• Title/Summary/Keyword: Rehabilitation Robot System

Search Result 83, Processing Time 0.024 seconds

A Feasibility Study on a Robotic Exercise System for MDOF Physical Rehabilitation Therapy

  • Sim, Hyung Joon;Won, Joo Yeon;Han, Chang Soo
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.11
    • /
    • pp.1949-1960
    • /
    • 2004
  • This paper presents a robot system developed for medical purpose. A 6-degree-of-freedom robot was introduced for physical exercise and rehabilitation. This system was proposed for stroke patients or patients who cannot use one of their arms or legs. The robot system exercises the hemiplegic part based on the motion of normal part of a patient. Kinematic studies on the human body and robot were applied to develop the robotic rehabilitation exercise system. A clamp which acts as an end effector of the robot to hold a patient was designed and applied to the robot to guarantee the safety of patients. The proposed robotic rehabilitation system was verified by simulations and experiments on arm (elbow and shoulder) motion. Patients are expected to be able to exercise various motions by themselves with the proposed robotic rehabilitation system.

A Study on the Multi-Joint Rehabilitation System of an Industrial Robot

  • Lee, Yong-Seok;Jang, Jae-Ho;Sim, Hyung-Joon;Han, Chang-Soo;Han, Jung-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.92-95
    • /
    • 2004
  • This study proposes an industrial rehabilitation robot system which can exercise two joints in 3 dimensional spaces. The robot kinematics analysis and the results of studies on each joint for the rehabilitation robot could verify possibility of rehabilitation motion to exercise a joint. The force and torques sensor not only measures a rehabilitation performance of subjects between the abnormal limb and the manipulator, but also carries out an important function of safety device to prevent accidents. Also, limit sensors and emergency stop switch are used for high safety in this system. In this real test, the possibility of rehabilitation robot system is evaluated by C&R ARM I which is similar to upper-limb.

  • PDF

A Study on the Multi-Purpose Rehabilitation System for the Upper Limb Using a Robot Manipulator (로봇을 이용한 다기능 상지 재활 시스템에 관한 연구)

  • 원주연;심형준;박범석;한창수
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.11
    • /
    • pp.171-179
    • /
    • 2003
  • This paper presents a rehabilitation exercise system which utilizes a 6 DOF robot as a motion generator. This system was proposed for a stroke patient or a patient who has hemiplegia. A master-slave system was designed to exercise either paralysis or abnormal limb by using normal limb motion. The study on the human body was applied to calculate the motion range of elbows and shoulders. In addition, a force-torque sensor was applied to the slave robot to estimate the rehabilitation extent of the patient. Therefore, the stability of the rehabilitation robot could be improved. By using the rehabilitation robot. the patients could exercise by themselves without assistance. In conclusion, the proposed system was verified by computer simulations and system experiment.

Development of a 3-D Rehabilitation Robot System for Upper Extremities (상지 재활을 위한 3-D 로봇 시스템의 개발)

  • Shin, Kyu-Hyeon;Lee, Soo-Han
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.4
    • /
    • pp.64-71
    • /
    • 2009
  • A 3-D rehabilitation robot system is developed in this paper. The robot system is for the rehabilitation of upper extremities, especially the shoulder and elbow joints, and has 3-D workspace for enabling occupational therapy to recover physical functions in activities of daily living(ADL). The rehabilitation robot system, which is driven by actuators, has 1 DOF in horizontal rotational motion and 2 DOF in vertical rotational motion, where all actuators are set on the ground. Parallelogram linkage mechanisms lower the equivalent inertia of the control elements as well as control forces. Also the mechanisms have high mechanical rigidity for the end effector and the handle. Passive motion mode experiments have been performed to evaluate the proposed robot system. The results of the experiments show and excellent performance in simulating spasticity of patients.

Development of Rectangular-type Thumb Rehabilitation Robot for Stroke Patient's Thumb Rehabilitation Exercise (뇌졸중 환자의 엄지손가락 재활운동을 위한 직교형 엄지손가락 재활로봇 개발)

  • Kim, Hyeon-Min;Kim, Yong-Guk;Shin, Hee-Suk;Yoon, Jong-Won;Kim, Gab-Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.5
    • /
    • pp.516-523
    • /
    • 2012
  • Stroke patients should exercise for the rehabilitation of their fingers, because they can't use their hand and fingers. The moving direction of thumb of five fingers is different that of four fingers (force finger, middle finger, ring finger, little finger). The thumb rehabilitation robot for rehabilitation exercise must be included a force control system, because robot can injure thumb by applying too much force. In this paper, the rectangular-type thumb rehabilitation robot was developed for stroke patient's thumb rehabilitation exercise of the flexibility rehabilitation exercise. The characteristic test of the developed rectangular-type thumb rehabilitation robot was carried out with normal men in their twenties. As a result, it is thought that the robot can be used for the flexibility rehabilitation exercise of stroke patient's thumb.

Hybrid Position/Force Control of a 3-D Rehabilitation Robot System for Upper Extremities (상지 재활을 위한 3-D 로봇 시스템의 혼합 위치/힘 제어)

  • Lee, Soo-Han;Shin, Kyu-Hyeon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.5
    • /
    • pp.599-605
    • /
    • 2011
  • A 3-D rehabilitation robot system is developed. The robot system is for the rehabilitation of upper extremities, especially the shoulder and elbow joints, and has 3-D workspace for occupational therapy to recover physical functions in activities of daily living(ADL). The rehabilitation robot system has 1 DOF in horizontal rotational motion and 2 DOF in vertical rotational motion, where all actuators are set on the ground. Parallelogram linkage mechanisms lower the equivalent inertia of the control elements as well as control forces. Also the mechanisms have high mechanical rigidity for the end effector and the handle. In this paper, a hybrid position/force controller is used for controlling positions and forces simultaneously The controller is tuned according to the robot posture. The active motion modes for rehabilitation program consist of active-resisted motion mode and active-free motion mode. The results of the experiments show that the proposed motion modes provide the intended forces effectively.

Hand Pressing Control Using the Five-Axis Force/Moment Sensor of Finger Rehabilitation (손가락 재활로봇의 5축 힘/모멘트센서를 이용한 손 누름제어)

  • Kim, Hyeon-Min;Kim, Gab-Soon
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.192-197
    • /
    • 2012
  • This paper describes the control of the hand fixing system attached to the finger rehabilitation robot for the rehabilitation exercise of patient's fingers. The finger rehabilitation robot is used to exercise the finger rehabilitation, and a patient's hand is safely fixed using the hand fixing system. In this paper, the hand fixing system was controlled with PD gains to fix a palm of the hand, and the characteristic test for the hand fixing system was carried out to sense the fixed hand movement of the front and the rear, that of the left and the right, and that of the upper. It is thought that the hand fixing system could safely fix the hand, and the movement of the fixed hand could be perceived using the five-axis force/moment sensor attached to the hand fixing system.

Development of a 2-axis Delta Robot for Upper-limb Rehabilitation with Considering User Safety (사용자 안전요소를 고려한 상지 재활치료용 2축 델타로봇 개발)

  • Seung-Hwan Baek;Jun-Sik Lee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.1
    • /
    • pp.15-26
    • /
    • 2023
  • In this study, an end-effector robot which is a two-axis delta robot type for upper-limb rehabilitation is designed. It is not only rehabilitation functions that has designed robot but also mechanical and electrical safety devices were constructed to ensure patient safety. By constructing the two-axis delta robot is combined with an LM guide, the operating range and rigidity required for rehabilitation were secured. The electrical safety system which is required for the medical robot was designed, and a safety strategy was established to ensure patient safety and it is applied in the integrated safety circuit. The safety is considered in whole design process from the robot's mechanical design to the electric control unit.

A Development of Rehabilitation System for Upper Limb Using Robot Manipulator (로봇을 이용한 상지 재활 시스템에 관한 연구)

  • 원주연;심형준;한창수
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.309-318
    • /
    • 2003
  • In this paper a 6 degree-of-freedom robot was studied for medical purpose. In the past the robot used for industry field was utilized for medical robot but in these days the robot used for rehabilitation. welfare, and service. This system was Proposed for a stroke patient or a patient who can not use one arm. A master-slave system was constructed to exercise either paralysis or abnormal arm using normal arms movement. Study on the human body motion result was applied to calculate a movement range of humans elbow and shoulder. In addition, a force-torque sensor is applied to estimate the rehabilitation extent of the patient in the slave robot. Therefore, the stability of the rehabilitation robot could be improved. By using the rehabilitation robot, the Patient could exercise by himself without any assistance In conclusion. the proposed system and control algorithm were verified by computer simulation and system experiment.

Organization of Sensor System and User's Intent Detection Algorithm for Rehabilitation Robot (보행보조 재활로봇의 센서 시스템 구성 및 사용자 의도 감지 알고리즘)

  • Jung, Jun-Young;Park, Hyun-Sub;Lee, Duk-Yeon;Jang, In-Hun;Lee, Dong-Wook;Lee, Ho-Gil
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.10
    • /
    • pp.933-938
    • /
    • 2010
  • In this paper, we propose the organization of a sensor system and user's intent detection algorithm for walking assist rehabilitation robots. The main purpose of walking assist rehabilitation robots is assisting SCI patients to walk in normal environment. To use walking assist rehabilitation robot in normal environment, it is needed to consider various factors about user's safety and detection of user's intent and so on. For these purposes, we have analyzed the use case of rehabilitation robots and organized the system of sensors for walking assist rehabilitation robots and finally, we have developed the algorithm which is used to detect user's intent for those. We applied our proposal method in the rehabilitation robot, ROBIN, and verified their effectiveness by normal, not patient.