• Title/Summary/Keyword: Relaxation load of ground

Search Result 16, Processing Time 0.02 seconds

Pullout Capacity of Ground Anchors in Weathered Soil (풍화토 지반에 설치된 앵커의 인발 특성)

  • 김낙경
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.4
    • /
    • pp.231-239
    • /
    • 2001
  • 건설 현장에서 널리 사용되고 있는 그라운드 앵커의 거동 특성을 연구하기 위하여 계측기를 부착한 일곱 개의 그라운드 앵커를 국내에 널리 분포되어 있는 화강 풍화토 지반인 $\bigcirc$$\bigcirc$$\bigcirc$대학교 지반 시험장에 설치하여 인발 시험을 수행하였다. 저압 그라우트 인장형 앵커 3개와 압축형 앵커 4개를 시험하였고, 시험은 AASHTO 규정에 의거한 인발시험, 크리프시험, 장기거동시험을 수행하였다. 시험 결과로부터 화강 풍화토 지반에 설치된 저압그라우트 직선형 앵커의 지반과의 마찰계수, 크리프 변형율, 하중감소 특성을 평가하였다.

  • PDF

Load transfer mechanism due to tunnel excavation in the jointed sandy ground (불연속면을 포함한 사질토 지반에서 터널 굴착에 따른 하중전이)

  • Lee, Sang-Duk;Kim, Yang-Woon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.5 no.3
    • /
    • pp.217-226
    • /
    • 2003
  • This study is focused on the finding out load transfer mechanism in the ground near the tunnel during tunnel excavation in the jointed sandy ground. Laboratory model tests were performed on various cases of the overburden heights above tunnel crown, location, and degree of discontinuity planes. For model tests, a movable plate was installed in the midst of the bottom of sandy ground. This plate, moving downwards, was intended to model the stress relaxation during tunnel excavation. The load transfer was measured at the fixed separated bottom plates adjacent to the movable plate. As the result, the loosening zone and the load-transfer form around the tunnelling site were affected by the overburden height and the characteristics of discontinuous planes. And large loosening zone was developed along the discontinuous planes which were close to the tunnel.

  • PDF

Improvement of Lift-off Tests via Field Evaluation of Residual Load in Ground Anchor (현장 잔존긴장력 평가를 통한 리프트오프 시험 방법 개선)

  • Song, minkwon;Park, Seong-yeol;Lee, Sangrae;Cho, Wanjei
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.5
    • /
    • pp.43-51
    • /
    • 2019
  • At present, the ground anchor method is commonly applied to securing the slope stability in Korea. The ground anchor is reported to decrease in tensile load due to aging and environmental influences with time such as corrosion, relaxation, creep and so on. In Korea, the lift-off test is performed for the periodic inspection or cases when the symptoms of deterioration on anchors and the residual tensile load of the anchors is checked. However, the current lift-off test standard (MOLIT, 2010) is not fully specified in details. In this study, the factors affecting the lift-off test were investigated based on the previous research and foreign standards and lift-off tests were performed with consideration for the loading and unloading cycle, load increment method, and tensioning tendon method. Based on the results, this paper proposes improved testing and evaluation procedures of the lift-off test considering the workability and time limits in the field.

Reinforcement Bulb Body Pull-out Resistance Force Behavior Characteristics according to Ground Conditions (지반조건에 따른 보강구근체 인발저항력 거동 특성)

  • An, JunYoung;Shim, JeongHoon;Jeong, JiSu;Lee, SeungHo
    • The Journal of Engineering Geology
    • /
    • v.27 no.1
    • /
    • pp.41-49
    • /
    • 2017
  • In this study, we tried to confirm the influence range in the ground due to Bulbed, Reinforcement change and ground conditions change through numerical analysis. By checking the increase width of the reinforcement effect accompanying the increase of Bulbed, grasping the trend accompanying the change of the ground conditions and deciding soil nail Reinforcement and Bulbed, so that economical construction will be carried out It can be judged that it can be utilized as basic material. In this paper, we analyzed the Displacement due to positional load of reinforcement by utilizing MIDAS GTS NX which is a universal numerical analysis program. In addition, it is necessary to ensure the diameter star economy of Bulbed size and Reinforcement by comparing / analyzing whether the Bulbed relaxation region of Reinforcement represents arbitrary characteristics in the ground in Sandy soil, Weathered granite soil ground due to soil nail pullout load Numerical analysis was conducted to select criteria that can be done.

Model Testing on the Behavior of Laterally Loaded Pile in NC Clay Soils (정규압밀 점토 지반에서 매입말뚝의 수평거동에 관한 모형 실험 연구)

  • Kim, Byeong-Tak;Lee, Sang-Ung;Kim, Yeong-Su
    • Geotechnical Engineering
    • /
    • v.14 no.5
    • /
    • pp.39-52
    • /
    • 1998
  • The pupose of the present paper is to estimate the effects of constraint condition of pile head, ground condition(dry unit weight. $\gamma_4$) and embedded pile lengths on the behavior of single pile which is embedded in normally consolidated clay. BBperiment functions can be quantified to these effects obtained from the results of model teats. The ground of model tests is normally consolidated( NC ) clay under three kinds of effective vertical stress. The results of the model tests using the steel pile of two different embedded pile length and of free-head and fired-head show that the lateral load-deflection relationship is to be elasto plastic behavior below $\gamma_d/\gamma_{dmax}$: 0.84 and that the reduction of lateral load of beyond maximum lateral load($Q_{max}$) at each model test is significantly time-dependent. In this study, it is shown that the displacement relationship can be fitted to exponential function of time by model best results. The effect of ground conditions on the ultimate and yield lateral load is fitted to exponential function including the ratio of dry unit weight to maximum dry unit weight. When tests by results are compared with those from Broms and Budhu et at., the predicted results are over-estimated about 27-87 ayo. In effectivity of constraint condition of pile head on the lateral load-deflection response, the $Q_{fixed}/Q_{gree}-y/D$ relationship is highly non-linear and fitted to parabolic function.

  • PDF

Development of Removable-Strand Compression Anchor (압축형 제거 앵커의 개발 및 성능 평가)

  • 김낙경;김성규
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.339-346
    • /
    • 2001
  • For temporary excavation support in private land area, the strand of ground anchor should be removed In order to get permission to install anchors. The extractable or removable-strand compression anchor system was developed and evaluated by a series of pull-out load tests. Anchor pull-out tests were performed on seven instrumented full-scale low-pressure grouted anchors installed in weathered soil at the Geotechnical Experimentation Site at Sungkyunkwan University, Four anchors are the compression type anchors and three are the tension anchors. Performance test, creep test, and long term relaxation test were performed and presented. Load distributor was developed in order to distribute large compressive stresses in grout.

  • PDF

Surrounding rock pressure of shallow-buried bilateral bias tunnels under earthquake

  • Liu, Xin-Rong;Li, Dong-Liang;Wang, Jun-Bao;Wang, Zhen
    • Geomechanics and Engineering
    • /
    • v.9 no.4
    • /
    • pp.427-445
    • /
    • 2015
  • By means of finite element numerical simulation and pseudo-static method, the shallow-buried bilateral bias twin-tube tunnel subject to horizontal and vertical seismic forces are researched. The research includes rupture angles, the failure mode of the tunnel and the distribution of surrounding rock relaxation pressure. And the analytical solution for surrounding rock relaxation pressure is derived. For such tunnels, their surrounding rock has sliding rupture planes that generally follow a "W" shape. The failure area is determined by the rupture angles. Research shows that for shallow-buried bilateral bias twin-tube tunnel under the action of seismic force, the load effect on the tunnel structure shall be studied based on the relaxation pressure induced by surrounding rock failure. The rupture angles between the left tube and the right tube are independent of the surface slope. For tunnels with surrounding rock of Grade IV, V and VI, which is of poor quality, the recommended reinforcement range for the rupture angles is provided when the seismic fortification intensity is VI, VII, VIII and IX respectively. This study is expected to provide theoretical support regarding the ground reinforcement range for the shallow-buried bilateral bias twin-tube tunnel under seismic force.

Experimental study on the ground arching depending on the deformation type of the crown in the shallow tunnel (얕은터널에서 천단의 변형형태에 따른 그라운드 아칭에 관한 실험적 연구)

  • Yim, Il Jae;Lee, Sang Duk
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.5
    • /
    • pp.733-747
    • /
    • 2017
  • In the shallow tunnel, the surrounding ground could be loosened and deformed, which could be the cause of stress change in the ground. Terzaghi has clarified the development of a ground arching induced by the deformation of a tunnel crown in the trap door tests. However, he considered only the case in which that the tunnel crown deformed uniformly. He did not consider the effect of deformation shapes. Therefore, the relation between the shape of the ground relaxation above the tunnel crown and the deformation shape of the tunnel crown is not clear yet. In this study, model tests were performed for the three types of the tunnel crown, such as uniform, concave and convex shapes. As results, it was found that the vertical load would be transferred in various types depending on the deformation shapes of the tunnel crown.

A Case Study on Reinforcement of Ground and Foundation against Subsidence in Abandoned Mining Area (폐광지역 침하방지를 위한 지반 및 구조물기초 보강)

  • Kim, Do-Hyung;Choi, Chang-Rim;Kim, Dong-Hyun;Lee, Du-Hwa;Lee, Baek-Song;Je, Hae-Chan
    • Tunnel and Underground Space
    • /
    • v.17 no.4
    • /
    • pp.255-265
    • /
    • 2007
  • As the mechanism and effect range of subsidence are altered according to the various conditions (the ground condition, the earth pressure, the geometric condition of underground cavity and the structure load), the analysis and prediction of subsidence in abandoned mining area are very difficult. Also, as the geological characteristics and the mining methods are differed in each mines, the application of the pre-existing reinforcements without improvement has a lot of difficulties and limits. In this study, the various underground investigation such as long-depth core drilling, seismic tomography and BIPS (borehole image processing system) were performed, the distribution of underground cavity and coal seam and rock relaxation condition were analyzed. And we predicted the type of subsidence and estimated the subsidence by theories of mining subsidence. With these results, we analyzed the mechanism of subsidence occurrence in the research object area. Finally, we improved existing methods which were applied to the abandoned mining area and also we established the rational reinforcement for the ground and structure foundation against each subsidence cause.

Behavior Characteristics of Precast Concrete-Panel Retaining Wall Adhered to In-situ Ground through Large Scaled Load Test (대형재하시험을 통한 원지반 부착식 패널옹벽의 거동특성)

  • Shin, Yuncheol;Min, Kyongnam;Kim, Jinhee;Ahn, Taebong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.11
    • /
    • pp.45-53
    • /
    • 2016
  • A precast panel wall system resists against the horizontal earth pressure by increasing the shear strength of ground by reinforcement connected to the panel. The application of precast panel wall system is growing to lately minimize the earth work and environmental damage caused by large cut slope and to use the limited land effectively. The ground adhered panel wall system is the construction method that has the panel engraved with natural rock shape to improve the landscape. This system is developed to complete Top-Down method, and it is possible to have vertical cut, and to adhere to in-situ ground, improve construction ability by minimizing the ground relaxation and exclusion the trench and backfill process. In this study the field tests were performed to verify the construction ability about the vertical cut and complete Top-Down process and the construction behavior of ground adhered panel wall system was analyzed by large scale loading test and measurement results during loading test.