• Title/Summary/Keyword: Rehabilitation System

Search Result 2,008, Processing Time 0.034 seconds

Judgment Method of the Rehabilitation Extent using a Spherical Type Digital Finger Force Measuring System (구형 디지털 손가락 힘측정장치를 이용한 재활정도 판단 방법)

  • Kim, Hyeon-Min;Kim, Gab-Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.8
    • /
    • pp.729-735
    • /
    • 2014
  • This paper presents the judgment method of the rehabilitation extent using a spherical type digital finger force measuring system (SDFFMS). Stroke patients can't use their fingers because of the paralysis of their fingers, but they can recover with rehabilitative training. The SDFFMS has been already developed by Kim (Author of this paper), and the finger grasping forces of normal people and stroke patients could be measured using it. But the SDFFMS could be not used to judge the extent of their rehabilitation, because the judgment method using it is not yet developed. In this paper, the characteristics tests for the grasping forces of normal persons and stroke patients were performed using the SDFFMS, and the judgment method of the rehabilitation extent was developed using the results. The tests confirm that the rehabilitation extent of stroke patients could be judged using the developed judgment method.

A Remote Rehabilitation System using Kinect Stereo Camera (키넥트 스테레오 영상을 이용한 원격 재활 시스템)

  • Kim, Kyungah;Chung, Wan-Young;Kim, Jong-Jin
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.3
    • /
    • pp.196-201
    • /
    • 2016
  • Rehabilitation exercises are the treatments designed to help patients who are in the process of recovery from injury or illness to restore their body functions back to the original status. However, many patients suffering from chronic diseases have found difficulties visiting hospitals for the rehabilitation program due to lack of transportation, cost of the program, their own busy schedules, etc. Also, the program usually contains a few medical check-ups which can cause patients to feel uncomfortable. In this paper, we develop a remote rehabilitation system with bio-signals by a stereo camera. A Kinect stereo camera manufactured by Microsoft corporation was used to recognize the body movement of a patient by using its infrared(IR) camera. Also, we detect the chest area of a user from the skeleton data and process to gain respiratory status. ROI coordinates are created on a user's face to detect photoplethysmography(PPG) signals to calculate heart rate values from its color sensor. Finally, rehabilitation exercises and bio-signal detecting features are combined into a Windows application for the cost effective and high performance remote rehabilitation system.

Development of the Cryotherapy System (한냉물리치료기의 개발)

  • Kim, Y.H.;Yang, G.T.;Lim, S.H.;Chang, Y.H.;Ryu, J.S.;Kim, J.S.;Park, S.B.;Baek, S.S.;Chung, W.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.388-391
    • /
    • 1997
  • A cryotherapy system using the low temperature air was developed. The developed cryotherapy system had superior low temperature characteristics and many safety devices. For a clinical evaluation, skin and intra-articular temperatures of the knee joint were measured during and after the cryotherapy. After 5-minute therapy, skin and intra-articular temperature decreased by $23.3{\pm}4.7(^{\circ}C)$ and $4.1{\pm}1.0(^{\circ}C)$ respectively. A 5-minute cryotherapy therapy is good enough to maintain low intra-articular temperatures or 2-3 hours.

  • PDF

Development of the Gait Rehabilitation Equipment for Hemiplegic Patients after Stroke (편마비 환자를 위한 보행 재활기구 개발)

  • Nam, T.W.;Cho, J.M.;Kim, S.H.;Lim, J.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.5
    • /
    • pp.245-249
    • /
    • 2006
  • The aim of this study is to design and develop the gait rehabilitation equipment that judge patient's movement of his/her center of gravity using pressure sensors, and to aid hemiplegic patients to balance themselves using an automatic stepper that changes the patient's center of gravity. It is hard to bear the weight on the affected side for hemiplegic patients. The gait rehabilitation equipment detects the footing phase of hemiplegic patient during training and moves the unaffected footing side of the stepper up and moves the affected footing side down simultaneously so that the patient's center of gravity can shift from unaffected side to affected side. The gait rehabilitation system was developed and applied for hemiplegic patients during exercise. Eight hemiplegic patients and one normal adult were studied. The developed gait rehabilitation system could judge not only the normal adult's intention but also the patient's intention to move his/her center of gravity. Even though the most of hemiplegic patients exercised in automatic mode and a few hemiplegic patients exercised in manual mode, the developed gait rehabilitation system can aid the hemiplegic patients to train more easily.

Development of a Remote Shoulder Rehabilitation Exercise Device and Monitoring System (원격 어깨재활 운동 디바이스 및 모니터링 시스템 개발)

  • Kang, Byeong-Gwon;Choi, Soon;Kim, Jea Min;Kang, Hyun-Joo;Min, Se Dong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.7
    • /
    • pp.910-916
    • /
    • 2018
  • In this paper, we developed a shoulder rehabilitation exercise device and monitoring system to remotely provide rehabilitation system for the ones who need shoulder exercises including the patients with rotator cuff rupture. In order to evaluate the severity of shoulder muscle injury, a total of 4 shoulder rehabilitation exercises ((3) shoulder abduction, (2) shoulder flexion, (3) shoulder abduction with elbow flexion, (4) shoulder extension with elbow flexion) were selected and instructed to be performed with a 3 kg dumbbell for 5 times. For EMG (electromyogram) signal analysis, each subject's maximum voluntary contraction (MVC) was measured. EMG signals reflect the activation level of contracting muscles during dynamic exercises. Six participants' muscle activation levels in posterior deltoid, middle deltoid, upper trapezius, and infraspinatus were measured and compared. The mean power spectrum values in the time and frequency domains were compared between two age-matched groups (20s and 50s). The results showed lower muscle activation in the elderly subjects (n=3) compared to that of the ones in their twenties (n=3).

DECISION SUPPORT SYSTEM FOR SUBURBAN STATION REHABILITATION

  • TaeHoon Hong;Sangyoub Lee
    • International conference on construction engineering and project management
    • /
    • 2005.10a
    • /
    • pp.855-861
    • /
    • 2005
  • Every public agency governing infrastructure has to plan effectively for rehabilitation of existing facilities within the constraints of the capital program. Numerous technical, social, political, financial, and management constraints govern the decision to rehabilitate a facility. However, without a systematic procedure for selecting facilities for rehabilitation, within the prevailing constraints, it is possible that the funds available for rehabilitation might be suboptimized. Therefore, a decision support system that assists the user in selecting facilities for rehabilitation while considering the technical, social, financial, and political and management constraints will be useful in the decision-making process. This paper compares the Analytical Hierarchy Process (AHP) with the Swing Weight method used to prioritize functional criteria for suburban station rehabilitation. This paper also contains a brief discussion about the relevance of the Multi Attribute utility theory in developing a decision model for the problem at hand. The results of this paper provides the user with a decision support system that would prioritize the stations in order of their weights obtained by a systematic evaluation of various criteria and sub-criteria involved in the decision making process

  • PDF

Factors affecting real-time evaluation of muscle function in smart rehab systems

  • Hyunwoo Joe;Hyunsuk Kim;Seung-Jun Lee;Tae Sung Park;Myung-Jun Shin;Lee Hooman;Daesub Yoon;Woojin Kim
    • ETRI Journal
    • /
    • v.45 no.4
    • /
    • pp.603-614
    • /
    • 2023
  • Advancements in remote medical technologies and smart devices have led to expectations of contactless rehabilitation. Conventionally, rehabilitation requires clinicians to perform routine muscle function assessments with patients. However, assessment results are difficult to cross-reference owing to the lack of a gold standard. Thus, the application of remote smart rehabilitation systems is significantly hindered. This study analyzes the factors affecting the real-time evaluation of muscle function based on biometric sensor data so that we can provide a basis for a remote system. We acquired real clinical stroke patient data to identify the meaningful features associated with normal and abnormal musculature. We provide a system based on these emerging features that assesses muscle functionality in real time via streamed biometric signal data. A system view based on the amount of data, data processing speed, and feature proportions is provided to support the production of a rudimentary remote smart rehabilitation system.

Efficacy of Pharmacopuncture for Treating Children with Physical Disabilities in Uzbekistan

  • Zohidjon, Ismailov N.;Yu, Jun-Sang
    • Journal of Pharmacopuncture
    • /
    • v.16 no.2
    • /
    • pp.23-27
    • /
    • 2013
  • Objective: This research was performed to investigate the efficacy of complex rehabilitation combined with pharmacopuncture treatment for the children with neuromotor system diseases. Methods: Fifty (50) patients aged from 5 to 15 yr old were compared. Twenty (20) patients received conventional treatments and complex rehabilitation as a control group, and fifty (50) patients received complex rehabilitation with pharmacopuncture. At their first visits, the patients had checkups and neurological scales, and after 10 days of pharmacopuncture treatments and 55 days of rehabilitation, they also took neurological scales. We studied the pre and post effects of the treatment group. Results: The number of patients with ankle joint disorder and contracture, knee joint contracture, steppage, horsey hoof, shoulder weakness and contracture, radio-carpal joint disorder and contracture, arm hypotrophia, arm atrophia, leg hypotrophia and total atrophia decreased after treatments. Conclusion: This study showed the efficacy of pharmacopuncture combined with complex rehabilitation for the treatment of neuromotor system diseases.

The Evaluation of the Short-term Stress Effect on Cognitive Rehabilitation Training Assessment (인지 재활훈련 평가 시 단기 스트레스가 미치는 영향 연구)

  • Jang, Ik-Jae;Youn, Jong-In
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.6
    • /
    • pp.197-202
    • /
    • 2014
  • The cognitive rehabilitation training is important for treating many cognitive impairment conditions, including Parkinson's disease, stroke, and ADHD. In this study, we developed a new evaluation system to improve the measurement of the conventional evaluation systems for cognitive rehabilitation training. The developed system measured the activity of dopamine(DA) and an autonomic nervous system(ANS) with photoplethysmography and electromyography. The results demonstrated that the cognitive capacity was increased but the activity of DA was decreased with unbalanced ANS by short-term stress. Based on the results, the effect of short-term stress should be recognized for the cognitive rehabilitation training.

Full mounth rehabilitation using OP finder® system for patient with inadequate occlusal plane and multiple occlusal wear tooth state: a case report (부적절한 교합평면과 다수의 교합면 마모를 가진 환자에서 OP finder® system을 이용한 전악 수복증례)

  • Lee, Seon-Ki
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.3
    • /
    • pp.138-146
    • /
    • 2021
  • The diagnosis and treatment plan for forming ideal occlusal plane in full mouth rehabilitation are difficult because each process is complicated and information exchange between dentist and technician is subjective. The OP finder® system simplifies this process and helps to deliver more objective and accurate information. In this case, full mouth rehabilitation was performed using OP finder® system for patients with old bad fixed prosthesis and severely worn mandibular teeth, and reported that the result of proper occlusal plane setting and masticatory function recovery was obtained.