• Title/Summary/Keyword: Reinforcing

Search Result 3,030, Processing Time 0.036 seconds

Analytical Study on Splice Performances with the Vertical Noncontact Lapped of Reinforcing Bars (수직으로 비접촉 겹침이음된 철근의 이음성능에 관한 해석적 연구)

  • Lee Ho-Jin;Kim Seung-Hun;Ha Sang-Su;Moon Jeong-Ho;Lee Li-Hyung;Lee Yong-Taeg
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.171-174
    • /
    • 2005
  • In this study, new moment-resisting precast concrete beam-column joint is proposed for moderate seismic regions. It has the connection reinforcing bars, penetrated the joint and lap-spliced with the bottom bars of precast U-beam. To evaluate the performance for noncontact lapped splice, analytical works were conducted. Major variables for FEM analysis are the length of lap, the diameter of connection reinforcing bars, and the distance between lapped bars. The results of this study show thar the these variables has much influence on strength and deformation of lapped joint.

  • PDF

Lap Splice Strength of Reinforcing Bars on the Relitive Rib Area (상대마디면적에 따른 이형철근의 겹침이음 강도)

  • Park, Sung-Gyu;Hong, Geon-Ho;Choi, Dong-Uk
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.307-310
    • /
    • 2005
  • The effects of deformation properties on the bond of steel reinforcing bars to concrete are experimentally studies to expect the lap splice strength. Based on the previous research about relative rib area, lap splice strength between reinforcing bars and concrete can be improved by the control of rib height and spacing. This paper describes the testing and analysis of 15 beam-spliced specimens containing D25, D22, D19 with relative rib areas ranging from 0.066 to 0.162. The tests are analyzed to determine the effect of relative rib area(Rr) on the increase in bond strength. The tests also provide a preliminary indication of the effect of high relative rib area on the splice strength of uncoated bars.

  • PDF

Evaluate Bond Strength of High Relative Rib Area Bars (높은마디면적 철근의 부착 성능평가)

  • Yang Seung Yul;Seo Dong Min;Hong Gun Ho;Choi Oan Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.311-314
    • /
    • 2005
  • Bond between reinforcing bar and surrounding concrete is supposed to transfer load safely in the process of design of reinforced concrete structures. Bond failure of reinforcing bar generally take place by splitting of the concrete cover as bond force between concrete and reinforcing bars exceeds the confinement of the concrete cover and reinforcement. In this study, to evaluate bond strength of high relative rib area bars, beam-end bond and splice beam specimens are tested and the results are discussed. Higher rib height bars when bars are confined showed higher bond strength than lower rib height bars.

  • PDF

Crack Opening Behavior of Concrete Reinforced with High Strength Reinforcing Steel

  • Soltani, Amir;Harries, Kent A.;Shahrooz, Bahram M.
    • International Journal of Concrete Structures and Materials
    • /
    • v.7 no.4
    • /
    • pp.253-264
    • /
    • 2013
  • A major difference between high-strength reinforcing steel and conventional steel in concrete is that the service-load steel stress is expected to be greater. Consequently, the service-load steel strains are greater affecting cracking behavior. A parametric study investigating crack widths and patterns in reinforced concrete prisms is presented in order to establish limits to the service-load steel stress and strain. Additionally, based on the results of available flexural tests, crack widths at service load levels were evaluated and found to be within presently accepted limits for highway bridge structures, and were predictable using current AASHTO provisions. A limitation on service-level stresses of $f_s{\leq}414$ MPa (60 ksi) is nonetheless recommended.

Load-Settlement Characteristics of Drilled Shafts Reinforced by Rockbolts (락볼트로 보강된 심형기초의 하중-침하 분석)

  • 윤경식;이대수;정상섬
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.366-373
    • /
    • 2002
  • This paper describes the load distribution and settlement of rockbolted-drilled shafts subjected to axial and lateral loads with the view to shortening the embedded depth of the pile shaft. The emphasis was on quantifying the reinforcing effects of rockbolts placed from the shafts to surrounding weathered rocks based on small-scale model tests peformed on instrumented piles. The major influencing parameters on reinforcing drilled shaft behavior are the number, the positions on the shaft, the grade, and the inclination angle at which the rockbolts are placed. The model tests was 1/40 scaled simulations of the behavior of the drilled shafts with varying combinations of the major influencing parameters. The incremental effects of reinforcement based on the various parameters have been weighed against load transfer characteristics before and after rockbolt installations.

  • PDF

Reinforcing Effects of Umbrella-type Shell Roofs with Stiffeners (우산형 쉘 지붕의 보강재 보강효과)

  • Son, Byung-Jik;Jung, Dae-Suck;Lee, Kyu-Hwan
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.3 s.81
    • /
    • pp.45-50
    • /
    • 2007
  • In this study, reinforcing effects of umbrella-type shell roofs structures such as stadium, exhibition, auditorium and museum are analyzed. Umbrella-type shell roofs treated in this study are practical shapes of conical shells. The objective of this study is to analyze reinforcing effects of umbrella-type shell roofs with stiffeners. Various locations of stiffeners, that is, edge ring A, B, center ring, junction stringer and center stringer are presented and the effects of reinforcement is examined. Also, the reduction effects of roofs thickness by stiffeners are examined. It is shown that the thickness of roofs can be reduced about $20{\sim}30%$ by junction stringer and more than 60% by edge ring A.

Electric Degraded Properties of EP Cable Rubber (EP 케이블 고무의 전기적 열화 특성)

  • Lee, Sung-Ill;Bae, Duck-Kweon;Kim, Sang-Hyeon;Lee, Jong-Pil;Oh, Yong-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.516-517
    • /
    • 2008
  • The ethylene-propylene (EP) rubbers mixed with one to one ratio is used as an insulation material in the nuclear power plant. It was investigated the effect of the amount of reinforcing agent. moisture absorption and heat treatment on the Ethylene-Propylene(EP) rubbers. The level of degradation was measured by the amount of discharging and. charging currents. When $\gamma$ rays were radiated on the EP rubbers with more charging material, the amount of discharging and charging currents was depended on the amount of reinforcing agent It was verified that the discharging and charging currents irradiated by $\gamma$ rays were higher than those that was not irradiated.

  • PDF

Corrosion Resistance Properties of Rice Husk Ash Blended Concrete

  • Ganesan, K.;Rajagopal, K.;Thangavel, K.
    • Corrosion Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.12-17
    • /
    • 2007
  • Portland cement incorporating supplementary cementing material develops excellent mechanical properties and long term durability characteristics. India is a leading rice producing country and rice husk is considered as waste in the rice milling industries. In this present work, the rice husk ash (RHA) was added to concrete as cement replacement from 0 to 30%. Corrosion performance of reinforcing steel embedded in RHA blended concretes was studied using linear polarization, AC impedance and gravimetric methods. The corrosion rate of steel bars embedded in RHA concretes were compared with control concrete. The results clearly indicate that the corrosion rate of reinforcing steel embedded in concrete is significantly reduced with the incorporation of RHA. A good correlation among gravimetric method and electrochemical methods was observed. Electrochemical impedance study showed 98 percentage reduction in corrosion rate to the RHA blended concrete with 15% replacement than control concrete.

Estimation of Critical Chloride Threshold Value Using Corrosion Monitoring (부식 모니터링을 이용한 콘크리트 내의 임계 염화물량 평가)

  • Bae Su Ho;Lee Kwang Myong;Chung Young Soo;Kim Jee Sang
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.801-804
    • /
    • 2004
  • It should be noted that the critical chloride threshold level is not considered to be a unique value for all conditions. This value is dependent on concrete mixture proportions, cement type and constituents, presence of admixtures, environmental factors, steel reinforcement surface conditions, and other factors. In this study, the accelerated corrosion test for reinforcing steel was conducted by electrochemical and sea water-circulated method, respectively and during the test, corrosion monitoring by half cell potential method was carried out to estimate the critical chloride threshold value when corrosion for reinforcing steel in concrete was perceived. For this purpose, lollypop and beam test specimens were made for $31.4\%,\;41.5\%\;and\;49.7\%$ of w/c. respectively and then the accelerated corrosion test for reinforcing steel was executed. It was observed from the test that the time to initiation of corrosion was found to be different with water-cement ratio and the critical chloride threshold value was found to range from 0.91 to $1.27kg/m^3$.

  • PDF

Behavior Properties of Bridge by Non Destructive and Loading Test (비파괴 및 재하시험에 의한 노후 교량의 거동특성)

  • Min, Jeong-Ki;Kim, Young-Ik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.1
    • /
    • pp.61-71
    • /
    • 2004
  • The performance evaluation and deflection of 3 spans concrete simplicity slab bridge analyzed by non-destructive and loading test. Compressive strength of slab and pier appeared in the range of each 353∼366 kgf/$cm^2$ and 152∼215 kgf/$cm^2$ in rebound number test. Also, it appeared that concrete quality of slab was good after performance improvement. The average compressive strength of slab by core picking appeared 229 kg/$cm^2$. In reinforcing bar arrangement test of span and member, it appeared that horizontal and vertical reinforcing bar was arranged to fixed interval. The value of calculation deflection that carried structural analysis with deflection analysis wave in static loading test appeared higher than that of experimental deflection and it appeared that hardness of this bridge was good. Maximum impact factor that estimated from deflection by running speed in dynamic loading test appeared by 0.216 in 10 km/hr running speed.