  • Won, Hui-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7456-7462
    • /
    • 2015
  • This paper proposes a spectral efficient space-frequency(SF) block coded single carrier-frequency division multiple access(SC-FDMA) transmission system in a relaying multi-path shadow area. The cyclic prefix(CP) is not used in the proposed system in order to prevent a loss of spectral efficiency due to the use of CP. The destruction of channel cyclicity due to the lack of CP is recovered at the receivers of relays and a destination station. Simulation results show that the performance of the proposed system without CP is almost same as that of the conventional system with full CP, thus increasing the spectral efficiency.

A Study on the Fault Detection and Discrimination of Transmission Line using Fault-generated High Frequency Signals (고주파를 이용한 송전선로의 사고 검출 및 판별에 관한 연구)

  • Lee, Dong-Jun;Kim, Chul-Hwan;Kim, Il-Dong
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.8
    • /
    • pp.924-931
    • /
    • 1999
  • Most conventional protection relays are based on processing information in the spectrum that is close to or at power frequency. It is, however, widely known that faults on transmission lines produce frequency components of a wide range. High frequency signals caused by sudden changes in system voltage that occurs in the immediate post-fault period are generally outside the bandwidth of receptibility of most protection scheme. In this respect, a specially designed stack tuner is connected to the coupling capacitor of CVT, in order to capture the high frequency signals. Digital signal processing is then applied to the captured information to determine whether the fault is inside or outside the protected zone, and to discriminate the fault type. In this paper, modal transform is not applied to fault generated signals, because signals which are converted by modal transform are not have an information of each phase any longer. Instead, using peak voltage value of data windows is able to discriminate fault type. The paper concludes by presenting fault detection and discrimination of various faults on transmission line which are based on extensive simulation studies carried out on a typical 154kV Korean transmission line, using the EMTP software.

  • PDF

Development of Interlocking Inspection Simulator for Electronic Interlocking System (전자연동장치를 위한 연동검사시스템의 개발)

  • Lee, Jae-Ho;Hwang, Jong-Gyu;Park, Young-Soo;Park, Gui-Tae
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.2
    • /
    • pp.70-76
    • /
    • 2004
  • The purpose of interlocking system in railway is to prevent the route for a train being set up and its protecting signal cleared if there were already another, conflicting route set up and the protecting signal for that route cleared. Recently, conventional relays circuitry in industrial field is replaced to computer-based control systems according to the advance of computer and communication technology. Therefore, interlocking systems in railway field are rapidly changing from existing relay-based interlocking system to computer-based electronic ones that executes the vital interlocking logic to assure the safety train routes at trackside signaling equipment room using electronic circuits. So it is very important to verify the performance of developed electronic interlocking system by plentiful laboratory testing before actually application in the railway system. However the laboratory testing in the present state of railway signaling is preformed individually by manual, so very much test time and cost are required. To solve these problems, we are developed the simulator for automatic interlocking inspection in this research. This simulator is able to operate on general personal computer and has following beneficial functions : automatic test sheet generation for inspection, automatic inspection execution and et al. The experiments are executed to test the feasibility of the developed simulator the experimental results have good agreements with the anticipated ones.

High Precision Control of Servo Control System Using The Adaptive Fuzzy Controller (적응 퍼지제어기를 이용한 서보 제어 시스템의 정밀제어)

  • 조정환
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.3
    • /
    • pp.110-115
    • /
    • 2002
  • This paper proposes the adaptive fuzzy control system using the microprocessesor for high precision control of automation systems which exist non-linearities such as saturation, relays, hysteresis, and dead zones. The proposed system which provides the improvement in terms of the control region in transient and adaptive control, first used the frequence-locked mothed driving a system to generate a output voltage proportional to the frequency diffierence of relnence input signal and feedback signal for fast transient response,, and when the error reaches the preset value, used the adaptive fuzzy logic for precision control. The theoretical and experimental studies have been carried out. The presented results from the above investigation show considerable improved performance in the precision control of servo control systems.

Analysis and Modeling of Wireless Power Transfer Systems using Magnetically Coupled Resonator Scheme with Relay Coils (릴레이 코일을 포함한 자기 공명 방식 무선 전력 전송 시스템의 분석 및 모델링)

  • Park, Hee-Su;Kwon, Min-Sung;Kim, Min-Ji;Park, Hyeon-Min;Ku, Hyun-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.1
    • /
    • pp.69-78
    • /
    • 2014
  • In this paper, characteristics of wireless power transfer (WPT) systems using magnetically coupled resonance scheme with relay coils are investigated and modeled. Especially, asymmetric frequency splitting characteristics in over-coupled region of WPT with relays are measured and accurately modeled. Transmitter, receiver, and relay coils are modeled with R, L, C equivalent circuits. Using these circuit models and mutual inductances between coils, a WPT system is described with a linear matrix equation. For under-coupled region, a matrix is simplified considering only mutual inductances between adjacent coils. An analytical transfer characteristic of WPT system vs. distance is extracted using an inverse matrix that is acquired by Gauss elimination method for the simplified matrix. For over-coupled region, a matrix considering mutual inductances between non-adjacent coils is used to predict a frequency splitting characteristics accurately. A 6.3MHz WPT system with relay coils is implemented and measured. An accuracy of the model is investigated by comparing the output of the model with the measured results.

Development of the Power System Fault Diagnostic Algorithm for the Proton Accelerator Research Center of PEFP (양성자가속기 연구센터 전력계통 고장진단 알고리즘 개발)

  • Mun, Kyeong-Jun;Jeon, Gye-Po;Lee, Seok-Ki;Kim, Jun-Yeon;Jung, W.;Yoo, Suk-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.685-686
    • /
    • 2007
  • This paper presents an application of power system fault diagnostic algorithm for the PEFP Proton Accelerator Research Center using neural network. Proposed fault diagnostic system is constructed by the radial basis function (RBF) neural network because it has the capabilities of the pattern classification and function approximation of any nonlinear function. Proposed system identifies faulted section in the power system based on information about the operation of protection devices such as relays and circuit breakers. In this paper, parameters of the RBF neural networks are tuned by the GA-TS algorithm, which has the global optimal solution searching capabilities. To show the validity of the proposed method, proposed algorithm has been tested with a practical power system in Proton Accelerator Research Center of PEFP.

  • PDF

Performance Analysis And Optimization For AF Two-Way Relaying With Relay Selection Over Mixed Rician And Rayleigh Fading

  • Fan, Zhangjun;Guo, Daoxing;Zhang, Bangning;Zeng, Li
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.6 no.12
    • /
    • pp.3275-3295
    • /
    • 2012
  • In this paper, we analyze the performance of an amplify-and-forward (AF) two-way relaying system, where two sources exchange information via the aid of an intermediate relay that is selected among multiple relays according to max-min criterion. We consider a practical scenario, where one source-relay link undergoes Rician fading, and the other source-relay link is subject to Rayleigh fading. To be specific, we derive a tight lower bound for the outage probability. From this lower bound, the asymptotic outage probability and average symbol error rate (SER) expressions are derived to gain insight into the system performance at high signal-to-noise ratio (SNR) region. Furthermore, we investigate the optimal power allocation (PA) with fixed relay location (RL), optimal RL with fixed PA and joint optimization of PA and RL to minimize the outage probability and average SER. The analytical expressions are verified through Monte Carlo simulations, where the positive impact of Rician factor on the system performance is also illustrated. Simulation results also validate the effectiveness of the proposed PA and relay positioning schemes.