• Title/Summary/Keyword: Rehabilitation Training Device

Search Result 77, Processing Time 0.023 seconds

Study on the Smart 1RM System Development and Effect Verification for Health Improvement and Management of National Healthcare (국민 건강관리 및 체력증진을 위한 스마트 1RM 시스템 개발 및 효과 검증에 관한 연구)

  • Woo, Kyung-Min;Shin, Mi-Yeon;Yu, Chang-Ho
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.12 no.1
    • /
    • pp.53-62
    • /
    • 2018
  • In this study, we developed a smart 1RM system for national health management and physical fitness, which enables quantitative 1RM measurement in various types of exercise using digital pulley technology, and to test the effect on training by using it. We developed the smart 1RM system, which is composed of portable muscle strength measuring device, Bluetooth communication based mobile phone data transmission and circuit diagram, and height adjustable system body. We recruited the 30 participants with 20th aged and divided into training and non-performing groups with 15 participants randomly. The participants performed 5 sets of elbow, lumbar, knee extension / flexion 10 times using smart 1RM system and the experimental period was 3 days a week for a total of 8 weeks. The experimental results showed that the maximum strength of the elbow, lumbar, and knee joints was significantly improved before and after maximal muscle strength training in the training group. Oxygen intakes during 1RM exercise mode showed 10.91% than endurance. To verify the validity of the smart 1RM maximal strength data, the reliability was 0.895 (* p <0.00). This study can be applied to the early rehabilitation treatment of the elderly and rehabilitation patients more quantitatively using the national health care.

Introduction to Knobology Focusing on B Mode and Doppler Setting in Musculoskeletal Ultrasound (근골격계 초음파의 기판 조절 입문: B Mode와 Doppler)

  • Min, Kyunghoon
    • Clinical Pain
    • /
    • v.20 no.1
    • /
    • pp.7-14
    • /
    • 2021
  • Musculoskeletal ultrasound has evolved as the essential tool to diagnose and guide intervention procedures in people with neuromusculoskeletal conditions. Image optimization and understanding device operations are core components for ultrasound guided intervention procedure training. All ultrasound machines share the common operative features and there are various buttons for the features in the device control panel. Ultrasound "knobology" refers to the thorough understanding of imaging optimization. This review addressed basic information for the transducers, depth setting, gain and focus control, different modes focusing on brightness and doppler modes.

Comparison of the Effects of Different Adduction Loads on EMG Activities of Selected Shoulder Muscles During Shoulder External Rotation Exercise in Healthy Young People

  • Peng, Cheng;Bae, Chang-Hwan;Choi, Eun-Hong;Kim, Myoung-Kwon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.14 no.2
    • /
    • pp.1-7
    • /
    • 2019
  • PURPOSE: This study was conducted to investigate effects of shoulder adduction load on rotator cuff muscles, including the infraspinatus, during the external rotation exercise of shoulder. METHODS: This study investigated 16 healthy university students from Daegu University. Before the study started, all participants understood the content of this study. They signed an informed consent form. Five electrodes for surface electromyography (sEMG) were attached to their infraspinatus, middle deltoid, posterior deltoid, upper trapezius and pectoralis major. The participants then underwent the shoulder external rotation exercise with the shoulder adduction at three loads (0 mmHg, 20 mmHg and 40 mmHg) that were controlled using a stabilizer Pressure $Bio-feedback^{TM}$ device. The surface electrodes recorded the electromyographic data during the external rotation exercise of shoulder. RESULTS: The infraspinatus was most activated when the shoulder adduction pressure was 40 mmHg during the external rotation exercise of shoulder. The infraspinatus activation significantly increased when the shoulder adduction pressure intensity increased, while the middle deltoid activation and the posterior deltoid activation significantly decreased (p<.05). CONCLUSION: In conclusion, increases in shoulder adduction load intensity during shoulder external rotation exercises can have a positive effect on the infraspinatus, which consists of rotator cuff muscles, with minimal activity in the middle and posterior deltoid.

Analysis of Movement Time and Trunk Motions According to Target Distances and Use of Sound and Affected Side During Upper Limb Reaching Task in Patients With Hemiplegia (편마비 환자의 팔 뻗기 과제 수행 시 목표거리와 건·환측 사용에 따른 운동시간과 체간의 움직임 분석)

  • Kim, Ki-Song;Yoo, Hwan-Suk;Jung, Doh-Heon;Jeon, Hye-Seon
    • Physical Therapy Korea
    • /
    • v.17 no.1
    • /
    • pp.36-42
    • /
    • 2010
  • The aim of this study was to investigate effects of reaching distance on movement time and trunk kinematics in hemiplegic patients. Eight hemiplegic patients participated in this study. The independent variables were side (sound side vs. affected side) and target distance (70%, 90%, 110%, and 130% of upper limb). The dependent variables were movement time measured by pressure switch and trunk kinematics measured by motion analysis device. Two-way analysis of variance with repeated measures was used with Bonferroni post-hoc test. (1) There were significant main effects in side and reaching distance for movement time (p=.01, p=.02). Post-hoc test revealed that there was a significant difference between 110% and 130% of reaching distance (p=.01). (2) There was a significant main effect in side and reaching distance for trunk flexion (p=.01, p=.00). Post-hoc test revealed that there were significant differences in all pair-wise reaching distance comparison. (3) There was a significant side by target distance interaction for trunk rotation (p=.04). There was a significant main effect in target distance (p=.00). Post-hoc test revealed that there were significant differences between 70% and 110%, 70% and 130%, 90% and 110%, 90% and 130% of target distance. It was known that trunk flexion is used more than trunk rotation during reaching task in hemiplegic patients from the findings of this study. It is also recommended that reaching training is performed with limiting trunk movement within 90% of target distance whereas reaching training is performed incorporating with trunk movement beyond 90% of target distance in patients with hemiplegia.

The immediate effectiveness of mobile game-based instruction with an extracorporeal biofeedback device for an exercise program to improve pelvic floor muscle contraction in healthy subjects

  • Kang, Hyo Jeong;Kim, Mi-Hwa;Hwang, Ji Hye;Lee, Wan-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.9 no.3
    • /
    • pp.209-214
    • /
    • 2020
  • Objective: Using biofeedback in instructing pelvic floor muscle (PFM) activation is a great method to provide information on muscle contraction. This study aimed to determine the immediate effectiveness of a mobile game-based instruction with an extracorporeal biofeedback device (EBD) to improve PFM contraction in healthy subjects. Design: Cross-sectional study. Methods: Sixteen healthy subjects (4 men and 12 nulliparous women; age, 31±5 years) were enrolled. The subjects were randomly categorized into two groups, those who were to receive instructions on how to contract the PFM by using the EBD (n=7) and those who were to undergo a transabdominal ultrasonography (TAUS; n=9) with biofeedback. PFM function was measured as the displacement (mm) of PFM elevation by using the TAUS before and after the instructions in each group. Results: The EBD and TAUS groups showed a significant increase in the displacement of PFM elevation after the instructions from 5.93±4.03 mm to 7.62±3.77 mm and from 5.27±3.39 mm to 7.47±2.79 mm, respectively (p<0.05). No significant differences were found between the two groups. Conclusions: The results of this study indicated that instructions for PFM contraction using the EBD and TAUS showed an immediate effect; however, no significant difference in effectiveness was observed between the two instruction methods. Therefore, not only can the TAUS method be used but the EBD method can also be used as a PFM instruction method for noninvasive procedures. However, further studies are needed to demonstrate the effectiveness of training and exercise on larger sample sizes that includes patient populations with PFM dysfunction.

Uncontrolled Manifold Analysis of Whole Body CoM of the Elderly: The Effect of Training using the Core Exercise Equipment

  • Park, Da Won;Koh, Kyung;Park, Yang Sun;Shim, Jae Kun
    • Korean Journal of Applied Biomechanics
    • /
    • v.28 no.4
    • /
    • pp.213-218
    • /
    • 2018
  • Objective: The purpose of this study was to examine the effect of the core muscle strength enhancement of the elderly on 8 weeks training using the core exercise equipment for the elderly on the ability to control the whole-body center of mass in posture stabilization. Method: 16 females (10 exercise group, 6 control group) participated in this study. Exercise group took part in the core strength training program for 8 weeks with total of 16 repetitions (2 repetitions per week) using a training device. External perturbation during standing as pulling force applied at the pelvic level in the anterior direction was provided to the subject. In a UCM model, the controller selects within the space of elemental variables a subspace (a manifold, UCM) corresponding to a value of a performance variable that needs to be stabilized. In the present study, we were interested in how movements of the individual segment center of mass (elemental variables) affect the whole-body center of mass (the performance variable) during balance control. Results: At the variance of task-irrelevant space, there was significant $test^*$ group interactions ($F_{1,16}=7.482$, p<.05). However, there were no significant main effect of the test ($F_{1,16}=.899$, p>.05) and group ($F_{1,16}=1.039$, p>.05). At the variance of task-relevant space, there was significant $test^*$ group interactions ($F_{1,16}=7.382$, p<.05). However, there were no significant main effect of the test ($F_{1,16}=.754$, p>.05) and group ($F_{1,16}=1.106$, p>.05). Conclusion: The results of this study showed that the 8 weeks training through the core training equipment for the elderly showed a significant decrease in the $Vcm_{TIR}$ and $Vcm_{TR}$. This result indicates that the core strength training affects the trunk stiffness control strategy to maintain balance in the standing position by minimizing total variability of individual segment CMs.

Development of Smart Driving System Using iPod and Its Performance Evaluation for People with Severe Physical Disabilities in the Driving Simulator

  • Jung, Woo-Chul;Kim, Yong-Chul
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.5
    • /
    • pp.637-646
    • /
    • 2012
  • Objective: The aim of this study was to develop the adaptive device for severe physical disabilities using smart device in the driving simulator and its performance evaluation. Development of appropriate driving adaptive device for the people with serious physical limitation could contribute to maintain their community mobility. Background: There is lack of adaptive driving devices for the people with disabilities in Korea. However, if smart device systems like iPod and iPhone are used for driving a car, the people with serious physical limitations can improve their community mobility. Method: Both gyroscope and accelerometer from iPod were used to measure the tilted angle of the smart device for driving. Customized Labview program was also used to control three axis motors for steering wheel, accelerator and brake pedals. Thirteen subjects were involved in the experiment for performance evaluation of smart device in simulator. Five subjects had driver licenses. Another four subjects did not have driver licenses. Others were people with disabilities. Results: Average driving score of the normal group with driver license in the simulator increased 46.6% compared with the normal group without driver license and increased 30.4% compared with the disabled group(p<0.01). There was no significant difference in the average driving score between normal group without driver license and disabled group(p>0.05). Conclusion: The normal group with driver license showed significantly higher driving score than other groups. The normal group without driver license and disabled group could improve their driving skills with training in simulator. Application: If follow-up studies would be continued and applied in adapted vehicle for on road environment, many people with more severe disabilities could drive and improve the quality of life.

Development of Finger-force Measuring System with Six-axis Force/moment Sensor for Measuring a Spherical-object Grasping Force (6 축 힘/모멘트센서를 이용한 구물체 잡기 손가락 힘측정장치 개발)

  • Kim, Hyeon-Min;Yoon, Joung-Won;Shin, Hee-Suk;Kim, Gab-Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.11
    • /
    • pp.37-45
    • /
    • 2010
  • Stroke patients can't use their hands because of the paralysis of their fingers. Their fingers are recovered by rehabilitating training, and the rehabilitating extent can be judged by grasping a spherical object. At present, the used object in hospital is only a spherical object, and can't measure the force of fingers. Therefore, doctors judge the rehabilitating extent by touching and watching at their fingers. So, the spherical object measuring system which can measure the force of their fingers should be developed. In this paper, the finger-force measuring system with a six-axis force/moment sensor which can measure the spherical-object grasping force is developed. The six-axis force/moment sensor was designed and fabricated, and the force measuring device was designed and manufactured using DSP (digital signal processing). Also, the grasping force test of men was performed using the developed finger-force measuring system, it was confirmed that the average force of men was about 120N.

A Comparative Analysis on the AAC Service Delivery System between the U.S. and Korea (미국과 한국의 AAC 서비스 전달체계 비교 분석)

  • Rhee, Kun Min;Yim, Sung-bin;Na, Da Yung
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.2
    • /
    • pp.99-105
    • /
    • 2017
  • The purpose of this study was to compare AAC service delivery system between Korea and U.S.A for appling effective 'AAC service delivery system. This delivery system complement the missing part in system of the current method and narrow blind area for system. The result of this research, increase suppling item of assistive communication device in public benefit and provide delivery system through construct infrastructure by assistive technology center, special education support center, developmental disorder support center, speech therapy center in each local area. Furthermore, assistive technology-related institute and academy develope training programs for human resources to delivery AAC service.

Inspiratory Muscle Strengthening Training Method to Improve Respiratory Function : Comparison of the Effects of Diaphragmatic Breathing with Upper Arm Exercise and Power-Breathe Breathing (호흡 기능 향상을 위한 들숨근 강화 훈련 방법 : 위팔운동을 동반한 가로막 호흡과 파워브리드 호흡의 효과 비교)

  • Lee, Keon-Cheol;Choo, Yeon-Ki
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.9 no.3
    • /
    • pp.203-211
    • /
    • 2021
  • Purpose : It was to compare changes in respiratory function (pulmonary function, inspiratory function) after four weeks of inspiratory muscle strengthening training (diaphragmatic breathing with upper arm exercise, Power-Breathe breathing) for 36 healthy people. Methods : Subjects were randomly assigned to diaphragmatic breathing with upper arm exercise (Group I) and Power-breathe breathing (Group II) was conducted by the protocol for four weeks five times per week. As the main measurement method for comparison between groups For pulmonary function, Forced Vital Capacity (FVC) and Forced Expiratory Volume at One second (FEV1) were used, and for inspiratory function, Maximum Inspiratory Capacity (MIC), Maximum Inspiratory Pressure (MIP), and Maximum Inspiratory Flow Rate (MIFR) were used. Results : In changes in pulmonary function between groups, FVC and FEV1 showed no significant difference, and in inspiratory function changes, MIC showed no significant difference, but in MIP and MIFR, Group B significantly improved over Group A. Conclusion : The progressive resistance training using the Power-breath device applied to the inspiratory muscle did not show a significant difference in the increase in the amount of air in the lungs and chest cage compared to the diaphragmatic breathing training accompanied by the upper arm exercise. However, by increasing the air inflow rate and pressure, it showed a more excellent effect on improving respiratory function.