A development of digital motor protection relay for power supervisory control system (전력감시 제어시스템을 위한 모터보호용 디지탈 보호계전기 개발)

  • 이성환;우천희;정현호;김정한;김상철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1496-1499
    • /
    • 1997
  • Recently the major requirements have emerged in industrial substation system field. One is the simple arrangement of main power supply equipment and the other is the introduction of highly computer-controlled system for operation, maintenance and protection. This paper deals with the systems including motor-type relay systems, supervisory and control systems, digital type relay protectiion systems.

  • PDF

Performance Analysis of Incremental Cooperative Communication with Relay Selection Based on The Relays Arrangement (중계기 선택 기법이 적용된 증분 협력 통신의 중계기 배치에 따른 성능 분석)

  • Kim, Lyum;Kong, Hyung-Yun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.10
    • /
    • pp.941-950
    • /
    • 2011
  • In this paper, we analysis the end-to-end performance of the incremental cooperative communication with relay selection. In the conventional cooperative scheme, the source(S) broadcasts the signal to the relay(R) and the destination(D) at 1st phase, and the R forwards the signal to the D at 2nd phase. Although this scheme can improve performance and provide diversity gain, it suffers from decreasing spectrum efficiency. In order to overcome this problem, the incremental cooperative model can be used. In this paper, we study two incremental cooperative method : the first uses ARQ with threshold SNR and the second uses HARQ with channel coding. we also evaluated performance of the incremental cooperative communication based on the R arrangement by using both methods.

Implementation of Co-Channel Radio Relay System and Its Performance Evaluation with Synchronous Digital Hierarchy (동기식 디지틀 계위의 동일채널 무선 전송장치구현 및 성능분석)

  • 서경환
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.11
    • /
    • pp.10-22
    • /
    • 1998
  • In this paper, as a way of improving the availability and spectral efficiency of radio relay system, a co-channel radio relay system based upon the synchronous digital hierarchy is developed and its performance measured by 64-QAM with a never-seen multi-purpose ASIC chip is illustrated. This system provides a couple of transmission capacity compared with alternative channel arrangement. By adopting a powerful complex 13-tap adaptive time domain equalizer and cross-pol interference canceller, improvement of more than 1.5 ~ 2.0 dB in signature is obtained in comparison to 9 or 11-tap adaptive time domain equalizer, and about 22.5 dB in improvement factor of cross-pol interference canceller is achieved at C/N of 24.5 dB. In addition, digital filter makes it possible to optimize the occupied bandwidth by selecting an appropriate roll-off factor externally. It is expected that co-channel radio relay system with the powerful multi-purpose ASIC chip plays a key role in creating a value-added product, reliability, and reducing the outage time.

  • PDF

Simulation of Fault-Arc using EMTP (EMTP를 이용한 아크 사고의 모의)

  • Byun, S.H.;Choi, H.S.;Chae, J.B.;Kim, C.H.;Han, K.N.;Kim, I.D.;Kim, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.850-852
    • /
    • 1996
  • High impedance fault (HIF) is defined as fault that general overcurrent relay can't detect or interrupt, Especially when HIF occur under 15 kV, energized high voltage conductor results in fire hazard, equipment damage or personal threat. Because most HIF occur arc, HIF detection using arc is to increase. Numerical arc model can be applied in an electromagnetic transients program (EMTP) to reproduce the dynamic and random characteristic of arcs for any insulator arrangement, current and system voltage. It allows the representation of any network configuration to be investigated, so the digital simulation of arc faults through air can be substitute for demanding power arc test.

  • PDF