• 제목/요약/키워드: Relative Capacity Index

검색결과 62건 처리시간 0.026초

국토환경성평가 지표를 이용한 환경용량 산정모델 개발 (A Development of Environmental Capacity Estimation Model Using the National Environmental Assessment Indicators)

  • 이종수;이우균;전성우
    • 환경영향평가
    • /
    • 제15권6호
    • /
    • pp.385-394
    • /
    • 2006
  • Land resources should be managed not only for human utilizations but also for environmental preservation. Based on that, environmental capacity should be estimated in both environmental and developmental ways. This study was performed for developing an estimation model for relative environmental capacity, considering both Development Tolerance Index(DTI), which shows environmental and ecological conservation value and is based on national environmental assessment indicators of the Korea Ministry of Environment, and Development Attractiveness Index(DAI), which shows topographical characteristics and geographical accessibility. The relative environmental capacity in this study can be helpful to coping with the conflict in planning and managing the use of land resources. The relative environmental capacity in this study, however, did not include either environmental or ecological sensitivity of land resources. This limitation should be solved through further research.

일부 사형의 체격 및 체력에 관한 연구 (A Study on the Physique and Bodily Strength of the Enlisted Men of Marine Corps in Korea)

  • 신영수
    • Journal of Preventive Medicine and Public Health
    • /
    • 제6권1호
    • /
    • pp.87-99
    • /
    • 1973
  • The purpose of this project is offering fundamental and proper informations for the better health control and personnel management of the enlisted men of Marine corps in Korea. Survey has been done under 1,001 marine enlisted men for the purpose of understanding their condition of physique, vital capacity, and bodily strength. 1. Under the subject of physique, 7 items, body weight, chest-girth, relative body weight, relative chest-girth, Vervaeck index, and Roehrer index are listed, and under the subject of vital capacity, BTPS vital capacity and percent predicted vital capacity are listed, and under the subject of bodily strength, 7 items, grasping power, chinning-up, throwing a hanp-grenade, forward jumping, sitting-up, 100 meter sprinting, are listed. The total items are 16 and mean score of each one is as follow. 1)Physique : a. Height : $$168{\pm}0.15cm$$ b. Body weight : $$62.7{\pm}0.17kg$$ c. Chest-girth : $$91.4{\pm}0.16cm$$ d. Relative body weight : $$37.2{\pm}0.09$$ e. Relative chest-girth : $$54.3{\pm}0.10$$ f. Vervaeck index : $$91.6{\pm}0.15$$ g. Roehrer index : $$1.31{\pm}0.003$$ 2) Vital capacity : a. BTPS vital capacity : $$4470{\pm}20cc$$ b. % Predicted vital capacity : $$150{\pm}5.1%$$ 3) Bodily strength : a. Grasping power : $$41.4{\pm}0.26kg$$ b. Chinning-up : $$5.7{\pm}0.10$$ c. Throwing a hand-grenade : $$39.7{\pm}0.20m$$ d. Forward jumping : $$214{\pm}0.58cm$$ e. Sitting-up : $$19.1{\pm}0.25$$ f. Pushing-up : $$22.1{\pm}0.18$$ g. 100 meter sprinting : $$16.1{\pm}0.04sec$$. 2. Comparative analysis has been done about the conditional classes of marine enlisted men with the results of above mentioned 16 items. 7 classes according to the branches, 3 according to the ranks, 9 according to tile length of service are adopted respectively.

  • PDF

부산지역 미세먼지에 대한 건강 취약성 평가 (Health Vulnerability Assessment for PM10 in Busan)

  • 이원정;황미경;김유근
    • 한국환경보건학회지
    • /
    • 제40권5호
    • /
    • pp.355-366
    • /
    • 2014
  • Objectives: This study seeks to evaluate the vulnerability assessment of the human health sector for $PM_{10}$, which is reflected in the regional characteristics and related disease mortality rates for $PM_{10}$ in Busan over the period of 2006-2010. Methods: According to the vulnerability concept suggested by the Intergovernmental Panel on Climate Change (IPCC), vulnerability to $PM_{10}$ is comprised of the categories of exposure, sensitivity, and adaptive capacity. The indexes of the exposure and sensitivity categories indicate positive effects, while the adaptive capacity index indicates a negative effect on vulnerability to $PM_{10}$. Variables of each category were standardized by the rescaling method, and each regional relative vulnerability was computed through the vulnerability index calculation formula. Results: The regions with a high exposure index are Jung-Gu (transportation region) and Saha-Gu (industrial region). Major factors determining the exposure index are the $PM_{10}$ concentration, days of $PM_{10}{\geq}50$, ${\mu}g/m^3$, and $PM_{10}$ emissions. The regions that show a high sensitivity index are urban and rural regions; these commonly have a high mortality rate for related disease and vulnerable populations. The regions that have a high adaptive capacity index are Jung-Gu, Gangseo-Gu, and Busanjin-Gu, all of which have a high level of economic/welfare/health care factors. The high-vulnerability synthesis of the exposure, sensitivity, and adaptive capacity indexes show that Dong-Gu and Seo-Gu have a risk for $PM_{10}$ potential effects and a low adaptive capacity. Conclusions: This study presents the vulnerability index to $PM_{10}$ through a relative comparison using quantitative evaluation to draw regional priorities. Therefore, it provides basic data to reflect environmental health influences in favor of an adaptive policy limiting damage to human health caused by vulnerability to $PM_{10}$.

액-가스 열교환기를 이용한 R170(에탄)용 냉동시스템의 성능 특성 (Performance Characteristics of Refrigerant R170(Ethane) Refrigeration System Using Liquid-gas Heat Exchanger)

  • 구학근
    • 동력기계공학회지
    • /
    • 제20권5호
    • /
    • pp.78-85
    • /
    • 2016
  • This paper considers the influence of internal heat exchangers to the efficiency of a refrigerating system using R170. These liquid-gas heat exchangers(internal or suction-line heat exchangers) can, in some cases, yield improved system performance while in other cases they degrade system performance. A steady state mathematical model is used to analysis the performance characteristics of refrigeration system with internal heat exchanger. The influence of operating conditions, such as the mass flowrate of R170, inner diameter tube and length of internal heat exchanger, to optimal dimensions of the heat exchanger is also analyzed in the paper. The main results were summarized as follows : the mass flowrate of R170, inner diameter tube and length of internal heat exchanger, and effectiveness have an effect on the cooling capacity, compressor work and RCI(Relative Capacity Index) of this system. Exception for the effect of inner diameter, the RCI of R170 with respect to refrigerant mass flowrate, the length and effectiveness of internal heat exchanger is about 2.1~3.3% higher than that of R13 at the same experimental conditions. With a thorough grasp of these effect, it is necessary to design the R170 compression refrigeration cycle using internal heat exchanger.

음이온성 Poly(bis[4-(3-aminophenoxy)phenyl]sulfone pyromellite)Imide Derivatives 한외여과막의 투과특성 (Influence of Ion Exchange Capacity on the Performance of Ultrafiltration Membrane Prepared from Anion Charged Poly(bis[4-(3-aminophenoxy)phenyl]sulfone pyromellite)imide Derivatives)

  • Jong-Young Jeon
    • 멤브레인
    • /
    • 제14권1호
    • /
    • pp.26-36
    • /
    • 2004
  • 상전환 방법으로 제조된 음이온 성 Poly(his[4-(3-aminophenoxy)phenyl]sulfone pyromellite)imide(ACPI) 한외여과막의 순수 투과유속과 용질 배재도 측정치로 투과성능을 연구하였다. ACPI 한외여과막의 투과성능은 캐스팅 용액의 조성과 막 제조 및 측정조건에 영향을 받았다. Bovine serum albumin (BSA) 용액을 pH 2.5-9.0 상태에서 ACPI 한외여과 막의 상대투과유속과 membrane filtration index (MFI) 측정한 결과 BSA의 등전점에서 멀어 질수록 상대투과유속은 증가하고 막 오염정도를 나타내는 MFI는 감소하였다. 또한, 친수성인 ACPI 한외여과막의 이온교환용량(IEC)이 증가할수록 상대투과유속은 증가하고, MFI는 감소하였다.

철골 모멘트 연결부의 구조특성에 따른 지진 거동 연구 (Seismic Behavior of Steel Moment Connections with Different Structural Characteristics)

  • 조창빈
    • 한국안전학회지
    • /
    • 제17권2호
    • /
    • pp.76-84
    • /
    • 2002
  • The seismic behaviors of steel moment connections with different structural characteristics are investigated. The rupture index, which represents the fracture potential, is adopted to study the effect of concrete slab and the relative strength between the coin the beam, and Panel zone on the ductility of connections. The results show that the presence of slab increases the beam strength, imposes constraint near the beam top flange, and consequently, induces concentrated deformation near the beam access hall, which reduces the ductility of the connection. The total deformation capacity of the connection depends not only on the beam but also on the column and panel zone. Therefore, the detrimental slab effects and the relative strength should be considered in the seismic design of the connection.

동적 상태에서 주관적 착용감에 영향을 미치는 직물의 수증기상태의 수분전달 특성 (Moisture Vapor Management Properties of Fabrics Determining Human Sensorial Comfort in Transient Conditions)

  • 유신정
    • 한국의류학회지
    • /
    • 제24권7호
    • /
    • pp.1073-1080
    • /
    • 2000
  • Moisture transfer property of fabrics has known as one of the most important factors deciding wearer's subjective comfort not only thermally but also of sensorial. As a decisive property of fabric materials in determining human sensorial comfort, moisture vapor management property of heat resistant workwear material was examined in terms of increasing and decreasing rate and maximum value of relative humidity in the microclimate under the sweat pulse situation. An unique moisture regulation index, B$_{d}$, was calculated from the measurements using a novel dynamic sweating hot plate apparatus and was used to assess the buffering capacity of fabrics against a moisture vapor sweat pulse.e.

  • PDF

환경보건적 요소가 도시 내 폭염 취약성 평가 결과에 미치는 영향 분석 (The Impact of Environmental Health Factors on Extreme-heat Vulnerability Assessment in a Metropolitan City)

  • 이원정;강재은;김유근
    • 한국환경보건학회지
    • /
    • 제39권6호
    • /
    • pp.492-504
    • /
    • 2013
  • Objectives: This analysis seeks to evaluate the impact of environmental health factors (EHF; e.g. hospital beds per capita, employees of medical institutions) on extreme-heat vulnerability assessment in Busan Metropolitan City during 2006-2010. Methods: According to the vulnerability concept suggested by the Intergovernmental Panel on Climate Change (IPCC), extreme-heat vulnerability is comprised of the categories of Exposure, Sensitivity, and Adaptive Capacity (including EHF). The indexes of the Exposure and Sensitivity categories indicate positive effects, while the Adaptive capacity index indicates a negative effect on extreme-heat vulnerability. Variables of each category were standardized by the re-scaling method, and then each regional relative vulnerability was computed with the vulnerability index calculation formula. Results: The extreme-heat vulnerability index (EVI) excepting EHF was much higher in urban areas than in suburban areas within the metropolitan area. When EHF was considered, the difference in the EVI between the two areas was reduced due to the increase of the Adaptive capacity index in urban areas. The low EVI in suburban areas was induced by a dominant effect of natural environmental factors (e.g. green area) within the Adaptive capacity category. Conclusions: To reduce the vulnerability to extreme heat in urban areas, which were more frequently exposed to extreme heat than others areas, public health and natural environments need to be improved in sensitive areas.

Flexural behaviour of square UHPC-filled hollow steel section beams

  • Guler, Soner;Copur, Alperen;Aydogan, Metin
    • Structural Engineering and Mechanics
    • /
    • 제43권2호
    • /
    • pp.225-237
    • /
    • 2012
  • This paper presents an experimental investigation of the flexural behavior of square hollow steel section (HSS) beams subjected to pure bending. Totally six unfilled and nine ultra high performance concrete (UHPC)-filled HSS beams were tested under four-point bending until failure. The effects of the steel tube thickness, the yield strength of the steel tube and the strength of concrete on moment capacity, curvature, and ductility of UHPC-filled HSS beams were examined. The performance indices named relative ductility index (RDI) and strength increasing factor (SIF) were investigated with regard to different height-to-thickness ratio of the specimens. The flexural strengths obtained from the tests were compared with the values predicted by Eurocode 4, AISC-LRFD and CIDECT design codes. The results showed that the increase in the moment capacity and the corresponding curvature is much greater for thinner HSS beams than thicker ones. Eurocode 4 and AISC-LRFD predict the ultimate moment capacity of the all UHPC-filled HSS beams conservatively.

동해안 대게 자망어업의 어획 성능 및 어획 능력 평가 (Assessment of fishing power and fishing capacity of the snow crab (Chionoecetes opilio) gillnet fishery in the East Sea)

  • 이경훈;김병관;김도훈;안희춘;이춘우
    • 수산해양기술연구
    • /
    • 제48권1호
    • /
    • pp.29-39
    • /
    • 2012
  • Currently, environment-friendly and sustainable fisheries are one of the major issues among fisheries authorities. A variety of alternative management policies and projects are going on to enhance fisheries management systems and fishery resources such as a TAC management program and a VDS (Vessel Day Scheme) management scheme for distant water fishing nations in Western and Central Pacific Fisheries Commission (WCPFC) convention area. These kinds of efforts among fisheries management authorities are aimed at limiting fishing capacity or fishing power. In terms of fisheries management, Fishing capacity and fishing power have increased the importance of the impact on a fishery and level of the resources. Increased fishing capacity and fishing power have caused not only depletion of fisheries resource, but also additional fishing cost. therefore, there is a clear need for authorities to manage fishing capacity and fishing power. It is also help ensure the conservation and sustainability of the fishery resources. Because of lack of data, absolute fishing power is difficulty to measure. The notion of relative fishing power is frequently used. In this study, relative fishing power was assessed using Mastuda (1991) method for fishing power index. The raw data for assessment was based on fishermen's logbook data from sampled fishing vessels in coastal snow crab gillnet fishery. Data Envelopment Analysis (DEA) method was used to assess fishing capacity. DEA is a linear programming methodology to measure the efficiency of a set of entities called Decision-Making Units (DMUs). It was recommended by FAO for assessing capacity in fisheries.