• Title/Summary/Keyword: Relative signal intensity

Search Result 64, Processing Time 0.025 seconds

Quantitative Analysis of Cerebellar Cortical Degeneration Using MRI in Dogs

  • Seok-Min Lee;A-Rim Lee;Young-Won Lee;Ho-Jung Choi
    • Journal of Veterinary Clinics
    • /
    • v.40 no.3
    • /
    • pp.225-229
    • /
    • 2023
  • In three dogs showing cerebellar ataxia, the onset of clinical signs varied from a young age of five months to age 13 years. Qualitative magnetic resonance imaging (MRI) revealed various degrees of cerebellar atrophy, and a tentative diagnosis of cerebellar cortical degeneration was made. Quantitative analysis using the brainstem to the cerebellar cross-sectional area ratio (BS:CBM ratio) and T2-signal intensity histograms were obtained to perform an objective evaluation. These techniques have the advantage of being easy and fast to evaluate. These quantitative analyses revealed the severity of cerebellar cortical degeneration in the three dogs as mild, moderate, and severe. Dogs 2 and 3 were identified as abnormal on the relative cerebrospinal fluid (CSF) space using T2-signal intensity histograms but were normal on the BS:CBM ratio. This suggests that the T2-signal intensity histograms may have higher sensitivity than BS:CBM ratio.

A study on the temperature distribution measurement of the high pressure mercury lamp (고압 수은등의 온도분포 측정에 대한 연구)

  • 손승현;김상용;김창섭;지철근
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1990.10a
    • /
    • pp.35-40
    • /
    • 1990
  • Temperature distribution of high pressure mercury lamp has been mesured as a function of time using spectroscopic method. Sampling signal which is synchronized by lamp voltage was used to mesure temporal line intensity at each radius. To obtain radial temprature distribution, the mesured intensity was transformed into radial line intensity by Abel's formula. Absolute temperature profile was calculater from relative intensities of spectral lines as a function of line and tube radius. The temperature profile is very similar to the electrical tube current profile.

  • PDF

Tunable laser source using a self-seeding FP-LD (Self-seeding FP-LD을 이용한 파장 가변 레이저 광원)

  • Kim, Jung-Min;Lee, Hyuek-Jae
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.3
    • /
    • pp.104-109
    • /
    • 2021
  • In this paper, we experimentally demonstrate a self-seeding FP-LD (Fabry Perot Laser Diode) to verify the possibility of a new tunable light source that can be used in WDM-PON (Wavelength Division Multiplexing - Passive Optical Network) system. The conventional implementation of WDM-PON using a tunable light source has a disadvantage that the center wavelength of the AWG (Arrayed Waveguide Grating) device and the tunable light source must be precisely aligned. However, the proposed tunable light source has the advantage that the tunable wavelength is automatically aligned with the center wavelength of the AWG as well as simple structure. The implemented tunable light source had a tunable band of about 14 nm or more, and the maximum RIN (Relative Intensity Noise) of about -124 dB/Hz, which showed the possibility of modulating 10 Gb/s signal by an external modulator.

Application of a Membrane Desolvator to the Analysis of Organic Solvents in Inductively Coupled Plasma Atomic Emission Spectrometry

  • Lee, J. S.;Lim, H. B.
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.9
    • /
    • pp.1040-1044
    • /
    • 1999
  • A micro porous PTFE membrane desolvator (MMD) was built and evaluated for the on-line removal of organic solvents to facilitate the determination of trace metal contaminants in the solvents by ICP-AES. Three organic solvents, isopropyl alcohol (IPA), methanol, and dimethy sulfoxide (DMSO) were studied. The MMD reduced organic solvent concentration in the sample aerosol stream by 82% to 89%, as indicated by monitoring C(I) emission. Net signal intensity of Fe, Al, and Cu was increasing with higher organic solvent concentration, with the rate of increase being solvent dependent. The signal intensities for Mg and Pb followed the trend with the C(I) signal. Changing the sweep gas flow rate affected the optimum signal intensity. Wine samples were analyzed by the method of standard addition. The concentrations of B, Al, and Mg were determined with a relative precision of less than 2.3%.

The Relationship between Temporomandibular joint Pain and the Relative Signal Intensity of Retrodiscal Tissue on T1-, and T2-Weighted MRI Images (원판후조직의 T1, T2 강조영상상의 상대적 신호강도와 관절통증의 상관관계)

  • Jung, Jae-Kwang;Hur, Yun-Kyung;Choi, Jae-Kap
    • Journal of Oral Medicine and Pain
    • /
    • v.36 no.3
    • /
    • pp.177-185
    • /
    • 2011
  • Aims: The purpose of this study was to evaluate the relationship between temporomandibular joint pain and the relative signal intensity (RSI) of retrodiscal tissue on T1-, and T2-weighted MRI images. Materials and Methods: This study was based on 122 TMJs of 61 patients who complain of TMJ pain in only one side but were revealed to have disc displacement in both TMJs according to MRI findings. The signal intensities of regions of interest (ROIs) in retrodiscal tissues were measured using T1-, and T2-weighted MRI images. The RSIs of retrodiscal tissues were referenced to the signal intensities of the ROIs of brain gray matter. The relationships between the RSI of retrodiscal tissue and joint pain, joint effusion, condylar degenerative change, and degree of disc displacement were examined. In addition, the relationships between joint pain and joint effusion, condylar degenerative change, and degree of disc displacement were examined. Results: On T1-weighted MR images, the painful TMJs showed significantly higher retrodiscal tissue RSI than non-painful TMJs. In addition, there is an association between joint pain and the degree of disc displacement. However, on T2-weighted MR images, the RSIs of retrodiscal tissues didn't show any significant differences with regard to joint pain, joint effusion, condylar degenerative change, and degree of disc displacement. Conclusions: The signal intensity of retrodiscal tissue can be used as a diagnostic marker for painful TMJ. However, the overall results suggest the signal intensity of retrodiscal tissue has a limited diagnostic significance in determining the pathologic status of TMJ.

Relative Intensity Noise Suppression of Spectrum-Sliced Channels Using Polarization-Independent Optical Modulators

  • Kim, Hyung Hwan;Manandhar, Dipen;Lee, Jae Seung
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.6
    • /
    • pp.646-649
    • /
    • 2014
  • Performances of spectrum-sliced channels are strongly affected by their relative intensity noise (RIN). We use polarization-independent optical modulators (PIOMs) for spectrum-sliced channels to suppress their RIN. The PIOM driven by a high sinusoidal voltage signal evenly redistributes optical frequency components in the spectral domain and reduces the RIN. It can be used at a broadband light source (BLS) output to produce spectrum-sliced channels having lower RIN values. Also, it can be used for each spectrum-sliced channel within each optical network unit (ONU). In our experiment, where 12.5-GHz-spaced spectrum-sliced channels are used in 1-GbE speed, the use of PIOM at the BLS output reduces the bit error rate (BER) of the spectrum-sliced channel by more than an order of magnitude. The use of PIOM within the ONU reduces the BER by approximately 3 orders of magnitude.

The usability of the MR Breast perfusion image and Time-Signal Intensity curve in Breast cancer patients (유방암 환자에서 MR Breast perfusion 영상과 시간-신호강도 곡선의 유용성)

  • Cho, Jae-Hwan;Lee, Hae-Kag
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.9
    • /
    • pp.4068-4074
    • /
    • 2011
  • The purpose of this study was to examine the usefulness of MR Breast perfusion image and time-signal intensity curve in patients diagnosed with breast cancer. We selected on 20 patients who were histologically diagnosed to have invasive ductal carcinoma (IDC) from March 2009 to December 2010. First, the Breast perfusion mapping image was reconstructed after obtaining the dynamic contrast enhancement image. The reconstructed image measured the slope, maximal relative enhancement, and time to peak on the detail including the lesion region, normal region, back ground region after obtaining the time-signal intensity curve. The lesion region and normal and slope of the back ground part were measured with the quantitive analytical method about the research and the average was compared and was analyze. In the qualitative analysis, the signal strength of each pixel was analyze with the macroscopic and being high it was low, the medium (2) performed the division of (a) by the three-point standard and the average was measured. The findings from the quantitative image analysis are the following: In the lesion region, the slope and maximal relative enhancement were the highestest among and the time to peak was the highestest in the back ground region. In the qualitative analysis, the breast perfusion image showed a diagnostic efficiency.

Diffusion-Weighted MR Imaging in Biopsy-Proven Creutzfeldt-Jakob Disease

  • Hyo-Cheol Kim;Kee-Hyun Chang;In Chan Song;Sang Hyun Lee;Bae Ju Kwon;Moon Hee Han;Sang-Yun Kim
    • Korean Journal of Radiology
    • /
    • v.2 no.4
    • /
    • pp.192-196
    • /
    • 2001
  • Objective: To compare conventional and diffusion-weighted MR imaging in terms of their depiction of the abnormalities occurring in Creutzfeldt-Jakob disease. Materials and Methods: We retrospectively analyzed the findings of conventional (T2-weighted and fluid-attenuated inversion recovery) and diffusion-weighted MR imaging in four patients with biopsy-proven Creutzfeldt-Jakob disease. The signal intensity of the lesion was classified by visual assessment as markedly high, slightly high, or isointense, relative to normal brain parenchyma. Results: Both conventional and diffusion-weighted MR images demonstrated bilateral high signal intensity in the basal ganglia in all four patients. Cortical lesions were observed on diffusion-weighted MR images in all four, and on fluid-attenuated inversion recovery MR images in one, but in no patient on T2-weighted images. Conventional MR images showed slightly high signal intensity in all lesions, while diffusion-weighted images showed markedly high signal intensity in most. Conclusion: Diffusion-weighted MR imaging is more sensitive than its conventional counterpart in the depiction of Creutzfeldt-Jakob disease, and permits better detection of the lesion in both the cerebral cortices and basal ganglia.

  • PDF

Pseudo Optical PAM-N Signal Using Externally Modulated Lasers

  • Huh, Joon Young;Lee, Joon Ki;Kang, Sae-Kyoung;Lee, Jyung Chan
    • ETRI Journal
    • /
    • v.37 no.6
    • /
    • pp.1120-1128
    • /
    • 2015
  • We propose a pseudo optical N-level pulse-amplitude modulation (PO PAM-N) signal using a few externally-modulated lasers (EMLs) operating at different wavelengths, which is suitable for upgrading the transmission speed over an optical link of < 10 km single-mode fiber with low-cost components. To compare a PO PAM-N signal with that of a standard optical PAM-N signal, we perform experiments for evaluating the performance of a 51.56-Gb/s PO PAM-4 signal and standard 51.56-Gb/s optical PAM-4 signal. The receiver sensitivity (at $BER=10^{-5}$) of the PO PAM-4 signal is 1.5 dB better than the receiver sensitivity of a standard optical PAM-4 signal. We also investigate the feasibility of PO PAM-N (N = 4, 8, and 16) signals operating at 103.12 Gb/s, considering relative intensity noise, timing jitter, extinction ratio (ER) of EMLs, and dispersion. From the results, a PO PAM-8 signal performs better than PO PAM-4 and PO PAM-16 signals at 103.12 Gb/s. Finally, we suggest a timing control method to suppress the effect of dispersion in a PO PAM-N signal. We show that the tolerance to dispersion of a 103.12-Gb/s PO PAM-8 signal can be improved to ${\pm}40ps/nm$ by applying a proposed scheme.

NO measurements in lean and soot flame using KrF laser (KrF 레이저를 이용한 희박연소화염과 매연화염에서의 NO계측)

  • 손성민;고동섭;이중재;오승묵;강건용;김종욱
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.3
    • /
    • pp.177-183
    • /
    • 2001
  • The KrF laser was employed to study NO fluorescence in lean-bum as well as in soot-bum flames. Blue-shifted NO fluorescence was observed in both of the flames. For both of the flames, the fluorescence intensity of NO and its relative background noise signal were measured with respect to the concentration of seeded NO molecule in the flame and the laser intensity. The results were analyzed qualitatively. Also, NO concentration distribution in the lean-bum flame was qualitatively determined from the intensity of the NO fluorescence. cence.

  • PDF