• Title/Summary/Keyword: Reinforcement Detail

Search Result 159, Processing Time 0.04 seconds

A Study on the Damage Reinforcement of Gallery Pipes Under the Ground Subjected to Various Railway loads (다양한 철도하중을 받는 지중 갤러리관의 손상 보강에 관한 연구)

  • Lee Won-Gyu;Lee Sang-Bum;Kim Rae-Chul;Kim Mu-Il
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1144-1149
    • /
    • 2004
  • This study deals with the damage reinforcement of structures under the ground such as gallery pipes subjected to railway loads. Railway loads with various moving velocities make significant influences on the ground gallery pipes passing through under the railway. For real structures this study analyzes such effects in detail and establishes a method for the efficient damage reinforcement Moreover we predict the hereafter structural behaviors of gallery pipes under the ground by several numerical simulation. The results of this study are expected to offer useful guidelines for explaining the complicated damage characteristics of the ground gallery pipe structures.

  • PDF

Hysteric Behavior of Ultra-High Strength RC Columns (초고강도 RC 기둥의 이력특성에 관한 실험적 연구)

  • Kim Jong Keun;Ahn Jong Mun;Han Beom Seok;Shin Sung Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.31-34
    • /
    • 2005
  • An experimental investigation was conducted to examine the hysteric behavior of Ultra-High strength concrete columns for the requirement of ACI provision. Seven 1/3 scaled columns were fabricated to simulate an 1/2 story of actual structural members with the cross section $300\times300mm$ and the shear span ratio 4. The main variables are axial load ratio, configuration and volumetric ratio of transverse reinforcement. It has been found that the behavior of columns was affected by axial load ratio rather than the amount and the configuration of transverse reinforcement. Consequently, to secure the ductile behavior of 100MPa Ultra-High strength concrete columns, ACI provision for the requirement of transverse steel may considered axial level and the detail of transverse reinforcement.

  • PDF

Cyclic Behavior of High-Performance Fiber-Reinforced Cement Composite Coupling Beam Having Diagonal Reinforcement (대각철근을 갖는 고성능 섬유보강 시멘트 복합체 연결보의 이력거동 평가)

  • Kwon, Hyun-Wook;Jeon, Yong-Ryul;Lee, Ki-Hak;Shin, Myung-Su;Han, Sang-Whan
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.6
    • /
    • pp.649-656
    • /
    • 2013
  • Coupled shear walls can provide an efficient structural system to resist lateral force. However, the reinforcement detail for diagonally reinforced coupling beams required by ACI-318 often causes the difficulties in construction due to the reinforcement congestion and interference among reinforcement. This paper is to evaluate cyclic behavior of High-Performance Fiber-Reinforced Cement Composite (HPFRCC) coupling beams having reduced transverse reinforcement around the beam perimeter. Experimental test was conducted using three specimens having a beam aspect ratio 2.0. Test results showed that HPFRCC coupling beams with half of transverse reinforcement required by ACI-318 provided similar energy dissipation capacities compared with the coupling beams having reinforcement satisfy the requirement of ACI-318.

A fast and robust procedure for optimal detail design of continuous RC beams

  • Bolideh, Ameneh;Arab, Hamed Ghohani;Ghasemi, Mohammad Reza
    • Computers and Concrete
    • /
    • v.24 no.4
    • /
    • pp.313-327
    • /
    • 2019
  • The purpose of the present study is to present a new approach to designing and selecting the details of multidimensional continuous RC beam by applying all strength, serviceability, ductility and other constraints based on ACI318-14 using Teaching Learning Based Optimization (TLBO) algorithm. The optimum reinforcement detailing of longitudinal bars is done in two steps. in the first stage, only the dimensions of the beam in each span are considered as the variables of the optimization algorithm. in the second stage, the optimal design of the longitudinal bars of the beam is made according to the first step inputs. In the optimum shear reinforcement, using gradient-based methods, the most optimal possible mode is selected based on the existing assumptions. The objective function in this study is a cost function that includes the cost of concrete, formwork and reinforcing steel bars. The steel used in the objective function is the sum of longitudinal and shear bars. The use of a catalog list consisting of all existing patterns of longitudinal bars based on the minimum rules of the regulation in the second stage, leads to a sharp reduction in the volume of calculations and the achievement of the best solution. Three example with varying degrees of complexity, have been selected in order to investigate the optimal design of the longitudinal and shear reinforcement of continuous beam.

A Study on the Effect of Steel Fiber in Reinforced Concrete Coupling Beam Subjected to Cyclic Loading (반복하중을 받는 철근콘크리트 연결보에서 강섬유의 보강효과에 관한 연구)

  • Kim, Jin-Sung;Bae, Baek-Il;Choi, Chang-Sik
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.10
    • /
    • pp.181-190
    • /
    • 2019
  • In this study, four reinforced concrete coupling beams were subjected to cyclic lateral loading test to evaluate the structural performance of coupling beam according to volume fraction of steel fiber. For this purpose, the volume fraction of steel fiber(0%, 1%, 2%) and transverse reinforcement spacing were determined as the main parameter. According to the test results, the maximum strength of D-40C-s100-0 was 1.15, 1.13, 1.05 times higher than D-40C-s300-0, D-40C-s300-1, D-40C-s300-2, respectively. The maximum strength of coupling beams with mitigated rebar details increases as the volume fraction of steel fiber increases. Although steel fiber 2% reinforced specimen(D-40C-s300-2) did not satisfy the amount of transverse reinforcement required for seismic design of coupling beam, the overall performance including to maximum strength, ductility and energy dissipation capacity was similar to the control specimen(D-40C-s100-0). As a result, the use of steel fiber with 2% reinforcement can partially replace the transverse reinforcement in diagonally reinforced concrete coupling beam.

Seismic Evaluation of RC Special Shear Wall with Improved Reinforcement Details in Boundary Elements (경계요소의 횡보강근 상세를 개선한 RC 특수전단벽의 내진성능 평가)

  • Chun, Young-Soo
    • Land and Housing Review
    • /
    • v.3 no.2
    • /
    • pp.195-202
    • /
    • 2012
  • This paper summarizes the seismic performance of two shear walls with different reinforcement details in boundary elements. One is a special shear wall designed by KBC2009 and the other is a shear wall with improved reinforcement details in boundary elements, which is a newly proposed type of special shear wall. Experimental tests under cyclic reversed loading were carried out with two 2/3 scale shear walls which were modelled from the lower part of seismic-resisting shear wall in 22-stories wall-slab apartment building. The experimental results show that seismic performance of shear wall with improved reinforcement details was almost similar to that of special shear wall with respect to the moment-drift ratio. However, energy dissipation capacity and ductility were slightly different. Also, shear wall with improved reinforcement details in boundary elements satisfied the inter-story drift limit of 1.5% from KBC2009.

Shear Behavior Characteristics of Joint according to Strain-Hardening Cement Composite Types (시멘트 복합체 종류에 따른 접합부의 전단거동특성)

  • Nam, Sang-Hyun;Jeon, Esther;Yun, Hyun-Do;Choi, Ki-Sun;You, Young-Chan;Kim, Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.27-28
    • /
    • 2010
  • This paper discusses behavior of Joint with strain hardening cement composites(SHCC). The main variables considered include the type of cement composites(mortar, SHCC with hybrid fiber) and shape and space of reinforcement. As the result of the tests, for the same reinforcement detail, SHCC specimen showed better overall behavior(stress, ductile, multiple cracking) than mortar specimen.

  • PDF

Life cycle reliability analyses of deteriorated RC Bridge under corrosion effects

  • Mehmet Fatih Yilmaz
    • Earthquakes and Structures
    • /
    • v.25 no.1
    • /
    • pp.69-78
    • /
    • 2023
  • Life-cycle performance analysis of a reinforced concrete box section bridge was generated. Moreover, Monte Carlo simulation with important sampling (IS) was used to simulate the bridge material and load uncertainties. The bridge deterioration model was generated with the basic probabilistic principles and updated according to the measurement data. A genetic algorithm (GA) with the response surface model (RSM) was used to determine the deterioration rate. The importance of health monitoring systems to sustain the bridge to give services economically and reliably and the advantages of fiber-optic sensors for SHM applications were discussed in detail. This study showed that the most effective loss of strength in reinforced concrete box section bridges is corrosion of the reinforcements. Due to reinforcement corrosion, the use of the bridge, which was examined, could not meet the desired strength performance in 25 years, and the need for reinforcement. In addition, it has been determined that long-term health monitoring systems are an essential approach for bridges to provide safe and economical service. Moreover the use of fiber optic sensors has many advantages because of the ability of the sensors to be resistant to environmental conditions and to make sensitive measurements.

Constructability and Economic Evaluation of Continuous Hoop Reinforcement Method

  • Kang, Su-Min;Park, Sung-Woo;Jang, Se-Woong;Jin, Jong-Min;Eom, Tae-Sung;Park, Hong-Gun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.3
    • /
    • pp.291-305
    • /
    • 2013
  • This paper presents the continuous hoop reinforcement method as a means to overcome the difficulty of rebar construction due to the seismic detail of lateral reinforcement. Because the continuous hoop has no seismic hook, and there is less interference during the rebar work, rebar quantities and construction time can be reduced. Since the details of column and beam continuous hoops are different from those of conventional lateral reinforcements, the construction method should be developed through mock-up tests. The length of the beam mock-up is 8m and the section size is $500mm{\times}700mm$, the height of the column mock-up is 2.8m and 4m, and the section size is $800{\times}800mm$. The length and the size are determined based on the elements that are generally used in reinforced concrete basement parking lots and office buildings. The results of the mock-up test showed that the quantities of rebar could be reduced by 20% and the time could be reduced by up to 40% compared with conventional lateral reinforcements.

Response of a steel column-footing connection subjected to vehicle impact

  • Kang, Hyungoo;Kim, Jinkoo
    • Structural Engineering and Mechanics
    • /
    • v.63 no.1
    • /
    • pp.125-136
    • /
    • 2017
  • This study investigated the performance of a steel column standing on a reinforced concrete footing when it was subjected to collision of an eight-ton single unit truck. Finite element analyses of the structure with different connection schemes were performed using the finite element model of the truck, and the results showed that the behavior of the column subjected to the automobile impact depended largely on the column-footing connection detail. Various reinforcement schemes were investigated to mitigate the damage caused by the car impact. The probability of the model reinforced with a certain scheme to reach a given limit state was obtained by fragility analysis, and the effects of the combined reinforcement methods were investigated based on the equivalent fragility scheme. The analysis results showed that the reinforcement schemes such as increase of the pedestal area, decrease of the pedestal height, and the steel plate jacketing of the pedestal were effective in reducing the damage. As the speed of the automobile increased the contribution of the increase in the number of the anchor bolts and the dowel bars became more important to prevent crushing of the pedestal.