• Title/Summary/Keyword: Reinforcing

Search Result 3,014, Processing Time 0.026 seconds

Influence of different fatigue loads and coating thicknesses on service performance of RC beam specimens with epoxy-coated reinforcement

  • Wang, Xiao-Hui;Gao, Yang;Gao, Run-Dong;Wang, Jing;Liu, Xi-La
    • Computers and Concrete
    • /
    • v.19 no.3
    • /
    • pp.243-256
    • /
    • 2017
  • Epoxy-coated reinforcing bars are widely used to protect the corrosion of the reinforcing bars in the RC elements under their in-service environments and external loads. In most field surveys, it was reported that the corrosion resistance of the epoxy-coated reinforcing bars is typically better than the uncoated bars. However, from the experimental tests conducted in the labs, it was reported that, under the same loads, the RC elements with epoxy-coated reinforcing bars had wider cracks than the elements reinforced with the ordinary bars. Although this conclusion may be true considering the bond reduction of the reinforcing bar due to the epoxy coating, the maximum service loads used in the experimental research may be a main reason. To answer these two phenomena, service performance of 15 RC beam specimens with uncoated and epoxy-coated reinforcements under different fatigue loads was experimentally studied. Influences of different coating thicknesses of the reinforcing bars, the fatigue load range and load upper limit as well as fatigue load cycles on the mechanical performance of RC test specimens are discussed. It is concluded that, for the test specimens subjected to the comparatively lower load range and load upper limit, adverse effect on the service performance of test specimens with thicker epoxy-coated reinforcing bars is negligible. With the increments of the coating thickness and the in-service loading level, i.e., fatigue load range, load upper limit and fatigue cycles, the adverse factor resulting from the thicker coating becomes noticeable.

Stress Distribution Characteristics of Surrounding Reinforcing Bars due to Reinforcing Bar Cutting in Penetration (관통부의 철근 절단으로 인한 주변 철근의 응력분포 특성)

  • Chung, Chul-Hun;Moon, Il Hwan;Lee, Jungwhee;Song, Jae Cheol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.6
    • /
    • pp.775-786
    • /
    • 2022
  • In the plant structures including nuclear power plants, penetrations are frequently installed in walls and slabs to reinforce facilities during operation, and reinforcing bars are sometimes cut off during concrete coring. Since these penetrations are not considered at the design or construction stage, cutting of reinforcing bar during opening installation is actually damage to the structure, structural integrity evaluation considering the stress transition range or effective width around the new penetration is necessary. In this study, various nonlinear analyses and static loading experiments are performed to evaluate the effect of reinforcing bar cutting that occurs when a penetration is newly installed in the shear wall of wall-type building of operating nuclear power plant. In addition, the decrease in wall stiffness due to the installed new penetration and cutting of reinforcing bars is evaluated and the stress and strain distributions of rebars around penetration are also measured.

Application and its Reinforcing Effect of Soil Nailed-drilled Shafts (쏘일 네일(soil nail)로 보강된 현장타설말뚝의 적용성 및 보강효과 분석)

  • 김병철;이대수;김대홍;정상섬;김대학
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.5
    • /
    • pp.87-98
    • /
    • 2004
  • In this study reinforcing effect of soil nailed-drilled shafts subjected to axial and lateral loads was evaluated. Special attention was given to the reinforcing effects of soil nails placed from the drilled shafts to surrounding weathered- and soft-rocks based on model tests, numerical analyses and field tests. The model tests and numerical analyses are conducted to analyze the reinforcing effect of various conditions of number, inclination, position and length. The results of 1/40 scale model tests and numerical analyses show that as the number of reinforcing level increases, the incremental effect of reinforcement tends to increase, whereas the reinforcing effect on relative position is negligible. In addition there is a reinforcing effect as the inclination angle increase up to 30 degrees. Based on the results of tensile load tests, soil nailed-drilled shaft has a considerably smaller settlement to reach the ultimate level compared with the result of un-reinforced drilled shafts. For compression tests, there is a reinforcing effect of about 200% measured.

Structural Performance of High Strength Grout-Pilled Splice Sleeve System (고강도 모르타르 충전식 철근이음의 구조성능에 관한 실험연구)

  • 김형기;안병익;남재현;박복만
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.5
    • /
    • pp.516-524
    • /
    • 2001
  • Among many connection methods of reinforcing bar, the grout-filled splice sleeve system is very effective method of precast concrete construction due to its superior construction efficiency, such as large allowable limit to arrangement of reinforcing bars, good application of large sized reinforcing bars. In this study, totally 20 full-sited specimens were made and tested under monotonic and cyclic loading in order to extend the usage range of grout-filled splice sleeve system. The experimental variables adopted in this study are size of reinforcing bars embedded in upper and lower part of sleeve and compressive strength of filled mortar etc. After test was performed, the results were compared and analyzed with respect to previous test of author. Following main conclusions are obtained : 1) The structural performance of splice sleeve system is improved with increasing compressive strength of filled mortar. And also it was verified that the splice sleeve system with over 700 kgf/㎠ mortar compressive strength and over 6.54 development length of reinforcing bar retains the structural performance of over A class(AIJ Criteria). 2) In the case of using different size of reinforcing bars embedded in upper and lower part of sleeve, the result show that splice sleeve matching with large sized reinforcing bar must be used. And also up to 2 level smaller size of reinforcing bar compared to large reinforcing bar embedded in sleeve can be used.

A Study of Quantitative Analysis of Six Basic Reinforcing-reducing Acupunctural Manipulations in Huang di nei jing(黃帝內經) (${\ll}$황제내경${\gg}$ 6가지 기본 보사수법의 정량적 분석연구)

  • Kim, Yu-Jong;Kim, Eun-Jung;Shin, Kyung-Min;Lee, Eun-Sol;Kim, Kyung-Ho;Kim, Kap-Sung;Lee, Seung-Deok
    • Journal of Acupuncture Research
    • /
    • v.29 no.5
    • /
    • pp.151-158
    • /
    • 2012
  • Objectives : We hypothesized that reinforcing-reducing manipulations produce different effects by quantity of stimulation, and examined whether the difference is statistically significant or not. Methods : The study was conducted to the students of College of Oriental Medicine, Dongguk University. We needled into $ST_{36}$ and applied 6 kinds of basic reinforcing-reducing manipulations in Huang di nei jing by randomized sequence. And we had the students to fill up the questionnaire in form of visual analog scale(VAS). We examined whether significant differences in VAS existed between reinforcing-reducing manipulations(by t-test). And we examined whether significant differences in VDRRT(VAS difference between reinforcing-reducing technique) values existed along the gender, body mass index(BMI), age(by t-test), and psychological sensitivity(by ANOVA). Results : 1. The total stimulation quantity from reducing technique was significantly higher than that from reinforcing technique. Individually VAS values of reducing techniques were significantly higher in rotation, slow-rapid, lift-thrust, respiration and open-close manipulation. 2. The highest stimulation quantity was from rotation manipulation. And the highest VDRRT value was from slow-rapid manipulation. 3. When VDRRT values were analyzed by gender, age, BMI, and psychological sensitivity, VDRRT was significantly different by BMI in rotation manipulation, and by psychological sensitivity in rotation, lift-thrust, and slow-rapid manipulation. Conclusions : We could verify that reinforcing-reducing techniques induce different therapeutic effects by different quantities of stimulations. It suggests that reinforcing-reducing techniques could be applied universally, regardless of gender or age. Further studies are needed to consider control group, or patient groups in characteristic conditions.

AN EXPERIMENTAL STUDY ON THE REINFORCING EFFECT 01 MARINE DREDGING CLAY MIXED WITH MICRO-FIBER (Micro-Fiber의 혼합에 의한 해성준설점토의 보강에 관한 실험적 연구)

  • 박영목;허상목
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.11c
    • /
    • pp.143-155
    • /
    • 1999
  • An experimental study has been carried out to investigate the reinforcing effect of marine dredging clay(MDC) mixed with the Micro-Fiber(MF). A series of laboratory tests was performed using specimens of MDC alone and MDC with MF by means of uniaxial and triaxial compression test. In the test programme, three stages of water content of MDC were chosen according to the elapsed time after dredging, and content and length of MF were considered as important factors for reinforcing effect. And the developed strength due to curing was measured both in MDC and composite. The enhancement of strength of composite was found to be increased with the increasing content and length of MF, and curing time, and with decreasing water content of MDC. An additional study has been made for in-situ trafficability on the soft reclaimed ground by MDC due to high water content. It was found that the waste lime was to be applicable for this purpose to get a reinforcing effect of MDC. A further study would lead to the better understanding of the reinforcing mechanism of the composite.

  • PDF

Relations of Whole Grain Consumption with Predisposing, Reinforcing, and Enabling Factors among Korean Adults (일부 한국 성인의 전곡류 섭취빈도와 동기부여, 행동강화, 행동가능 요인간의 연관성)

  • Chae, Da-Hae;Yum, Jin-Hee;Lee, Seung Min
    • Journal of the Korean Dietetic Association
    • /
    • v.20 no.2
    • /
    • pp.133-148
    • /
    • 2014
  • This study compared levels of whole grain consumption-related predisposing, reinforcing, and enabling factors according to socio-demographic variables, and examined how these factors are associated with whole grain consumption frequency among Korean adults. A survey questionnaire was administered to a convenience sample of adult males and females aged 20~59 years (n=300). The questionnaire included questions on predisposing, reinforcing, and enabling factors in relation to whole grain consumption as well as a brief whole grain food frequency questionnaire. Female subjects showed a significantly higher level of negative beliefs on health nutrition taste texture while showing a significantly lower level of social support compared to that of males. The age group of 40~59 years showed a significantly higher social support level than the age group of 20~39 years. Results from multivariate regression analyses showed that different combinations of predisposing, reinforcing, and enabling variables were significant in predicting whole grain consumption frequency according to sex and age. The study findings can be used for developing specific target-oriented nutrition intervention programs for promotion of whole grain intake among Korean adults.

An Experimental Study on the Shear Resistance of Dowel Bars (장부철근의 전단저항에 대한 실험적 연구)

  • 신장호
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.6
    • /
    • pp.216-223
    • /
    • 1995
  • This research is aimed to investigate the influence of the structural parameters on dowel action of reinforcing bars in reinforced concrete members. I~ollowing the previous research, $^{(3.6)}$ a total of forty two specimens were tested to scrutinize the dowel action of reinforcing bars. Concrete cover, reinforcing bar size and bar distance were taken as main test variables for constant compressive strength of concrete. ]+om the test results, the structural behavior of all specimens was almost linear up to failure load. It is seen that dowel force increases as concrete cover increases. Reinforcing bar size and bar distance hardly affects dowel force. It is found that the dowel forces obtained by this experimental research is relatively close to that of regression analysis results and White's equation.

Effect of the Existing Rust on Bond Strength of Concrete and Reinforcement

  • Lee, Byung-Duck;Kim, Kook-Han;Yu, Hwan-Gu;Cheong, Hai-Moon;Ahn, Tae-Song
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.478-481
    • /
    • 2004
  • An experimental investigation on the relationship between corrosion of reinforcement and bond strength in pull-out test specimen has been conducted to establish the allowable limit of rust of reinforcement in the construction field. The reinforcing bars used in this study were rusted before embedded in pull-out test specimen. The first component of this experiment is to make reinforcing bar rust electrically based on Faraday's theory to be 2, 4, 6, 8 and $10\%$ of reinforcing bar weight. For estimation of the amount of rust by weight, Clarke's solution and shot blasting were adopted and compared. Parameters also include 24 and 45MPa of concrete compressive strengths and diameter of reinforcing bar (16, 19 and 25mm). Pull-out tests were carried out according to KS F 2441 and ASTM C 234. Results show that up to $2\%$ of rust increases the bond strength regardless of concrete strength and diameter of reinforcing bar. As expected, the bond strength increases as compressive strength of concrete increases and the diameter of bar decreases.

  • PDF

Numerical Assessment of Reinforcing Details in Beam-Column Joints on Blast Resistance

  • Lim, Kwang-Mo;Shin, Hyun-Oh;Kim, Dong-Joo;Yoon, Young-Soo;Lee, Joo-Ha
    • International Journal of Concrete Structures and Materials
    • /
    • v.10 no.sup3
    • /
    • pp.87-96
    • /
    • 2016
  • This numerical study investigated the effects of different reinforcing details in beam-column joints on the blast resistance of the joints. Due to increasing manmade and/or natural high rate accidents such as impacts and blasts, the resistance of critical civil and military infrastructure or buildings should be sufficiently obtained under those high rate catastrophic loads. The beam-column joint in buildings is one of critical parts influencing on the resistance of those buildings under extreme events such as earthquakes, impacts and blasts. Thus, the details of reinforcements in the joints should be well designed for enhancing the resistance of the joints under the events. Parameters numerically investigated in this study include diagonal, flexural, and shear reinforcing steel bars. The failure mechanism of the joints could be controlled by the level of tensile stress of reinforcing steel bars. Among various reinforcing details in the joints, diagonal reinforcement in the joints was found to be most effective for enhancing the resistance under blast loads. In addition, shear reinforcements also produced favourable effects on the blast resistance of beam-column joints.