• Title/Summary/Keyword: Relay Model

Search Result 233, Processing Time 0.026 seconds

Optimal Placement of CRNs in Manned/Unmanned Aerial Vehicle Cooperative Engagement System

  • Zhong, Yun;Yao, Peiyang;Wan, Lujun;Xiong, Yeming
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.1
    • /
    • pp.52-68
    • /
    • 2019
  • Aiming at the optimal placement of communication relay nodes (OPCRN) problem in manned/unmanned aerial vehicle cooperative engagement system, this paper designed a kind of fully connected broadband backbone communication topology. Firstly, problem description of OPCRN was given. Secondly, based on problem analysis, the element attributes and decision variables were defined, and a bi-level programming model including physical layer and logical layer was established. Thirdly, a hierarchical artificial bee colony (HABC) algorithm was adopted to solve the model. Finally, multiple sets of simulation experiments were carried out to prove the effectiveness and superiority of the algorithm.

Development of SFCL Model using RTDS (RTDS 초전도한류기 해석모델 개발)

  • Lee, Seung-Ryul;Kwon, Jung-Ji;Yoon, Jae-Young;Lee, Byong-Jun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.10 no.3
    • /
    • pp.9-13
    • /
    • 2008
  • It is very important to study the protective relaying system from the viewpoint of technical analysis to apply superconducting power devices to real power systems. In this paper, we developed Superconducting Fault Current Limiter (SFCL) analysis model using Real Time Digital Simulator(RTDS) for protective relay tests in power system with SFCLs. The RTDS model has the operation mechanism of a real SFCL system.

A protective coordination of HTS cable power system using EMTP-RV (초전도케이블 계통의 상정사고에 대한 보호협조 연구)

  • Lee, Hyun-Chul;Lee, Geun-Joon;Baek, Young-Sik;Yang, Beoung-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.209-210
    • /
    • 2011
  • This paper proposed protective coordination on HTS(High Temperature Superconducting) cable on 22.9kV distributed system. HTS cable transient model is developed and tested using EMTP-RV, system protective coordination is studied with ETAP. Possible contingency and protective scheme are considered real distribution system in Icheon substation. The simulation results was showed, in protective case to apply conventional relay, that appeared problem on HTS cable inner part. The HTS cable couldn't protection on contingency state of power system. It was using high-speed relay system instead of conventional relay system. Then, the HTS cable was protected contingency by circuit breaker.

  • PDF

Development of Impedance Locus Model for Protective Relay Dynamic Test (보호 계전기 동특성 테스트를 위한 임피던스 궤적 모델 개발)

  • Kim, Su-Nam;Lee, Jae-Gyu;Lee, Myeong-Su;Yu, Seok-Gu
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.9
    • /
    • pp.451-459
    • /
    • 2002
  • This paper presents a method for modelling of the impedance locus in order to test the protective relay with dynamic. This paper has the two parts, the first part is the configuration of impedance locus with voltage magnitude, total impedance magnitude and angle. And the second part is the control of the locus speed with deviation of two frequencies. The proposed method is applied to two machine equivalent system with PSCAD/EMTDC to show its effectiveness.

Development of automation system for relay assembly and test (릴레이 결합 및 검사 자동화 시스템 개발)

  • 국금환;최동엽
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.606-610
    • /
    • 1991
  • A relay is the one of small electrical components for automobiles and used for industry widely. We have developed the automation system for relay assembly and test to make it improve the productivity and decrease the man power. In order to determine the objective process of automation, we investigated 6 small and medium sized-enterprises and 1 greate sized-enterprise producing relays. And, we selected 2 model enterprises of them. One of the two is the system to develop. The scope of our study is the analyse of the conventional workcell, the determination of the system specification, the design of the system layout, the determination of the system cycle time, the design of the system mechanism, and the development of the controller for the system. We think that the developed system may be solve the technical and the economical problems interrupted efficiential automation of domastic small and medium sized-enterprises, and improve the international competitive power.

  • PDF

A Study on the Transmission Constraints Modeling of Carrier Relay Signal over ATM network (전력용 보호제어정보의 ATM전송조건 모델링에 관한 연구)

  • Lee, Jae-Jo;Yoon, Il-Hwan;Yoo, Jae-Tack;Lee, Won-Tae;Huh, Young;Kim, Kwan-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.584-587
    • /
    • 1997
  • In this paper, we present a transmission constraints modeling of carrier relay signal over ATM network. Since teleprotection system, which is used for protecting power transmission lines using telecommunications, has strict transmission delay constraints, it is a important problem to transmit teleprotection signals in future utilities' ATM networks when utilites' communications are integrated. Therefore, we considered the transmission constraints of carrier relay signal over ATM network and the transmission model system.

  • PDF

Joint Radio Selection and Relay Scheme through Optimization Model in Multi-Radio Sensor Networks

  • Lee, HyungJune
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.12
    • /
    • pp.4451-4466
    • /
    • 2014
  • We present joint radio selection and relay scheme that delivers data from a source to a sink in heterogeneous stationary sensor networks consisting of various radio interfaces. The proposed scheme finds the optimal relay nodes and their corresponding radio interfaces that minimize energy consumption throughout the network while satisfying the end-to-end packet deadline requirement. We formulate the problem of routing through radio interface selection into binary integer programs, and obtain the optimal solution by solving with an optimization solver. We examine a trade-off relationship between energy consumption and packet delay based on network level simulations. We show that given the end-to-end deadline requirement, our routing algorithm finds the most energy-efficient routing path and radio interface across mesh hops. We demonstrate that the proposed routing scheme exploits the given packet delivery time to turn into network benefit of reducing energy consumption compared to routing based on single radio interface.

Outage Analysis of a Cooperative Multi-hop Wireless Network for Rayleigh Fading Environment

  • Asaduzzaman, Asaduzzaman;Kong, Hyung-Yun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.2A
    • /
    • pp.133-138
    • /
    • 2011
  • This paper presents an information theoretic outage analysis for physical layer of a cooperative multihop wireless network. Our analysis shows that cooperation by selecting a proper relay at each hop increases the coverage or data rate of the network. In our analysis we consider both symmetric and asymmetric network model. We also investigate the availability of cooperative relay at each hop and show that end-to-end performance of the network depends on the relay selection procedure at each hop. We also verify our analytical results with simulations.

Secure Connectivity Probability of Multi-hop Clustered Randomize-and-Forward Networks

  • Wang, Xiaowei;Su, Zhou;Wang, Guangyi
    • ETRI Journal
    • /
    • v.39 no.5
    • /
    • pp.729-736
    • /
    • 2017
  • This work investigates secure cluster-aided multi-hop randomize-and-forward networks. We present a hop-by-hop multi-hop transmission scheme with relay selection, which evaluates for each cluster the relays that can securely receive the message. We propose an analytical model to derive the secure connectivity probability (SCP) of the hop-by-hop transmission scheme. For comparison, we also analyze SCPs of traditional end-to-end transmission schemes with two relay-selection policies. We perform simulations, and our analytical results verify that the proposed hop-by-hop scheme is superior to end-to-end schemes, especially with a large number of hops or high eavesdropper channel quality. Numerical results also show that the proposed hop-by-hop scheme achieves near-optimal performance in terms of the SCP.

A New Protective Relaying Algorithm for Power Transformer Based on Three Phase Voltage and Current (전압, 전류 변화 추이를 이용한 전력용 변압기 보호계전 알고리즘)

  • Kim, Sang-Tae;Lee, Seung-Jae;Kang, Sang-Hee;Jin, Bo-Gun;Yoon, Sang-Hyun;Lee, Tae-Sung
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.4
    • /
    • pp.157-165
    • /
    • 2001
  • The two criteria to identify the disturbances of the power transformer has been reported in this paper. They have been derived through EMTP simulations of internal faults, inrush and overexcitation for the model of 154/22.9[kV], 40[MVA], Y-Y three-phase power transformer. We propose the crisp algorithm which uses two criteria. A series of test results clearly indicate that the method can identify not only an internal fault but also the other transients. The average of relay operation times is about 7.2[ms]. The proposed algorithm immunes to the transient state.

  • PDF