• 제목/요약/키워드: Relay Zone

검색결과 56건 처리시간 0.036초

2회선 송전선로에서 상호임피던스와 고장저항을 고려한 거리계전기의 동작 특성 연구 (A Study on Adaptive Distance Protection of Double-circuit Line with Mutual Impedance and Fault Resistance)

  • 이원석;정창호;김진오
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권4호
    • /
    • pp.221-221
    • /
    • 2004
  • Power system has recently used Double-circuit Line and Multi-circuit Line in the industrial development. This has an advantage of system stability and reliability, but the complexity of the system has a disadvantage that makes it difficult to protect the power line. Double-circuit Line has two operation conditions in the Single-circuit operation and Double-circuit operation, so it has mutual impedance. To make it possible for the remaining single-line to operate independently while there is a fault with first line or when maintenance is needed, a trip region for the single-circuit operation should be set in order to set the relay trip region. An optimal trip region for each operation, a different operational conditions for the relay setting should be calculated. In this paper, trip regions of each operation condition have been compared by considering mutual impedance and fault resistance that led to the calculation of fault impedance. Also, as we know that one of the advantages in the distance relay is the back-up protection, we calculated the trip region(Zone-2) in consideration of the mutual impedance.

센서 네트워크 기반 효율적인 멀티 홉 릴레이 전송 (Efficient multi-hop relay transmission on sensor network)

  • 권대길;김도훈;원희철;황규성
    • 한국산업정보학회논문지
    • /
    • 제17권7호
    • /
    • pp.1-8
    • /
    • 2012
  • 본 논문에서는 유비쿼터스 환경 구축을 위한 센서 네트워크에서 효율적으로 데이터를 전송할 수 있는 멀티홉(multi-hop) 릴레이 (Relay) 전송 시스템을 고려한다. ISM 주파수 대역을 사용하는 DBO-CSS (Differentially Bi-Orthogonal Chirp Spread Spectrum) 방식의 확산대역 신호 중 하나인 첩 (Chirp) 신호를 이용하여 구축된 센서 네트워크를 기반으로 센서 거리 및 사물 위치인식을 위한 효율적인 릴레이 프로토콜을 제안한다. 효율적인 네트워킹 접속을 위하여 Zone information packet, Hop information packet, Tag information packet 및 Application serial packet 의 4종류의 패킷구조를 설계하여 구현하였으며, 구축된 센서 네트워크를 기반으로 사물의 위치인식의 효율성을 높이기 위한 구현 알고리즘을 제안하였다. 최종적으로 $15m{\times}15m$ 멀티셀 및 10 홉으로 구성된 테스트베드 시스템에서 제안한 프로토콜의 성능의 우수성을 검증한다.

임피던스 계전기를 이용한 발전기 비동기 투입 보호 연구 (A Study on Protection of Generator Asynchronization by Impedance Relaying)

  • 이종훤
    • 전기학회논문지
    • /
    • 제60권11호
    • /
    • pp.2000-2006
    • /
    • 2011
  • Asynchronous phenomenon occurs on the synchronous generators under power system when a generator's amplitude of electromagnetic force, phase angle, frequency and waveform etc become different from those of other synchronous generators which can follow instantly varying speed of turbine. Because the amplitude of electromagnetic force, phase frequency and waveform differ from those of other generators with which are to be put into parallel operation due to the change of excitation condition for load sharing and the sharing load change, if reactive current in the internal circuit circulates among generators, the efficiency varies and the stator winding of generators are overheated by resistance loss. Where calculation method of protection settings and Logic for Protection of Generator Asynchronization will be recommended, A distance relay scheme is commonly used for backup protection. This scheme, called a step distance protection, is comprised of 3 steps for graded zones having different operating time. As for the conventional step distance protection scheme, Zone 2 can exceed the ordinary coverage excessively in case of a transformer protection relay especially. In this case, there can be overlapped protection area from a backup protection relay and, therefore, malfunctions can occur when any fault occurs in the overlapped protection area. Distance relays and overcurrent relays are used for backup protection generally, and both relays have normally this problem, the maloperation, caused by a fault in the overlapped protection area. Corresponding to an IEEE standard, this problem can be solved with the modification of the operating time. On the other hand, in Korea, zones are modified to cope with this problem in some specific conditions. These two methods may not be obvious to handle this problem correctly because these methods, modifying the common rules, can cause another coordination problem. To overcome asynchronizing protection this paper describes an improved backup protection coordination scheme using a new Logic that will be suggested.

A Special Protection Scheme Against a Local Low-Voltage Problem and Zone 3 Protection in the KEPCO System

  • Yun, Ki-Seob;Lee, Byong-Jun;Song, Hwa-Chang
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권3호
    • /
    • pp.294-299
    • /
    • 2007
  • This paper presents a special protection scheme, which was established in the KEPCO (Korea Electric Power Corporation) system, against a critically low voltage profile in a part of the system after a double-circuit tower outage. Without establishing the scheme, the outage triggers the operation of a zone 3 relay and trips the component. This sequence of events possibly leads to a blackout of the local system. The scheme consists of an inter-substation communication network using PITR (Protective Integrated Transmitter and Receiver) for acquisition of the substations' data, and under-voltage load shedding devices. This paper describes the procedure for determining the load shedding in the scheme and the experiences of the implementation.

변압기의 선간 단락사고 보호를 위한 지락비율차동 계전 알고리즘의 성능향상 방법 (Improved Ground differential relaying algorithm for the protection of a line-to-line fault of transformer)

  • 강해권;김진호;김세창;박종수;박종은
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.760-761
    • /
    • 2011
  • Ground differential relay is used to provide fast, sensitive, and selective protection for the wye connected and grounded electrical power equipment such as generators, power transformers, and grounding transformers. The ground differential protection only protects the ground faults within the protection zone, so that it can't protect the line-to-line fault. This paper proposes the algorithm to provide the protection for the line-to-line fault through the ground differential protection. The proposed algorithm detects the line-to-line fault of transformer using the comparison between the positive and the negative current, when the ground differential relay dose not operate. The performance of the algorithm is verified using a PSCAD/EMTDC simulator under various case studies.

  • PDF

오차확률 기반 송전계통 보호계전기 보호도 평가방법 연구 (Protectability Evaluation of Distance Relay based on a Probabilistic Method for Transmission Network)

  • 짱원하오;최면승;이승재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.286_287
    • /
    • 2009
  • In this paper, the protectability of distance relay is furtherly researched. Based on the probabilistic modeling of the measurement errors, the protectability of three zones is presented in detail by considering their different protection aims denoted by sensitivity and selectivity. The optimal setting for the each zone can be obtained to provide a reference for the practical application.

  • PDF

풍력단지의 Fault Ride-Through 기능을 위한 연계선 보호용 거리계전기의 성능향상 기법 (Improved distance relay suitable for intertie protection of a wind farm considering Fault Ride-Through requirement)

  • 강용철;강해권;정태영;이병은;장성일;김용균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.442_443
    • /
    • 2009
  • A large wind farm should satisfy the requirements for a grid and accomplish the optimization of the wind farm system. In that point of view, the wind farm intertie protection system, which must consider the Fault Ride-Through (FRT) requirement for more reliable protection, should be improved. This paper proposes a modified distance relay suitable for protection of a wind farm intertie considering a FRT requirement. The frequency change is used to discriminate the intertie fault from a outside zone fault. The performance of the proposed algorithm is verified using a PSCAD/EMTDC simulator.

  • PDF

증조류 선로 고장시 인접선로 과부하에 의한 거리계전기 동작 및 전압불안정 현상 연구 (A study of impedance relay operation and voltage instability caused by over load of neighborhood line at contingency of heavy load line)

  • 윤기섭;이형한;김창곤;안보순
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.359-361
    • /
    • 2005
  • This paper presents the method of countermeasures before voltage collapse by load encroachment(impedance of load ability on R-X locus decrease toward zero point) and describes a study of impedance relay(zone-3) operation and voltage instability caused by over load of neighborhood line at contingency of heavy load line.

  • PDF

신경회로망을 이용한 거리 계전기의 속도 개선 방법 (A Method to Improve the Speed of a Distance Relay Using Artificial Neural Networks)

  • 조경래;강용철;깅성수;남순열;박종근;강상희;김광호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.677-679
    • /
    • 1996
  • This paper describes a method to improve the speed of a distance relay based on a differential equation of transmission lines using feedforward artificial neural networks (ANN) on an EHV system. For the impedance calculation an integration approximation to the differential equation is used and then an ANN is trained with the impedance convergence characteristic. The ANN predicts the fault distance with some calculated resistances and reactances before they reach trip zone. Thus, the proposed method can improve the speed of distance relays, significantly if a high sampling rate such as 48 samples per cycle is employed.

  • PDF

임의의 토폴로지를 갖는 OFDMA 다중홉 셀룰러 네트워크의 하향링크 간섭 완화를 위한 채널 할당 방법 (Interference Aware Downlink Channel Allocation Algorithm to Improve Throughput on OFDMA Cellular Multihop Networks with Random Topology)

  • 임성국;이재용
    • 한국통신학회논문지
    • /
    • 제40권1호
    • /
    • pp.43-51
    • /
    • 2015
  • LTE-advanced와 IEEE 802.16m과 같은 차세대 셀룰러 네트워크는 중계기를 이용하여 적은 비용으로 높은 전송률을 제공하며 음영지역을 해소한다. 하지만 중계기에 의해 좁아진 셀 간격 때문에 셀 간 간섭은 심화되며, 특히 OFDMA를 사용하는 셀룰러 네트워크의 하향 액세스 링크(access link)는 많은 양의 데이터를 기지국이나 중계기가 동시에 사용자 단말에게 전송하기 때문에 간섭에 의한 성능저하가 심각하다. 이를 해결하기 위한 기존의 연구는 중계기의 분포를 대칭적으로 가정하였기에 실제 네트워크에 적용하는 것은 불가능하였다. 본 논문에서는 임의의 위치에 설치된 다수의 중계기를 이용하는 다중홉 셀룰러 네트워크에서 셀 간의 간섭을 완화하기 위한 채널할당방안을 제안하여 신호대간섭잡음비(Signal to Interference plus Noise Ratio)를 높이고, 전력 제어에 필요한 제어 메시지의 수를 감소시켜 네트워크의 데이터 전송률을 높이고자 한다.