• 제목/요약/키워드: Relative Accuracy

검색결과 1,323건 처리시간 0.028초

고체상추출과 GC/MS를 이용한 소변 중 암페타민계 마약성분 동시분석법 (Simultaneous determination of amphetamine-like drugs in human urine by SPE and GC/MS)

  • 정재철;김진영;인문교;정원조
    • 분석과학
    • /
    • 제21권1호
    • /
    • pp.41-47
    • /
    • 2008
  • 소변 중 암페타민계 5성분(amphetamine; AP, methamphetamine; MA, 3,4-methylenedioxyamphetamine; MDA, 3,4-methylenedioxymethamphetamine; MDMA, 3,4-methylenedioxyethylamphetamine; MDEA)의 동시분석을 위하여 기존의 액체상추출(liquid-liquid extraction; LLE) 방법과는 달리 감정과정의 자동화가 가능한 고체상추출(solid-phase extraction, SPE) 방법을 도입하였다. 시험관에 소변 3 mL와 0.1 M 인산완충액 1 mL (pH 7.0)를 넣고, 자동추출장치를 이용하여 추출하고, 증발 건고하여 유도체화 한 다음 GC/MS로 분석하였다. 그 결과 검정곡선의 직선성 상관계수 ($r^2$)는 AP와 MDA [농도범위 34.0 (AP), 28.0 (MDA)~1000.0 ng/mL] 및 MA, MDMA, MDEA (농도범위 50.0~2000.0 ng/mL)에서 0.994 이상으로 나타났다. 그리고 각 성분들의 검출한계 (LOD)는 4.0~10.0 ng/mL 범위였고, 정량한계 (LOQ)는 12.0~34.0 ng/mL 범위였다. 상대 회수율은 5성분 모두 93.5~107.7%로 측정되었다. 정밀도 (precision)와 정확도 (accuracy)는 각각 1.9~14.8%와 -8.7~14.8 % 범위 값을 나타냈다. 본 실험방법을 실제 남용자 소변에 적용한 결과 메스암페타민 또는 엑스터시 투약자를 신속하고 정확하게 동시에 확인할 수 있었다.

엔트로피 개념을 이용한 관수로내의 유속분포에 관한 연구 (A Study on The Velocity Distribution in Closed Conduit by Using The Entropy Concept)

  • 추태호;옥치율;김진원;맹승진
    • 대한토목학회논문집
    • /
    • 제29권4B호
    • /
    • pp.357-363
    • /
    • 2009
  • 일반적으로 사용되는 관수로의 평균유속을 구하려면 Darcy-Weisbach의 마찰손실수두공식을 사용하면 되나, 그러나 이 식의 마찰손실계수 f는 Reynolds수와 상대조도(${\varepsilon}$/d)의 함수이므로 사용하기에 매우 불편하며 따라서 보다 편리한 식이 요구된다. 이에 본 연구에서 Chiu 유속공식의 신뢰성과 정확성을 증명하기 위하여 관수로에서 비삽입식 유속측정 장치인 레이저 유속계(Laser Doppler Velocimeter: LDV) 및 초음파 유량계(Ultrasonic Flowmeter: U/F), 삽입식 유속측정장치인 피토관 (Pitot Tube)을 이용하여 실측한 유속측정 자료와 Chiu의 공식을 이용한 유속분포가 매우 잘 일치함을 증명하였다. 유량의 증감에 관계없이 실험실 수로에서의 최대유속과 평균유속간의 이론적인 선형관계를 증명함으로써 관수로내 유속의 평형상태, 즉 엔트로피 파라미터 M값에 대응하는 평형상태에 도달하려 하고 이 평형상태를 지속적으로 유지하려고 하는 경향이 있음을 증명하였다. 또한, 한 단면을 대표하는 엔트로피 파라미터 M값이 결정되면 최대유속이 발생하는 지점에서의 유속 측정만으로 단면 전체의 평균유속을 쉽게 구할 수 있고 이로부터 간단히 유량을 산정할 수 있음을 증명하였으며, 이는 추후 관수로 설계 및 운영관리 시 가장 중요한 평균유량을 측정할 수 있는 이론적인 도구로 사용될 수 있음을 의미하는 것이다.

Actions to Expand the Use of Geospatial Data and Satellite Imagery for Improved Estimation of Carbon Sinks in the LULUCF Sector

  • Ji-Ae Jung;Yoonrang Cho;Sunmin Lee;Moung-Jin Lee
    • 대한원격탐사학회지
    • /
    • 제40권2호
    • /
    • pp.203-217
    • /
    • 2024
  • The Land Use, Land-Use Change and Forestry (LULUCF) sector of the National Greenhouse Gas Inventory is crucial for obtaining data on carbon sinks, necessitating accurate estimations. This study analyzes cases of countries applying the LULUCF sector at the Tier 3 level to propose enhanced methodologies for carbon sink estimation. In nations like Japan and Western Europe, satellite spatial information such as SPOT, Landsat, and Light Detection and Ranging (LiDAR)is used alongside national statistical data to estimate LULUCF. However, in Korea, the lack of land use change data and the absence of integrated management by category, measurement is predominantly conducted at the Tier 1 level, except for certain forest areas. In this study, Space-borne LiDAR Global Ecosystem Dynamics Investigation (GEDI) was used to calculate forest canopy heights based on Relative Height 100 (RH100) in the cities of Icheon, Gwangju, and Yeoju in Gyeonggi Province, Korea. These canopy heights were compared with the 1:5,000 scale forest maps used for the National Inventory Report in Korea. The GEDI data showed a maximum canopy height of 29.44 meters (m) in Gwangju, contrasting with the forest type maps that reported heights up to 34 m in Gwangju and parts of Icheon, and a minimum of 2 m in Icheon. Additionally, this study utilized Ordinary Least Squares(OLS)regression analysis to compare GEDI RH100 data with forest stand heights at the eup-myeon-dong level using ArcGIS, revealing Standard Deviations (SDs)ranging from -1.4 to 2.5, indicating significant regional variability. Areas where forest stand heights were higher than GEDI measurements showed greater variability, whereas locations with lower tree heights from forest type maps demonstrated lower SDs. The discrepancies between GEDI and actual measurements suggest the potential for improving height estimations through the application of high-resolution remote sensing techniques. To enhance future assessments of forest biomass and carbon storage at the Tier 3 level, high-resolution, reliable data are essential. These findings underscore the urgent need for integrating high-resolution, spatially explicit LiDAR data to enhance the accuracy of carbon sink calculations in Korea.

다중 입력 딥러닝을 이용한 서리 발생 추정 (Estimation of Frost Occurrence using Multi-Input Deep Learning)

  • 김용석;허지나;김응섭;심교문;조세라;강민구
    • 한국농림기상학회지
    • /
    • 제26권1호
    • /
    • pp.53-62
    • /
    • 2024
  • 본 연구에서는 딥러닝을 이용한 모형을 이용해서 우리나라 지역에 대한 서리 발생 예측 모형을 구축하였다. 딥러닝 모형의 학습 데이터로 다양한 기상인자들(최저기온, 풍속, 상대습도, 구름량, 강수량)을 사용하였으며, 기상인자들에 대한 통계적 분석 결과, 서리가 발생한 날과 서리가 발생하지 않은 날에 대해 각 요소별로 유의한 차이가 있는 것을 볼 수 있었다. 단일 딥러닝 모형 3가지와 다중 입력 딥러닝 모형 3가지를 이용하여 서리발생을 추정한 결과, 평균적으로 MLP가 가장 정확도가 낮았으며, LSTM, GRU 순으로 정확도가 높게 나타났고, 다중 입력 딥러닝 모형의 경우 3가지 모형이 거의 비슷한 결과가 나타났지만 그 중 평균적으로 GRU와 MLP를 이용한 모형이 가장 정확도가 높았다. 또한, 단일 딥러닝이 다중 입력 딥러닝에 비해 샘플에 따라 정확도 편차도 더 컸다. 이에 따라 결과적으로 단일 딥러닝 기반의 서리발생 예측 모형보다 다중 입력 딥러닝 기반의 서리발생 예측 모형이 안정성과 정확도와 재현율 측면에서 다소 우수한 것을 확인할 수 있었다.

스테레오 비전 센서 기반 프리팹 강구조물 조립부 형상 품질 평가 (Dimensional Quality Assessment for Assembly Part of Prefabricated Steel Structures Using a Stereo Vision Sensor)

  • 김종혁;전해민
    • 한국전산구조공학회논문집
    • /
    • 제37권3호
    • /
    • pp.173-178
    • /
    • 2024
  • 본 논문에서는 스테레오 비전 센서를 이용한 프리팹 강구조물(PSS: Prefabricated Steel Structures)의 조립부 형상 품질 평가 기법을 소개한다. 스테레오 비전 센서를 통해 모형의 조립부 영상과 포인트 클라우드 데이터를 수집하였으며, 퍼지 기반 엣지 검출, 허프 변환 기반 원형의 볼트 홀 검출 등의 영상처리 알고리즘을 적용하여 조립부 영역의 볼트홀을 검출하였다. 영상 내 추출된 볼트홀 외곽선 위 세 점의 위치 정보에 대응되는 3차원 실세계 위치 정보를 깊이 영상으로부터 획득하였으며, 이를 기반으로 각 볼트홀의 3차원 중심 위치를 계산하였다. 통계적 기법 중 하나인 주성분 분석 알고리즘(PCA: Principal component analysis) 알고리즘을 적용함으로써 3차원 위치 정보를 대표하는 최적의 좌표축을 계산하였다. 이를 통해 센서의 설치 방향 및 위치에 따라 센서와 부재 간 평행이 아니더라도 안정적으로 볼트홀 간의 거리를 계측하도록 하였다. 각 볼트홀의 2차원 위치 정보를 기반으로 볼트홀의 순서를 정렬하였으며, 정렬된 볼트홀의 위치 정보를 바탕으로 인접한 볼트홀 간의 각 축의 거리 정보를 계산하여 조립부 볼트홀 위치 중심의 형상 품질을 분석하였다. 측정된 볼트홀 간의 거리 정보는 실제 도면의 거리 정보와의 절대오차와 상대오차를 계산하여 성능 비교를 진행하였으며, 중앙값 기준 1mm 내의 절대오차와 4% 이내의 상대오차의 계측 성능을 확인하였다.

Coronary Computed Tomography Angiography for the Diagnosis of Vasospastic Angina: Comparison with Invasive Coronary Angiography and Ergonovine Provocation Test

  • Jiesuck Park;Hyung-Kwan Kim;Eun-Ah Park;Jun-Bean Park;Seung-Pyo Lee;Whal Lee;Yong-Jin Kim;Dae-Won Sohn
    • Korean Journal of Radiology
    • /
    • 제20권5호
    • /
    • pp.719-728
    • /
    • 2019
  • Objective: To investigate the diagnostic validity of coronary computed tomography angiography (cCTA) in vasospastic angina (VA) and factors associated with discrepant results between invasive coronary angiography with the ergonovine provocation test (iCAG-EPT) and cCTA. Materials and Methods: Of the 1397 patients diagnosed with VA from 2006 to 2016, 33 patients (75 lesions) with available cCTA data from within 6 months before iCAG-EPT were included. The severity of spasm (% diameter stenosis [%DS]) on iCAGEPT and cCTA was assessed, and the difference in %DS (Δ%DS) was calculated. Δ%DS was compared after classifying the lesions according to pre-cCTA-administered sublingual nitroglycerin (SL-NG) or beta-blockers. The lesions were further categorized with %DS ≥ 50% on iCAG-EPT or cCTA defined as a significant spasm, and the diagnostic performance of cCTA on identifying significant spasm relative to iCAG-EPT was assessed. Results: Compared to lesions without SL-NG treatment, those with SL-NG treatment showed a higher Δ%DS (39.2% vs. 22.1%, p = 0.002). However, there was no difference in Δ%DS with or without beta-blocker treatment (35.1% vs. 32.6%, p = 0.643). The significant difference in Δ%DS associated with SL-NG was more prominent in patients who were aged < 60 years, were male, had body mass index < 25 kg/m2, and had no history of hypertension, diabetes, or dyslipidemia. Based on iCAG-EPT as the reference, the per-lesion-based sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of cCTA for VA diagnosis were 7.5%, 94.0%, 60.0%, 47.1%, and 48.0%, respectively. Conclusion: For patients with clinically suspected VA, confirmation with iCAG-EPT needs to be considered without completely excluding the diagnosis of VA simply based on cCTA results, although further prospective studies are required for confirmation.

Usefulness of Single Voxel Proton MR Spectroscopy in the Evaluation of Hippocampal Sclerosis

  • Kee-Hyun Chang;Hong Dae Kim;Sun-Won Park;In Chan Song;In Kyu Yu;Moon Hee Han;Sang Kun Lee;Chun-Kee Chung;Yang Hee Park
    • Korean Journal of Radiology
    • /
    • 제1권1호
    • /
    • pp.25-32
    • /
    • 2000
  • Objective: The purpose of our study was to determine the ability of H-1 MR spectroscopy (MRS) to lateralize the lesion in patients with hippocampal sclerosis. Materials and Methods: Twenty healthy volunteers and 25 patients with intractable temporal lobe epilepsy whose MR imaging diagnosis was unilateral hippocampal sclerosis were included. This diagnosis was based on the presence of unilateral atrophy and/or high T2 signal intensity of the hippocampus. Single-voxel H-1 MRS was carried out on a 1.5-T unit using PRESS sequence (TE, 136 msec). Spectra were obtained from hippocampal areas bilaterally with volumes of interest (VOIs) of 6.0 cm3 and 2.25 cm3 in healthy volunteers, and of either 6.0 cm3 (n = 14) or 2.25 cm3 (n = 11) in patients. Metabolite ratios of NAA/Cho and NAA/Cr were calculated from relative peak height measurements. The capability of MRS to lateralize the lesion and to detect bilateral abnormalities was compared with MR imaging diagnosis as a standard of reference. Results: In healthy volunteers, NAA/Cho and NAA/Cr ratios were greater than 0.8 and 1.0, respectively. In patients, the mean values of these ratios were significantly lower on the lesion side than on the contralateral side, and lower than those of healthy volunteers (p < .05). The overall correct lateralization rate of MRS was 72% (18/25); this rate was lower with a VOI of 6.0 cm3 than of 2.25 cm3 (64% versus 82%, p < .05). Bilateral abnormalities on MRS were found in 24% (6/25) of cases. Conclusion: Although its rate of correct lateralization is low, single-voxel H-1 MRS is a useful and promising diagnostic tool in the evaluation of hippocampal sclerosis, particularly for the detection of bilateral abnormalities. To improve the diagnostic accuracy of H-1 MRS, further investigation, including the use of a smaller VOI and measurement of the absolute amount of metabolites, are needed.

  • PDF

폐기종 및 간질성 폐질환: 인공지능 소프트웨어 사용 경험 (Using Artificial Intelligence Software for Diagnosing Emphysema and Interstitial Lung Disease)

  • 백상현;진공용
    • 대한영상의학회지
    • /
    • 제85권4호
    • /
    • pp.714-726
    • /
    • 2024
  • 흉부 CT상 폐기종이나 간질성 폐질환의 형태나 범위를 인공지능을 이용하여 자동적으로 객관적으로 진단하는 다양한 알고리즘을 개발되고, 이를 증명하는 연구들이 진행되어 왔다. 흉부 CT상 인공지능을 이용한 폐기종 정량화 연구들을 보면 CT상 폐기종의 상대적인 양이 증가와 폐 기능의 악화와 연관이 있으며, 특히 중심성 폐기종을 중심으로 정량화를 하는 것이 임상 증상이나 만성폐쇄성 폐질환의 사망률을 예측하는 데 도움이 된다고 보고하고 있다. 또한, 간질성 폐질환에서는 인공지능이 CT상 통상성 간질성 폐렴의 형태를 정상, 간유리 음영, 망상형 음영, 벌집 모양, 폐기종, 경화로 분류를 할 수 있고, 인공지능이 흉부영상의학과 전문의와 비슷한 정도로 통상성 간질성 폐렴을 진단(70%-80%) 할 수 있다고 보고했다. 그러나 인공지능의 결과들이 흉부 CT의 스캔 변수들, 재구성 알고리즘, 방사선 선량, 개발된 인공지능 훈련 데이터에 의해 영향을 받으며, 이러한 이유로 아직까지 흉부 CT상 폐기종과 간질성 폐질환의 진단과 정량화는 실제로 일상 업무에서 제한적으로 사용되고 있다. 이 논문에서는 폐기종과 간질성 폐질환의 진단과 정량화를 위해서 인공지능을 사용하고 있는 저자들의 경험을 증례로 소개를 하고, 이 두 질환의 인공지능의 효용성과 제한점에 대해서 언급하고자 한다.

의료서비스 마케팅을 위한 품질지각과 만족에 관한 연구 (A Study on Qulity Perceptions and Satisfaction for Medical Service Marketing)

  • 유동근
    • 간호행정학회지
    • /
    • 제2권1호
    • /
    • pp.97-114
    • /
    • 1996
  • INSTRODUCTION Service quality is, unlike goods quality, an abstract and elusive constuct. Service quality and its requirements are not easily understood by consumers, and also present some critical research problems. However, quality is very important to marketers and consumers in that it has many strategic benefits in contributing to profitability of marketing activities and consumers' problem-solving activities. Moreover, despite the phenomenal growth of medical service sector, few researchers have attempted to define and model medical service quality. Especially, little research has focused on the evaluation of medical service quality and patient satisfaction from the perspectives of both the provider and the patient. As competition intensifies and patients are demanding higher quality of medical service, medical service quality and patient satisfaction has emerged as a critical research topic. The major purpose of this article is to explore the concept of medical service quality and its evaluation from both nurse and patient perspectives. This article attempts to achieve its purpose by (1)classfying critical service attibutes into threecategories(satisfiers, hygiene factors, and performance factors). (2)measuring the relative importance of need criteria, (3)evaluating SERVPERF model and SERVQUAL model in medical service sector, and (4)identifying the relationship between perceived quality and overall patient satisfaction. METHOD Data were gathered from a sample of 217 patients and 179 nurses in Seoul-area general hospitals. From the review of previous literature, 50 survey items representing various facets of the medical service quality were developed to form a questionnaire. A five-point scale ranging from "Strongly Agree"(5) to "Strongly Disagree"(1) accompanied each statement(expectation statements, perception statements, and importance statements). To measure overall satisfaction, a seven-point scale was used, ranging from "Very Satisfied"(7) to "Very Dissatisfied"(1) with no verbal labels for scale points 2 through 6 RESULTS In explaining the relationship between perceived performance and overall satisfaction, only 31 variables out of original 50 survey items were proven to be statistically significant. Hence, a penalty-reward analysis was performed on theses 31 critical attributes to find out 17 satisfiers, 8 hygiene factors, and 4 performance factors in patient perspective. The role(category) of each service quality attribute in relation to patient satisfaction was com pared across two groups, that is, patients and nurses. They were little overlapped, suggesting that two groups had different sets of 'perceived quality' attributes. Principal components factor analyses of the patients' and nurses' responses were performed to identify the underlying dimensions for the set of performance(experience) statements. 28 variables were analyzed by using a varimax rotation after deleting three obscure variables. The number of factors to be extracted was determined by evaluating the eigenvalue scores. Six factors wereextracted, accounting for 57.1% of the total variance. Reliability analysis was performed to refine the factors further. Using coefficient alpha, scores of .84 to .65 were obtained. Individual-item analysis indicated that all statements in each of the factors should remain. On 26 attributes of 31 critical service quality attributes, there were gaps between actual patient's importance of need criteria and nurse perceptions of them. Those critical attributes could be classified into four categories based on the relative importance of need criteria and perceived performance from the perspective of patient. This analysis is useful in developing strategic plans for performance improvement. (1) top priorities(high importance and low performance) (in this study)- more health-related information -accuracy in billing - quality of food - appointments at my convenience - information about tests and treatments - prompt service of business office -adequacy of accommodations(elevators, etc) (2) current strengths(high importance and high performance) (3)unnecessary strengths(low importance and high performance) (4) low priorities(low importance and low performance) While 26 service quality attributes of SERPERF model were significantly related to patient satisfation, only 13 attributes of SERVQUAL model were significantly related. This result suggested that only experience-based norms(SERVPERF model) were more appropriate than expectations to serve as a benchmark against which service experiences were compared(SERVQUAL model). However, it must be noted that the degree of association to overall satisfaction was not consistent. There were some gaps between nurse percetions and patient perception of medical service performance. From the patient's viewpoint, "personal likability", "technical skill/trust", and "cares about me" were most significant positioning factors that contributed patient satisfaction. DISCUSSION This study shows that there are inconsistencies between nurse perceptions and patient perceptions of medical service attributes. Also, for service quality improvement, it is most important for nurses to understand what satisfiers, hygiene factors, and performance factors are through two-way communications. Patient satisfaction should be measured, and problems identified should be resolved for survival in intense competitive market conditions. Hence, patient satisfaction monitoring is now becoming a standard marketing tool for healthcare providers and its role is expected to increase.

  • PDF

자궁경부암용 팬톰을 이용한 HDR (High dose rate) 근접치료의 선량 평가 (Dose Verification Using Pelvic Phantom in High Dose Rate (HDR) Brachytherapy)

  • 장지나;허순녕;김회남;윤세철;최보영;이형구;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제14권1호
    • /
    • pp.15-19
    • /
    • 2003
  • HDR (High dose rate) 근접 치료는 기존의 LDR (Low dose rate) 근접 치료에서 야기되었던 치료 시간이나 선량 최적화 등의 문제점을 해결하였기 때문에 자궁경부암 치료에 많이 사용되고 있다. 그러나, 단시간에 고선량이 조사되는 HDR 근접치료에서 치료 효과를 극대화시키기 위해서는 선량 계산 알고리즘, 위치 계산 알고리즘, 최적화 알고리즘이 정확하게 검증되어야 한다. 이를 위해서는 인체 등가 팬톰과 치료 계획 컴퓨터의 선량 분포 곡선을 비교함으로써 검증할 수 있다. 본 연구에서는 이러한 검증이 가능하도록 자궁경부암용 팬톰을 설계, 제작하여 HDR 치료 계획 컴퓨터와 팬톰과의 선량을 비교, 평가하는 것이다 이 자궁경부암용 팬톰은 높은 해상도를 가진 선량 측정기를 사용하여 정량적인 평가가 가능하도록 제작되었고, 인체 등가물질인 물과 아크릴을 사용하여 제작하였다 또한, 팬톰 내의 방사선량 측정을 위해서 $\frac{1}{8}$ 인치 TLD (Thermoluminescent dosimeters) 칩과 공간 해상도가 1 mm 이내인 필름을 사용하였다. 이 자궁경부암용 팬톰는 HDR applicator의 고정을 위해 applicator 홀더의 홈 안에 HDR applicator가 삽입되게 제작하였고 세 개의 TLD 홀더에는 TLD 칩(TLD 간의 거리는 5 mm)이 정렬되게 제작하여 A점이나 B점 같은 특정 점의 절대 선량을 측정할 수 있게 제작하였다 필름은 3개의 직교(orthogonal) 평면에 삽입되도록 제작하여 상대 선량 측정이 가능하게 하였다. 사용된 치료 계획 시스템은 Nucletron Plato system이고, Microselectron Ir-192 소스를 사용하였다. 선량 평가 결과, TLD 선량의 경우 A, B point를 포함하여 직장과 방광 선량이 $\pm$4% 이내로 치료계획 컴퓨터(Plato, Nucletron)와 일치하였고, 필름의 경우 선량 분포 곡선이 치료계획 컴퓨터의 선량 분포 곡선 패턴과 거의 일치하는 우수한 결과를 보였다. 제작된 자궁경부암용 팬톰은 HDR 치료 계획 컴퓨터의 선량 계산 알고리즘의 평가 및 검증에 유용하게 사용될 것이고, 이 팬톰은 강남성모병원 치료방사선과 HDR 근접치료 기기의 선량과 위치확인의 QA(quality assurance) 도구로써 사용하려고 추진 중에 있다.

  • PDF