• 제목/요약/키워드: Reinforcement concrete

검색결과 2,944건 처리시간 0.028초

FRP Rods로 보강한 콘크리트 보의 전단 내하력의 평가 (Estimation of Shear Carrying Capacity on Concrete Beams, Reinforced with FRP Rods)

  • 최익창;연준희;고재용
    • 한국해양공학회지
    • /
    • 제18권1호
    • /
    • pp.63-68
    • /
    • 2004
  • The purpose of this study is to estimate the contribution of concrete and shear reinforcement, in shear carrying capacity, on concrete beams, reinforced with steel and/or FRP rods. The experimental tests for 12 concrete beams, reinforced with steel and/or FRP rods, are carried out. Experimental parameters includes the mechanical properties of reinforcements in shear and bending, and the ratio of shear reinforcement. This study compares the experimental results of shear carrying capacity in concrete beams, reinforced with steel and/or FRP rods, with the proposed equations. According to the experimental results, the effect of the concrete in concrete beams reinforced with FRP rods is decreased with decreasing Young's modulus of longitudinal tensile reinforcement. This results from the large deflection of concrete beams reinforced with decreasing Young's modulus of longitudinal tensile reinforcement. Also, the contribution of shear reinforcement is smaller than the calculated value, using the truss analogy. This results from the fact that the stress redistribution is not exhibited after the break of shear reinforcement.

Shape determination of 3-D reinforcement corrosion in concrete based on observed temperature on concrete surface

  • Kurahashi, Takahiko;Oshita, Hideki
    • Computers and Concrete
    • /
    • 제7권1호
    • /
    • pp.63-81
    • /
    • 2010
  • We present the shape determination method of 3-D reinforcement corrosion based on observed temperature on concrete surface. The non-destructive testing for reinforcement corrosion in concrete using a heat image on concrete surface have been proposed by Oshita. The position of the reinforcement of corrosion or the cavity can be found using that method. However, the size of those defects can not be precisely measured based on the heat image. We therefore proposed the numerical determination system of the shape for the reinforcement corrosion using the observed temperature on the concrete surface. The adjoint variable method is introduced to formulate the shape determination problem, and the finite element method is employed to simulate the heat transfer problem. Some numerical experiments and the examination for the number of the observation points are shown in this paper.

나선근으로 횡보강된 콘크리트의 응력-변형도 관계 (Stress-Strain Relationships of Concrete Confined by Spiral Reinforcement)

  • 김진근;박찬규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1993년도 봄 학술발표회 논문집
    • /
    • pp.119-123
    • /
    • 1993
  • Axial load-strain relationships of confined concrete with spiral reinforcement were investigated. The main variables were compressive strength of concrete, spacing of hoop reinforcement, and specimen height of plain concrete. The program included tests of eleven confined specimens, and twelve plain specimens, but for all specimens no longitudinal reinforcement was provided. Load-strain curves of confined and plain concrete specimens are reporeted.

  • PDF

철근 콘크리트 시험편의 철근방식에 관한 측정법 (Corrosion Measurements on Reinforcing Rebars in Reinforced Concrete Specimen)

  • 이강균;장지원;한기훈;정영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.281-286
    • /
    • 1997
  • Recent construction activities and maintenance of marine facilities have been accelerating to keep up with rapid economic growth in Korea. Marine concrete structures are exposed to salts an chloride from ocean environments. The corrosion of reinforcement steel caused by chloride-penetration into concrete may severely effect the durability of concrete structures. The objective of this research is to develop a durable concrete by investigating the corrosion resistance of various corrosion protection systems utilizing different water/cement ratio, silica fumes, corrosion inhibitors and etc. A tow-year verification test on various corrosion protection systems has been doing in the laboratory and at the seaside. Corrosion investigations on reinforcement steel are now under progress for more than 180 concrete specimen. Corrosion-related measurements include macrocell corrosion current, instant-off voltage between corroding and noncorroding reinforcement, chloride contents, the corroded surface areas on the reinforcement steel, and etc. A low level of corrosion is investigated on reinforcement steels in concrete specimen made with corrosion inhibitors or applied aqueous impregnating corrosion inhibitors into their surface, even though high chloride contents of concrete specimen.

  • PDF

Load bearing capacity reduction of concrete structures due to reinforcement corrosion

  • Chen, Hua-Peng;Nepal, Jaya
    • Structural Engineering and Mechanics
    • /
    • 제75권4호
    • /
    • pp.455-464
    • /
    • 2020
  • Reinforcement corrosion is one of the major problems in the durability of reinforced concrete structures exposed to aggressive environments. Deterioration caused by reinforcement corrosion reduces the durability and the safety margin of concrete structures, causing excessive costs in managing these structures safely. This paper aims to investigate the effects of reinforcement corrosion on the load bearing capacity deterioration of the corroded reinforced concrete structures. A new analytical method is proposed to predict the crack growth of cover concrete and evaluate the residual strength of concrete structures with corroded reinforcement failing in bond. The structural performance indicators, such as concrete crack growth and flexural strength deterioration rate, are assumed to be a stochastic process for lifetime distribution modelling of structural performance deterioration over time during the life cycle. The Weibull life evolution model is employed for analysing lifetime reliability and estimating remaining useful life of the corroded concrete structures. The results for the worked example show that the proposed approach can provide a reliable method for lifetime performance assessment of the corroded reinforced concrete structures.

콘크리트 구조물의 철근부식으로 인한 균열발생에 관한 실험적, 해석적 결과의 비교 (The comparison between experimental and FEA results for crack initiation due to corrosion of reinforcement)

  • 장상엽;김용철;조용범
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.693-698
    • /
    • 2003
  • Corrosion of reinforcement and deterioration of concrete short the lifetime of reinforced concrete structure and affect the safety of the structure. In particular, the corrosion of reinforcement causing the inner pressure of the interface between the concrete and reinforcement is known to significantly contribute to the premature deterioration of concrete structure. Several attempts have been made to predict the cracking time of the concrete structure. However, problems such as the lack of reproducibility of concrete tests and non-uniformity of materials have hampered thess kinds of studies. Thus, the mechanism of the concrete cracking due to reinforcement corrosion is in the way. This studymeasured the mechanical properties of corrosion products using the nano-indentation test method. Likewise, the critical thickness of corrosion products for the cracking of concrete cover was investigated using the finite element and experimental methods.

  • PDF

고강도 콘크리트를 사용한 RC보의 최대철근비 (Maximum Shear Reinforcement of RC Beams using High Strength Concrete)

  • 이정윤;황현복
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.839-842
    • /
    • 2008
  • 현행 기준식에서는 철근콘크리트 보의 취성적 전단 파괴를 방지하기 위하여 전단보강철근이 항복한 이후에 복부 콘크리트가 압축파괴하도록 최대전단철근비에 대한 제한을 두고 있다. 최대전단철근비에 대한 제한은 각 기준식마다 매우 상이하다. ACI 318-05, CSA-04 와 EC2-02기준에서는 최대전단철근비가 콘크리트의 압축강도에 따라서 변화하지만, 일본기준식은 압축강도와 무관하게 일정한 값이다. 고강도콘크리트가 사용될 경우에 CSA-04와 EC2-02기준에서 요구하는 최대전단철근비는 ACI 318-05의 두 배 이상으로 기준식마다 상이하게 최대전단철근비를 제한하고 있다. 이 연구에서는 10개의 철근콘크리트 보 실험을 통하여 최대철근비가 미치는 보의 거동 및 내력을 평가하였다. 실험 결과에 의하면 ACI 318-05에서 요구하는 철근비보다 많은 전단보강철근이 배근된 보에서도 전단보강철근이 항복한 이후에 콘크리트가 압축파괴하였다.

  • PDF

콘크리트 건조수축 균열제어를 위한 합리적인 최소철근량 (Reasonable Minimum Reinforcement for Crack Control of Concrete Shrinkage)

  • 김수만;오민호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.441-444
    • /
    • 1999
  • The crack width of concrete structures subjected to shrinkage depend on a great number of parameters whose effects are restrain condition, the number and spacing of crack and the amounts of reinforcements. Through suitable reinforcement it is possible to make the individual cracks exceedigly small. This paper is to present the amount of reasonable reinforcement for crack control through a rational analysis of forces occuring in significantly restrained concrete structures due to the shrinkage. Also the analysis results from this paper are compared with the provisions for shrinkage and temperture reinforcement in the KCI concrete strucural design code.

  • PDF

Symptom-based reliability analyses and performance assessment of corroded reinforced concrete structures

  • Chen, Hua-Peng;Xiao, Nan
    • Structural Engineering and Mechanics
    • /
    • 제53권6호
    • /
    • pp.1183-1200
    • /
    • 2015
  • Reinforcement corrosion can cause serious safety deterioration to aging concrete structures exposed in aggressive environments. This paper presents an approach for reliability analyses of deteriorating reinforced concrete structures affected by reinforcement corrosion on the basis of the representative symptoms identified during the deterioration process. The concrete cracking growth and rebar bond strength evolution due to reinforcement corrosion are chosen as key symptoms for the performance deterioration of concrete structures. The crack width at concrete cover surface largely depends on the corrosion penetration of rebar due to the expansive rust layer at the bond interface generated by reinforcement corrosion. The bond strength of rebar in the concrete correlates well with concrete crack width and decays steadily with crack width growth. The estimates of cracking development and bond strength deterioration are examined by experimental data available from various sources, and then matched with symptom-based lifetime Weibull model. The symptom reliability and remaining useful life are predicted from the predictive lifetime Weibull model for deteriorating concrete structures. Finally, a numerical example is provided to demonstrate the applicability of the proposed approach for forecasting the performance of concrete structures subject to reinforcement corrosion. The results show that the corrosion rate has significant impact on the reliability associated with serviceability and load bearing capacity of reinforced concrete structures during their service life.

Numerical simulation of concrete confined by transverse reinforcement

  • Song, Zhenhuan;Lu, Yong
    • Computers and Concrete
    • /
    • 제8권1호
    • /
    • pp.23-41
    • /
    • 2011
  • The behaviour of concrete confined by transverse reinforcement is a classical topic. Numerous studies have been conducted to establish the stress-strain relationships for concrete under various confining reinforcement arrangements. Many empirical and semi-empirical formulas exist. Simplified analytical models have also been proposed to evaluate the increase in the strength and ductility of confined concrete. However, relatively few studies have been conducted to utilise advanced computational models for a realistic simulation of the behaviour of concrete confined by transverse reinforcement. As a matter of fact, high fidelity simulations using the latest numerical solvers in conjunction with advanced material constitutive models can be a powerful means to investigating the mechanisms underlying the confining effects of different reinforcement schemes. This paper presents a study on the use of high fidelity finite element models for the investigation of the behaviour of concrete confined by stirrups, as well as the interpretation of the numerical results. The development of the models is described in detail, and the essential modelling considerations are discussed. The models are then validated by simulating representative experimental studies on short columns with different confining reinforcement schemes. The development and distribution of the confining stress and the subsequent increase in the axial strength are examined. The models are shown to be capable of reproducing the behaviour of the confined concrete realistically, paving a way for systematic parametric studies and investigation into complicated confinement, load combination, and dynamic loading situations.