• Title/Summary/Keyword: Rehabilitation Device

Search Result 427, Processing Time 0.019 seconds

Development and Verification of Muscle Strength Effectiveness Based on Fitsig® (EMG Prototype)

  • Changjin Ji;Yong-hyun Byun;Sangho Kim
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.5
    • /
    • pp.111-121
    • /
    • 2024
  • With strength training comes the risk of injury and the benefits of exercise. Lack of knowledge and experience or repetitions at excessive intensity can lead to injury. Adequate feedback on an exercise's progress can increase the exercise's effectiveness and reduce injuries by providing scientific data and psychological motivation. This study aimed to validate EMG equipment and examine the effects of 8 weeks of biofeedback training with wireless electromyography. A correlation analysis between the Noraxon device and Fitsig®(EMG Prototype), a well-known instrument in the field of research, showed a moderate correlation. Statistically significant differences in humeral circumference, humeral muscle mass, and biceps and triceps strength were found between the left and right sides of the body over time, with no differences in the type of exercise. Feedback training with real-time EMG was found to be favorable for hypertrophic growth and strength improvement. Future studies should be conducted to investigate its application in sports activities further.

Clinical effects of additional use of erythritol powder air polishing device on non-surgical periodontal treatment in moderate chronic periodontitis (중등도 만성 치주염 환자에서 erythritol 공기분말 연마기구를 부가적으로 이용하는 비외과적 치주치료의 임상적 효과)

  • Lee, Mun-Young;Park, Eon-Jeong;Kwon, Eun-Young;Kim, Hyun-Joo;Lee, Ju-Youn;Joo, Ji-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.1
    • /
    • pp.39-45
    • /
    • 2018
  • Purpose: The purpose of this study was to evaluate the clinical effects of erythritol powder air polishing device (EPAP) in addition to scaling and root planing (SRP) in non-surgical periodontal treatment in moderate chronic periodontitis patients. Materials and Methods: Clinical evaluation was performed at 21 sites treated with SRP (control) and 21 sites treated with the addition of SRP+EPAP (test). All examinations were performed before treatment, 1 month after treatment, and 3 months after treatment. Depth of the periodontal pocket, gingival recession, clinical attachment level, plaque index, and bleeding of probing were measured as clinical parameters. Results: In both test and control groups, there was a significant decrease in the depth of the periodontal pocket, plaque index, bleeding of probing, increased gingival recession, and gain of clinical attachment level at 1 month and 3 months after treatment. However, there was no significant clinical difference between the test group and the control group. Clinical result was improved after 1 month compared to the baseline; in contrast, results at 3 months after treatment were worse than at 1 month after treatment. Conclusion: In this study, we cannot suggest that SRP + EPAP is clinically more effective than SRP alone as non-surgical periodontal treatments. Periodic periodontal therapy, at intervals of at least every three months, is important for sustaining effects of this treatment.

Importance and requirements for dental prosthesis order platform services: a survey of dental professionals (치과 보철물 거래 플랫폼 서비스의 중요성과 요구사항: 치과 전문가 설문조사)

  • Gyu-Ri Kim;Keunbada Son;Du-Hyeong Lee;So-Yeun Kim;Myoung-Uk Jin;Kyu-Bok Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.3
    • /
    • pp.105-118
    • /
    • 2023
  • Purpose: This study aimed to gain better understanding of the importance of dental prosthesis order platform services and to identify the essential elements for their enhancement and wider adoption among dental professionals. Materials and Methods: A survey was conducted to assess the perspectives of dentists, dental technicians, dental hygienists, and dental industry professionals toward dental prosthesis ordering and associated platform services (a total of 53 respondents). The questionnaire was devised after an expert review and assessed for reliability using Cronbach's alpha coefficient. Factor analysis revealed that 57 factors across five categories accounted for 88.417% of the total variance. The survey was administered through an online questionnaire platform, and data analysis was conducted using a statistical software, employing one-way analysis of variance and Tukey's honestly significant difference test (α = 0.05). Results: The essential elements identified were accurate information input, effective communication, delivery of distortion-free impressions, convenience in data transmission and storage, development of stable and affordable platform services (P < 0.05). Furthermore, significant differences were observed in the importance of these items based on age, dental profession, and career experience (P < 0.05). Conclusion: The dental prosthesis ordering platform services, the requirements of dental personnel were stability, economic efficiency, and ease of transmitting and storing prosthesis data. The findings can serve as important indicators for the development and improvement of dental prosthesis order platform services.

Effect of the magnetism(neodymium magnet) on growth factor receptors of osteoblasts (희토류 자석의 자성이 골모세포 성장인자 수용체의 증가에 미치는 영향에 관한 연구)

  • Lee, Sang-Min;Lee, Sung-Bok;Choi, Boo-Byung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.2
    • /
    • pp.87-96
    • /
    • 2003
  • The purposes of this study were to find out the optimum intensity of magnetic field where magnetism could promote the activity of osteoblast, and to discover the possibility of clinical application in the areas of dental implants and bone grafts by confirming the effect of clinically increasing bone formation. In this experiment, we used the Neodymium magnet, which had magnetic power six times as strong as the current ones and enabled the resistances against the demagnetization up to 20 to 50 times to be minimized with the size of 1mm in sight. In order to culture cells, a specially designed device was used. It was made to adjust the distance and accordingly to control the intensity of the magnetic field, by placing the cell culture plate in the center with a magnet of 1mm long and thick installed on the both ends. Using MC3T3-E1 cell, a kind of osteoblast-like cell, we cultured, for 24 hours, not only the test group which had been cultured under the magnetic fields with different intensity of 5, 10, 50, 100, 500, and 1000 Gauss, but also the control group excluding the influences of the magnetic field. After observing the cell's form and the density of the culture medium through an inverted microscope, we made a series of proceedings needed for the immunofluoroscence staining, such as fixation, normal serum reaction, primary antibody reaction, and secondary antibody reaction. And with a fluorescence microscope, we observed those-above and compared the frequency of expression of IFG-1 receptor. To make a Western immunoblotting analysis, the cells cultured under the same condition as the above had the procedure of the lysis buffer and the acrylamide gel electrophoresis was carried out. Protein transferred into the nitrocellulose membrane and tested on the primary and the secondary antibody reactions was observed and compared. The results were as follows: When observed through an inverted microscope, the nuclear divisions of the cells under the magnetic field of 10 Gauss were the most active, and the density of the cells could be observed the most enormously. As the result of an immunofluoroscence staining of IGF-1 receptor, the expression of IFG-1 was the most frequently observed under the magnetic field of 10 Gauss. On the other hand, few differences of consideration were made between the test group cultured under the magnetic fields of 5, 500, and 1000 Gauss and the control group. In respect of the expression of IFG-1 receptor, the test group cultured under the magnetic fields of 50 and 100 Gauss were higher than the control group, and lower than that cultured under the magnetic field of 10 Gauss.(p<0.05) According to the Western immunoblotting analysis, the band of IFG-1 receptor which had 85KDa of molecular weight was the darkest. Judging from the above-mentioned results, the growth factor receptor of an osteoblast cell which was an important criterion for the bone formation was increased in maximum under the magnetic field of 10 Gauss. Moreover it was observed that the optimum intensity of magnetic field in which magnetism made the activity of the osteoblast cell increase was about 10 Gauss.

Development of Evaluation Method for Jointed Concrete Pavement with FWD and Finite Element Analysis (FWD와 유한요소해석을 이용한 줄눈콘크리트포장 평가법 개발)

  • Yun, Kyong-Ku;Lee, Joo-Hyung;Choi, Seong-Yong
    • International Journal of Highway Engineering
    • /
    • v.1 no.1
    • /
    • pp.107-119
    • /
    • 1999
  • The joints in the jointed concrete pavement provide a control against transverse or longitudinal cracking at slab, which may be caused by temperature or moisture variation during or after hydration. Without control of cracking, random cracks cause more serious distresses and result in structural or functional failure of pavement system. However, joints nay cause distresses due to its inherent weakness in structural integrity. Thus, the evaluation at joint is very important. and the joint-related distresses should be evaluated reasonably for economic rehabilitation. The purpose of this paper was to develop an evaluation system at joints of jointed concrete pavement using finite element analysis program, ILLI-SLAB, and nondestructive testing device. FWD. To develop an evaluation system for JCP, a sensitivity analysis was performed using ILLI-SLAB program with a selected variables which might affect fairly to on the performance of transverse joints. The most significant variables were selected from precise analysis. An evaluation charts were made for jointed concrete pavement by adopting the field FWD data. It was concluded that the variables which most significantly affect to pavement deflections are the modulus of subgrade reaction(K) and the modulus of dowel/concrete interaction(G), and limiting criteria on the performance of joints at JCP are 300pci. 500,000 lb/in. respectively. Using these variables and FWD test, a charts of load transfer ratio versus surface deflection at joints were made in order to evaluate the performance of JCP. Practically, Chungbu highway was evaluated by these evaluation charts and FWD field data for jointed concrete pavement. For Chungbu highway, only one joint showed smaller value than limiting criterion of the modulus of dowel/concrete interaction(G). The rest joints showed larger values than limiting criteria of the modulus of subgrade reaction(K) and the modulus of dowel/concrete interaction(G).

  • PDF

Operative treatment for Proximal Humeral Fracture (상완골 근위부 골절의 수술적 요법)

  • Park Jin-Young;Park Hee-Gon
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.2
    • /
    • pp.168-175
    • /
    • 2003
  • Fracture about proximal humerus may be classified as the articular segment or the anatomical neck, the greater tuberosity, the lesser tuberosity, and the shaft or surgical neck. Now, usually used, Neer's classification is based on the number of segments displaced, over 1cm of displaced or more than 45 degrees of angulation , rather than the number of fracture line . Absolute indication of a operative treatment a open fracture, the fracture with vascular injury or nerve injury , and unreductable fracture-dislocation . Inversely, the case that are severe osteoporosis, and eldly patient who can't be operated by strong internal fixation is better than arthroplasty used by primary prosthetic replacement and early rehabilitation program than open reduction and internal fixation. The operator make a decision for the patient who should be taken the open reduction and internal fixation, because it's different that anatomical morphology, bone density, condition of patient. The operator decide operation procedure. For example, percutaneous pinning, open reduction, plate & screws, wire tension bands combined with some intramedullary device are operation procedure that operator can decide . The poor health condition for other health problem, fracture with unstable vital sign and severe osteoporosis , are the relative contraindication. The stable fracture without dislocation is not the operative indication . The radiologic film of the prokimal humerus before the operation can not predict for fracture evaluation. It's necessary to good radiologic film for evaluation of fracture form. The trauma serise is better than the other radiologic film for evaluation. The accessary radiologic exam is able to help for evaluation of bone fragment and anatomy. The CT can be helpful in evaluating these injury, especially if the extract fracture type cannot be determined from plain roenterogram of the proximal humerus, bone of humerus head. If the dislocation is severe anatomically , we could consider to do three dimentional remodelling. The MRI doing for observing of bony morphology before the operation is not better than CT If we were suspicious of vascular injury, we could consider the angiography.

  • PDF

Neurotechnologies and civil law issues (뇌신경과학 연구 및 기술에 대한 민사법적 대응)

  • SooJeong Kim
    • The Korean Society of Law and Medicine
    • /
    • v.24 no.2
    • /
    • pp.147-196
    • /
    • 2023
  • Advances in brain science have made it possible to stimulate the brain to treat brain disorder or to connect directly between the neuron activity and an external devices. Non-invasive neurotechnologies already exist, but invasive neurotechnologies can provide more precise stimulation or measure brainwaves more precisely. Nowadays deep brain stimulation (DBS) is recognized as an accepted treatment for Parkinson's disease and essential tremor. In addition DBS has shown a certain positive effect in patients with Alzheimer's disease and depression. Brain-computer interfaces (BCI) are in the clinical stage but help patients in vegetative state can communicate or support rehabilitation for nerve-damaged people. The issue is that the people who need these invasive neurotechnologies are those whose capacity to consent is impaired or who are unable to communicate due to disease or nerve damage, while DBS and BCI operations are highly invasive and require informed consent of patients. Especially in areas where neurotechnology is still in clinical trials, the risks are greater and the benefits are uncertain, so more explanation should be provided to let patients make an informed decision. If the patient is under guardianship, the guardian is able to substitute for the patient's consent, if necessary with the authorization of court. If the patient is not under guardianship and the patient's capacity to consent is impaired or he is unable to express the consent, korean healthcare institution tend to rely on the patient's near relative guardian(de facto guardian) to give consent. But the concept of a de facto guardian is not provided by our civil law system. In the long run, it would be more appropriate to provide that a patient's spouse or next of kin may be authorized to give consent for the patient, if he or she is neither under guardianship nor appointed enduring power of attorney. If the patient was not properly informed of the risks involved in the neurosurgery, he or she may be entitled to compensation of intangible damages. If there is a causal relation between the malpractice and the side effects, the patient may also be able to recover damages for those side effects. In addition, both BCI and DBS involve the implantation of electrodes or microchips in the brain, which are controlled by an external devices. Since implantable medical devices are subject to product liability laws, the patient may be able to sue the manufacturer for damages if the defect caused the adverse effects. Recently, Korea's medical device regulation mandated liability insurance system for implantable medical devices to strengthen consumer protection.