• 제목/요약/키워드: Relative Electrode Potential

검색결과 43건 처리시간 0.023초

Real-time Voltammetric Assay of Cadmium Ions in Plant Tissue and Fish Brain Core

  • Ly, Suw-Young
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권10호
    • /
    • pp.1613-1617
    • /
    • 2006
  • Optimum analytical conditions for cyclic voltammetry (CV) and square wave (SW) stripping voltammetry were determined using mercury-mixed carbon nanotube paste electrode (PE). The results approached the microgram working ranges of SW: 10.0-80.0 $ugL^{-1}$ and CV: 100-700 $ugL^{-1}$ Cd (II); working conditions of 300-Hz frequency, 100 mV amplitude, 1.6 V accumulation potential, 400 sec accumulation time, and 40 mV increment potential. First, analysis was performed through direct assay of cadmium ions deep into the fishs brain core and plant tissue in real time with a preconcentration time of 400 sec. The relative standard deviation of 10.0 $mgL^{-1}$ Cd (II) observed was 0.064 (n = 12) at optimum conditions. The low detection limit (S/N) was set at 0.6 $ugL^{-1}$ ($5.33{\times}10^{-9}$ M). The methods can be used in direct analysis in vivo or in real-time monitoring of plant tissue.

1-(2-Pyridylazo)-2-naphthol 수식전극을 사용한 Cu(II) 이온의 전압전류법적 정량 (Voltammetric Determination of Cu(II) Ion at a Chemically Modified Carbon-Paste Electrode Containing 1-(2-pyridylazo)-2-naphthol)

  • 배준웅;전희숙;장혜영
    • 대한화학회지
    • /
    • 제37권8호
    • /
    • pp.723-729
    • /
    • 1993
  • 탄소분말과 Nujol oil의 carbon paste 혼합물에 1-(2-pyridylazo)-2-naphthol (PAN)을 섞어서 Cu(Ⅱ)이온에 감응하는 수식전극을 제작하였다. Cu(II) 이온이 포함된 완충용액에 전극을 담구어 전위를 가하지 않고 PAN-수식전극의 표면에 Cu(II) 이온을 석출시킨 후, 전해액으로 옮겨 일정시간 동안 일정 전위에서 환원시켰다. 그런 다음 양의 방향으로 전위를 주사함으로써 좋은 전압전류파를 얻을 수 있었다. 전극표면을 산용액에 담금으로써 재생시킬 수 있었다. 전극의 재현성은 석출/측정/재생의 순으로 5회 반복실험하여 조사한 결과 상대표준편차는 6.1${\%}$였다. 시차펄스 전압전류법으로 조사한 경우 2.0 ${times}$ 10$^{-7}$M에서 1.0 ${times}$ 10$^{-6}$ M의 농도 범위에 걸쳐 직선성이 성립했으며, 검출한계는 6.0 ${times}$ 10$^{-8}$ M이었다. Cu(II) 이온을 정량하는데 있어서 EDTA와 oxalate 이온을 제외한 다른 공존이온의 영향을 별로 받지 않았다.

  • PDF

고 선택성 수은(II) 이온 막 센서 (A Highly Selective Mercury(II) Ion-Selective Membrane Sensor)

  • Ensafi, Ali A.;Meghdadi, S.;Allafchian, Ali R.
    • 대한화학회지
    • /
    • 제51권4호
    • /
    • pp.324-330
    • /
    • 2007
  • 수은(II) 이온 센서로 이온투과 담체로서 bis(benzoylacetone) propylenediimine (H2(BA)2PD)을 근간으로 하는 새로운 이온 선택 PVC 막 전극이 개발하였다. 이 전극은 좋은 감응 특성을 보였고, 29.8±0.75 mV/10의 Nernstian 기울기로 부터 1.0×10-6-1.0×10-1 M 수은(II) 이온 농도 범위에서 선형 Emf vs. log[Hg2+]를 보였다. pH 2.5-11.5에서 검출한계는 2.2×10-7 M Hg(II)를 보였다. 다수의 전위 간섭이온에의 수은(II)이온 대한 선택 농도에 대해 역시 연구되었다. 이 센서는 다른 전하와 함께 많은 수의 양이온에 있어 수은(II)이온에 대해 고선택성을 보였다. 이 센 서는 60초 안에 빠는 감응을 보이며 화학적으로 불활성인 것을 알아 내었고 3개월 동안 좋은 재현성을 보였다(S = 0.27 mV). 이 전극은 실제 시료에서 수은(II)이온 의 분석에 대해 서도 만족할 만한 결과를 얻었다.

OLED 증착용 정전척 개발을 위한 척킹력 분포와 변화 특성 연구 (Investigation of Chucking Force Distribution and Variation Characteristics for the Development of ESC in OLED Deposition)

  • 임충환;민동균;김성빈
    • 반도체디스플레이기술학회지
    • /
    • 제22권3호
    • /
    • pp.14-20
    • /
    • 2023
  • The electrostatic chuck is a technology that uses electroadhesion to attach objects and is widely used in semiconductor and display processes. This research conducted Maxwell by varying parameters to examine the distribution and variations of chucking force in a bipolar-type ESC. The parameters that were changed include the material properties of the dielectric layer and attachment substrate, applied voltage to the electrode, and the gap and width between the electrodes. The analysis results showed that as the relative permittivity of the dielectric layer and substrate increased, the chucking force also increased, with the relative permittivity of the substrate having a greater impact on the chucking force. And increasing the applied voltage led to an increase in both the chucking force and its rate of change. Lastly, as the gap between the electrodes increased, the chucking force rapidly decreased until a certain distance, after which the decrease became less significant. On the contrary, increasing the electrode width resulted in a rapid increase in the chucking force until a certain width, beyond which the increase became less pronounced, eventually converging to a chucking force of 1700 Pa. This paper is expected to have high potential for the development and research of ESC for OLED deposition.

  • PDF

진공 인터럽터의 3차원 유한요소해석 (Three-Dimensional Finite Element Analysis of a Vacuum Interrupter)

  • 최승길;강형부
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권10호
    • /
    • pp.693-698
    • /
    • 1999
  • Vacuum interrupters have a special asymmetric electrode structure to generate an magnetic field and consequently to increase the interrupting ability. Accordingly 2-dimensional analysis has a large analysis error because radial flux can not be considered. In this paper, in order to analyse the electric field distribution of a vacuum interrupter with arc shield more accurately, 3-dimensional finite element method(FEM) is used. The induced electric potentials of floating shield was increased with the gap distance, which is because the relative position of shield is closer to the fixed contact so that the capacitance distribution inside interrupter is varied. The calculated results also show that the induced potential of shield causes electric field distortion so that the maximum value of electric field in a vacuum interrupter with arc shield is higher than that without one.

  • PDF

Analysis of Lead Ions in a Waste Solution Using Infrared Photo-Diode Electrode

  • Ly, Suw-Young;Lee, Hyun-Kuy;Kwak, Kyu-Ju;Ko, Jun-Seok;Lee, Jeong-Jae;Cho, Jin-Hee;Kim, Ki-Hong;Kim, Min-Seok;Lee, So-Jung
    • Toxicological Research
    • /
    • 제24권3호
    • /
    • pp.227-233
    • /
    • 2008
  • To detect lead ions using electrochemical voltammetric analysis, Infrared Photo-Diode Electrode(IPDE) was applied via cyclic and square wave stripping voltammetry. Lead ions were deposited at 0.5 V(versus Ag/AgCl) accumulation potential. Instrumental measurements systems were made based on a simple and compact detection system. The stripping voltammetric and cyclic voltammetric optimal parameters were searched. The results yielded a cyclic range of $40{\sim}240mgl^{-1}$ Pb(II) and a square wave stripping working range of $0.5{\sim}5.00mgl^{-1}$ Pb(II). The relative standard deviation at 2 and 4 $mgl^{-1}$ Pb(II) was 0.04% and 0.02%(n=15), respectively, using the stripping voltammetric conditions. The detection limit was found to be 0.05 $mgl^{-1}$ with a 40 sec preconcentration time. Analytical interference ions were also evaluated. The proposed method was applied to determine lead ions in various samples.

무기 금속 고분자 막을 도포시킨 유리질 탄소전극을 이용한 메탄올과 L-ascorbic acid의 양극 산화 거동에 관한 연구 (Studies on the Anodic Oxidation Behavior of Methanol and L-Ascorbic Acid by Using Glassy Carbon Electrodes Modified with Inorganic-Metal Polymeric Films)

  • 유광식;우상범
    • 분석과학
    • /
    • 제11권5호
    • /
    • pp.347-352
    • /
    • 1998
  • 본 연구에서는 유리질 탄소 전극 표면에 혼성원자가를 가지는 무기 금속 고분자 막을 도포한 변형전극을 제조하고, 이들 변형전극의 전기화학적인 특성을 순환 전압 전류법으로 조사하였다. 그리고 이들 변형전극들을 작업전극으로 하여 메탄올과 L-ascorbic acid의 양극산화 거동을 조사하였다. Mixed valence rethenium oxo/cyanoruthenate(mv Ru-O/CN-Ru) 막, mv ruthenium oxo/cyanoferrate(mv Ru-O/$Fe(CN)_6$) 막, 및 mv ruthenium oxo/cyanoruthenate/Rhodium(mv Ru-O/CN-Ru/Rh) 막을 각각 도포하는 과정은 지정된 전위범위를 50 mV/sec의 주사속도로 전위를 걸어줌으로써 쉽게 도포할 수 있었으며, 동일한 과정을 반복 주사함으로써 막의 두께를 조절 하였다. 메탄올의 양극 산화거동을 조사한 결과는 다음과 같았다. mv Ru-O/CN-Ru 변형전극에서 메탄올의 검정곡선은 농도 기울기가 $-7.552{\mu}A/mM$로서 10 mM에서 80 mM 까지의 농도범위에서 비교적 좋은 감도를 보였다. mv Ru-O/$Fe(CN)_6$ 변형 전극의 경우에 농도 기울기는 $-5.13{\mu}A/mM$ 이었지만, 농도에 대한 전류관계의 직선 범위는 10 mM에서 100 mM까지로서 Ru 고분자 막 변형전극보다 더 넓은 범위에서 좋은 직선관계를 보였다. mv Ru-O/CN-Ru 막을 두 종류의 바탕전극에 각각 도포한 변형전극에 대하여 L-ascorbic acid의 양극 산화거동을 조사한 결과, 유리질 탄소 전극에 Ru 고분자 막을 입힌 변형전극이 Rh 막을 도포한 유리질 탄소전극에 Ru 고분자 막을 입힌 변형전극(mv Ru-O/CN-Ru/Rh)에서 보다 감도가 예민하였다. Ru 고분자 막 변형전극을 사용했을 경우에 검정곡선은 0.1 mM에서 5 mM 까지의 L-ascorbic acid 농도 범위에서 직선관계를 보였고, 기울기와 상관계수는 각각 $-84.78{\mu}A/mM$, 0.998이었다.

  • PDF

Alga변성전극을 이용한 Cadmium(Ⅱ)의 양극벗김 전압-전류법적 정량 (Anodic Stripping Voltammetric Determination of Cadmium(Ⅱ) Using Alga-Modified Carbon Paste Electrodes)

  • 배준웅;최정은;장혜영
    • 대한화학회지
    • /
    • 제42권1호
    • /
    • pp.28-35
    • /
    • 1998
  • Alga와 같은 미생물은 중금속을 흡수한다. Alga(Anabaena)로 변성시킨 탄소반죽전극으로 Cd(Ⅱ)이온을 사전농축시켜서 Cd(Ⅱ)을 양극벗김 펄스차이 전압-전류법으로 정량하였다. Cd(Ⅱ)의 산화봉우리는 -0.75V vs. SCE.에서 나타났으며, 이 봉우리를 이용하여 Cd(Ⅱ) 정량의 최적조건을 조사하였다. 변성전극의 제작에 미치는 alga양의 영향과 Cd(Ⅱ)의 사전농축에 미치는 pH와 이온세기, 온도 및 사전농축시간에 대한 영향을 조사하였으며. 전극표면에 사전 농축시킨 Cd(Ⅱ)이온을 전해환원시키는 시간과 전위의 영향도 조사하였다. Cd(Ⅱ)을 정량하기 위한 검정선은 $1.0{\times}10^6\;M ~ 8.0{\times}10^6\;M$범위에서 직선성(상관계수는0.9978)이 성립하였고 검출한계는 $5.0{\times}10^{-7}\;M$이었다. $7.0{\times}10^{-6}\;M$ Cd(Ⅱ)용액에서 얻은 상대표준편차는 3.1%(n=6)이었다. Alga변성전극의 사용횟수는 0.1M HCl 용액으로 전극표면을 재생시킬 때에 10회까지 연속측정이 가능하였다.

  • PDF

Alverine의 정량을 위한 Ion-Selective Electrodes (Ion-Selective Electrodes for the Determination of Alverine)

  • 이은엽;김기묘;김성진;허문희;안문규
    • 분석과학
    • /
    • 제8권1호
    • /
    • pp.79-84
    • /
    • 1995
  • Alverine에 대한 anionic counter ion으로서 acid red 97의 이용 가능성을 살펴보았다. PVC와 가소제의 비율이 같을 때 적절한 감응과 긴 수명을 나타내었으며, 검량선은 $1.0{\times}10^{-5}M$까지 직선성이었고 그 감응 기울기는 55.35mV/dec., 변동계수는 0.61이었다. Methylephedrine에 대하여는 -2.626, histidine에 대하여는 -2.216등의 선택계수를 보였고 pH 7.0~4.0에서 안정된 전위값을 얻을 수 있었다. $10^{-4}M$ 이하에서 20~30초 이내, 그 이상의 농도에서는 약 10초 이내에서 안정된 전위값을 얻을 수 있었다.

  • PDF

1,5,9,13-Tetrathiacyclohexadecane 수식전극을 사용한 Ag(I)의 전기화학적 정량 (Electrochemical Determination of Ag(I) Ion at Chemically Modified Carbon-Paste Electrode Containing 1,5,9,13-Tetrathiacyclohexadecane)

  • 하광수;장미경;서무룡
    • 분석과학
    • /
    • 제10권3호
    • /
    • pp.187-195
    • /
    • 1997
  • [16]-ane-$S_4$/탄소분말 함량비를 50%로 하여 nujol oil과 혼합하여 수식전극을 제조하였다. $5.0{\times}10^{-4}M$ $Ag^+$를 포함하는 pH 4.5인 아세트 완충용액에 수식전극을 담가 $Ag^+$를 전극 표면에 흡착시켰다. 이 때 흡착시간을 15분으로 하고 전해환원시키는 시간은 -0.3V vs S.C.E에서 2분으로 하였다. 또한 0.1M $HNO_3$ 용액으로 전극을 활성화시켰으며 한번 활성화한 전극은 10회까지 사용이 가능하였다. 최적 분석조건에서 미분펄스 전압전류법으로 $5.0{\times}10^{-7}{\sim}1.5{\times}10^{-6}M$ 사이의 농도 범위에서 정량해 보았을 때 직선성이 잘 성립하였으며, 검출한계는 $2.0{\times}10^{-7}M$이었다. 대부분의 금속들은 방해를 주지 않았으나, Cu(II)은 방해를 나타내었다.

  • PDF