• Title/Summary/Keyword: Relative Histogram

Search Result 77, Processing Time 0.024 seconds

Joint Quality Control of MPEG-2 Video Programs for Digital Broadcasting Services (디지털 방송 서비스를 위한 MPEG-2 비디오 프로그램들의 결합 화질 제어)

  • 홍성훈;김성대
    • Journal of Broadcast Engineering
    • /
    • v.3 no.1
    • /
    • pp.69-84
    • /
    • 1998
  • In digital broadcasting, services such as digital satellite TV, cable TV and digital terrestrial TV, several video programs are compressed by MPEG-2, and then simultaneously transmitted over a conventional CBR (Constant Bit Rate) broadcasting channel. In this paper, we propose a joint quality control scheme to be able to accurately control the relative picture quality among the video programs, which is achieved by simdt;,nL'Ously controlling the video encoders to generate the VBR (Variable Bit Rate) compressed video streams. Our quality control scheme can prevent the video buffer overflow and underflow by total target bit allocation process, and also exactly control the relative picture quality in terms of PSNR (Peak Signal to Noise Ratio) between some programs requiring higher picture quality and others by rate-distortion modification. Furthermore we present a rate-distortion estimation method for MPEG-2 video, which is base of our joint quality control, and verify its performance by experiments. The most attractive features of this estimation method are as follows: 1) computational complexity is low because main operation for the estimation is to calculate the histogram of OCT coefficients into quantizer; 2) estimation results are very accurate enough to be applied to the practical MPEG-2 video coding applications. Simulation results show that the proposed joint quality control scheme accurately controls the relative picture quality among the video progran1s transmitted over a single channel as well as provides more consistent and higher picture quality than independent coding scheme that encodes each program independently.

  • PDF

Fabrication of Bendable Gd2O2S:Tb Intensifying Screen and Evaluation of Fatigue Properties (유연한 Gd2O2S:Tb 증감지 제작 및 피로누적에 대한 영향)

  • Park, Ji-Koon;Yang, Sung-Woo;Jeon, Je-Hoon;Kim, Joo-Hee;Heo, Ye-Ji;Kang, Sang-Sik;Kim, Kyo-Tae
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.611-617
    • /
    • 2017
  • In this study, it was expected that long-term stability against external mechanical external force could be secured if the phosphor layer had ductility. In this study, a bendable $Gd_2O_2S:Tb$ sensitized paper was fabricated by screen printing method and the image uniformity was evaluated through RMS analysis and histogram analysis to investigate the effect of fatigue accumulation due to long-term external force and repetitive external force. As a result, the dominant pixel area is maintained constant and the relative standard deviation is less than 10% for the long-term external force. However, for the repetitive external force, the dominant pixel area is divided into three areas and the image uniformity is adversely affected. Based on these results, it is suggested that the curved surface detector can be applied by securing the mechanical stability against the existing radiation sensitized paper. However, further studies are needed to apply it to the flexible detector. As a result, flexible radiation sensitizers can be applied to various curved surfaces, and it is expected to be applicable to various fields such as nuclear medicine, medical treatment, and industrial fields in the future.

Extraction of Muscle Areas from Ultrasonographic Images using Information of Fascia (근막 정보를 이용한 초음파 영상에서의 근육 영역 추출)

  • Kim, Kwang-Baek
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.9
    • /
    • pp.1296-1301
    • /
    • 2008
  • Ultrasonography constructs pictures of areas inside the body needs in diagnosis by bouncing high-enorgy sound waves(ultrasound) off internal tissues or organs. In constructing an ultrasonographic image, the weakness of bounding signals induces noises and detailed differences of brightness, so that having a difficulty in detecting and diagnosing with the naked eyes in the analysis of ultrasonogram. Especially, the difficulty is extended when diagnosing muscle areas by using ultrasonographic images in the musculoskeletal test. In this paper, we propose a novel image processing method that computationally extracts a muscle area from an ultrasonographic image to assist in diagnosis. An ultrasonographic image consists of areas corresponding to various tissues and internal organs. The proposed method, based on features of intensity distribution, morphology and size of each area, extracts areas of the fascia, the subcutaneous fat and other internal organs, and then extracts a muscle area enclosed by areas of the fascia. In the extraction of areas of the fascia, a series of image processing methods such as histogram stretching, multiple operation, binarization and area connection by labeling is applied. A muscle area is extracted by using features on relative position and morphology of areas for the fascia and muscle areas. The performance evaluation using real ultrasonographic images and specialists' analysis show that the proposed method is able to extract target areas being approximate to real muscle areas.

  • PDF

SOSiM: Shape-based Object Similarity Matching using Shape Feature Descriptors (SOSiM: 형태 특징 기술자를 사용한 형태 기반 객체 유사성 매칭)

  • Noh, Chung-Ho;Lee, Seok-Lyong;Chung, Chin-Wan;Kim, Sang-Hee;Kim, Deok-Hwan
    • Journal of KIISE:Databases
    • /
    • v.36 no.2
    • /
    • pp.73-83
    • /
    • 2009
  • In this paper we propose an object similarity matching method based on shape characteristics of an object in an image. The proposed method extracts edge points from edges of objects and generates a log polar histogram with respect to each edge point to represent the relative placement of extracted points. It performs the matching in such a way that it compares polar histograms of two edge points sequentially along with edges of objects, and uses a well-known k-NN(nearest neighbor) approach to retrieve similar objects from a database. To verify the proposed method, we've compared it to an existing Shape-Context method. Experimental results reveal that our method is more accurate in object matching than the existing method, showing that when k=5, the precision of our method is 0.75-0.90 while that of the existing one is 0.37, and when k=10, the precision of our method is 0.61-0.80 while that of the existing one is 0.31. In the experiment of rotational transformation, our method is also more robust compared to the existing one, showing that the precision of our method is 0.69 while that of the existing one is 0.30.

Spatiotemporal Analysis of Ship Floating Object Accidents (선박 부유물 감김사고의 시·공간적 분석)

  • Yoo, Sang-Lok;Kim, Deug-Bong;Jang, Da-Un
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.7
    • /
    • pp.1004-1010
    • /
    • 2021
  • Ship-floating object accidents can lead not only to a delay in ship's operations, but also to large scale casualties. Hence, preventive measures are required to avoid them. This study analyzed the spatiotemporal aspects of such collisions based on the data on ship-floating object accidents in sea areas in the last five years, including the collisions in South Korea's territorial seas and exclusive economic zones. We also provide basic data for related research fields. To understand the distribution of the relative density of accidents involving floating objects, the sea area under analysis was visualized as a grid and a two-dimensional histogram was generated. A multinomial logistic regression model was used to analyze the effect of variables such as time of day and season on the collisions. The spatial analysis revealed that the collision density was highest for the areas extending from Geoje Island to Tongyeong, including Jinhae Bay, and that it was high near Jeongok Port in the West Sea and the northern part of Jeju Island. The temporal analysis revealed that the collisions occurred most frequently during the day (71.4%) and in autumn. Furthermore, the likelihood of collision with floating objects was much higher for professional fishing vessels, leisure vessels, and recreational fishing vessels than for cargo vessels during the day and in autumn. The results of this analysis can be used as primary data for the arrangement of Coast Guard vessels, rigid enforcement of regulations, removal of floating objects, and preparation of countermeasures involving preliminary removal of floating objects to prevent accidents by time and season.

Development of Preliminary Quality Assurance Software for $GafChromic^{(R)}$ EBT2 Film Dosimetry ($GafChromic^{(R)}$ EBT2 Film Dosimetry를 위한 품질 관리용 초기 프로그램 개발)

  • Park, Ji-Yeon;Lee, Jeong-Woo;Choi, Kyoung-Sik;Hong, Semie;Park, Byung-Moon;Bae, Yong-Ki;Jung, Won-Gyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.113-119
    • /
    • 2010
  • Software for GafChromic EBT2 film dosimetry was developed in this study. The software provides film calibration functions based on color channels, which are categorized depending on the colors red, green, blue, and gray. Evaluations of the correction effects for light scattering of a flat-bed scanner and thickness differences of the active layer are available. Dosimetric results from EBT2 films can be compared with those from the treatment planning system ECLIPSE or the two-dimensional ionization chamber array MatriXX. Dose verification using EBT2 films is implemented by carrying out the following procedures: file import, noise filtering, background correction and active layer correction, dose calculation, and evaluation. The relative and absolute background corrections are selectively applied. The calibration results and fitting equation for the sensitometric curve are exported to files. After two different types of dose matrixes are aligned through the interpolation of spatial pixel spacing, interactive translation, and rotation, profiles and isodose curves are compared. In addition, the gamma index and gamma histogram are analyzed according to the determined criteria of distance-to-agreement and dose difference. The performance evaluations were achieved by dose verification in the $60^{\circ}$-enhanced dynamic wedged field and intensity-modulated (IM) beams for prostate cancer. All pass ratios for the two types of tests showed more than 99% in the evaluation, and a gamma histogram with 3 mm and 3% criteria was used. The software was developed for use in routine periodic quality assurance and complex IM beam verification. It can also be used as a dedicated radiochromic film software tool for analyzing dose distribution.

Relative Radiometric Normalization of Hyperion Hyperspectral Images Through Automatic Extraction of Pseudo-Invariant Features for Change Detection (자동 PIF 추출을 통한 Hyperion 초분광영상의 상대 방사정규화 - 변화탐지를 목적으로)

  • Kim, Dae-Sung;Kim, Yong-Il
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.26 no.2
    • /
    • pp.129-137
    • /
    • 2008
  • This study focuses on the radiometric normalization, which is one of the pre-processing steps to apply the change detection technique fur hyperspectral images. The PIFs which had radiometric consistency under the time interval were automatically extracted by applying spectral angle, and used as sample pixels for linear regression of the radiometric normalization. We also dealt with the problem about the number of PIFs for linear regression with iteratively quantitative methods. The results were assessed in comparison with image regression, histogram matching, and FLAASH. In conclusion, we show that linear regression method with PIFs can carry out the efficient result for radiometric normalization.

Retinex-based Logarithm Transformation Method for Color Image Enhancement (컬러 이미지 화질 개선을 위한 Retinex 기반의 로그변환 기법)

  • Kim, Donghyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.9-16
    • /
    • 2018
  • Images with lower illumination from the light source or with dark regions due to shadows, etc., can improve subjective image quality by using retinex-based image enhancement schemes. The retinex theory is a method that recognizes the relative lightness of a scene, rather than recognizing the brightness of the scene. The way the human visual system recognizes a scene in a specific position can be in one of several methods: single-scale retinex, multi-scale retinex, and multi-scale retinex with color restoration (MSRCR). The proposed method is based on the MSRCR method, which includes a color restoration step, which consists of three phases. In the first phase, the existing MSRCR method is applied. In the second phase, the dynamic range of the MSRCR output is adjusted according to its histogram. In the last phase, the proposed method transforms the retinex output value into the display dynamic range using a logarithm transformation function considering human visual system characteristics. Experimental results show that the proposed algorithm effectively increases the subjective image quality, not only in dark images but also in images including both bright and dark areas. Especially in a low lightness image, the proposed algorithm showed higher performance improvement than the conventional approaches.

Selection of Detection Measures for Malicious Codes using Naive Estimator (단순 추정량을 이용한 악성코드의 탐지척도 선정)

  • Mun, Gil-Jong;Kim, Yong-Min
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.18 no.2
    • /
    • pp.97-105
    • /
    • 2008
  • The various mutations of the malicious codes are fast generated on the network. Also the behaviors of them become intelligent and the damage becomes larger step by step. In this paper, we suggest the method to select the useful measures for the detection of the codes. The method has the advantage of shortening the detection time by using header data without payloads and uses connection data that are composed of TCP/IP packets, and much information of each connection makes use of the measures. A naive estimator is applied to the probability distribution that are calculated by the histogram estimator to select the specific measures among 80 measures for the useful detection. The useful measures are then selected by using relative entropy. This method solves the problem that is to misclassify the measure values. We present the usefulness of the proposed method through the result of the detection experiment using the detection patterns based on the selected measures.

A Case Study of Amplitude-Based Change Detection Methods Using Synthetic Aperture Radar Images (위성 레이더 영상을 활용한 강도 기반 변화탐지기술 활용 사례연구)

  • Seongjae Hong;Sungho Chae;Kwanyoung Oh;Heein Yang
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_3
    • /
    • pp.1791-1799
    • /
    • 2023
  • The Korea Aerospace Research Institute is responsible for supplying and supporting the utilization of imagery data from the Arirang satellite series for organizations affiliated with the Government Satellite Information Application Consultation. Most of them primarily utilize optical imagery, and there is a relative lack of utilization of Synthetic Aperture Radar (SAR) imagery. In this paper, as part of supporting the use of SAR images, we investigated SAR intensity-based change detection algorithms and their use cases that have been researched to determine SAR intensity-based change detection algorithms to be developed in the future. As a result of the research, we found that various algorithms utilizing intensity difference, correlation coefficients, histograms, or polarimetric information have been researched by numerous researchers to detect and analyze change pixels and the applications of change detection algorithms have been studied in various fields such as a city, flood, forest fire, and vegetation. This study will serve as a reference for the development of SAR change detection algorithms, intended for utilization in the Government Satellite Information Application Consultation.